Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Neonatology ; 121(3): 288-297, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38467119

RESUMO

BACKGROUND: A major proportion of preterm neonates require positive pressure ventilation (PPV) immediately after delivery. PPV may be administered through a face mask (FM) or nasal prongs. Current literature indicates that either of these are associated with similar outcomes. SUMMARY: Nonetheless, FM remains the most utilized and the best choice. However, most available FM sizes are too large for extremely preterm infants, which leads to mask leak and ineffective PPV. Challenges to providing effective PPV include poor respiratory drive, complaint chest wall, weak thoracic muscle, delayed liquid clearance, and surfactant deficiency in preterm infants. Mask leak, airway obstruction, poor technique, and inappropriate size are correctable causes of ineffective PPV. Visual assessment of chest rise is often used to assess the efficacy of PPV. However, its accuracy is debatable. Though end tidal CO2 may adjudge the effectiveness of PPV, clinical studies are limited. The compliance of a preterm lung is highly dynamic. The inflating pressure set on T-piece is constant throughout the resuscitation, but the lung volume and dynamics changes with every breath. This leads to huge fluctuations of tidal volume delivery and can trigger inflammatory cascade in preterm infants leading to brain and lung injury. Respiratory function monitoring in the delivery room has potential for guiding and optimizing delivery room resuscitation. This is, however, limited by high costs, complex information that is difficult to interpret during resuscitation, and absence of clinical trials. KEY MESSAGES: This review summarizes the existing literature on PPV in preterm infants, the various aspects related to it such as the pathophysiology, interfaces, devices utilized to deliver it, appropriate technique, emerging technologies, and future directions.


Assuntos
Salas de Parto , Recém-Nascido Prematuro , Respiração com Pressão Positiva , Humanos , Recém-Nascido , Respiração com Pressão Positiva/métodos , Máscaras , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
2.
BMJ Paediatr Open ; 8(1)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769048

RESUMO

BACKGROUND: There exists limited agreement on the recommendations for the treatment of transitional circulatory instability (TCI) in preterm neonates OBJECTIVE: To compare the efficacy of various interventions used to treat TCI METHODS: Medline and Embase were searched from inception to 21st July 2023. Two authors extracted the data independently. A Bayesian random effects network meta-analysis was used. Recommendations were formulated using the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. INTERVENTIONS: Dopamine, dobutamine, epinephrine, hydrocortisone, vasopressin, milrinone, volume and placebo. MAIN OUTCOME MEASURES: Mortality, major brain injury (MBI) (intraventricular haemorrhage > grade 2 or cystic periventricular leukomalacia), necrotising enterocolitis (NEC) ≥stage 2 and treatment response (as defined by the author). RESULTS: 15 Randomized Controlled Trials (RCTs) were included from the 1365 titles and abstracts screened. Clinical benefit or harm could not be ruled out for the critical outcome of mortality. For the outcome of MBI, epinephrine possibly decreased the risk when compared to dobutamine and milrinone (very low certainty). Epinephrine was possibly associated with a lesser risk of NEC when compared with dopamine, dobutamine, hydrocortisone and milrinone (very low certainty). Dopamine was possibly associated with a lesser risk of NEC when compared with dobutamine (very low certainty). Vasopressin possibly decreased the risk of NEC compared with dopamine, dobutamine, hydrocortisone and milrinone (very low certainty). Clinical benefit or harm could not be ruled out for the outcome response to treatment. CONCLUSIONS: Epinephrine may be used as the first-line drug in preterm neonates with TCI, the evidence certainty being very low. We suggest future trials evaluating the management of TCI with an emphasis on objective criteria to define it.


Assuntos
Cardiotônicos , Recém-Nascido Prematuro , Metanálise em Rede , Vasoconstritores , Humanos , Recém-Nascido , Cardiotônicos/uso terapêutico , Vasoconstritores/uso terapêutico , Doenças do Prematuro/tratamento farmacológico , Doenças do Prematuro/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Dobutamina/uso terapêutico , Dobutamina/administração & dosagem
3.
Pediatr Pulmonol ; 58(3): 643-652, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36484311

RESUMO

Approximately 46% of the 5.2 million annual under-5 deaths derive from neonatal conditions commonly associated with hypoxemia or acute respiratory distress. It has been estimated that 98% of these deaths occur in low- and middle-income countries (LMICs). Effective implementation of noninvasive respiratory support at all levels of healthcare could significantly reduce neonatal mortality. Several factors limit the widespread and effective implementation of noninvasive respiratory support in LMICs, including inadequate infrastructure, lack of proper instrumentation, shortage of skilled staff, costly disposables, and difficulties in the supply of consumables and spare parts. The aim of this state-of-the-art paper is to provide a detailed evaluation of the commercially available devices providing noninvasive respiratory support in LMICs, focusing on bubblecontinuous positive airway pressure (bCPAP). bCPAP might be administrated using a variety of different commercial devices, including devices specifically designed for LMICs, as well as using self-made systems. We described all the equipment required for safe and effective implementation of bCPAP, including air and oxygen sourced, pressure-reducing valves and flowmeters, air-oxygen blending systems, humidifiers, respiratory support devices, patient circuits, and airway interfaces. Specifically, we critically evaluated the advantages and disadvantages of various existing solutions within the context of low-resource settings.


Assuntos
Síndrome do Desconforto Respiratório do Recém-Nascido , Síndrome do Desconforto Respiratório , Recém-Nascido , Lactente , Humanos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Países em Desenvolvimento , Pressão Positiva Contínua nas Vias Aéreas , Oxigênio
4.
Artigo em Inglês | MEDLINE | ID: mdl-35954977

RESUMO

Beta-blockers are often used during pregnancy to treat cardiovascular diseases. The described neonatal side effects of maternal beta-blocker use are hypoglycemia and bradycardia, but the evidence base for these is yet to be evaluated comprehensively. Hence, this systematic review and meta-analysis was performed to evaluate the potential increased risk for hypoglycemia and bradycardia in neonates exposed to beta-blockers in utero or during lactation. A systematic search of English-language human studies was conducted until 21 April 2021. Both observational studies and randomized controlled trials investigating hypoglycemia and/or bradycardia in neonates following beta-blocker exposure during pregnancy and lactation were included. All articles were screened by two authors independently and eligible studies were included. Pair-wise and proportion-based meta-analysis was conducted and the certainty of evidence (CoE) was performed by standard methodologies. Of the 1.043 screened articles, 55 were included in this systematic review. Our meta-analysis showed a probable risk of hypoglycemia (CoE-Moderate) and possible risk of bradycardia (CoE-Low) in neonates upon fetal beta-blocker exposure. Therefore, we suggest the monitoring of glucose levels in exposed neonates until 24 h after birth. Due to the limited clinical implication, monitoring of the heart rate could be considered for 24 h. We call for future studies to substantiate our findings.


Assuntos
Hipoglicemia , Doenças do Recém-Nascido , Antagonistas Adrenérgicos beta/efeitos adversos , Bradicardia/induzido quimicamente , Bradicardia/tratamento farmacológico , Feminino , Humanos , Hipoglicemia/induzido quimicamente , Recém-Nascido , Lactação , Gravidez
5.
J Matern Fetal Neonatal Med ; 34(9): 1508-1511, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-31238756

RESUMO

The diagnosis of a right atrial mass in a neonate should be treated as an emergency. There are three major differential diagnoses for a right atrial mass-thrombus, infectious vegetation, and myxoma. Embolization of the mass can result in life-threatening complications and hence timely diagnosis and treatment is vital. This case series describes the clinical course, management, and outcome of four neonates who presented with a right atrial mass.


Assuntos
Cardiopatias , Mixoma , Trombose , Diagnóstico Diferencial , Átrios do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Mixoma/diagnóstico , Trombose/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA