Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 144(23): 6914-6921, 2019 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-31657376

RESUMO

Monitoring soluble immune checkpoints in circulating fluids has the potential for minimally-invasive diagnostics and personalised therapy in precision medicine. Yet, the sensitive detection of multiple immune checkpoints from small volumes of liquid biopsy samples is challenging. In this study, we develop a multiplexed immune checkpoint biosensor (MICB) for parallel detection of soluble immune checkpoints PD-1, PD-L1, and LAG-3. MICB integrates a microfluidic sandwich immunoassay using engineered single chain variable fragments and alternating current electrohydrodynamic in situ nanofluidic mixing for promoting biosensor-target interaction and reducing non-specific non-target binding. MICB provides advantages of simultaneous analysis of up to 28 samples in <2 h, requires as little as a single sample drop (i.e., 20 µL) per target immune checkpoint, and applies high-affinity yeast cell-derived single chain variable fragments as a cost-effective alternative to monoclonal antibodies. We investigate the assay performance of MICB and demonstrate its capability for accurate immune checkpoint detection in simulated patient serum samples at clinically-relevant levels. MICB provides a dynamic range of 5 to 200 pg mL-1 for PD-1 and PD-L1, and 50 to 1000 pg mL-1 for LAG-3 with a coefficient of variation <13.8%. Sensitive immune checkpoint detection was achieved with limits of detection values of 5 pg mL-1 for PD-1, 5 pg mL-1 for PD-L1, and 50 pg mL-1 for LAG-3. The multiplexing capability, sensitivity, and relative assay simplicity of MICB make it capable of serving as a bioanalytical tool for immune checkpoint therapy monitoring.


Assuntos
Antígenos CD/sangue , Antígeno B7-H1/sangue , Técnicas Biossensoriais/métodos , Receptor de Morte Celular Programada 1/sangue , Antígenos CD/imunologia , Armoracia/enzimologia , Antígeno B7-H1/imunologia , Benzidinas/química , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/imunologia , Colorimetria/métodos , Técnicas Eletroquímicas/métodos , Peroxidase do Rábano Silvestre/química , Humanos , Hidrodinâmica , Peróxido de Hidrogênio/química , Imunoensaio/métodos , Dispositivos Lab-On-A-Chip , Receptor de Morte Celular Programada 1/imunologia , Anticorpos de Cadeia Única/imunologia , Proteína do Gene 3 de Ativação de Linfócitos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA