Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heliyon ; 9(8): e18992, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37609400

RESUMO

With the rapid development of industry, the increasing discharge of sewage causes the detection of water quality to be of increasing importance. Potassium dichromate titration is one of the most important testing methods in water quality detection; the ability to accurately identify the titration end-point of potassium dichromate is currently a research challenge. To identify titration end-point quickly and accurately, this study proposes a ResNet14Attention network, which utilizes residual modules that focus on original image information and an attention mechanism that focuses highly on classification targets. The proposed ResNet14Attention network is compared with 12 convolutional neural networks such as ResNet series networks, VGG, and GoogLeNet. The results of comparison experiments reveal that only the proposed ResNet14Attention network has the highest training and testing accuracy of 100% among all convolutional neural networks in the comparison experiment; the proposed ResNet14Attention network has the highest training speed compared to all the networks that over 90% accuracy.

2.
J Colloid Interface Sci ; 636: 351-362, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36638574

RESUMO

Dual-band electrochromic materials (DBEMs) are of utmost importance for smart windows to realize independent control of the visible (VIS) and near-infrared (NIR) light. However, very few single-component DBEMs are capable of independently and effectively controlling both VIS and NIR light. Here, we present Prussian blue (PB) with remarkable performance to replace the composite DBEMs that require deliberate design and complicated preparation. Excellent durability and capacity were achieved simultaneously due to the activated low-spin Fe in PB. A dual-band electrochromic device (DBED) by using PB thin films as electrochromic layers was constructed, exhibiting superior dual-band electrochromic performance, energy storage performance and memory effect. We show that the energy-saving DBED can be bleached without applying any external bias potential, and can be colored by using a commercial photovoltaic solar panel under ambient solar irradiation. The stored energy during coloration can be further used to light up the lights. Finally, the coloration mechanism of the DBED was studied by the density functional theory calculations, to shed light on the large optical transmittance modulation in both VIS and NIR regions. The new insights will advance the design of efficient and durable DBEMs and the development of bi-functional smart windows.

3.
J Mater Chem A Mater ; 7(6): 2908-2918, 2019 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-30931123

RESUMO

Electrochromic windows and glass facades are able to impart energy efficiency jointly with indoor comfort and convenience. Long-term durability is essential for practical implementation of this technology and has recently attracted broad interest. Here we show that a simple potentiostatic pretreatment of sputter-deposited thin films of amorphous WO3-the most widely studied electrochromic material-can yield unprecedented durability for charge exchange and optical modulation under harsh electrochemical cycling in a Li-ion-conducting electrolyte and effectively evades harmful trapping of Li. The pretreatment consisted of applying a voltage of 6.0 V vs. Li/Li+ for several hours to a film backed by a transparent conducting In2O3:Sn layer. Associated compositional and structural modifications were probed by several techniques, and improved durability was associated with elemental intermixing at the WO3/ITO and ITO/glass boundaries as well as with carbonaceous solid-electrolyte interfacial layers on the WO3 films. Our work provides important new insights into long-term durability of ion-exchange-based devices.

4.
ACS Appl Mater Interfaces ; 9(49): 42420-42424, 2017 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-29164852

RESUMO

Nickel oxide thin films are of major importance as anodically coloring components in electrochromic smart windows with applications in energy-efficient buildings. However, the optical performance of these films degrades upon extended electrochemical cycling, which has hampered their implementation. Here, we use a potentiostatic treatment to rejuvenate degraded nickel oxide thin films immersed in electrolytes of LiClO4 in propylene carbonate. Time-of-flight elastic recoil detection analysis provided unambiguous evidence that both Li+ ions and chlorine-based ions participate in the rejuvenation process. Our work provides new perspectives for developing ion-exchange-based devices embodying nickel oxide.

5.
Analyst ; 128(5): 462-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12790198

RESUMO

Nanometer-sized fluorescent hybrid silica (NFHS) particles were prepared for use as sensitive and photostable fluorescent probes in biological staining and diagnostics. The first step of the synthesis involves the covalent modification of 3-aminopropyltrimethoxysilane with an organic fluorophore, such as fluorescein isothiocyanate, under N2 atmosphere for getting a fluorescent silica precursor. Then the NFHS particles, with a diameter of well below 40 nm, were prepared by controlled hydrolysis of the fluorescent silica precursor with tetramethoxysilane (TMOS) using the reverse micelle technique. The fluorophores are dispersed homogeneously in the silica network of the NFHS particles and well protected from the environmental oxygen. Furthermore, since the fluorophores are covalently bound to the silica network, there is no migration, aggregation and leakage of the fluorophores. In comparison with common single organic fluorophores, these particle probes are brighter, more stable against photobleaching and do not suffer from intermittent on/off light emission (blinking). We have used these newly developed NFHS particles as a fluorescent marker to label antibodies, using silica immobilization method, for the immunoassay of human alpha-fetoprotein (AFP). The detection limit of this method was down to 0.05 ng mL(-1) under our current experimental conditions. We think this material would attract much attention and be applied widely in biotechnology.

6.
Anal Biochem ; 308(1): 71-6, 2002 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12234465

RESUMO

Sol-gel-derived mesoporous biomaterials were used for the first time in the flow-injection fluorescence immunoassay system. Anti-gentamicin antibody was immobilized in a mesoporous sol-gel material using tetramethoxysilane as a precursor and poly(ethylene glycol) as a template. The sol-gel glass was used to develop an immunoaffinity column for the flow-injection immunoassay of gentamicin. Little unspecific adsorption of gentamicin on the sol-gel and no antibody leaching under harsh elution conditions were found. The immunoassay is based on the competition between gentamicin and fluorescein isothiocyanate-labeled gentamicin for a limited number of encapsulated antibody binding sites. NaOH solution of 5 x 10(-3)mol/L is used for the regeneration of encapsulated antibody binding sites after each measurement, which allows the immunoreactor to be used for up to 20 times without any loss of reactivity. Sample preconcentration is not needed and a single assay can be performed within 10 min. The calibration for gentamicin has a working range of 250-5000 ng/mL with a detection limit of 200 ng/mL, which is close to that of the fluorescence immunoassay and fluorescence polarization immunoassay using the same reactants. Comparison of the results from this method with that obtained from HPLC showed an excellent correlation.


Assuntos
Materiais Biocompatíveis/química , Análise de Injeção de Fluxo/métodos , Imunoensaio de Fluorescência por Polarização/métodos , Gentamicinas/sangue , Adsorção , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Ligação Competitiva , Calibragem , Cromatografia Líquida de Alta Pressão , Análise de Injeção de Fluxo/instrumentação , Fluoresceína-5-Isotiocianato/química , Imunoensaio de Fluorescência por Polarização/instrumentação , Géis , Gentamicinas/análise , Humanos , Polietilenoglicóis/química , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA