BACKGROUND: In neonatal intensive care units (NICUs), hygiene and disinfection measures are pivotal to protect neonates from nosocomial infections. This study aimed to evaluate the efficacy of the classical incubators disinfection procedure and to follow-up neonates housed in the incubators for the development of late-onset sepsis (LOS). METHODS: In a tertiary NICU, 20 incubators were monitored for bacterial contamination at three times: before disinfection, after disinfection, and 24 h after turning on and housing a new neonate. Clinical data of neonates housed in these incubators were retrieved from the medical records. RESULTS: All 20 incubators were contaminated at the 3 times of the study, mainly on mattresses and balances. Coagulase-negative Staphylococci, Enterococcus, and Bacillus-resisted disinfection while enterobacteria and Staphylococcus aureus were eradicated. After 24 h, the bacterial colonisation was similar to the one observed before disinfection. The bacteria isolated on incubators were also found on the caregivers' hands. During the study, two preterm neonates developed a LOS involving a bacterial species that has been previously isolated in their incubator. CONCLUSION: Pathogenic contaminants persist on incubators despite disinfection and represent a risk for subsequent infection in preterm neonates. Improvements are needed concerning both the disinfection process and incubator design. IMPACT: Procedures of disinfection that are usually recommended in NICUs do not allow for totally eradicating bacteria from incubators. Preterm neonates are housed in incubators colonised with potentially pathogenic bacteria. The control of nosocomial infections in NICUs requires further researches concerning mechanisms of bacterial persistence and ways to fight against environmental colonisation.


Assuntos
Desinfecção , Incubadoras para Lactentes/microbiologia , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Sepse/microbiologia
2.
Antimicrob Resist Infect Control ; 12(1): 18, 2023 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-36927466

RESUMO

BACKGROUND: In neonatal intensive care units (NICUs), neonates requiring medical care after birth, including very vulnerable preterm infants, are housed in incubators. Previous studies have reported that the standard chemical disinfection measures used to disinfect these incubators are insufficient to eradicate contaminating bacteria, leading to a worrying infectious risk for preterm neonates. This study aimed to evaluate the efficacy of a disinfection method based on steam pulverization to eradicate the persistent bacterial contamination in such incubators. METHODS: In a tertiary NICU, 20 incubators were monitored qualitatively for bacterial contamination at five different sites (the rubber grommet, the left door handles, the temperature adjustment button, the mattress and the scale) using a culture method at three times: before and after steam pulverization then 24 h after turning on and housing a new neonate. Clinical data of neonates housed in each incubator were retrieved from the medical records to identify potential occurrence of late onset sepsis (LOS). RESULTS: Just after steam pulverization, only two incubators were free from bacteria. Before disinfection 87% of all the samples were contaminated compared to 61% after disinfection. After 24 h, the proportion of contaminated samples reached 85%. Mattresses and scales were the most frequently contaminated incubator sites with respectively 90% and 80% positive samples after disinfection compared to 100% and 90% before disinfection. Coagulase-negative staphylococci, Enterococcus, Enterobacteria and Bacillus resisted disinfection and were identified on respectively 90%, 20%, 5% and 45% of incubators just after disinfection. Three preterm neonates developed LOS after being housed in a disinfected incubator but the bacterial species involved have not been identified in their incubator after disinfection. In two cases, the bacterium had been isolated from the mattress 24 h after housing the infected patient. CONCLUSION: Steam pulverization is not sufficient to eradicate bacterial contamination of incubators. These results highlight the urgent need for an effective disinfection method, especially for mattresses that are in constant contact with patients. In parallel, new incubator designs and mattress protections must be developed.


Assuntos
Desinfecção , Incubadoras , Vapor , Bactérias , Desinfecção/métodos , Incubadoras/microbiologia , Unidades de Terapia Intensiva Neonatal