Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 39(5): 771-81, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22258713

RESUMO

PURPOSE: The aim of the study was to evaluate the volumetric integration patterns of standard MRI and (11)C-methionine positron emission tomography (PET) images in the surgery planning of gliomas and their relationship to the histological grade. METHODS: We studied 23 patients with suspected or previously treated glioma who underwent preoperative (11)C-methionine PET because MRI was imprecise in defining the surgical target contour. Images were transferred to the treatment planning system, coregistered and fused (BrainLAB). Tumour delineation was performed by (11)C-methionine PET thresholding (vPET) and manual segmentation over MRI (vMRI). A 3-D volumetric study was conducted to evaluate the contribution of each modality to tumour target volume. All cases were surgically treated and histological classification was performed according to WHO grades. Additionally, several biopsy samples were taken according to the results derived either from PET or from MRI and analysed separately. RESULTS: Fifteen patients had high-grade tumours [ten glioblastoma multiforme (GBM) and five anaplastic), whereas eight patients had low-grade tumours. Biopsies from areas with high (11)C-methionine uptake without correspondence in MRI showed tumour proliferation, including infiltrative zones, distinguishing them from dysplasia and radionecrosis. Two main PET/MRI integration patterns emerged after analysis of volumetric data: pattern vMRI-in-vPET (11/23) and pattern vPET-in-vMRI (9/23). Besides, a possible third pattern with differences in both directions (vMRI-diff-vPET) could also be observed (3/23). There was a statistically significant association between the tumour classification and integration patterns described above (p < 0.001, κ = 0.72). GBM was associated with pattern vMRI-in-vPET (9/10), low-grade with pattern vPET-in-vMRI (7/8) and anaplastic with pattern vMRI-diff-vPET (3/5). CONCLUSION: The metabolically active tumour volume observed in (11)C-methionine PET differs from the volume of MRI by showing areas of infiltrative tumour and distinguishing from non-tumour lesions. Differences in (11)C-methionine PET/MRI integration patterns can be assigned to tumour grades according to the WHO classification. This finding may improve tumour delineation and therapy planning for gliomas.


Assuntos
Glioma/diagnóstico , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Metionina , Tomografia por Emissão de Pósitrons/métodos , Carga Tumoral , Adolescente , Adulto , Idoso , Feminino , Glioma/diagnóstico por imagem , Glioma/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Fatores de Tempo , Adulto Jovem
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32201272

RESUMO

OBJECTIVE: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration. MATERIAL AND METHODS: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation method and coated with 4 different polymers; HPMC, GMN2, GPM2 and GTM2. They were purified, lyophilized and characterized. Radiolabelling with 99mTc was perfomed with 74 MBq of 99mTc sodium pertechnetate, previously reduced with and acid solution of tin chloride at different concentrations (0.003, 0.005, 0.007, 0.01, 0.05 and 0.1mg/ml) and at different times (5, 10, 15, 30 and 60minutes) and temperatures (room temperature, 40°C and 60°C). Radiolabelling with 67Ga was perfomed by incubation of the nanoparticles with 37 MBq of 67Gallium chloride (obtained from commercial gallium-67 citrate) at different times (10 and 30minutes) and temperatures (room temperature, 30°C and 60°C), and posterior purification with microconcentrators. The radiochemical purity was evaluated by TLC. Stability studies of radiolabeled nanoparticles in physiological serum and blood plasma were perfomed. Biodistribution studies of nanoparticles coated with GPM2 polymer were carried out in Wistar rats after intravenous administration of the nanoparticles. Control animals were carried out with 99mTc sodium pertechnetate and 67Ga chloride. To do so, the animals were killed and activity in organs was measured in a gamma counter. RESULTS: 99mTc labeling was carried out optimally with a tin concentration of 0.007mg/ ml for the GPM2 nanoparticles and 0.005mg / ml for the rest of the formulations, with a radiolabelling time of 10minutes at room temperature. In the case of 67Ga the label was optimized at 30° C temperature and 30minutes of incubation. In both cases the radiochemical purity obtained was greater than 97%. The nanoparticles showed high stability in vitro after 48hours of labeling (70% nanoparticles labeled with 99mTc and 90% those labeled with 67Ga). Biodistribution studies of nanoparticles 99mTc -GPM2 and 67Ga -NOTA-GPM2 showed a high accumulation of activity in the liver at 2 and 24hours after intravenous administration. CONCLUSION: The labeling procedure with 99mTc and 67Ga of albumin and albumin modified with NOTA nanoparticles allows obtaining nanoparticles with high labeling yields and adequate in vitro stability, allowing their use for in vivo studies.


Assuntos
Radioisótopos de Gálio/farmacocinética , Gálio/farmacocinética , Marcação por Isótopo/métodos , Nanopartículas/administração & dosagem , Poliaminas/química , Compostos Radiofarmacêuticos/farmacocinética , Albumina Sérica Humana/farmacocinética , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio/farmacocinética , Tiamina/química , Animais , Cromatografia em Camada Fina , Estabilidade de Medicamentos , Feminino , Gálio/administração & dosagem , Gálio/análise , Radioisótopos de Gálio/administração & dosagem , Radioisótopos de Gálio/análise , Compostos Heterocíclicos com 1 Anel , Derivados da Hipromelose , Injeções Intravenosas , Nanopartículas/análise , Polietilenoglicóis , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/análise , Ratos , Ratos Wistar , Albumina Sérica Humana/administração & dosagem , Albumina Sérica Humana/análise , Tecnécio/administração & dosagem , Tecnécio/análise , Temperatura , Compostos de Estanho , Distribuição Tecidual
3.
Gene Ther ; 16(1): 136-41, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18668147

RESUMO

Non-invasive in vivo imaging of transgene expression is currently providing very important means to optimize gene therapy regimes. Results in non-human primates are considered the most predictive models for the outcome in patients. In this study, we have documented that tumour and primary cell lines from human and non-human primates are comparably gene-transduced in vitro by serotype 5 adenovirus expressing HSV1-thymidine kinase. Transgene expression can be quantified in human and monkey cultured cells by positron emission tomography (PET) imaging when transduced cells are incubated with a fluoride-18 labelled penciclovir analogue. In our hands, PET images of cell cultures estimate the number of transduced cells rather than intensity of transgene expression once a threshold of TK per cell is reached. Interestingly, in vivo systemic administration of a clinical grade recombinant adenovirus expressing TK into macaques gives rise to an intense retention of the radiotracer in the liver parenchyma, providing an experimental system to visualize transgene expression that ought to be similar in human and macaques. Such imaging methodology might contribute to improve strategies based on adenoviral vectors.


Assuntos
Terapia Genética/métodos , Herpesvirus Humano 1/enzimologia , Fígado/diagnóstico por imagem , Fígado/enzimologia , Tomografia por Emissão de Pósitrons , Timidina Quinase/genética , Aciclovir/análogos & derivados , Aciclovir/farmacologia , Adenoviridae/genética , Animais , Contagem de Células , Linhagem Celular Transformada , Expressão Gênica , Vetores Genéticos/administração & dosagem , Vetores Genéticos/genética , Guanina , Humanos , Injeções Intravenosas , Macaca , Modelos Animais , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacologia , Transdução Genética/métodos , Transgenes
4.
Neuroimage ; 47(2): 533-9, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19422919

RESUMO

Normalization of neuroimaging studies to a stereotaxic space allows the utilization of standard volumes of interest (VOIs) and voxel-based analysis (SPM). Such spatial normalization of PET and MRI studies requires a high quality template image. The aim of this study was to create new MRI and PET templates of (18)F-DOPA and (11)C-(+)-alpha-dihydrotetrabenazine ((11)C-DTBZ) of the Macaca fascicularis brain, an important animal model of Parkinson's disease. MRI template was constructed as a smoothed average of the scans of 15 healthy animals, previously transformed into the space of one representative MRI. In order to create the PET templates, (18)F-DOPA and (11)C-DTBZ PET of the same subjects were acquired in a dedicated small animal PET scanner and transformed to the created MRI template space. To validate these templates for PET quantification, parametric values obtained with a standard VOI-map applied after spatial normalization to each template were statistically compared to results computed using individual VOIs drawn for each animal. The high correlation between both procedures validated the utilization of all the templates, improving the reproducibility of PET analysis. To prove the utility of the templates for voxel-based quantification, dopamine striatal depletion in a representative monkey treated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) was assessed by SPM analysis of (11)C-DTBZ PET. A symmetric reduction in striatal (11)C-DTBZ uptake was detected in accordance with the induced lesion. In conclusion, templates of M. fascicularis brain have been constructed and validated for reproducible and automated PET quantification. All templates are electronically available via the internet.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Di-Hidroxifenilalanina/análogos & derivados , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tetrabenazina/análogos & derivados , Animais , Radioisótopos de Carbono , Macaca fascicularis , Compostos Radiofarmacêuticos , Valores de Referência , Técnica de Subtração
5.
Int J Pharm ; 569: 118484, 2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31260785

RESUMO

Re-activation of the healing process is a major challenge in the field of chronic wound treatment. For that purpose, lipid-nanoparticles, especially nanostructured lipid carriers (NLC), possess extremely useful characteristics such as biodegradability, biocompatibility and long-term stability, besides being suitable for drug delivery. Moreover, they maintain wound moisture due to their occlusive properties, which have been associated with increased healing rates. In the light of above, NLC have been extensively used topically for wound healing; but to date, there are no safety-preclinical studies concerning such type of application. Thus, in this work, biodistribution studies were performed in rats with the NLC previously developed by our research group, using technetium-99 m (99mTc-NLC) as radiomarker, topically administered on a wound. 99mTc-NLC remained on the wound for 24 h and systemic absorption was not observed after administration. In addition, toxicological studies were performed to assess NLC safety after topical administration. The results obtained demonstrated that NLC were non-cytotoxic, non-sensitizing and non-irritant/corrosive. Overall, it might be concluded that developed NLC remained at the administration area, potentially exerting a local effect, and were safe after topical administration on wounds.


Assuntos
Portadores de Fármacos/administração & dosagem , Lipídeos/administração & dosagem , Nanoestruturas/administração & dosagem , Animais , Células 3T3 BALB , Sobrevivência Celular/efeitos dos fármacos , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/toxicidade , Feminino , Lipídeos/farmacocinética , Lipídeos/toxicidade , Masculino , Camundongos , Camundongos Endogâmicos CBA , Nanoestruturas/toxicidade , Coelhos , Ratos Wistar , Pele/efeitos dos fármacos , Testes de Irritação da Pele , Tecnécio , Distribuição Tecidual , Cicatrização/efeitos dos fármacos
6.
Rev Esp Med Nucl ; 27(2): 103-11, 2008.
Artigo em Espanhol | MEDLINE | ID: mdl-18367048

RESUMO

AIM: This study evaluates the utility of (11)C-(+)-alpha -dihydrotetrabenazine ((11)C-(+)DTBZ) in the quantification of dopaminergic innervation by positron emission tomography (PET) in rat and monkey, two animal species used as animal models of Parkinson's disease. MATERIAL AND METHODS: Healthy control animals (n = 10) and the effect of 6-hydroxidopamine (6-OHDA) neurotoxic were studied in rats. (18)F-DOPA PET studies and digital quantitative autoradiography were also carried out. Studies with Macaca fascicularis were performed in control and 1-methyl 4-phenyl 1, 2, 3, 6-tetrahydropyridine (MPTP) treated animals. RESULTS: In both species high quality images were generated in which clear uptake of (11)C-(+)DTBZ was found in the striatum. (11)C-(+)DTBZ uptake quantification was estimated by creating parametric images and binding potential (BP) calculation. BP in control rats was 1.10 +/- 0.16 (mean +/- standard deviation [SD], whereas 6-OHDA produced a decrease in the uptake depending on the lesion degree. Images obtained with (18)F-DOPA were not adequate for the analysis as they did not discriminate the stratum whereas digital quantitative autoradiography studies confirmed the high affinity of striatum by (11)C-(+)DTBZ. In monkeys, final BP values were 1.31 and 1.06 and MPTP treatment reduced uptake by 40 %. CONCLUSIONS: The quality of PET images and the decrease of uptake in 6-OHDA and MPTP lesions show that (11)C-(+)DTBZ is an adequate radiotracer for the study of dopaminergic innervation in these animal models.


Assuntos
Doença de Parkinson/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Receptores Dopaminérgicos , Tetrabenazina/análogos & derivados , Animais , Macaca fascicularis , Masculino , Ratos
7.
Rev Esp Med Nucl ; 27(1): 13-21, 2008.
Artigo em Espanhol | MEDLINE | ID: mdl-18208777

RESUMO

UNLABELLED: Dihydrotetrabenazine (2-hydroxy-3-isobutyl-9,10-dimethoxy-1,3,4,6,7-hexahydro-11bH-benzo[a]-quinolizine, DTBZ) has become the ideal radioligand for the presynaptic vesicular monoamine transporter VMAT2 based on its high binding affinity and optimal lipophilicity. OBJECTIVE: To develop an automatic procedure for labelling DTBZ with carbon-11, which has been shown to be a highly effective marker for in vivo studies of neuronal losses in animal models with Parkinson's disease using positron emission tomography (PET). MATERIALS AND METHODS: We have developed a new fully automated synthesis procedure to obtain 11C-(+)DTBZ quickly and simply through labelling the precursor -(+)desmethyldihy-drotetrabenazine- at room temperature in the presence of dimethyl sulfoxide (DMSO) and potassium hydroxide (KOH), using 11CH3I as primary precursor. The final purification was carried out by solid phase extraction using commercially available cartridges and the residual solvents (DMSO and ethyl ether) were eliminated by evaporation. RESULTS: The whole procedure was automated, and after 54 syntheses, an average production of 1.94 GBq of sterile, pyrogen-free 11C-(+)DTBZ with a radiochemical purity > 99 % was obtained with 5 minutes irradiation and 6 minutes of synthesis after 11CH3I production. 11C-(+)DTBZ binding to presynaptic dopamine nerve terminals has been demonstrated by MicroPET studies in Wistar rats and M. Fascicularis monkeys. CONCLUSIONS: This new synthesis procedure is quick and simple, due to optimised techniques, which have allowed elimination of residual solvents based on their polarity for the final purification. It is also applicable to other automatic syntheses for obtaining compounds labelled by methylation reactions.


Assuntos
Radioisótopos de Carbono , Tomografia por Emissão de Pósitrons/métodos , Terminações Pré-Sinápticas/diagnóstico por imagem , Ensaio Radioligante , Compostos Radiofarmacêuticos/síntese química , Tetrabenazina/análogos & derivados , Proteínas Vesiculares de Transporte de Monoamina/análise , Automação , Cromatografia Líquida de Alta Pressão , Dimetil Sulfóxido , Dopamina , Contaminação de Medicamentos , Endotoxinas/análise , Éter , Humanos , Marcação por Isótopo/métodos , Terminações Pré-Sinápticas/química , Terminações Pré-Sinápticas/ultraestrutura , Controle de Qualidade , Receptores Pré-Sinápticos/química , Solventes , Tetrabenazina/síntese química
8.
Rev Med Univ Navarra ; 52(1): 4-12, 2008.
Artigo em Espanhol | MEDLINE | ID: mdl-18578191

RESUMO

PET18FDG is an imaging diagnostic technique that shows changes in glycolitic metabolism that appear at a very early phases in the tumoral process. The main limitation of PET in breast cancer is the detection of small tumor lesions and axillary micrometastases. However it offers important information in the staging of high risk patients, in clinical relapse or in therapeutic evaluation. The new PET-CT devices offer advantages over conventional techniques. It provides a greater precision in the localization of tumoral foci. In spite of current difficulties for clinical applications, fluoro-estradiol (18F-ES) offers the possibilty of studying the presence of estrogenic receptors both in the primary and in the metastases. It may prove to be a useful tool to obtain information about therapeutic management and prognosis of breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Neoplasias da Mama/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
9.
Radiat Prot Dosimetry ; 126(1-4): 477-81, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17504752

RESUMO

Neutron organ equivalent doses, effective doses and dose equivalents received inside a positron emission tomography vault room in a maximum credible accident have been estimated with the Monte Carlo code MCNPX. While an operator was inside the vault room of a Cyclone 18/9 IBA cyclotron, this was producing (18)F with 30 muA proton current in the target and the operator had to activate a stopped emergency device placed on the wall. MC simulation of the cyclotron vault were carried out to estimate the organ and tissue equivalent doses in a mathematical male mannequin simulating the operator facing the wall on which the emergency device is placed. Doses were calculated at two emergency devices for each one of the two targets of the cyclotron, which were able to produce (18)F. The maximum effective dose in the mannequin was 6.70 Sv/h and the maximum organ equivalent dose was 18.47 Sv/h in spleen.


Assuntos
Ciclotrons , Corpo Clínico , Modelos Biológicos , Nêutrons , Exposição Ocupacional/análise , Tomografia por Emissão de Pósitrons/instrumentação , Radiometria/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Masculino , Modelos Estatísticos , Método de Monte Carlo , Doses de Radiação , Espanha
10.
Radiat Prot Dosimetry ; 126(1-4): 371-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17575290

RESUMO

Positron emission tomography (PET) is a non-invasive medical imaging technique normally used for diagnostic purposes to determine the location and concentration of physiologically active compounds in a human body. An unshielded cyclotron is used for PET at the Clinica Universitaria de Navarra to produce short-lived positron emitting radionuclides ((15)O, (13)N, (11)C and (18)F) by bombarding appropriate target material with proton or deuteron beams with energies up to 18 and 9 MeV, respectively. Subsequent nuclear reactions may generate undesirable neutrons that should be evaluated and controlled. In this study, the neutron measurements performed with an active and a passive Bonner sphere systems at different locations outside and inside the cyclotron vault during operation have been presented. The neutron spectrum at each location was determined with an unfolding code developed by the authors.


Assuntos
Nêutrons , Tomografia por Emissão de Pósitrons/instrumentação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha
12.
EJNMMI Res ; 5(1): 70, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26635227

RESUMO

BACKGROUND: [(18)F]-tetrafluoroborate is a PET radiotracer taken up by the sodium/iodide symporter (NIS). Albeit the in vivo behavior in rodents is similar to the (99m)Tc-pertechnetate, no studies exist in primates or in humans. The aims of this study were to evaluate the biodistribution of [(18)F]-tetrafluoroborate in non-human primates with PET and to estimate the absorbed dose in organs. METHODS: Whole-body PET imaging was done in a Siemens ECAT HR+ scanner in two male Macaca fascicularis monkeys. After an i.v. injection of 24.93 ± 0.05 MBq/kg of [(18)F]-tetrafluoroborate, prepared by isotopic exchange of sodium tetrafluoroborate with [(18)F]-fluoride under acidic conditions, eight sequential images from the head to the thigh (five beds) were collected for a total duration of 132 min. The whole-body emission scan was reconstructed applying attenuation and scatter corrections. After image reconstruction, three-dimensional volumes of interest (VOIs) were hand-drawn on the PET transaxial or coronal slices of the frame where the organ was most conspicuous. Time-activity curves for each VOI were obtained, and the organ residence times were calculated by integration of the time-activity curves. Human absorbed doses were estimated using the OLINDA/EXM software and the standard human model. RESULTS: [(18)F]-tetrafluoroborate was able to discriminate clearly the thyroid gland with an excellent signal-to-noise ratio. Most of the radiotracers (residence time) are localised in the organs that express NIS (stomach wall, salivary glands, thyroid, olfactory mucosa), are involved in excretion (kidneys and bladder), or reflect the vascular phase (heart and lungs). Considering the OLINDA source organs, the critical organs were the stomach wall, thyroid and bladder wall, with absorbed doses lower than 0.078 mGy/MBq. The effective dose was 0.025 mSv/MBq. CONCLUSIONS: [(18)F]-tetrafluoroborate is a very useful radiotracer for PET thyroid imaging in primates, with a characteristic biodistribution in organs expressing NIS. It delivers an effective dose slightly higher than the dose produced by (99m)Tc-pertechnetate but much lower than that produced by radioiodine in the form of (131)INa, (123)INa, or (124)INa.

13.
Rev Esp Med Nucl Imagen Mol ; 32(2): 92-7, 2013 Mar.
Artigo em Espanhol | MEDLINE | ID: mdl-23332663

RESUMO

PURPOSE: To optimize radiolabeling with (99m)Tc of mannosylated Gantrez(®) nanoparticles loaded with the Brucella Ovis antigen (Man-NP-HS) and to carry out biodistribution studies in mice after ocular administration of the nanoparticles. MATERIAL AND METHODS: Man-NP-HS nanoparticles were prepared by the solvent displacement method. They were purified, lyophilized and characterized. Following this, they were radiolabeled with 74 MBq of (99m)TcO4(-) previously reduced with an acidic stannous chloride solution, working in absence of oxygen and at a final pH of 4. Radiolabeling yield was evaluated by TLC. Biodistribution studies were carried out in mice after ocular administration of the formulation and control of free (99m)TcO4(-). To do so, the animals were humanely killed at 2 and 24hours after the ocular administration and activity in organs was measured in a Gamma counter. RESULTS: Radiolabeling yield obtained was greater than 90%. Biodistribution studies of (99m)Tc-Man-NP-HS showed radioactivity accumulated at 2 and 24hours in nasal and ocular mucosa and gastrointestinal tract, in contrast to biodistribution of free (99m)TcO4(-) that remained concentrated in the skin around the eye and gastrointestinal tract. CONCLUSION: Biodistribution studies of (99m)Tc-Man-NP-HS after ocular instillation have made it possible to demonstrate its biodistribution in nasal mucosa and gastrointestinal tract. This characteristic is essential as an antigenic delivery system throughout the ocular mucosa. This, together with its elevated immune response, effective protection and intrinsic avirulence make them a suitable anti-Brucella vaccine candidate.


Assuntos
Vacina contra Brucelose/administração & dosagem , Nanopartículas/administração & dosagem , Nanopartículas/metabolismo , Vacinação/métodos , Administração Oftálmica , Animais , Sistemas de Liberação de Medicamentos , Feminino , Marcação por Isótopo/métodos , Maleatos , Camundongos , Camundongos Endogâmicos BALB C , Polímeros , Polivinil , Compostos Radiofarmacêuticos , Tecnécio , Distribuição Tecidual
14.
Comput Biol Med ; 40(1): 75-80, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19959163

RESUMO

PURPOSE: In order to measure spatial resolution of a PET tomograph in clinical conditions, this study describes and validates a method based on the recovery coefficient, a factor required to compensate underestimation in measured radioactivity concentration for small structures. METHODS: In a PET image, the recovery factors of radioactive spheres were measured and their comparison with simulated recovery coefficients yielded the tomographic spatial resolution. Following this methodology, resolution was determined in different surrounding media and several conditions for reconstruction, including clinical conditions for brain PET studies. All spatial resolution values were compared with those obtained using classical methods with point and line sources. RESULTS: In each considered condition, spatial resolution of the PET image estimated using the recovery coefficient showed good agreement with classical methods measurements, validating the procedure. CONCLUSION: Measurement of the recovery coefficient provides an assessment of tomographic spatial resolution, particularly in clinical studies conditions.


Assuntos
Simulação por Computador , Aumento da Imagem/métodos , Tomografia por Emissão de Pósitrons , Encéfalo/diagnóstico por imagem , Radioisótopos de Flúor , Humanos , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador
15.
Radiat Prot Dosimetry ; 133(4): 193-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19329512

RESUMO

The operation of electron linear accelerators (LINACs) and cyclotrons can produce a mixed gamma-neutron field composed of energetic neutrons coming directly from the source and scattered lower energy neutrons. The thermal neutron detection properties of a non-moderated coplanar-grid CdZnTe (CZT) gamma-ray detector close to an 18 MV electron LINAC and an 18 MeV proton cyclotron producing the radioisotope (18)F for positron emission tomography are investigated. The two accelerators are operated at conditions producing similar thermal neutron fluence rates of the order of 10(4) cm(-2) s(-1) at the measurement locations. The counting efficiency of the CZT detector using the prompt 558 keV photopeak following (113)Cd thermal neutron capture is evaluated and a good neutron detection performance is found at the two installations.


Assuntos
Cádmio , Ciclotrons/instrumentação , Nêutrons , Aceleradores de Partículas/instrumentação , Telúrio , Zinco , Raios gama , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA