Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 281(5): 2353-2363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133806

RESUMO

PURPOSE: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis. METHODS: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE). RESULTS: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA4 ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA4 thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA4 ABG of ≤ 20 dB. None of the children reported a BC PTA4 deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days. CONCLUSION: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults. TRIAL REGISTRATION NUMBER: NCT05565339, 09 September 2022, retrospectively registered.


Assuntos
Prótese Ossicular , Adulto , Criança , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Implantação de Prótese , Condução Óssea , Audiometria de Tons Puros
2.
Artigo em Inglês | MEDLINE | ID: mdl-39001922

RESUMO

PURPOSE: This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP). METHODS: Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. RESULTS: 103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA4 ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA4 ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA4 ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA4 (post-operative minus pre-operative BC PTA4) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA4 deterioration of 11.3 dB HL. CONCLUSION: The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.

3.
Ear Hear ; 44(1): 146-154, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35925830

RESUMO

BACKGROUND: Stimulation with triphasic pulses has been shown to reduce the occurrence of unwanted facial nerve stimulation (FNS) with cochlear implants (CIs). However, there is little data available on how different pulse shapes affect the hearing outcome with electrical hearing in general. The aim of the study was to evaluate the effects of different stimulation pulse shapes on speech perception in noise, as well as loudness perception and subjective sound quality. METHODS: Twenty experienced cochlear-implant users not suffering from FNS participated in a prospective single-visit study. Based on the subjects' current clinical fitting, six fitting maps with different pulse shapes (biphasic and triphasic) and different interphase gap (IPG) durations (2.1 µs, 10 µs, and 20 µs) were created. First, the loudness was balanced for each configuration by adjusting the stimulation charge amount. Then, speech perception in noise was measured with a German matrix sentence test (Oldenburg Sentence test). The perception of particular sound attributes of speech and music, as well as overall preference, was evaluated with visual analog scales. RESULTS: Similar levels of speech perception were obtained with triphasic stimulation ( P = 0.891) and longer IPGs ( P = 0.361) compared to the subjects' clinical map settings. The stimulation amplitudes for equal loudness were significantly higher with triphasic stimulation compared to biphasic stimulation when keeping the IPG constant. Increasing the IPG had a significantly larger effect on perceived loudness ( P < 0.0001) and charge reduction for equal loudness with triphasic pulses compared to biphasic pulses. Triphasic configuration showed lower overall subjective sound quality ratings than biphasic for speech intelligibility, clarity, naturalness, and overall preference, as well as for music naturalness, and overall preference in the acute setting without adaptation time. Post-hoc pairwise comparisons against the clinical map revealed significantly lower speech naturalness ratings for triphasic with 2.1 µs IPG and for triphasic with 20 µs IPG only. CONCLUSION: Although some sound quality attributes were rated lower compared to the clinical map in the acute test setting, stimulation with triphasic pulses does not affect speech perception in noise and can be considered as a valuable option in CI fitting.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Estudos Prospectivos , Estimulação Elétrica , Audição
4.
Eur Arch Otorhinolaryngol ; 280(9): 3997-4007, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36856808

RESUMO

PURPOSE: Extreme weather events are rising due to the accelerating pace of climate change. These events impact human health and increase emergency room visits (EV) for many morbidities. Tinnitus is a common cause of EVs within otolaryngology in Germany and Austria. The effect of extreme weather conditions on tinnitus-related EVs is unknown. METHODS: A total of 526 tinnitus-related EVs at a tertiary care hospital in Vienna were identified. A distributed lag non-linear model with a maximum lag period of 14 days was fitted to investigate the immediate and delayed effect of single-day and prolonged (three-day) extreme atmospheric pressure, relative humidity, mean temperature, precipitation and mean wind speed on EV rates. Extreme conditions were defined as the 1st, 5th, 95th, and 99th percentile of the meteorological variables. Relative risk (RR) is defined as risk for tinnitus-related EVs at an extreme condition compared to the risk at the median weather condition. Cumulative RR (cRR) is the total cumulated EV risk for a given time period. RESULTS: High relative humidity increased same-day RR for tinnitus-related EVs to 1.75. Both low and high atmospheric pressure raised cRR as early as three days after an event to a maximum of 3.24. Low temperatures mitigated cRR within 4 days, while high temperatures tended to increase risk. Prolonged precipitation reduced cRR within one day. CONCLUSION: Extreme meteorological conditions are associated with tinnitus-related EV rates. Further investigation into potential causative links and underlying pathophysiological mechanisms is warranted.


Assuntos
Zumbido , Humanos , Zumbido/epidemiologia , Tempo (Meteorologia) , Temperatura Baixa , Temperatura , Serviço Hospitalar de Emergência
5.
Ear Hear ; 42(3): 709-717, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33369941

RESUMO

OBJECTIVES: Temporal fine structure information such as low-frequency sounds including the fundamental frequency (F0) is important to separate different talkers in noisy environments. Speech perception in noise is negatively affected by reduced temporal fine structure resolution in cochlear hearing loss. It has been shown that normal-hearing (NH) people as well as cochlear implant patients with preserved acoustic low-frequency hearing benefit from different F0 between concurrent talkers. Though patients with an active middle ear implant (AMEI) report better sound quality compared with hearing aids, they often struggle when listening in noise. The primary objective was to evaluate whether or not patients with a Vibrant Soundbridge AMEI were able to benefit from F0 differences in a concurrent talker situation and if the effect was comparable to NH individuals. DESIGN: A total of 13 AMEI listeners and 13 NH individuals were included. A modified variant of the Oldenburg sentence test was used to emulate a concurrent talker scenario. One sentence from the test corpus served as the masker and the remaining sentences as target speech. The F0 of the masker sentence was shifted upward by 4, 8, and 12 semitones. The target and masker sentences were presented simultaneously to the study subjects and the speech reception threshold was assessed by adaptively varying the masker level. To evaluate any impact of the occlusion effect on speech perception, AMEI listeners were tested in two configurations: with a plugged ear-canal contralateral to the implant side, indicated as AMEIcontra, or with both ears plugged, indicated as AMEIboth. RESULTS: In both study groups, speech perception improved when the F0 difference between target and masker increased. This was significant when the difference was at least 8 semitones; the F0-based release from masking was 3.0 dB in AMEIcontra (p = 0.009) and 2.9 dB in AMEIboth (p = 0.015), compared with 5.6 dB in NH listeners (p < 0.001). A difference of 12 semitones revealed a F0-based release from masking of 3.5 dB in the AMEIcontra (p = 0.002) and 3.4 dB in the AMEIboth (p = 0.003) condition, compared with 5.0 dB in NH individuals (p < 0.001). CONCLUSIONS: Though AMEI users deal with problems resulting from cochlear damage, hearing amplification with the implant enables a masking release based on F0 differences when F0 between a target and masker sentence was at least 8 semitones. Additional occlusion of the ear canal on the implant side did not affect speech performance. The current results complement the knowledge about the benefit of F0 within the acoustic low-frequency hearing.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Orelha Média , Humanos , Mascaramento Perceptivo , Fala
6.
J Med Internet Res ; 23(6): e28328, 2021 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-34185016

RESUMO

BACKGROUND: The data retrieved with the online search engine, Google Trends, can summarize internet inquiries into specified search terms. This engine may be used for analyzing inquiry peaks for different medical conditions and symptoms. OBJECTIVE: The aim of this study was to analyze World Wide Web interest peaks for "ear pain," "ear infection," and "ear drops." METHODS: We used Google Trends to assess the public online interest for search terms "ear pain," "ear infection," and "ear drops" in 5 English and non-English-speaking countries from both hemispheres based on time series data. We performed our analysis for the time frame between January 1, 2004, and December 31, 2019. First, we assessed whether our search terms were most relevant to the topics of ear pain, ear infection, and ear drops. We then tested the reliability of Google Trends time series data using the intraclass correlation coefficient. In a second step, we computed univariate time series plots to depict peaks in web-based interest. In the last step, we used the cosinor analysis to test the statistical significance of seasonal interest peaks. RESULTS: In the first part of the study, it was revealed that "ear infection," "ear pain," and "ear drops" were the most relevant search terms in the noted time frame. Next, the intraclass correlation analysis showed a moderate to excellent reliability for all 5 countries' 3 primary search terms. The subsequent analysis revealed winter interest peaks for "ear infection" and "ear pain". On the other hand, the World Wide Web search for "ear drops" peaked annually during the summer months. All peaks were statistically significant as revealed by the cosinor model (all P values <.001). CONCLUSIONS: It can be concluded that individuals affected by otitis media or externa, possibly the majority, look for medical information online. Therefore, there is a need for accurate and easily accessible information on these conditions in the World Wide Web, particularly on differentiating signs and therapy options. Meeting this need may facilitate timely diagnosis, proper therapy, and eventual circumvention of potentially life-threatening complications.


Assuntos
Dor , Ferramenta de Busca , Humanos , Internet , Reprodutibilidade dos Testes , Estações do Ano
7.
Eur Arch Otorhinolaryngol ; 278(5): 1653-1660, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32968893

RESUMO

OBJECTIVE: To assess whether web-based public inquiries into pharyngitis-related search terms follow annual incidence peaks of acute pharyngitis in various countries from both hemispheres. METHODS: Google Trends (GT) was utilized for systematic acquisition of pharyngitis-related search terms (sore throat, cough, fever, cold). Six countries from both hemispheres including four English (United Kingdom, United States, Canada, and Australia) and two non-English speaking countries (Austria and Germany) were selected for further analysis. Time series data on relative search interest for pharyngitis-related search terms, covering a timeframe between 2004 and 2019 were extracted. Following reliability analysis using the intra-class correlation coefficient, the cosinor time series analysis was utilized to determine annual peaks in public-inquiries. RESULTS: The extracted datasets of GT proved to be highly reliable with correlation coefficients ranging from 0.83 to 1.0. Graphical visualization showed annual seasonal peaks for pharyngitis-related search terms in all included countries. The cosinor time series analysis revealed these peaks to be statistically significant during winter months (all p < 0.001). CONCLUSION: Our study revealed seasonal variations for pharyngitis-related terms which corresponded to winter incidence peaks of acute pharyngitis. These results highlight the need for easily accessible information on diagnosis, therapy, and red-flag symptoms for this common disease. Accurately informed patients might contribute to a reduction of unnecessary clinic visits and potentially cutback the futile antibiotic overuse.


Assuntos
Faringite , Antibacterianos/uso terapêutico , Austrália/epidemiologia , Áustria , Canadá/epidemiologia , Alemanha , Humanos , Incidência , Faringite/tratamento farmacológico , Faringite/epidemiologia , Reprodutibilidade dos Testes , Reino Unido , Estados Unidos/epidemiologia
8.
Eur Arch Otorhinolaryngol ; 277(7): 1977-1985, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32180015

RESUMO

PURPOSE: Epistaxis represents the most frequent ear, nose, throat-related emergency symptom. Seasonal variation in epistaxis incidence, with peaks during winter months, is widely accepted, although the literature itself remains inconclusive. The objective of this study was to evaluate public inquiry into nose bleeding, by considering Google-based search query frequency on "Epistaxis"-related search terms and to assess possible seasonal variations globally. METHODS: Epistaxis-related search terms were systematically collected and compared using Google Trends (GT). Relative search volumes for the most relevant epistaxis-related terms, covering a timeframe from 2004 to 2019 were analysed using cosinor time series analysis for the United States of America, Germany, the United Kingdom, Italy, Canada, Australia, and New Zealand. RESULTS: Graphical representation revealed seasonal variations with peaks during winter months in the majority of countries included. Subsequent cosinor analysis revealed these variations to be significant (all p < 0.001). CONCLUSION: Public interest in seeking epistaxis-related information through the Internet displayed seasonal patterns in countries from both hemispheres, with the highest interest during winter months. Further studies exploring causality with environmental factors are warranted.


Assuntos
Epistaxe , Internet , Austrália/epidemiologia , Canadá , Epistaxe/epidemiologia , Epistaxe/etiologia , Alemanha , Humanos , Itália , Ferramenta de Busca , Estações do Ano , Reino Unido , Estados Unidos/epidemiologia
10.
Ear Hear ; 35(6): e272-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25127325

RESUMO

OBJECTIVES: The aim of the present study was to compare two novel fine structure strategies "FS4" and "FS4-p" with the established fine structure processing (FSP) strategy. FS4 provides fine structure information on the apical four-electrode channels. With FS4-p, these electrodes may be stimulated in a parallel manner. The authors evaluated speech perception, sound quality, and subjective preference. DESIGN: A longitudinal crossover study was done on postlingually deafened adults (N = 33) who were using FSP as their default strategy. Each participant was fitted with FS4, FS4-p, and FSP, for 4 months in a randomized and blinded order. After each run, an Adaptive Sentence test in noise (Oldenburger Sentence Test [OLSA]) and a Monosyllable test in quiet (Freiburger Monosyllables) were performed, and subjective sound quality was determined with a Visual Analogue Scale. At the end of the study the preferred strategy was noted. RESULTS: Scores of the OLSA did not reveal any significant differences among the three strategies, but the Freiburger test showed a statistically significant effect (p = 0.03) with slightly worse scores for FS4 (49.7%) compared with FSP (54.3%). Performance of FS4-p (51.8%) was comparable with the other strategies. Both audiometric tests depicted a high variability among subjects. The number of best-performing strategies for each participant individually was as follows: (a) for the OLSA: FSP, N = 10.5; FS4, N = 10.5; and FS4-p, N = 12; and (b) for the Freiburger test: FSP, N = 14; FS4, N = 9; and FS4-p, N = 10. A moderate agreement was found in the best-performing strategies of the Speech tests within the participants. For sound quality, speech in quiet, classical, and pop music were assessed. No significant effects of strategy were found for speech in quiet and classical music, but auditory impression of pop music was rated as more natural in FSP compared with FS4 (p = 0.04). It is interesting that at the end of the study, a majority of the participants favored the new coding strategies over their previous default FSP (FSP, N = 13; FS4, N = 13; FS4-p, N = 7). CONCLUSIONS: In summary, FS4 and FS4-p offer new and further options in audio processor fitting, with similar levels of speech understanding in noise as FSP. This is an interesting result, given that the strategies' presentation of temporal fine structure differs from FSP. At the end of the study, 20 of 33 subjects chose either FS4 or FS4-p over their previous default strategy FSP.


Assuntos
Implantes Cocleares , Surdez/reabilitação , Processamento de Sinais Assistido por Computador , Percepção da Fala , Adulto , Idoso , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Teste do Limiar de Recepção da Fala , Adulto Jovem
11.
Otolaryngol Head Neck Surg ; 170(3): 795-803, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37943865

RESUMO

OBJECTIVE: Extreme weather events are becoming more prevalent with the increasing pace of climate change. These events negatively impact human health and put considerable strain on health care resources, including emergency departments. Within otolaryngology, acute pharyngitis is a common reason for emergency room visits (ERV). Therefore, we aimed to investigate the impact of extreme meteorological conditions on ERV rates related to acute pharyngitis. STUDY DESIGN: Retrospective time-series study. SETTING: ERVs related to acute pharyngitis (n = 1511) were identified at a tertiary care hospital in Vienna, Austria, between 2015 and 2018. METHODS: The effects of single-day and prolonged (3-day) extreme weather events on ERVs were analyzed using a distributed lag nonlinear model. Relative risk (RR) and cumulative relative risk (cRR) were calculated over a lag period of 14 days. RR refers to the risk for pharyngitis-related ERV at extreme conditions (1st, 5th, 95th, or 99th percentile) compared to the risk at median conditions. RESULTS: Same-day RR (lag0) was elevated more than 3-fold after prolonged extremely low mean temperatures (P = .028). Furthermore, same-day RR after single-day and prolonged extremely high relative humidity was elevated by 51% (P = .024) and 46% (P = .036), respectively. Significant delayed effects on cRR were observed for extreme mean temperatures, relative humidity, and mean wind speeds within 8 days and for extreme atmospheric pressure within 14 days. CONCLUSION: Extreme weather events impact ERV rates for acute pharyngitis. Extremely low temperatures, high relative humidity, high atmospheric pressure, and low and high wind speeds were risk-promoting factors.


Assuntos
Clima Extremo , Faringite , Humanos , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Fatores de Risco , Faringite/diagnóstico , Faringite/epidemiologia
12.
Otolaryngol Head Neck Surg ; 170(6): 1630-1647, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38529662

RESUMO

OBJECTIVE: The bone conduction implant (BCI) 602 is a new transcutaneous BCI with smaller dimensions. However, limited patient numbers restrict the statistical power and generalizability of the current studies. The present systematic review and meta-analysis summarize early audiological and medical outcomes of adult and pediatric patients implanted with the BCI 602 due to mixed or conductive hearing loss. DATA SOURCE: Following the Preferred Reporting items for Systematic Reviews and Meta-analyses guidelines, 108 studies were reviewed, and 6 (5.6%) were included in the meta-analysis. REVIEW METHOD: The data on study and patient characteristics, surgical outcomes, and audiological test results were extracted from each article. Meta-analysis employed the fixed-effect and random-effects models to analyze the mean differences (MDs) between pre- and postoperative performances. RESULTS: In total, 116 patients were evaluated, including 64 (55%) adult and 52 (45%) pediatric patients. No intraoperative adverse events were reported, while postoperative complications were reported in 2 (3.1%) adult and 2 (3.8%) pediatric patients. Studies consistently showed significant improvements in audiological outcomes, quality of life, and sound localization in the aided condition. In the meta-analysis, we observed a significant difference in the unaided compared to the aided condition in sound field thresholds (n = 112; MD, -27.05 dB; P < 0.01), signal-to-noise ratio (n = 96; MD, -6.35 dB; P < 0.01), and word recognition scores (n = 96; MD, 68.89%; P < 0.01). CONCLUSION: The implantation of the BCI 602 was associated with minimal surgical complications and excellent audiological outcomes for both the pediatric and the adult cohort. Therefore, our analysis indicates a high level of safety and reliability. Further research should focus on direct comparisons with other BCIs and long-term functional outcomes.


Assuntos
Condução Óssea , Humanos , Perda Auditiva Condutiva/cirurgia , Auxiliares de Audição , Resultado do Tratamento , Criança , Desenho de Prótese
13.
Laryngoscope Investig Otolaryngol ; 9(5): e70010, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39346784

RESUMO

Objective: To analyze medical device reports (MDR) submitted to the Food and Drug Administration's (FDA) Manufacturer and User Device Facility Experience (MAUDE) database to identify adverse events (AEs) in patients implanted with novel active bone conduction hearing implants (BCIs). Methods: We conducted a search of the FDA MAUDE database on the newest generation of BCIs. Data were collected concerning device malfunctions, patient injuries, factors triggering these incidents, and the subsequent actions taken. Results: In total, 93 (16.7%) device malfunctions and 465 (83.3%) patient injuries with 358 subsequent interventions were identified, resulting in 558 AEs. Although the absolute AE number per device cannot be identified, the following trends were detected: Among the 494 AEs associated with OSI200, 55 (11.1%) reported device malfunctions and 454 (88.9%) cited patient injuries. Out of the 64 AEs linked to BCI602, 28 (59.4%) were associated with malfunctions, whereas 26 (40.6%) involved patient injuries. The most frequently reported particular AEs for the OSI200 were infection (n = 171, 34.6%), extrusion of the device (n = 107, 21.7%), and pain (n = 51, 10.3%). Conversely, no device output (n = 20, 31.3%) and loss of osseointegration (n = 7, 10.9%) were the most reported AEs for the BCI602. Various AEs led to 214 explanations and 77 revision surgeries. Sixty-seven AEs reported conservative treatment. Conclusion: The current study provides an overview of the most commonly reported complications with new active BCIs. Although providing an overview, given the limitations of the FDA MAUDE database, our results have to be interpreted with caution. Level of Evidence: 4.

14.
Eur J Radiol ; 180: 111706, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39197269

RESUMO

BACKGROUND: Thoracic computed tomography scans (CT) are used by several study groups to investigate the circulatory structures (heart and vessels) located behind the pressure point for chest compressions. Yet, it remains unclear how the positioning of these structures is influenced by factors such as intubation, the respiratory cycle and arm positioning. METHODS: We retrospectively analyzed data of adult patients with in- or out-of-hospital cardiac arrest who underwent thoracic CT imaging within one year before or up to six months after arrest. A region of interest (ROI) behind the pressure point was defined. The largest structure within this region was defined as "leading circulatory structure", which was the primary outcome. Airway status (intubated versus spontaneous breathing), respiratory cycle (inspiration, expiration, resting expiratory position), and arm position (up over the head versus down beside the trunk) served as covariates in an ordinal regression model. RESULTS: Among 500 initially screened patients, 411 (82.2 %) were included in the analysis. There was a significant association between the arm position and the leading circulatory structure behind the pressure point. However, no association was found with airway status or respiratory cycle. The most frequently identified leading circulatory structure was the left atrium (arms up: 41.8 %, down: 50.7 %), followed by the ascending aorta (up: 23.8 % vs. down: 16.7 %). The left ventricle was the leading structure in only one case (0.2 %, arms down). CONCLUSION: This study shows that arm position is significantly associated with the leading circulatory structure behind the pressure point for chest compressions in cardiac arrest.


Assuntos
Reanimação Cardiopulmonar , Posicionamento do Paciente , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Reanimação Cardiopulmonar/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Posicionamento do Paciente/métodos , Tomografia Computadorizada por Raios X/métodos , Parada Cardíaca/terapia , Parada Cardíaca/diagnóstico por imagem , Parada Cardíaca/fisiopatologia , Braço/diagnóstico por imagem , Braço/irrigação sanguínea , Pressão , Adulto , Radiografia Torácica/métodos
15.
Otol Neurotol ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39284021

RESUMO

OBJECTIVE: To evaluate the long-term hearing outcome after translabyrinthine resection of tumors within the internal auditory canal (IAC) with simultaneous cochlear implantation (CI). STUDY DESIGN: Prospective study. SETTING: Tertiary referral center. PATIENTS: Thirty-seven patients with tumors of the IAC undergoing translabyrinthine tumor surgery as a first-line therapy. INTERVENTIONS: Intraoperatively, electrically evoked auditory brainstem response audiometry (eABR) was performed in all patients to assess cochlear nerve (CN) integrity. In case of preserved CN function after tumor removal, CI was subsequently performed. Postoperatively, patients were regularly followed up to evaluate pure-tone hearing as well as speech recognition with a monosyllabic word comprehension test. MAIN OUTCOME MEASURES: Postoperative hearing thresholds and word recognition scores. RESULTS: Of 37 included patients, 22 (59.46%) had positive eABR responses after tumor removal. Twenty-one of these underwent simultaneous CI directly after tumor surgery and were followed-up for 24.24 ± 19.83 months after surgery. Hearing of these patients significantly improved from 73.87 ± 21.40 dB preoperatively to a mean pure-tone average of 41.56 ± 18.87 dB 1 year (p = 0.0008) and 34.58 ± 2.92 dB 3 years after surgery (p = 0.0157). Speech recognition significantly recovered from 13.33 ± 25.41% to 58.93 ± 27.61% 1 year (p = 0.0012) and 51.67 ± 28.58% 3 years postoperatively (p = 0.0164). CONCLUSIONS: Regardless of tumor histopathology, CI is an effective option to restore patients' hearing after translabyrinthine tumor surgery. After CI, patients hearing can be restored over a long-term period of a minimum of 3 years post-surgery. Furthermore, eABR proves to be a practical tool to evaluate CN function and screen for patients eligible for CI.

16.
Front Public Health ; 11: 1153111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37325328

RESUMO

Background: Climate change has been associated with a higher frequency of extreme weather events, resulting in an overall increase in morbidity and mortality. Acute otitis media (AOM) is one of the most common otolaryngological infections and accounts for 1.5% of emergency department visits. This study aimed to identify associations between extreme weather events and the immediate and delayed risks for AOM-related emergency department visits (EV). Methods: A total of 1,465 AOM-related EVs were identified in the Vienna General Hospital between 2015 and 2018. A distributed lag non-linear model was applied to evaluate the relationship between extreme weather conditions and the total number of AOM-related EVs per day. The relative risk (RR) and cumulative RR (cRR) of single-day events and extended weather events over three days were analyzed over a lag period of 14 days. Results: AOM-related EVs showed a pronounced seasonality, with the highest occurrence during winter. Single-day weather events affected AOM-related EVs only at high relative humidity. Prolonged extreme weather conditions over three days, however, significantly increased the cRR for AOM-related EVs to 3.15 [1.26-7.88; p = 0.014] and 2.14 [1.14-4.04; p = 0.018] at mean temperatures of -4°C (1st-percentile - p1) and 0°C (p5) on the same day. Relative humidity of 37% (p1) decreased RR to 0.94 [0.88-0.99; p = 0.032] on day 7, while extremely high humidity of 89% (p99) led to an increased cRR of 1.43 [1.03-2.00; p = 0.034] on day 7. Heavy prolonged precipitation of 24mm (p95) reduced cRR beginning day 4 up until day 14 to 0.52 [0.31-0.86; p = 0.012]. Prolonged low atmospheric pressure events of 985hPa (p5) reduced the RR to 0.95 [0.91-1.00; p = 0.03], whereas extremely high atmospheric pressure events of 1013hPa (p99) increased the RR to 1.11 [1.03-1.20; p = 0.008]. Extremely low wind speeds significantly diminished the RR of AOM-related EVs. Conclusions: While single-day extreme weather events had little impact on the occurrence of AOM-related EVs, extended periods of extreme temperatures, relative humidity, precipitation, wind speeds and atmospheric pressure significantly impacted the RR for AOM-related EVs. These findings could help improve healthcare resource allocation in similar climates and aid in educating patients about the role of environmental factors in AOM.


Assuntos
Otite Média , Tempo (Meteorologia) , Humanos , Temperatura , Estações do Ano , Otite Média/epidemiologia , Serviço Hospitalar de Emergência
17.
Otolaryngol Head Neck Surg ; 169(3): 615-621, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36939484

RESUMO

OBJECTIVE: Recently, the Bonebridge 602 implant was introduced. Its smaller dimensions facilitate implantation even in surgically demanding cases. However, in extreme anatomical conditions, implant lifts are still required. We intended to report on the medical and audiological outcomes of all patients implanted with the implant with a secondary focus on the safety, efficacy, and feasibility of the use of 1-mm lifts. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary academic center. METHODS: We retrospectively analyzed all patients implanted with the Bonebridge 602. Patient demographics and surgically-specific data were collected from the medical charts. Furthermore, audiological results were assessed. Outcomes were compared between implantations with versus without lifts. RESULTS: Twenty-one devices were implanted during the study period. Satisfactory audiological results were observed, while no intra- or postoperative adverse events occurred. The majority of patients were daily users at the end of the observation period (n = 20/21, 95.2%), and one patient (n = 1/21, 4.8%) was a nonuser after 6 months of use because of subjective dissatisfaction. Due to anatomical considerations, 1-mm lifts were used in 4 implantations (19.0%). The application of lifts did not result in prolonged surgical times, complications, or shorter time of use, nor did it negatively affect audiometric results. CONCLUSION: Implantations with the new and smaller Bonebridge were associated with gratifying medical and audiological outcomes. Still, in extreme anatomical conditions, 1-mm lifts are necessary. Nonetheless, surgical placement with the help of lifts seems safe, effective, and feasible, and is a viable option in cases with challenging anatomies due to previous surgeries or anomalies.


Assuntos
Auxiliares de Audição , Próteses e Implantes , Humanos , Estudos Retrospectivos , Próteses e Implantes/efeitos adversos , Condução Óssea , Implantação de Prótese/métodos , Audiometria , Auxiliares de Audição/efeitos adversos , Perda Auditiva Condutiva/cirurgia , Resultado do Tratamento
18.
Otolaryngol Head Neck Surg ; 168(6): 1502-1510, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36856581

RESUMO

OBJECTIVE: Electrically evoked auditory brainstem response audiometry has emerged as a suitable option to intraoperatively assess cochlear nerve function during vestibular schwannoma resection. This study aimed to analyze the functional outcome and implant usage of patients with preserved auditory nerve responses after simultaneous translabyrinthine schwannoma resection and cochlear implantation. STUDY DESIGN: Prospective study. SETTING: Tertiary referral center. METHODS: Patients with unilateral sporadic vestibular schwannoma underwent translabyrinthine tumor resection. Intraoperatively, electrically evoked auditory brainstem response audiometry was performed before and after tumor removal. Cochlear implantation was carried out if positive responses were detected after tumor removal indicating cochlear nerve function. Postoperatively, patients were biannually followed-up to assess aided sound field audiometry and word recognition as well as implant usage. RESULTS: Overall, 26 patients with vestibular schwannoma underwent translabyrinthine schwannoma resection. Out of these patients, 15 had positive cochlear nerve responses after tumor removal and concurrently received a cochlear implant. In 13 patients with histologically confirmed vestibular schwannoma, hearing improved by 23.7 ± 33.2 decibels and word recognition by 25.0 ± 42.4% over a mean follow-up period of 18 months. Overall, 12 included patients were regular cochlear implant users. CONCLUSION: Patients with vestibular schwannoma can benefit substantially from cochlear implantation. Intraoperative assessment of cochlear nerve function using electrically evoked auditory brainstem response audiometry can help to better identify individuals eligible for simultaneous vestibular schwannoma resection and cochlear implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Neuroma Acústico , Humanos , Neuroma Acústico/cirurgia , Estudos Prospectivos , Cóclea/patologia , Nervo Coclear/patologia , Nervo Coclear/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
19.
J Voice ; 36(1): 98-105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32439216

RESUMO

OBJECTIVES: Acute laryngitis is a common disease with self-limiting nature. Since the leading cause is attributed to viral infections and thus self-limiting, many affected individuals do not seek professional medical help. However, because the major symptom of hoarseness imposes a substantial burden in everyday life, it might be speculated that web-based search interest on this condition follows incidence rates, with highest peaks during winter months. The aim of this study was to evaluate global public health-information seeking behaviour on laryngitis-related search terms. METHODS: We utilized Google Trends to assess country-specific, representative laryngitis-related search terms for English and non-English speaking countries of both hemispheres. Extracted time series data from Australia, Brazil, Canada, Germany, the United Kingdom, and the United States of America, covering a timeframe between 2004 and 2019 were first assessed for reliability, followed by seasonality analysis using the cosinor model. RESULTS: Direct comparisons revealed different, representative laryngitis-related search terms for English- and non-English speaking countries. Extracted data showed a trend of higher reliability in countries with more inhabitants. Subsequent graphical analysis revealed winter peaks in all countries from both hemispheres. Cosinor analysis confirmed these seasonal variations to be significant (all P < 0.001). CONCLUSION: Public interest in laryngitis-related, online health information displayed seasonal variations in countries from both hemispheres, with highest interest during winter months. These findings emphasize the importance to optimize the distribution of reliable, web-based health education in order to prevent the spread of misinformation and to improve health literacy among general populations.


Assuntos
Laringite , Alemanha , Humanos , Infodemiologia , Internet , Laringite/diagnóstico , Laringite/epidemiologia , Reprodutibilidade dos Testes , Estações do Ano , Estados Unidos
20.
J Pers Med ; 12(2)2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35207679

RESUMO

Less than 20% of patients with sensorineural hearing loss (HL) provided with the Vibrant Soundbridge (VSB) experience a progressive HL and warrant cochlear implantation (CI). The aim of this study was to identify possible predictors of progressive HL prior to VSB implantation. This retrospective study included all consecutive ears with sensorineural HL provided with the VSB between 1998 and 2016. The patient cohort was divided in a study group comprising patients who underwent CI (CI group) after years of VSB usage and those who did not require VSB replacement during the observational time (control group). Pre- and postoperative pure-tone audiometry thresholds were compared among the two groups. Fifteen out of 81 VSB devices (18.5%) required a CI. The CI group had higher preoperative air-conduction (AC) thresholds than the control group (64.3 ± 8.9 dB vs. 56.3 ± 12.9 dB; p = 0.007) at the time of the VSB implantation. On average, the CI group was significantly younger (39.1 ± 12.3 years vs. 52.6 ± 16.2 years; p = 0.003). In conclusion, VSB users with higher preoperative AC thresholds and younger age at the time of VSB implantation might be at risk for progressive HL within the upcoming eight years and need a further CI surgery. Preoperative counseling is particularly advisable in this patient group.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA