Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Z Med Phys ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38184375

RESUMO

INTRODUCTION: Patient specific quality assurance (QA) in MR-Linacs can be performed with MR-compatible ion chamber arrays. However, the presence of a static magnetic field can alter the angular response of such arrays substantially. This works investigates the suitability of two ion chamber arrays, an air-filled and a liquid-filled array, for patient specific QA at a 0.35 T MR-Linac using a static phantom. METHODS: In order to study the angular response, the two arrays were placed in a static, solid phantom and irradiated with 9.96 × 9.96 cm2 fields every 10° beam angle at a 0.35 T MR-Linac. Measurements were compared to the TPS calculated dose in terms of gamma passing rate and relative dose to the central chamber. 20 patient specific quality assurance plans were measured using the liquid-filled array. RESULTS: The air-filled array showed asymmetric angular response changes of central chamber dose of up to 18% and down to local 3 mm / 3% gamma rates of 20%, while only minor differences within 3% (excluding parallel irradiation and beams through the couch edges) were found for the liquid-filled ion chamber array without rotating the phantom. Patient plan QA using the liquid-filled array yielded a median local 3 mm / 3% 3D gamma passing rate of 99.8% (range 96.9%-100%). CONCLUSION: A liquid-filled ionization chamber array in combination with a static phantom can be used for efficient patient specific plan QA in a single measurement set-up in a 0.35 T MR-Linac, while the air-filled ion chamber array phantom shows large angular response changes and has its limitations regarding patient specific QA measurements.

2.
Biomed Phys Eng Express ; 9(6)2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37591227

RESUMO

The combination of magnetic resonance (MR) imaging and linear accelerators (linacs) into MR-Linacs enables continuous MR imaging and advanced gated treatments of patients. Previously, a dose-rate transient (∼8% reduced dose rate during the initial 0.5 s of each beam) was identified for a Viewray MRIdian MR-Linac (Klavsenet al2022Radiation Measurement106759). Here, the dose-rate transient is studied in more detail at four linacs of the same type at different hospitals. The implications of dose-rate transients were examined for gated treatments. The dose-rate transients were investigated using dose-per pulse measurements with organic plastic scintillators in three experiments: (i) A gated treatment with the scintillator placed in a moving target in a dynamic phantom, (ii) a gated treatment with the same dynamic conditions but with the scintillator placed in a stationary target, and (iii) measurements in a water-equivalent material to examine beam quality deviations at a dose-per-pulse basis. Gated treatments (i) compared with non-gated treatments with a static target in the same setup showed a broadening of accumulated dose profiles due to motion (dose smearing). The linac with the largest dose-rate transient had a reduced accumulated dose of up to (3.1 ± 0.65) % in the center of the PTV due to the combined dose smearing and dose-rate transient effect. Dose-rate transients were found to vary between different machines. Two MR-Linacs showed initial dose-rate transients that could not be identified from conventional linearity tests. The source of the transients includes an initial change in photon fluence rate and an initial change in x-ray beam quality. For gated treatments, this caused a reduction of more than 1% dose delivered at the central part of the beam for the studied, cyclic-motion treatment plan. Quality assurance of this effect should be considered when gated treatment with the Viewray MRIdian is implemented clinically.


Assuntos
Fótons , Plásticos , Humanos , Frequência Cardíaca , Movimento (Física) , Imagens de Fantasmas
3.
Radiat Oncol ; 17(1): 59, 2022 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-35346270

RESUMO

BACKGROUND: Stereotactic body radiotherapy (SBRT) is an established local treatment method for patients with hepatic oligometastasis or oligoprogression. Liver metastases often occur in close proximity to radiosensitive organs at risk (OARs). This limits the possibility to apply sufficiently high doses needed for optimal local control. Online MR-guided radiotherapy (oMRgRT) is expected to hold potential to improve hepatic SBRT by offering superior soft-tissue contrast for enhanced target identification as well as the benefit of gating and daily real-time adaptive treatment. The MAESTRO trial therefore aims to assess the potential advantages of adaptive, gated MR-guided SBRT compared to conventional SBRT at a standard linac using an ITV (internal target volume) approach. METHODS: This trial is conducted as a prospective, randomized, three-armed phase II study in 82 patients with hepatic metastases (solid malignant tumor, 1-3 hepatic metastases confirmed by magnetic resonance imaging (MRI), maximum diameter of each metastasis ≤ 5 cm (in case of 3 metastases: sum of diameters ≤ 12 cm), age ≥ 18 years, Karnofsky Performance Score ≥ 60%). If a biologically effective dose (BED) ≥ 100 Gy (α/ß = 10 Gy) is feasible based on ITV-based planning, patients will be randomized to either MRgRT or ITV-based SBRT. If a lesion cannot be treated with a BED ≥ 100 Gy, the patient will be treated with MRgRT at the highest possible dose. Primary endpoint is the non-inferiority of MRgRT at the MRIdian Linac® system compared to ITV-based SBRT regarding hepatobiliary and gastrointestinal toxicity CTCAE III or higher. Secondary outcomes investigated are local, locoregional (intrahepatic) and distant tumor control, progression-free survival, overall survival, possible increase of BED using MRgRT if the BED is limited with ITV-based SBRT, treatment-related toxicity, quality of life, dosimetric parameters of radiotherapy plans as well as morphological and functional changes in MRI. Potential prognostic biomarkers will also be evaluated. DISCUSSION: MRgRT is known to be both highly cost- and labor-intensive. The MAESTRO trial aims to provide randomized, higher-level evidence for the dosimetric and possible consecutive clinical benefit of MR-guided, on-table adaptive and gated SBRT for dose escalation in critically located hepatic metastases adjacent to radiosensitive OARs. TRIAL REGISTRATION: The study has been prospectively registered on August 30th, 2021: Clinicaltrials.gov, "Magnetic Resonance-guided Adaptive Stereotactic Body Radiotherapy for Hepatic Metastases (MAESTRO)", NCT05027711.


Assuntos
Neoplasias Hepáticas , Radiocirurgia , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Estudos Prospectivos , Qualidade de Vida , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA