Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Heart Lung Circ ; 32(2): 252-260, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36443175

RESUMO

BACKGROUND: Most modern cardiac implantable electronic device (CIED) systems are now compatible with magnetic resonance imaging (MRI) scans. The requirement for both pre- and post-MRI CIED checks imposes significant workload to the cardiac electrophysiology service. Here, we sought to determine the burden of CIED checks associated with MRI scans. METHODS: We identified all CIED checks performed peri-MRI scans at our institution over a 3-year period between 1 July 2017 to 30 June 2020, comprising three separate financial years (FY). Device check reports, MRI scan reports and clinical summaries were collated. The workload burden was determined by assessing the occasions and duration of service. Analysis was performed to determine cost burden/projections for this service and identify factors contributing to the workload. RESULTS: A total of 739 CIED checks were performed in the peri-MRI scan setting (370 pre- and 369 post-MRI scan), including 5% (n=39) that were performed outside of routine hours (weekday <8 am or >5 pm, and weekends). MRIs were performed for 295 patients (75±13 years old, 64% male) with a CIED (88% permanent pacemaker, and 12% high voltage device), including 49 who had more than one MRI scan. The proportion of total MRI scans for patients with a CIED in-situ increased each FY (from 0.5% of all MRIs in FY1, to 0.9% in FY2, to 1.0% in FY3). The weekly workload increased (R2=0.2, p<0.001), but with week-to-week variability due to ad hoc scheduling (209 days with only one MRI vs 78 days with ≥2 MRIs for CIED patients). The projected annual cost of this service will increase to AUD$161,695 in 10 years for an estimated annual 546 MRI scans for CIED patients. CONCLUSIONS: There is an increasing workload burden and expense associated with CIED checks in the peri-MRI setting. Appropriate budgeting, staff allocation and standardisation of automated CIED pre-programming features among manufacturers are urgently needed.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Imageamento por Ressonância Magnética/métodos
2.
Heart Lung Circ ; 32(2): 184-196, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36599791

RESUMO

IMPORTANCE: Randomised trials have shown that catheter ablation (CA) is superior to medical therapy for ventricular tachycardia (VT) largely in patients with ischaemic heart disease. Whether this translates to patients with all forms and stages of structural heart disease (SHD-e.g., non-ischaemic heart disease) is unclear. This trial will help clarify whether catheter ablation offers superior outcomes compared to medical therapy for VT in all patients with SHD. OBJECTIVE: To determine in patients with SHD and spontaneous or inducible VT, if catheter ablation is more efficacious than medical therapy in control of VT during follow-up. DESIGN: Randomised controlled trial including 162 patients, with an allocation ratio of 1:1, stratified by left ventricular ejection fraction (LVEF) and geographical region of site, with a median follow-up of 18-months and a minimum follow-up of 1 year. SETTING: Multicentre study performed in centres across Australia. PARTICIPANTS: Structural heart disease patients with sustained VT or inducible VT (n=162). INTERVENTION: Early treatment, within 30 days of randomisation, with catheter ablation (intervention) or initial treatment with antiarrhythmic drugs only (control). MAIN OUTCOMES, MEASURES, AND RESULTS: Primary endpoint will be a composite of recurrent VT, VT storm (≥3 VT episodes in 24 hrs or incessant VT), or death. Secondary outcomes will include each of the individual primary endpoints, VT burden (number of VT episodes in the 6 months preceding intervention compared to the 6 months after intervention), cardiovascular hospitalisation, mortality (including all-cause mortality, cardiac death, and non-cardiac death) and LVEF (assessed by transthoracic echocardiography from baseline to 6-, 12-, 24- and 36-months post intervention). CONCLUSIONS AND RELEVANCE: The Catheter Ablation versus Anti-arrhythmic Drugs for Ventricular Tachycardia (CAAD-VT) trial will help determine whether catheter ablation is superior to antiarrhythmic drug therapy alone, in patients with SHD-related VT. TRIAL REGISTRY: Australian New Zealand Clinical Trials Registry (ANZCTR) TRIAL REGISTRATION ID: ACTRN12620000045910 TRIAL REGISTRATION URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=377617&isReview=true.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Antiarrítmicos/uso terapêutico , Volume Sistólico , Estudos Prospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Austrália/epidemiologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Isquemia Miocárdica/cirurgia , Ablação por Cateter/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
3.
J Electrocardiol ; 73: 42-48, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35633601

RESUMO

BACKGROUND: Little data exists on electrogram sensing in current generation of miniaturized insertable cardiac monitors (ICMs). OBJECTIVE: To compare the sensing capability of ICM with different vector length: Medtronic Reveal LINQ (~40 mm) vs. Biotronik Biomonitor III (BM-III, ~70 mm). METHODS: De-identified remote monitoring transmissions from n = 40 patients with BM-III were compared with n = 80 gender and body mass index (BMI)-matched patients with Reveal LINQ. Digital measurement of P- and R-wave amplitude from calibrated ICM electrograms was undertaken by 3 investigators independently. Further, we evaluated the impact of BMI and gender on P-wave visibility. RESULTS: Patients in both groups were well matched for gender and BMI (53% male, mean BMI 26.7 kg/m2, both p = NS). Median P- and R-wave amplitude were 97% & 56% larger in the BM-III vs. LINQ [0.065 (IQR 0.039-0.10) vs. 0.033 (IQR 0.022-0.050) mV, p < .0001; & 0.78 (IQR 0.52-1.10) vs. 0.50 (IQR 0.41-0.89) mV, p = .012 respectively). The P/R-wave ratio was 36% greater with the BM-III (p < .001). The 25th percentile of P-wave amplitude for all 120 patients was .026 mV. Logistic regression analysis showed BM-III was more likely than LINQ to have P-wave amplitude ≥.026 mV (OR 7.47, 95%CI 1.965-29.42, p = .003), and increasing BMI was negatively associated with P-wave amplitude ≥.026 mV (OR 0.84, 95%CI 0.75-0.95, p = .004). However, gender was not significantly associated with P-wave amplitude ≥.026 mV (p = .37). CONCLUSION: The longer ICM sensing vector of BM-III yielded larger overall P- and R- wave amplitude than LINQ. Both longer sensing vector and lower BMI were independently associated with greater P-wave visibility.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Feminino , Humanos , Masculino
4.
Heart Lung Circ ; 31(8): 1119-1125, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35461785

RESUMO

BACKGROUND: Requests from the emergency department (ED) for cardiac implantable electronic device (CIED) checks constitute a large workload for cardiac electrophysiology services. We sought to determine the yield of, and clinical characteristics associated with, clinically relevant (remarkable) issues from ED CIED checks. METHODS: Consecutive CIED checks from our ED over a 12-month period were studied. A remarkable issue (RI) was defined as arrhythmia relating to the presentation or device/lead issue requiring reprogramming or intervention. The association between the presenting complaint and an RI was assessed using regression analysis. Multivariable regression model was used to identify pre-specified patient-level characteristics that were predictive of a RI. RESULTS: A RI was found in 28% (n=98) of 354 ED CIED checks for 306 patients (76±16 yrs, 59% male). Most patients had no RI (n=224, 73%). One third of checks occurred after-hours and these had a higher yield of RIs than those during routine clinic hours (35% vs 23%, p=0.018). Presenting with a perceived ICD shock was predictive of a RI (odds ratio [OR] 6.0, 95% CI=1.8-20.0). Syncope/presyncope was five-fold less likely to be predictive of a RI (OR 0.19, 95% CI=0.13-0.28) despite being the most common indication for CIED check (51%, n=180 checks). Only history of AF was predictive of RI while advancing age was predictive of not finding a RI. CONCLUSION: Almost three-quarters of ED CIED checks did not yield any RI. Patient-reported ICD shock and history of AF were predictive of RI, while syncope/presyncope was not. New models of care especially during after-hours, may help to reduce the burden on cardiac electrophysiology services and health care costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Atenção à Saúde , Eletrônica , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino
5.
Heart Lung Circ ; 30(8): 1174-1183, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33722491

RESUMO

BACKGROUND: The epidemiology of atrial fibrillation (AF) amongst Indigenous populations remains poorly characterised. We studied hospitalisations for AF in Central Australia, the most populous Indigenous region in the country. METHODS: Patients with a diagnosis of AF admitted to Alice Springs Hospital, the only secondary health care facility and provider of cardiac care in remote Central Australia, were identified from 2006 to 2016. Age and gender-specific hospitalised AF prevalence, comorbidities, and CHA2DS2-VASc scores were ascertained. RESULTS: Of 57,056 admitted patients over the study period, 1,210 (2.1%; 46% Indigenous) had a diagnosis of AF. For Indigenous and non-Indigenous individuals <45 years, hospitalised AF prevalence per 10,000 population was 105 (CI 84-131) and 50 (CI 36-68) in males (ratio=2.10), and 98 (CI 77-123) and 12 (CI 6-23) in females (ratio=7.92), respectively. For Indigenous and non-Indigenous individuals ≥65 years, hospitalised AF prevalence per 10,000 was 1,577 (CI 1,194-2,026) and 2,326 (CI 2,047-2,623) in males (ratio=0.68), and 1,713 (CI 1,395-2,069) and 1,897 (1,623-2,195) in females (ratio=0.90). Indigenous individuals had higher rates of cardiometabolic comorbidities, particularly at younger ages. CHA2DS2-VASc scores were greater in Indigenous individuals, particularly those <45 years (2.5±1.5 versus 0.7±1.1, p<0.001). CONCLUSIONS: The prevalence of hospitalised AF amongst Indigenous people in remote Central Australia was significantly higher than in non-Indigenous individuals, particularly in younger age groups and females. Indigenous individuals with hospitalised AF also had a markedly greater prevalence of cardiometabolic comorbidities and elevated stroke risk. These data suggest that AF may be contributing to the gap in morbidity and mortality experienced by Indigenous Australians.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Fibrilação Atrial/epidemiologia , Austrália/epidemiologia , Feminino , Humanos , Incidência , Masculino , Prevalência , Medição de Risco , Fatores de Risco
6.
Heart Lung Circ ; 30(5): 707-713, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33132053

RESUMO

OBJECTIVE: Prior studies have demonstrated that anticoagulation underutilisation for atrial fibrillation (AF) and elevated stroke risk is common. However, there is little data on factors associated with appropriate anticoagulation, particularly in Indigenous Australians who face a disproportionate burden of AF and stroke. We thus sought to determine factors associated with anticoagulation use in Australians with AF. DESIGN: Administrative, clinical, prescriptive and laboratory data were linked and aggregated over a 12-year period. SETTING: Single tertiary teaching hospital. PARTICIPANTS: 19,305 (98%) and 308 (2%) consecutive non-Indigenous and Indigenous Australians with AF identified from administrative databases. MAIN OUTCOME MEASURES: Associations of anticoagulation use according to ethnicity. RESULTS: Significant independent predictors of anticoagulation use included hypertension (odds ratio [OR] 1.25, 95% confidence interval [CI] 1.17-1.34; p<0.001), diabetes (OR 1.14, 95% CI 1.05-1.24; p=0.002), heart failure (OR 1.54 95% CI 1.43-1.66; p<0.001) and prior stroke or transient ischaemic attack (OR 2.07, 95% CI 1.84-2.33; p<0.001). In contrast, increasing age (OR 0.99, 95% CI 0.98-0.99; p<0.001), female gender (OR 0.88, 95% CI 0.82-0.93; p<0.001), and vascular disease (OR 0.72, 95% CI 0.64-0.80; p<0.001) were significant predictors of no anticoagulation. Hypertension was associated with less anticoagulation use in Indigenous compared to non-Indigenous Australians (p=0.02). CONCLUSIONS: Anticoagulation for AF was suboptimal in both Indigenous and non-Indigenous Australians. Older age, female gender, and comorbid vascular disease were found to be negatively associated with anticoagulation. Importantly, hypertension may also be under-recognised as a stroke risk factor in Indigenous Australians. Future efforts to encourage anticoagulation use in accordance with guideline recommendations is likely to reduce the burden of AF-related stroke in both Indigenous and non-Indigenous populations.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Anticoagulantes , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Austrália/epidemiologia , Feminino , Humanos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
7.
Europace ; 22(2): 288-298, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31995177

RESUMO

AIMS: There is growing evidence that magnetic resonance imaging (MRI) scanning in patients with non-conditional cardiac implantable electronic devices (CIEDs) can be performed safely. Here, we aim to assess the safety of MRI in patients with non-conditional CIEDs. METHODS AND RESULTS: English scientific literature was searched using PubMed/Embase/CINAHL with keywords of 'magnetic resonance imaging', 'pacemaker', 'implantable defibrillator', and 'cardiac resynchronization therapy'. Studies assessing outcomes of adverse events or significant changes in CIED parameters after MRI scanning in patients with non-conditional CIEDs were included. References were excluded if the MRI conditionality of the CIEDs was undisclosed; number of patients enrolled was <10; or studies were case reports/series. About 35 cohort studies with a total of 5625 patients and 7196 MRI scans (0.5-3 T) in non-conditional CIEDs were included. The overall incidence of lead failure, electrical reset, arrhythmia, inappropriate pacing and symptoms related to pocket heating, or torque ranged between 0% and 1.43%. Increase in pacing lead threshold >0.5 V and impedance >50Ω was seen in 1.1% [95% confidence interval (CI) 0.7-1.8%] and 4.8% (95% CI 3.3-6.4%) respectively. The incidence of reduction in P- and R-wave sensing by >50% was 1.5% (95% CI 0.6-2.9%) and 0.4% (95% CI 0.06-1.1%), respectively. Battery voltage reduction of >0.04 V was reported in 2.2% (95% CI 0.2-6.1%). CONCLUSION: This meta-analysis affirms the safety of MR imaging in non-conditional CIEDs with no death or implantable cardioverter-defibrillator shocks and extremely low incidence of lead or device-related complications.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Coração , Humanos
8.
Heart Lung Circ ; 29(8): 1122-1128, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31980393

RESUMO

BACKGROUND: Studies have shown that suboptimal anticoagulation quality, as measured by time in therapeutic range (TTR), affects a significant percentage of patients with atrial fibrillation (AF). However, TTR has not been previously characterised in Indigenous Australians who experience a greater burden of AF and stroke. METHOD: Indigenous and non-Indigenous Australians with AF on warfarin anticoagulation therapy were identified from a large tertiary referral centre between 1999 and 2012. Time in therapeutic range was calculated as a proportion of daily international normalised ratio (INR) values between 2 and 3 for non-valvular AF and 2.5 to 3.5 for valvular AF. INR values between tests were imputed using the Rosendaal technique. Linear regression models were employed to characterise predictors of TTR. RESULTS: Five hundred and twelve (512) patients with AF on warfarin were included (88 Indigenous and 424 non-Indigenous). Despite younger age (51±13 vs 71±12 years, p<0.001), Indigenous Australians had greater valvular heart disease, diabetes, and alcohol excess compared to non-Indigenous Australians (p<0.05 for all). Time in therapeutic range was significantly lower in Indigenous compared to non-Indigenous Australians (40±29 vs 50±31%, p=0.006). Univariate predictors of poorer TTR included Indigenous ethnicity, younger age, diuretic use, and comorbidities, such as valvular heart disease, heart failure and chronic obstructive pulmonary disease (p<0.05 for all). Valvular heart disease remained a significant predictor of poorer TTR in multivariate analyses (p=0.004). CONCLUSION: Indigenous Australians experience particularly poor warfarin anticoagulation quality. Our data also suggest that many non-Indigenous Australians spend suboptimal time in therapeutic range. These findings reinforce the importance of monitoring warfarin anticoagulation quality to minimise stroke risk.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Etnicidade , Qualidade da Assistência à Saúde , Acidente Vascular Cerebral/prevenção & controle , Varfarina/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/etnologia , Austrália/epidemiologia , Seguimentos , Humanos , Incidência , Estudos Retrospectivos , Acidente Vascular Cerebral/etnologia , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida/tendências , Resultado do Tratamento
9.
Heart Lung Circ ; 28(1): 76-83, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30482686

RESUMO

Ventricular arrhythmias are one of the leading causes of death in patients with a prior myocardial infarction. Implantable cardioverter-defibrillators (ICDs) are very effective in the prevention of sudden cardiac death but the risk of recurrence remains an issue since defibrillation does not alter the underlying substrate. Recurrent ICD shocks are distressing and are associated with an increase in mortality. Catheter ablation is an effective treatment for recurrent ventricular tachycardia in these patients, particularly when antiarrhythmic therapy produces side effects or is ineffective. This paper reviews the underlying mechanisms of VT in patients with a prior myocardial infarction, and the indications, strategies and outcomes of catheter ablation.


Assuntos
Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Infarto do Miocárdio/complicações , Guias de Prática Clínica como Assunto , Taquicardia Ventricular/cirurgia , Humanos , Taquicardia Ventricular/etiologia , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-29477215

RESUMO

BACKGROUND: It has been suggested that ethnicity can make a significant difference to the likelihood of thromboembolic stroke related to atrial fibrillation. Ethnic differences have been shown to alter inflammatory and haemostatic factors; however, this may all be confounded by differences in cardiovascular risk factors between different ethnicity. The impact of different ethnicities on the thrombogenic profile is not known. The aim of this study was to investigate differences in markers of inflammation, endothelial function and tissue remodelling between Caucasian and Indian populations with supraventricular tachycardia (SVT). METHODS: Patients with structurally normal hearts undergoing catheter ablation for SVT were studied. This study included 23 Australian (Caucasian) patients from the Royal Adelaide Hospital, Adelaide, Australia and 24 Indian (Indian) patients from the Christian Medical College, Vellore, India. Blood samples were collected from the femoral vein, and right and left atria. Blood samples were analysed for the markers of endothelial function (ADMA, ET-1), inflammation (CD40L, VCAM-1, ICAM-1), and tissue remodelling (MMP-9, TIMP-1) using ELISA. RESULTS: The study populations were well matched for cardiovascular risk factors and the absence of structural heart disease. No difference in the echocardiographic measurements between the two ethnicities was found. In this context, there was no difference in markers of inflammation, endothelial function or tissue remodelling between the two SVT populations. CONCLUSION: Caucasian and Indian populations demonstrate similar inflammatory, endothelial function or tissue remodelling profiles. This study suggests a lack of an impact of different ethnicity in these populations in terms of thrombogenic risk.

13.
Pacing Clin Electrophysiol ; 37(5): 616-23, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24372302

RESUMO

BACKGROUND: Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP). METHODS: LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures. RESULTS: A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = -0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients. CONCLUSIONS: A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Pressão Atrial , Ablação por Cateter/efeitos adversos , Peptídeo Natriurético Encefálico/sangue , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/fisiopatologia , Fibrilação Atrial/complicações , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/métodos , Resultado do Tratamento , Desequilíbrio Hidroeletrolítico/diagnóstico
14.
Clin Exp Pharmacol Physiol ; 41(8): 551-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24827644

RESUMO

Patients with atrial fibrillation (AF) are at an increased risk of thromboembolism and stroke primarily from the development of thrombi within the left atrium. Pathological changes in blood constituents and atrial endothelial damage promote left atrial thrombus formation. It is not known whether factors predisposing to left atrial thrombus formation in AF are disease specific or also evident within the normal heart. The present study examined whether there are differences in platelet reactivity, endothelial function and inflammation in blood samples obtained from intracardiac and peripheral sites in subjects within structurally normal hearts. Sixteen patients with diagnosed left-sided supraventricular tachycardia (SVT) undergoing a routine elective electrophysiological study and ablation were investigated. Blood samples were taken simultaneously from the femoral vein, right atrium and left atrium, immediately following trans-septal puncture and prior to heparin bolus administration. Between peripheral and atrial sample sites, patients with SVT showed no change in platelet reactivity or aggregation (P-selectin (CD62P) P = 0.91; platelet-derived soluble CD40 ligand P = 0.9), thrombus formation (thrombin-antithrombin complex; P = 0.55), endothelial function (von Willebrand factor P = 0.75; asymmetric dimethylarginine (ADMA) P = 0.97; nitric oxide P = 0.61), or inflammation (vascular cell adhesion molecule-1 P = 0.59; intercellular adhesion molecule-1 (ICAM-1) P = 0.69). However, SVT patients had lower ADMA and ICAM-1 levels than AF patients. The present study demonstrates, for the first time, that SVT subjects with structurally normal hearts have consistent haemostatic function between atrial and peripheral sites. These results suggest that the atria of SVT patients do not contain predisposing thrombogenic, endothelial or inflammatory factors that promote and/or initiate thrombus formation.


Assuntos
Coração/anatomia & histologia , Inflamação/sangue , Taquicardia Supraventricular/sangue , Trombose/sangue , Adolescente , Adulto , Fibrilação Atrial/sangue , Fibrilação Atrial/metabolismo , Fibrilação Atrial/patologia , Biomarcadores/sangue , Plaquetas/metabolismo , Plaquetas/patologia , Ligante de CD40/metabolismo , Ablação por Cateter/métodos , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Feminino , Veia Femoral/metabolismo , Veia Femoral/patologia , Átrios do Coração/metabolismo , Átrios do Coração/patologia , Humanos , Inflamação/metabolismo , Inflamação/patologia , Molécula 1 de Adesão Intercelular/metabolismo , Masculino , Pessoa de Meia-Idade , Selectina-P/metabolismo , Ativação Plaquetária/fisiologia , Taquicardia Supraventricular/metabolismo , Taquicardia Supraventricular/patologia , Trombose/metabolismo , Trombose/patologia , Adulto Jovem
15.
Eur Heart J ; 34(8): 560-71, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23264584

RESUMO

Ablation has substantial evidence base in the management of ventricular arrhythmia (VA). It can be a 'lifesaving' procedure in the acute setting of VA storm. Current reports on ablation in VA storm are in the form of small series and have relative small representation in a large observational series. The purpose of this study was to systematically synthesize the available literature to appreciate the efficacy and safety of ablation in the setting of VA storm. The medical electronic databases through 31 January 2012 were searched. Ventricular arrhythmia storm was defined as recurrent (≥ 3 episodes or defibrillator therapies in 24 h) or incessant (continuous >12 h) VA. Studies reporting data on VA storm patients at the individual or study level were included. A total of 471 VA storm patients from 39 publications were collated for the analysis. All VAs were successfully ablated in 72% [95% confidence interval (CI) 71-89%] and 9% (95% CI: 3-10%) had a failed procedure. Procedure-related mortality occurred in three patients (0.6%). Only 6% patients had a recurrence of VA storm. The recurrence of VA was significantly higher after ablation for arrhythmic storm of monomorphic ventricular tachycardia (VT) relative to ventricular fibrillation or polymorphic VT with underlying cardiomyopathy (odds ratio 3.76; 95% CI: 1.65-8.57; P = 0.002). During the follow-up (61 ± 37 weeks), 17% of patients died (heart failure 62%, arrhythmias 23%, and non-cardiac 15%) with 55% deaths occurring within 12 weeks of intervention. The odds of death were four times higher after a failed procedure compared with those with a successful procedure (95% CI: 2.04-8.01, P < 0.001). Ventricular arrhythmia storm ablation has high-acute success rates, with a low rate of recurrent storms. Heart failure is the dominant cause of death in the long term. Failure of the acute procedure carries a high mortality.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Adulto , Idoso , Ablação por Cateter/mortalidade , Humanos , Pessoa de Meia-Idade , Recidiva , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Fibrilação Ventricular/mortalidade
16.
Heart Rhythm O2 ; 5(6): 341-350, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38984365

RESUMO

Background: Inpatient monitoring is recommended for sotalol initiation. Objective: The purpose of this study was to assess the safety of outpatient sotalol commencement. Methods: This is a multicenter, retrospective, observational study of patients initiated on sotalol in an outpatient setting. Serial electrocardiogram monitoring at day 3, day 7, 1 month, and subsequently as clinically indicated was performed. Corrected QT (QTc) interval and clinical events were evaluated. Results: Between 2008 and 2023, 880 consecutive patients who were commenced on sotalol were evaluated. Indications were atrial fibrillation/flutter in 87.3% (n = 768), ventricular arrhythmias in 9.9% (n = 87), and other arrhythmias in 2.8% (n = 25). The daily dosage at initiation was 131.0 ± 53.2 mg/d. The QTc interval increased from baseline (431 ± 32 ms) to 444 ± 37 ms (day 3) and 440 ± 33 ms (day 7) after sotalol initiation (P < .001). Within the first week, QTc prolongation led to the discontinuation of sotalol in 4 and dose reduction in 1. No ventricular arrhythmia, syncope, or death was observed during the first week. Dose reduction due to asymptomatic bradycardia occurred in 3 and discontinuation due to dyspnea in 3 within the first week. Overall, 1.1% developed QTc prolongation (>500 ms/>25% from baseline); 4 within 3 days, 1 within 1 week, 4 within 60 days, and 1 after >3 years. Discontinuation of sotalol due to other adverse effects occurred in 41 patients within the first month of therapy. Conclusion: Sotalol initiation in an outpatient setting with protocolized follow-up is safe, with no recorded sotalol-related mortality, ventricular arrhythmias, or syncope. There was a low incidence of significant QTc prolongation necessitating discontinuation within the first month of treatment. Importantly, we observed a small incidence of late QT prolongation, highlighting the need for vigilant outpatient surveillance of individuals on sotalol.

17.
Am J Physiol Heart Circ Physiol ; 305(8): H1181-8, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23934852

RESUMO

QT variability (QTV) signifies repolarization lability, and increased QTV is a risk predictor for sudden cardiac death. The aim of the present study was to investigate the role of autonomic nervous system activity on QTV. This study was performed in 29 subjects: 10 heart failure (HF) patients with spontaneous ventricular tachycardia [HFVT(+)], 10 HF patients without spontaneous VT [HFVT(-)], and 9 subjects with structurally normal hearts (HNorm). The beat-to-beat QT interval was measured on 3-min records of surface ECGs at baseline and during interventions (atrial pacing and esmolol, isoprenaline, and atropine infusion). Variability in QT intervals was expressed as the SD of all QT intervals (SDQT). The ratio of the SDQT to SD of RR intervals (SDRR) was calculated as an index of QTV normalized to heart rate variability. There was a trend toward a higher baseline SDQT-to-SDRR ratio in the HFVT(+) group compared with the HFVT(-) and HNorm groups (P = 0.09). SDQT increased significantly in the HFVT(+) and HFVT(-) groups compared with the HNorm group during fixed-rate atrial pacing (P = 0.008). Compared with baseline, isoprenaline infusion increased SDQT in HNorm subjects (P = 0.02) but not in HF patients. SDQT remained elevated in the HFVT(+) group relative to the HNorm group despite acute ß-adrenoceptor blockade with esmolol (P = 0.02). In conclusion, patients with HF and spontaneous VT have larger fluctuations in beat-to-beat QT intervals. This appears to be a genuine effect that is not solely a consequence of heart rate variation. The effect of acute autonomic nervous system modulation on QTV appears to be limited in HF patients.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Cardiomiopatias/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Adolescente , Antagonistas de Receptores Adrenérgicos beta 1/farmacologia , Agonistas Adrenérgicos beta/farmacologia , Adulto , Idoso , Cardiomiopatias/complicações , Estudos de Casos e Controles , Eletrocardiografia , Feminino , Insuficiência Cardíaca/complicações , Humanos , Isoproterenol/farmacologia , Masculino , Pessoa de Meia-Idade , Propanolaminas/farmacologia , Taquicardia Ventricular/complicações , Adulto Jovem
18.
J Electrocardiol ; 46(1): 66-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23117063

RESUMO

An ECG recorded from a patient with an implanted cardiac pacemaker showed a striking high frequency pulsing on the ST-T segments linked with each QRS complex. In this report we present an approach to the clatter on the ECG and discuss various potential diagnoses that can have closely similar pattern.


Assuntos
Artefatos , Eletrocardiografia/métodos , Idoso de 80 Anos ou mais , Feminino , Humanos
19.
Heart Rhythm ; 20(9): 1297-1306, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37321384

RESUMO

BACKGROUND: Fidelity of electrogram sensing may reduce false alerts from an insertable cardiac monitor (ICM). OBJECTIVE: The purpose of this study was to assess the effect of vector length, implant angle, and patient factors on electrogram sensing using surface electrocardiogram (ECG) mapping. METHODS: Twelve separate precordial single-lead surface ECGs were acquired from 150 participants at 2 interelectrode distances (75 and 45 mm), at 3 vector angles (vertical, oblique, and horizontal), and in 2 postures (upright and supine). A subset of 50 patients also received a clinically indicated ICM implant in 1:1 ratio (Reveal LINQ [Medtronic, Minneapolis, MN]/BIOMONITOR III [Biotronik, Berlin, Germany]). All ECGs and ICM electrograms were analyzed by blinded investigators using DigitizeIt software (V2.3.3, Braunschweig, Germany). The P-wave visibility threshold was set at > 0.015 mV. Logistic regression was used to identify factors affecting P-wave amplitude. RESULTS: A total of 1800 tracings from 150 participants (44.5% [n = 68] female; median age 59 [35-73] years) were assessed. The median P- and R-wave amplitudes were 45% and 53% larger with vector lengths of 75 and 45 mm, respectively (P < .001 for both). The oblique orientation yielded the best P- and R-wave amplitudes, while posture change did not affect P-wave amplitude. Mixed effects modeling found that visible P-waves occur more frequently with a vector length of 75 mm than with 45 mm (86% vs 75%, respectively; P < .0001). A longer vector length improved both P-wave amplitude and visibility in all body mass index categories. There was a moderate correlation of P- and R-wave amplitudes from the ICM electrograms to those from surface ECG recordings (intraclass correlation coefficient 0.74 and 0.80, respectively). CONCLUSION: Longer vector length and oblique implant angle yielded the best electrogram sensing and are relevant considerations for ICM implantation procedures.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Humanos , Feminino , Pessoa de Meia-Idade , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Próteses e Implantes , Software , Alemanha
20.
J Cardiovasc Electrophysiol ; 23(10): 1067-72, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22612914

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and atrial flutter (AFL) are related arrhythmias with common triggers, yet in individual patients either AF or AFL often predominates. We performed detailed electrophysiologic (EP) and electroanatomic (EA) studies of the right atrium (RA) in patients with AF and AFL to determine substrate differences that may explain the preferential expression of AF/AFL in individual patients. METHODS: Patients with AF (n = 13) were compared to patients with persistent AFL (n = 10). Detailed studies were performed, and 3-dimensional electroanatomic mapping studies were created and the RA was divided into 4 segments for regional analysis. Global, septal, lateral, anterior, and posterior segments were compared for analysis of: bipolar voltage; proportion of low-voltage areas and areas of electrical silence; conduction times; and proportion of abnormal signals (fractionated signals and double potentials). RESULTS: Compared to patients with AF, patients with AFL had (1) lower bipolar voltage and an increase in the proportion of low-voltage areas; (2) an increase in the proportion of complex signals; and (3) prolongation of activation times. CONCLUSIONS: Patients with AFL showed more advanced remodeling than patients with AF with slowed conduction, lower voltage areas with regions of electrical silence, and a greater proportion of complex signals, particularly in the posterior RA. These changes facilitate the stabilization of AFL and may explain why some patients are more likely to develop AFL as a sustained clinical arrhythmia.


Assuntos
Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Função do Átrio Direito , Potenciais de Ação , Idoso , Análise de Variância , Fibrilação Atrial/patologia , Flutter Atrial/patologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Período Refratário Eletrofisiológico , Fatores de Tempo , Imagens com Corantes Sensíveis à Voltagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA