Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Med Inform Decis Mak ; 22(1): 289, 2022 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-36352382

RESUMO

BACKGROUND: With the availability of several similar medical devices performing the same function, choosing one for reimbursement is not easy, especially if purchased for a large number of patients. The objective of this project was to create a multicriteria decision analysis (MCDA) tool, that captures and compares all implantable medical devices' attributes, to provide an objective method for choosing among the available options in Egypt. METHOD: We conducted a systematic review and expert interviews, to identify the relevant criteria for inclusion in the tool. Subsequently, a workshop was conducted, that involved experts in procuring and tendering medical devices. Experts chose the criteria, ranked them, assigned weights and scoring functions for each criterion, and then created the draft tool. A pilot phase followed; then, another workshop was conducted to fine-tune the tool. We readjusted the tool based on experts' experience with the draft tool. RESULTS: The final tool included eight criteria, arranged according to their weightage: technical characteristics (29.4%), country of origin (19.5%), use in reference countries (14.9%), supply reliability (11.7%), previous use in tenders (9.0%), instant replacement within product variety (6.9%), pharmacovigilance (4.6%), and refund or replacement (4.0%). Each medical device was assessed on these eight criteria to achieve a final score, that was compared to the alternative devices' scores. Price is not included in the MCDA tool, but it will be added in the financial evaluation phase. CONCLUSION: Decisionmakers could use the MCDA tool, to make evidence-based and objective decisions for purchasing implantable devices, in the Egyptian public sector. Post price evaluation, the product with the best value will be chosen for reimbursement. HIGHLIGHTS: We created an MCDA tool to help decision makers choose between alternative implantable medical devices in Egypt. The MCDA tool includes eight criteria, where price is evaluated as a separate step. "Technical characteristics" and "country of origin" criteria carried the highest weights, thus representing approximately 50% of the decision.


Assuntos
Técnicas de Apoio para a Decisão , Setor Público , Humanos , Egito , Reprodutibilidade dos Testes , Próteses e Implantes
2.
Sci Rep ; 13(1): 1784, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36720994

RESUMO

Mediastinal lymph node fine needle aspiration (MLN-FNA) is a common procedure; however, the physician factor in pathological category, and anatomical site are not routinely assessed. Cytology reports for endobronchial ultrasound (EBUS)/endoscopic ultrasound (EUS) MLN-FNA specimens (8846) were retrieved for July 2012-Dec 2019, classified by hierarchical free text string match algorithm into 51 diagnostic categories, four mutually exclusive diagnostic groups (benign |suspicious |malignant |insufficient), and 24 anatomical sites. Pathologist and submitting physician/surgeon bias were assessed using logistic regression and funnel plots|control charts centered on the group median (diagnostic/capture) rate. Eleven pathologists and seven submitting physician/surgeon were involved in more than 250 specimens each. Overall, the MLN-FNAs were benign|suspicious|malignant|insufficient in 46%|4%|25%|24% of specimens. Percent malignant (number of samples) varied by station; 7| 4R| 4L| 2R| 10R| 11R| 11L were respectively 21%(3,101), 27%(2,453), 19%(1,289), 41%(435), 27%(497), 24%(357), 26%(229). The number of outlier (P < 0.05/P < 0.001) pathologists of 11 from the group median rate for benign|suspicious|malignant|insufficient was 0/0| 3/1| 0/0| 3/0 respectively. The outlier (P < 0.05/P < 0.001) submitting physicians/surgeons of 7 for benign|suspicious|malignant|insufficient was 3/2| 2/2| 3/2| 3/2 respectively. The physician and anatomical site are significant predictors of MLN-FNA pathology.


Assuntos
Cirurgiões , Humanos , Algoritmos , Estudos Transversais , Linfonodos/diagnóstico por imagem , Patologistas , Biópsia por Agulha Fina
3.
Nat Prod Res ; 36(22): 5766-5771, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34894897

RESUMO

Withania somnifera, Angelica sinensis, Glycyrrhiza glabra, and Simmondsia chinensis were acquired from the Egyptian market, profiled for their chemical constituents, screened for the in-vitro MAO-B inhibitory activity and evaluated for the total phenolic content. Thirty compounds were characterized in the selected herbs using HPLC-MS/MS. In-vitro MAO-B inhibitory activity and total phenolic content of the acquired herbs were compared with those of a prepared herbal formula consisting of a mixture of equal amounts of the four mentioned herbs. The most potent MAO-B inhibitory activity was exerted by the methanol extract of the prepared formula (IC50 of 712.19 ± 13.90 ng/mL) compared to selegiline (IC50 of 581.69 ± 11.35 ng/mL). The highest value of the total phenolic content was shown by Angelica sinensis methanolic extract (76.15 ± 0.1 mg/g) followed by Glycyrrhiza glabra methanolic extract (65.74 ± 0.1 mg/g), then the mixture's methanolic extract of the four herbs (37.04 ± 0.1 mg/g).


Assuntos
Monoaminoxidase , Doença de Parkinson , Humanos , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem , Egito , Fenóis/análise , Plantas , Extratos Vegetais/farmacologia , Metanol
4.
Diabetes ; 55(11): 2931-8, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17065328

RESUMO

We have developed a magnetic resonance imaging (MRI) technique for imaging Feridex (superparamagnetic iron oxide [SPIO])-labeled islets of Langerhans using a standard clinical 1.5-Tesla (T) scanner and employing steady-state acquisition imaging sequence (3DFIESTA). Both porcine and rat islets were labeled with SPIO by a transfection technique using a combination of poly-l-lysine and electroporation. Electron microscopy demonstrated presence of SPIO particles within the individual islet cells, including beta-cells and particles trapped between cell membranes. Our labeling method produced a transfection rate of 860 pg to 3.4 ng iron per islet, dependent on the size of the islet. The labeling procedure did not disrupt either the function or viability of the islets. In vitro 3DFIESTA magnetic resonance images of single-labeled islets corresponded with their optical images. In vivo T2*-weighted scan using 1.5 T detected as few as 200 SPIO-labeled islets transplanted under rat kidney capsule, which correlated with immunohistochemistry of the transplant for insulin and iron. Ex vivo 3DFIESTA images of kidneys containing 200, 800 or 2,000 SPIO-labeled islet isografts showed good correlation between signal loss and increasing numbers of islets. These data provide evidence that islets can be labeled with SPIO and imaged using clinically available 1.5- T MRI.


Assuntos
Transplante das Ilhotas Pancreáticas/fisiologia , Ilhotas Pancreáticas/citologia , Imageamento por Ressonância Magnética/métodos , Animais , Animais Recém-Nascidos , Sobrevivência Celular , Eletroporação , Complexo Ferro-Dextran , Ilhotas Pancreáticas/ultraestrutura , Masculino , Modelos Animais , Ratos , Ratos Endogâmicos Lew , Sensibilidade e Especificidade , Ensaio de Cápsula Sub-Renal , Suínos , Transplante Autólogo
5.
Cancer Res ; 69(21): 8326-31, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19843857

RESUMO

The metastatic cell population, ranging from solitary cells to actively growing metastases, is heterogeneous and unlikely to respond uniformly to treatment. However, quantification of the entire experimental metastatic cell population in whole organs is complicated by requirements of an imaging modality with the large field of view and high spatial resolution necessary to detect both single cells and metastases in the same organ. Thus, it is difficult to assess differential responses of these distinct metastatic populations to therapy. Here, we develop a magnetic resonance imaging (MRI) technique capable of quantifying the full population of metastatic cells in a secondary organ. B16F1 mouse melanoma cells were labeled with micron-sized iron oxide particles (MPIO) and injected into mouse liver via the mesenteric vein. Livers were removed immediately or at day 9 or 11, following doxorubicin or vehicle control treatment, and imaged using a 3T clinical magnetic resonance scanner and custom-built gradient coil. Both metastases (>200 microm) and MPIO-labeled single cells were detected and quantified from MR images as areas of hyperintensity or hypointensity (signal voids), respectively. We found that 1mg/kg doxorubicin treatment inhibited metastasis growth (n = 11 per group; P = 0.02, t test) but did not decrease the solitary metastatic cell population in the same livers (P > 0.05). Thus, the technique presented here is capable of quickly quantifying the majority of the metastatic cell population, including both growing metastases and solitary cells, in whole liver by MRI and can identify differential responses of growing metastases and solitary cells to therapy.


Assuntos
Compostos Férricos , Imageamento Tridimensional , Neoplasias Hepáticas Experimentais/secundário , Imageamento por Ressonância Magnética , Melanoma Experimental/secundário , Animais , Antibióticos Antineoplásicos/uso terapêutico , Meios de Contraste , Doxorrubicina/uso terapêutico , Feminino , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas Experimentais/tratamento farmacológico , Melanoma Experimental/tratamento farmacológico , Camundongos , Camundongos Endogâmicos C57BL , Prognóstico
6.
MAGMA ; 21(4): 251-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18581153

RESUMO

INTRODUCTION: The use of MRI with iron-based magnetic nanoparticles for imaging cells is a rapidly growing field of research. We have recently reported that single iron-labeled cells could be detected, as signal voids, in vivo in mouse brains using a balanced steady-state free precession imaging sequence (b-SSFP) and a customized microimaging system at 1.5 T. METHODS: In the current study we assess the benefits, and challenges, of using a higher magnetic field strength for imaging iron-labeled cells with b-SSFP, using ex vivo mouse brain specimens imaged with near identical systems at 1.5 and 3.0 T. RESULTS: The substantial banding artifact that appears in 3 T b-SSFP images was readily minimized with RF phase cycling, allowing for banding-free b-SSFP images to be compared between the two field strengths. This study revealed that with an optimal 3 T b-SSFP imaging protocol, more than twice as many signal voids were detected as with 1.5 T. CONCLUSION: There are several factors that contributed to this important result. First, a greater-than-linear SNR gain was achieved in mouse brain images at 3 T. Second, a reduction in the bandwidth, and the associated increase in repetition time and SNR, produced a dramatic increase in the contrast generated by iron-labeled cells.


Assuntos
Encéfalo/citologia , Ferro/química , Animais , Artefatos , Linhagem Celular Tumoral , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Nanopartículas Metálicas , Camundongos , Camundongos Nus
7.
Magn Reson Med ; 56(5): 1001-10, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17029229

RESUMO

Metastasis (the spread of cancer from a primary tumor to secondary organs) is responsible for most cancer deaths. The ability to follow the fate of a population of tumor cells over time in an experimental animal would provide a powerful new way to monitor the metastatic process. Here we describe a magnetic resonance imaging (MRI) technique that permits the tracking of breast cancer cells in a mouse model of brain metastasis at the single-cell level. Cancer cells that were injected into the left ventricle of the mouse heart and then delivered to the brain were detectable on MR images. This allowed the visualization of the initial delivery and distribution of cells, as well as the growth of tumors from a subset of these cells within the whole intact brain volume. The ability to follow the metastatic process from the single-cell stage through metastatic growth, and to quantify and monitor the presence of solitary undivided cells will facilitate progress in understanding the mechanisms of brain metastasis and tumor dormancy, and the development of therapeutics to treat this disease.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/secundário , Neoplasias da Mama/diagnóstico , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Células Neoplásicas Circulantes/patologia , Animais , Proliferação de Células , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Nus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA