Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Mikrochim Acta ; 186(12): 773, 2019 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-31720840

RESUMO

This review, with 201 references, describes the recent advancement in the application of carbonaceous nanomaterials as highly conductive platforms in electrochemical biosensing. The electrochemical biosensing is described in introduction by classifying biosensors into catalytic-based and affinity-based biosensors and statistically demonstrates the most recent published works in each category. The introduction is followed by sections on electrochemical biosensors configurations and common carbonaceous nanomaterials applied in electrochemical biosensing, including graphene and its derivatives, carbon nanotubes, mesoporous carbon, carbon nanofibers and carbon nanospheres. In the following sections, carbonaceous catalytic-based and affinity-based biosensors are discussed in detail. In the category of catalytic-based biosensors, a comparison between enzymatic biosensors and non-enzymatic electrochemical sensors is carried out. Regarding the affinity-based biosensors, scholarly articles related to biological elements such as antibodies, deoxyribonucleic acids (DNAs) and aptamers are discussed in separate sections. The last section discusses recent advancements in carbonaceous screen-printed electrodes as a growing field in electrochemical biosensing. Tables are presented that give an overview on the diversity of analytes, type of materials and the sensors performance. Ultimately, general considerations, challenges and future perspectives in this field of science are discussed. Recent findings suggest that interests towards 2D nanostructured electrodes based on graphene and its derivatives are still growing in the field of electrochemical biosensing. That is because of their exceptional electrical conductivity, active surface area and more convenient production methods compared to carbon nanotubes. Graphical abstract Schematic representation of carbonaceous nanomaterials used in electrochemical biosensing. The content is classified into non-enzymatic sensors and affinity/ catalytic biosensors. Recent publications are tabulated and compared, considering materials, target, limit of detection and linear range of detection.


Assuntos
Anticorpos/análise , Aptâmeros de Nucleotídeos/análise , Técnicas Biossensoriais , DNA/análise , Técnicas Eletroquímicas , Nanotubos de Carbono/química , Tamanho da Partícula , Propriedades de Superfície
2.
ACS Sens ; 6(3): 797-807, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33464874

RESUMO

Here, we report on an electrochemical biosensor based on core-shell structure of gold nano/micro-islands (NMIs) and electropolymerized imprinted ortho-phenylenediamine (o-PD) for detection of heart-fatty acid binding protein (H-FABP). The shape and distribution of NMIs (the core) were tuned by controlled electrodeposition of gold on a thin layer of electrochemically reduced graphene oxide (ERGO). NMIs feature a large active surface area to achieve a low detection limit (2.29 fg mL-1, a sensitivity of 1.34 × 1013 µA mM-1) and a wide linear range of detection (1 fg mL-1 to 100 ng mL-1) in PBS. Facile template H-FABP removal from the layer (the shell) in less than 1 min, high specificity against interference from myoglobin and troponin T, great stability at ambient temperature, and rapidity in detection of H-FABP (approximately 30 s) are other advantages of this biomimetic biosensor. The electrochemical measurements in human serum, human plasma, and bovine serum showed acceptable recovery (between 91.1 ± 1.7 and 112.9 ± 2.1%) in comparison with the ELISA method. Moreover, the performance of the biosensor in clinical serum showed lower detection time and limit of detection against lateral flow assay (LFA) rapid test kits, as a reference method. Ultimately, the proposed biosensor based on the core-shell structure of gold NMIs and MIP opens interesting avenues in the detection of proteins with low cost, high sensitivity and significantstability for clinical applications.


Assuntos
Técnicas Biossensoriais , Impressão Molecular , Animais , Bovinos , Ouro , Humanos , Ilhas , Polímeros Molecularmente Impressos
3.
Mater Sci Eng C Mater Biol Appl ; 68: 603-612, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27524060

RESUMO

Despite the attractive characteristics of three-dimensional pure hydroxyapatite (HA) scaffolds, due to their weak mechanical properties, researches have focused on the development of composite scaffolds via introducing suitable secondary components. The aim of this study was to develop, for the first time, three-dimensional HA-bredigite (Ca7MgSi4O16) scaffolds containing various amounts of bredigite nanopowder (0, 5, 10 and 15wt.%) using space holder technique. Transmission electron microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray diffraction spectroscopy were applied in order to study the morphology, fracture surface and phase compositions of nanopowders and scaffolds. Furthermore, the effects of scaffold composition on the mechanical properties, bioactivity, biodegradability, and cytotoxicity were also evaluated. Results showed that the composite scaffolds with average pore size in the range of 220-310µm, appearance porosity of 63.1-75.9% and appearance density of 1.1±0.04g/cm(3) were successfully developed, depending on bredigite content. Indeed, the micropore size of the scaffolds reduced with increasing bredigite content confirming that the sinterability of the scaffolds was improved. Furthermore, the compression strength and modulus of the scaffolds significantly enhanced via incorporation of bredigite content from 0 to 15wt.%. The composite scaffolds revealed superior bioactivity and biodegradability with increasing bredigite content. Moreover, MTT assay confirmed that HA-15wt.% bredigite scaffold significantly promoted cell proliferation compared to tissue culture plate (control) and HA scaffold. Based on these results, three-dimensional HA-bredigite scaffolds could be promising replacements for HA scaffolds in bone regeneration.


Assuntos
Amiantos Anfibólicos , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos , Durapatita , Nanoestruturas/química , Alicerces Teciduais/química , Amiantos Anfibólicos/química , Amiantos Anfibólicos/farmacocinética , Amiantos Anfibólicos/farmacologia , Substitutos Ósseos/química , Substitutos Ósseos/farmacocinética , Substitutos Ósseos/farmacologia , Linhagem Celular Tumoral , Avaliação Pré-Clínica de Medicamentos , Durapatita/química , Durapatita/farmacocinética , Durapatita/farmacologia , Humanos
4.
IEEE Trans Nanobioscience ; 13(4): 409-14, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25095258

RESUMO

Magnesium is one of the most critical elements in hard tissues regeneration and therefore causes speeding up the restoration of harmed bones, while high deterioration rate of magnesium in body fluid restricts it to be used as biodegradable implants. Alloying magnesium with some relatively nobler metals such as aluminium, zinc, rare earth elements, magnesium-bioceramics composites, and surface modification techniques are some of the routes to control magnesium corrosion rate. In this study AZ91 magnesium alloy had been coated by nanostructured hydroxyapatite via sol-gel dip coating and electrophoretical methods to survey the final barricade properties of the obtained coatings. In order to perform electrophoretic coating, powders were prepared by sol-gel method, and then the powders deposited on substrates utilizing direct current electricity. Zeta potentials of the electrophoresis suspensions were measured to determine a best mode for good quality coatings. Transmission Electron Microscopy (TEM), and Scanning Electron Microscopy (SEM) were used to confirm nanoscale dimension, and the uniformity of the nanostructured hydroxyapatite coating, respectively. Fourier Transform-Infrared and X-ray diffraction analysis were utilized for functional group and phase structure evaluation of the prepared coatings, correspondingly. Electrochemical corrosion tests were performed in SBF at 37±1 (°)C which revealed considerable increase in corrosion protection resistivity and corrosion current density for electrophoretic coated specimens versus sol-gel coated specimens. Results showed that both sol-gel and electrophoretical techniques seem to be suitable to coat magnesium alloys for biomedical applications but electrophoretic coating technique is a better choice due to the more homogeneity and more crystalline structure of the coating.


Assuntos
Ligas/química , Materiais Biocompatíveis/síntese química , Cristalização/métodos , Durapatita/química , Eletroforese/métodos , Magnésio/química , Nanopartículas Metálicas/química , Adsorção , Teste de Materiais , Nanopartículas Metálicas/ultraestrutura , Tamanho da Partícula , Transição de Fase , Propriedades de Superfície
5.
Mater Sci Eng C Mater Biol Appl ; 33(7): 3817-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23910282

RESUMO

Magnesium (Mg) alloys have been introduced as new generation of biodegradable orthopedic materials in recent years since it has been proved that Mg is one of the main minerals required for osseous tissue revival. The main goal of the present study was to establish a desired harmony between the necessities of orthopedic patient body to Mg(2+) ions and degradation rate of the Mg based implants as a new class of biodegradable/bioresorbable materials. This prospect was followed by providing a sol-gel derived nanostructured hydroxyapatite (n-HAp) coating on AZ91 alloy using dip coating technique. Phase structural analysis, morphology study, microstructure characterization, and functional group identification were performed using X-ray diffraction (XRD), Fourier transform infrared (FTIR), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) techniques. The prepared samples were immersed in simulated body fluid in order to study the formation of apatite-like precipitations, barricade properties of the n-HAp coating, and to estimate the dosage of released Mg(2+) ions within a specified and limited time of implantation. Electrochemical polarization tests were carried out to evaluate and compare the corrosion behavior of the n-HAp coated and uncoated samples. The changes of the in vitro pH values were also evaluated. Results posed the noticeable capability of n-HAp coating on stabilizing alkalization behavior and improving the corrosion resistance of AZ91 alloy. It was concluded that n-HAp coated AZ91 alloy could be a good candidate as a type of biodegradable implant material for biomedical applications.


Assuntos
Ligas/química , Materiais Revestidos Biocompatíveis/química , Durapatita/química , Magnésio/química , Nanoestruturas/química , Transição de Fase , Adesividade , Biodegradação Ambiental , Corrosão , Espectroscopia Dielétrica , Técnicas Eletroquímicas , Concentração de Íons de Hidrogênio , Imersão , Nanoestruturas/ultraestrutura , Pós , Espectrofotometria Atômica , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Vibração , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA