Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Heart Valve Dis ; 21(1): 1-4, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22474734

RESUMO

Valve disease is common and is increasing in prevalence as the population ages. The delivery of appropriate management is not always straightforward, and better ways of organizing care are required. Here, the argument is made for a specialist multidisciplinary valve clinic, while a description is provided of the authors' model clinic, which incorporates a specialist cardiologist in addition to sonographers and a nurse who carry out the surveillance services. The clinic is based at a cardiothoracic center and one district hospital, but could be generalized. Previous audits have shown that this model can reduce the number of patients seen by a cardiologist, thus improving the safety and quality of treatment compared to conventional clinics.


Assuntos
Doenças das Valvas Cardíacas , Modelos Organizacionais , Ambulatório Hospitalar/organização & administração , Equipe de Assistência ao Paciente/organização & administração , Especialização/normas , Competência Clínica/normas , Atenção à Saúde/métodos , Gerenciamento Clínico , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/terapia , Humanos , Padrões de Prática Médica/normas , Prevalência , Índice de Gravidade de Doença
3.
J Thorac Cardiovasc Surg ; 136(5): 1142-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19026794

RESUMO

OBJECTIVE: A stented bovine pericardial valve might be less obstructive than a stented porcine valve. This study compared early hemodynamic function in a prospective series of 99 patients randomized to receive either a Mosaic or Perimount replacement aortic valve. METHODS: Echocardiography was performed early after surgery and at 1 year after surgery. Patients also filled in psychologic questionnaires and underwent a 6-minute walk. RESULTS: The groups were matched demographically. The Perimount valve was significantly less obstructive in terms of mean pressure difference (11 +/- 5 vs 17 +/- 7 mm Hg; P < .0001), with a trend in favor of a larger effective orifice area (1.47 +/- 0.45 vs 1.28 +/- 0.46 cm(2); P = .05) postoperatively. There were no differences in left ventricular mass regression, aortic regurgitation, 6-minute walk, psychologic questionnaires, or mortality and clinical events. CONCLUSION: The stented bovine pericardial valve was less obstructive than the stented porcine valve. Both valves were associated with similar and significant improvements in quality of life, exercise ability, and regression of left ventricular mass.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Stents , Idoso , Idoso de 80 Anos ou mais , Animais , Insuficiência da Valva Aórtica/cirurgia , Bovinos , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio , Estudos Prospectivos , Inquéritos e Questionários , Suínos
4.
J Thorac Cardiovasc Surg ; 133(4): 1045-50, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17382651

RESUMO

OBJECTIVE: A composite stentless valve might be less obstructive than a preparation incorporating the porcine right coronary muscle bar. The aim of this study was to compare early hemodynamic function in a prospective series of 78 patients randomized to receive either a Toronto or Cryolife O'Brien stentless valve. METHODS: Echocardiography was performed early after surgery, between 3 and 6 months, and at 1 year after surgery. RESULTS: The groups were matched demographically. The Cryolife O'Brien valve was significantly less obstructive in terms of effective orifice area (1.81 vs 1.30 cm2; P < .0001), mean pressure difference (7.1 vs 11.7 mm Hg; P < .0001), and peak velocity (1.7 vs 2.2 m/s) assessed at 1 year (P = .001). Bypass time was 91 (SD 22) minutes for the Cryolife O'Brien compared with 125 (SD 22) minutes (P < .0001) for the Toronto. There was a higher incidence of paraprosthetic regurgitation in the Cryolife O'Brien valve (16.7% vs 3.2%). Mortality and clinical events were similar. CONCLUSION: The composite valve was less obstructive than the porcine valve, suggesting that stentless valves cannot be considered as a homogeneous class.


Assuntos
Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Feminino , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
J Thorac Cardiovasc Surg ; 131(4): 878-2, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16580447

RESUMO

BACKGROUND: A stentless valve is expected to be hemodynamically superior to a stented valve. The aim of this study was to compare early postoperative hemodynamic function and clinical events in a randomized, prospective series of 160 stentless and stented biological replacement aortic valves. METHODS: We randomized 160 consecutive patients on 1 surgeon's list to receive either a Toronto stentless porcine valve (St Jude Medical, Inc, St Paul, Minn) or a Perimount stented bovine pericardial valve (Edwards Lifesciences, Irvine, Calif). Echocardiography was performed at discharge, between 3 and 6 months, and at 1 year after surgery. Statistical analysis was performed by both intention to treat and actual valves implanted. RESULTS: The mean labeled size of both designs of valve was 24.7. There were no statistically significant differences in results at any time interval or whether analysis was performed by actual valves implanted or intention to treat. At 3 to 6 months for the Toronto versus the Perimount valve, the effective orifice area was 1.58 versus 1.66 cm2, the mean pressure difference was 7.54 versus 7.42 mm Hg, and the peak velocity was 2.07 versus 2.0.1 m/s. There was no difference in mortality, regression of left ventricular hypertrophy, or complications other than paraprosthetic regurgitation at 12 months or on follow-up for a proportion of the sample to 8 years. The incidence of regurgitation through the valves was similar for Toronto (10%) and Perimount (13.8%) at 1 year, but mild paraprosthetic regurgitation was found in 5 patients with the Perimount valve and none with Toronto valves. CONCLUSIONS: There were no significant differences in hemodynamic function or clinical events between the stented and stentless biological valves chosen for comparison in the early postoperative period or in preliminary follow-up to 5 years.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Stents , Técnicas de Sutura , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA