Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Card Fail ; 28(11): 1584-1592, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35597511

RESUMO

BACKGROUND: Multiple studies have shown better outcomes for simultaneous heart-kidney transplant (sHKT) than for isolated orthotopic heart transplant (iOHT) in recipients with chronic kidney disease (CKD). However, outcomes in patients supported by durable left ventricular assist devices (LVADs) have not been well studied. METHODS: Patients with durable LVADs and stage 3 or higher CKD (eGFR < 60 mL/min/1.73 m2) undergoing iOHT or sHKT between 2008 and 2020 were identified from the United Network for Organ Sharing registry. A Kaplan-Meier survival analysis with associated log-rank test was conducted to compare post-transplant survival rates. Multivariable modeling was used to identify risk-adjusted predictors of 1 year post-transplant mortality. RESULTS: We identified 4375 patients; 366 underwent sHKT, and 4009 underwent iOHT. The frequency of sHKT increased during the study period. The 1-year post-transplant survival rate was worse in patients after sHKT than in patients after iOHT (80.3% vs 88.3%; P < 0.001) and persisted up to 5 years post-transplant (P = 0.001). sHKT recipients were more likely to require dialysis after transplantation and had longer hospital lengths of stay (P < 0.001). Multivariable analysis showed that sHKT remained an independent risk factor for mortality at 1 year (OR 1.58; P = 0.002). CONCLUSIONS: sHKT is becoming more common in patients with durable LVADs. Compared with iOHT, patients with sHKTs have worse short- and long-term survival rates and are more likely to require post-transplant dialysis.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Transplante de Rim , Insuficiência Renal Crônica , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Renal Crônica/etiologia
2.
J Heart Lung Transplant ; 42(2): 145-149, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36481112

RESUMO

Equipoise remains about how best to measure cardiac output (CO) in patients with left ventricular assist devices (LVAD). In this study, direct Fick CO was compared with thermodilution (TD) and indirect Fick (iFick) CO in 61 LVAD patients. TD and LaFarge iFick showed moderate correlation with direct Fick (R2 = 0.49 and R2 = 0.38, p < 0.001 for both), while Dehmer and Bergstra iFick showed poor correlation with direct Fick (R2 = 0.29 and R2 = 0.31, p < 0.001 for both). Absolute bias between all CO estimation techniques and direct Fick CO was lowest for TD compared to iFick methods but significant for all methods. All methods tended to overestimate CO compared to direct Fick, with greatest overestimation present in those with the lowest measured direct Fick CO. Bias and frequency of significant discrepancy were least using TD and Lafarge iFick CO estimation methods in this study, with TD CO demonstrating modestly better correlation and less heteroscedasticity compared to Lafarge.


Assuntos
Coração Auxiliar , Humanos , Débito Cardíaco , Termodiluição/métodos , Consumo de Oxigênio , Monitorização Fisiológica
3.
ASAIO J ; 69(3): 315-323, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36191552

RESUMO

Late right heart failure (LRHF) following left ventricular assist device (LVAD) implantation remains poorly characterized and challenging to predict. We performed a multicenter retrospective study of LRHF in 237 consecutive adult LVAD patients, in which LRHF was defined according to the 2020 Mechanical Circulatory Support Academic Research Consortium guidelines. Clinical and hemodynamic variables were assessed pre- and post-implant. Competing-risk regression and Kaplan-Meier survival analysis were used to assess outcomes. LRHF prediction was assessed using multivariable logistic and Cox proportional hazards regression. Among 237 LVAD patients, 45 (19%) developed LRHF at a median of 133 days post-LVAD. LRHF patients had more frequent heart failure hospitalizations ( p < 0.001) alongside other complications. LRHF patients did not experience reduced bridge-to-transplant rates but did suffer increased mortality (hazard ratio 1.95, 95% confidence interval [CI] 1.11-3.42; p = 0.02). Hemodynamically, LRHF patients demonstrated higher right atrial pressure, mean pulmonary arterial pressure, and pulmonary vascular resistance (PVR), but no difference in pulmonary arterial wedge pressure. History of early right heart failure, blood urea nitrogen (BUN) > 35 mg/dl at 1 month post-LVAD, and diuretic requirements at 1 month post-LVAD were each significant, independent predictors of LRHF in multivariable analysis. An LRHF prediction risk score incorporating these variables predicted LRHF with excellent discrimination (log-rank p < 0.0001). Overall, LRHF post-LVAD is more common than generally appreciated, with significant morbidity and mortality. Elevated PVR and precapillary pulmonary pressures may play a role. A risk score using early right heart failure, elevated BUN, and diuretic requirements 1 month post implant predicted the development of LRHF.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Adulto , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Insuficiência Cardíaca/complicações , Pressão Propulsora Pulmonar , Fatores de Risco , Resultado do Tratamento
4.
J Heart Lung Transplant ; 41(12): 1716-1726, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35934606

RESUMO

BACKGROUND: Early right heart failure (RHF) remains a major source of morbidity and mortality after left ventricular assist device (LVAD) implantation, yet efforts to predict early RHF have proven only modestly successful. Pharmacologic unloading of the left ventricle may be a risk stratification approach allowing for assessment of right ventricular and hemodynamic reserve. METHODS: We performed a multicenter, retrospective analysis of patients who had undergone continuous-flow LVAD implantation from October 2011 to April 2020. Only those who underwent vasodilator testing with nitroprusside during their preimplant right heart catheterization were included (n = 70). Multivariable logistic regression was used to determine independent predictors of early RHF as defined by Mechanical Circulatory Support-Academic Research Consortium. RESULTS: Twenty-seven patients experienced post-LVAD early RHF (39%). Baseline clinical characteristics were similar between patients with and without RHF. Patients without RHF, however, achieved higher peak stroke volume index (SVI) (30.1 ± 8.8 vs 21.7 ± 7.4 mL/m2; p < 0.001; AUC: 0.78; optimal cut-point: 22.1 mL/m2) during nitroprusside administration. Multivariable analysis revealed that peak SVI was significantly associated with early RHF, demonstrating a 16% increase in risk of early RHF per 1 ml/m2 decrease in SVI. A follow up cohort of 10 consecutive patients from July 2020 to October 2021 resulted in all patients being categorized appropriately in regards to early RHF versus no RHF according to peak SVI. CONCLUSION: Peak SVI with nitroprusside administration was independently associated with post-LVAD early RHF while resting hemodynamics were not. Vasodilator testing may prove to be a strong risk stratification tool when assessing LVAD candidacy though additional prospective validation is needed.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Estudos Retrospectivos , Nitroprussiato , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Volume Sistólico , Vasodilatadores/uso terapêutico
5.
J Am Med Inform Assoc ; 27(8): 1300-1305, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32470974

RESUMO

The US Department of Veterans Affairs (VA) is using an automated short message service application named "Annie" as part of its coronavirus disease 2019 (COVID-19) response with a protocol for coronavirus precautions, which can help the veteran monitor symptoms and can advise the veteran when to contact his or her VA care team or a nurse triage line. We surveyed 1134 veterans on their use of the Annie application and coronavirus precautions protocol. Survey results support what is likely a substantial resource savings for the VA, as well as non-VA community healthcare. Moreover, the majority of veterans reported at least 1 positive sentiment (felt more connected to VA, confident, or educated and/or felt less anxious) by receiving the protocol messages. The findings from this study have implications for other healthcare systems to help manage a patient population during the coronavirus pandemic.


Assuntos
Infecções por Coronavirus , Pandemias , Pneumonia Viral , Envio de Mensagens de Texto , Veteranos , Betacoronavirus , COVID-19 , Infecções por Coronavirus/diagnóstico , Árvores de Decisões , Humanos , Aplicativos Móveis , Pneumonia Viral/diagnóstico , SARS-CoV-2 , Telemedicina , Triagem , Estados Unidos , United States Department of Veterans Affairs
6.
Appl Clin Inform ; 10(5): 972-980, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31875647

RESUMO

BACKGROUND: The introduction of the electronic health record (EHR) has had a significant impact on provider-patient interactions, particularly revolving around patient-centeredness. More research is needed to understand the provider perspective of this interaction. OBJECTIVES: Our objective was to obtain provider feedback on a new exam room design compared with the one already in use with respect to the computing layout, which included a wall-mounted monitor for ease of (re)-positioning. An additional objective was to understand elements of exam room design and computing that were highly valued. METHODS: Semistructured interviews were conducted with 28 providers from several health care organizations. Interviews were audio recorded and transcribed for analysis. We used an inductive coding approach to abstract recurrent themes from the data. RESULTS: Our analysis revealed several themes organized around exam room layout, exam room computing, and provider workflow. We report frequency of occurrence of the coded data for computer accessories, computing usefulness, computer mobility, documentation habits, form factor, layout preference, patient interaction, screen sharing, and work habits. CONCLUSION: Providers in our study preferred exam room design to promote flexibility, mobility, and body orientation directed toward the patient. Providers also expressed the need for exam room design to support varying work habits and preferences, including whether to share the computer screen or not.


Assuntos
Registros Eletrônicos de Saúde , Pessoal de Saúde/estatística & dados numéricos , Atenção Primária à Saúde , Adulto , Feminino , Pessoal de Saúde/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Relações Médico-Paciente , Inquéritos e Questionários , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA