Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sleep Breath ; 27(3): 923-932, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35902534

RESUMO

PURPOSE: This study evaluated whether or not polysomnography (PSG) inter-scorer reliability (ISR) across sleep centres could be improved by external proficiency testing (EPT), or by EPT combined with method alignment training. METHODS: Experienced scorers form 15 sleep centres were randomised to the following: (1) a control group, (2) a group that received a self-directed intervention of EPT reports (EPTPassive) or (3) a group that received an active intervention of method alignment training and EPT reports (EPTActive). Respiratory, arousal and sleep scoring ISR from sixteen PSG fragments were compared between groups across time. RESULTS: Among 30 scorers, there were no ISR changes in controls between baseline (BL) and 6 months (6 m). Both EPT groups showed ISR improvement from BL to 6 m for respiratory, arousal and sleep scoring (p < 0.05). Respiratory scoring back-transformed mean (95CI) proportion of specific agreement (PSA) for the EPTPassive group improved from 0.78 (0.72-0.84) to 0.80 (0.74-0.86) and for the EPTActive group from 0.80 (0.74-0.85) to 0.82 (0.76-0.88). Arousal scoring PSA for the EPTPassive group improved from 0.72 (0.66-0.77) to 0.74 (0.69-0.79) and for the EPTActive group from 0.71 (0.65-0.76) to 0.77 (0.72-0.82). Sleep scoring kappa for the EPTPassive group improved from 0.64 (0.58-0.69) to 0.73 (0.68-0.77) and for the EPTActive group from = 0.75 (0.71-0.80) to 0.80 (0.76-0.85). Overall, poorer performers achieved greater improvement. CONCLUSION: External proficiency testing produced modest, statistically significant PSG inter-scorer reliability improvements among experienced scorers across sleep centres, with potential to improve clinical management of individual patients and increase research study statistical power.


Assuntos
Apneia Obstrutiva do Sono , Sono , Humanos , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia
2.
Spinal Cord ; 57(5): 372-379, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30626976

RESUMO

STUDY DESIGN: Descriptive study. OBJECTIVES: To determine the effect of respiratory event rule-set changes on the apnoea hypopnoea index, and diagnostic and severity thresholds in people with acute and chronic spinal cord injury. SETTING: Eleven acute spinal cord injury inpatient hospitals across Australia, New Zealand, Canada and England; community dwelling chronic spinal cord injury patients in their own homes. METHODS: Polysomnography of people with acute (n = 24) and chronic (n = 78) tetraplegia were reanalysed from 1999 American Academy of Sleep Medicine (AASM) respiratory scoring, to 2007 AASM 'alternative' and 2012 AASM respectively. Equivalent cut points for published 1999 AASM sleep disordered breathing severity ranges were calculated using receiver operator curves, and results presented alongside analyses from the able-bodied. RESULTS: In people with tetraplegia, shift from 1999 AASM to 2007 AASM 'alternative' resulted in a 22% lower apnoea hypopnoea index, and to 2012 AASM a 17% lower index. In people with tetraplegia, equivalent cut-points for 1999 AASM severities of 5,15 and 30 were calculated at 2.4, 8.1 and 16.3 for 2007 AASM 'alternative' and 3.2, 10.0 and 21.2 for 2012 AASM. CONCLUSION: Interpreting research, prevalence and clinical polysomnography results conducted over different periods requires knowledge of the relationship between different rule-sets, and appropriate thresholds for diagnosis of disease. SPONSORSHIP: This project was proudly supported by the Traffic Accident Commission (Program grant) and the National Health and Medical Research Council (PhD stipend 616605).


Assuntos
Índice de Gravidade de Doença , Síndromes da Apneia do Sono/classificação , Síndromes da Apneia do Sono/diagnóstico , Traumatismos da Medula Espinal/classificação , Traumatismos da Medula Espinal/diagnóstico , Adolescente , Adulto , Idoso , Apneia/classificação , Apneia/diagnóstico , Apneia/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/classificação , Polissonografia/métodos , Síndromes da Apneia do Sono/epidemiologia , Traumatismos da Medula Espinal/epidemiologia , Adulto Jovem
3.
J Physiol ; 596(14): 2853-2864, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29658103

RESUMO

KEY POINTS: Protective reflexes in the throat area (upper airway) are crucial for breathing. Impairment of these reflexes can cause breathing problems during sleep such as obstructive sleep apnoea (OSA). OSA is very common in people with spinal cord injury for unknown reasons. This study shows major changes in protective reflexes that serve to keep the upper airway open in response to suction pressures in people with tetraplegia and OSA. These results help us understand why OSA is so common in people with tetraplegia and provide new insight into how protective upper airway reflexes work more broadly. ABSTRACT: More than 60% of people with tetraplegia have obstructive sleep apnoea (OSA). However, the specific causes are unknown. Genioglossus, the largest upper-airway dilator muscle, is important in maintaining upper-airway patency. Impaired genioglossus muscle function following spinal cord injury may contribute to OSA. This study aimed to determine if genioglossus reflex responses to negative upper-airway pressure are altered in people with OSA and tetraplegia compared to non-neurologically impaired able-bodied individuals with OSA. Genioglossus reflex responses measured via intramuscular electrodes to ∼60 brief (250 ms) pulses of negative upper-airway pressure (∼-15 cmH2 O at the mask) were compared between 13 participants (2 females) with tetraplegia plus OSA and 9 able-bodied controls (2 females) matched for age and OSA severity. The initial short-latency excitatory reflex response was absent in 6/13 people with tetraplegia and 1/9 controls. Genioglossus reflex inhibition in the absence of excitation was observed in three people with tetraplegia and none of the controls. When the excitatory response was present, it was significantly delayed in the tetraplegia group compared to able-bodied controls: excitation onset latency (mean ± SD) was 32 ± 16 vs. 18 ± 9 ms, P = 0.045; peak excitation latency was 48 ± 17 vs. 33 ± 8 ms, P = 0.038. However, when present, amplitude of the excitation response was not different between groups, 195 ± 26 vs. 219 ± 98% at baseline, P = 0.55. There are major differences in genioglossus reflex morphology and timing in response to rapid changes in airway pressure in people with tetraplegia and OSA. Altered genioglossus function may contribute to the increased risk of OSA in people with tetraplegia. The precise mechanisms mediating these differences are unknown.


Assuntos
Músculos Faríngeos/fisiologia , Quadriplegia/fisiopatologia , Reflexo , Apneia Obstrutiva do Sono/fisiopatologia , Respiradores de Pressão Negativa , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Sleep Med ; 109: 202-210, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37478656

RESUMO

OBJECTIVES: To assess the utility of a tailored intervention program to improve continuous positive airway pressure (CPAP) use and self-efficacy in individuals with obstructive sleep apnea (OSA). METHODS: 81 participants (mean age 52.1 ± 11.6 years; 35 females) with OSA were randomized to either a multi-dimensional intervention (PSY CPAP, n = 38) or treatment as usual (TAU CPAP, n = 43). The intervention included a psychoeducation session prior to CPAP initiation, a booster psychoeducation session in the first weeks of commencing CPAP, follow-up phone calls on days 1 and 7, and a review appointment on day 14. CPAP use was compared between the PSY CPAP and TAU CPAP groups at 1 week, 1 month, and 4 months. Self-efficacy scores (risk perception, outcome expectancies, and CPAP self-efficacy) were compared between groups following the initial psychoeducation session and again at 1 month and 4 months. RESULTS: CPAP use was higher in the PSY CPAP group compared to the TAU CPAP group for all time points (p = .02). Outcome expectancies improved significantly over time in PSY CPAP participants (p = .007). Change in risk perception was associated with CPAP use at 1 week (p = .02) for PSY CPAP participants. However, risk perception did not mediate the effect between group and CPAP use at 1 week. CONCLUSIONS: Interventions designed to increase self-efficacy and administered prior to CPAP initiation, repeated in the early stages of CPAP therapy, and combined with a comprehensive follow-up regime are likely to improve CPAP use. Sustained improvement in CPAP use is the ultimate goal but remains to be investigated.


Assuntos
Autoeficácia , Apneia Obstrutiva do Sono , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Motivação , Cognição , Cooperação do Paciente
5.
Ann Am Thorac Soc ; 20(10): 1445-1455, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37390359

RESUMO

Rationale: Clinical care guidelines advise that lung volume recruitment (LVR) be performed routinely by people with neuromuscular disease (NMD) to maintain lung and chest wall flexibility and slow lung function decline. However, the evidence base is limited, and no randomized controlled trials of regular LVR in adults have been published. Objectives: To evaluate the effect of regular LVR on respiratory function and quality of life in adults with NMD. Methods: A randomized controlled trial with assessor blinding was conducted between September 2015 and May 2019. People (>14 years old) with NMD and vital capacity <80% predicted were eligible, stratified by disease subgroup (amyotrophic lateral sclerosis/motor neuron disease or other NMDs), and randomized to 3 months of twice-daily LVR or breathing exercises. The primary outcome was change in maximum insufflation capacity (MIC) from baseline to 3 months, analyzed using a linear mixed model approach. Results: Seventy-six participants (47% woman; median age, 57 [31-68] years; mean baseline vital capacity, 40 ± 18% predicted) were randomized (LVR, n = 37). Seventy-three participants completed the study. There was a statistically significant difference in MIC between groups (linear model interaction effect P = 0.002, observed mean difference, 0.19 [0.00-0.39] L). MIC increased by 0.13 (0.01-0.25) L in the LVR group, predominantly within the first month. No interaction or treatment effects were observed in secondary outcomes of lung volumes, respiratory system compliance, and quality of life. No adverse events were reported. Conclusions: Regular LVR increased MIC in a sample of LVR-naive participants with NMD. We found no direct evidence that regular LVR modifies respiratory mechanics or slows the rate of lung volume decline. The implications of increasing MIC are unclear, and the change in MIC may represent practice. Prospective long-term clinical cohorts with comprehensive follow-up, objective LVR use, and clinically meaningful outcome data are needed. Clinical trial registered with anzctr.org.au (ACTRN12615000565549).


Assuntos
Doenças Neuromusculares , Qualidade de Vida , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Adolescente , Estudos Prospectivos , Medidas de Volume Pulmonar , Pulmão , Doenças Neuromusculares/complicações
6.
Telemed J E Health ; 18(8): 634-40, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22957501

RESUMO

BACKGROUND: Remote in-home monitoring (RM) of symptoms and physiological variables may allow early detection and treatment of exacerbations of chronic obstructive pulmonary disease (COPD). It is unclear whether RM improves patient outcomes or healthcare resource utilization. This study determined whether RM is feasible in patients with COPD and if RM reduces hospital admissions or length of stay (LOS) or improves health-related quality of life (HRQOL). SUBJECTS AND METHODS: Forty-four patients were randomized to standard best practice care (SBP) (n=22) or SBP+RM (n=22). RM involved daily recording of physiological variables, symptoms, and medication usage. RESULTS: There were no differences (mean±SD, SBP versus SBP+RM) in age (68±8 versus 70±9 years), gender (male:female 10:12 in both groups), or previous computer familiarity (59% versus 50%) between groups. The SBP group had a lower forced expiratory volume in 1 s (0.66±0.24 versus 0.91±0.34 L, p<0.01) and more current smokers (six versus none, p<0.05). There were no differences in number of COPD-related admissions/year (1.5±1.8 versus 1.3±1.7, p=0.76), COPD-related LOS days/year (15.6±19.4 versus 11.4±19.6, p=0.66), total admissions/year (2.2±2.1 versus 2.0±2.3, p=0.86), total LOS days/year (22.1±29.9 versus 21.6±30.4, p=0.88), or HRQOL between the two groups. CONCLUSIONS: The addition of RM to SBP was feasible but did not reduce healthcare utilization or improve quality of life in this group of patients already receiving comprehensive respiratory care.


Assuntos
Monitorização Fisiológica/métodos , Doença Pulmonar Obstrutiva Crônica/psicologia , Telemedicina/métodos , Idoso , Austrália , Benchmarking , Intervalos de Confiança , Feminino , Humanos , Tempo de Internação , Masculino , Assistência ao Paciente/normas , Projetos Piloto , Doença Pulmonar Obstrutiva Crônica/patologia , Qualidade de Vida/psicologia , Testes de Função Respiratória , Estatísticas não Paramétricas , Telemedicina/organização & administração
7.
Respir Care ; 56(4): 442-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21255486

RESUMO

BACKGROUND: When polysomnography is indicated in a patient with a presumed sleep disorder, continuous monitoring of arterial carbon dioxide tension (P(aCO(2))) is desirable, especially if nocturnal hypoventilation is suspected. Transcutaneous CO(2) monitors (P(tcCO(2))) provide a noninvasive correlate of P(aCO(2)), but their accuracy and stability over extended monitoring have been considered inadequate for the diagnosis of hypoventilation. We examined the stability and accuracy of P(tcCO(2)) measurements and the performance of a previously described linear interpolation technique designed to correct for calibration drift. METHODS: We compared the P(tcCO(2)) values from 2 TINA TCM-3 monitors to P(aCO(2)) values from arterial blood samples obtained at the beginning, every 15 min of the first hour, and then hourly over 8 hours of monitoring in 6 hemodynamically stable, male, intensive care patients (mean age 46 ± 17 y). RESULTS: Time had a significant (P = .002) linear effect on the P(tcCO(2))-P(aCO(2)) difference, suggesting calibration drift over the monitoring period. We found no differences between monitor type or interaction between time and monitor type. For the 2 monitors the uncorrected bias was 3.6 mm Hg and the limits of agreement were -5.1 to 12.3 mm Hg. Our linear interpolation algorithm improved the bias and limits of agreement to 0.4 and -5.5 to 6.4 mm Hg, respectively. CONCLUSIONS: Following stabilization and correction for both offset and drift, P(tcCO(2)) tracks P(aCO(2)) with minimal residual bias over 8 hours of monitoring. Should future research confirm these findings, then interpolated P(tcCO(2)) may have an increased role in detecting sleep hypoventilation and assessing the efficacy of treatment.


Assuntos
Algoritmos , Monitorização Transcutânea dos Gases Sanguíneos , Dióxido de Carbono/análise , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Idoso , Calibragem , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Reprodutibilidade dos Testes , Fatores de Tempo
8.
Sleep ; 32(2): 150-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19238801

RESUMO

STUDY OBJECTIVES: To compare apnea-hypopnea indices (AHIs) derived using 3 standard hypopnea definitions published by the American Academy of Sleep Medicine (AASM); and to examine the impact of hypopnea definition differences on the measured prevalence of obstructive sleep apnea (OSA). DESIGN: Retrospective review of previously scored in-laboratory polysomnography (PSG). SETTING: Two tertiary-hospital clinical sleep laboratories. PATIENTS OR PARTICIPANTS: 328 consecutive patients investigated for OSA during a 3-month period. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: AHIs were originally calculated using previous AASM hypopnea scoring criteria (AHI(Chicago)), requiring either >50% airflow reduction or a lesser airflow reduction with associated >3% oxygen desaturation or arousal. AHIs using the "recommended" (AHI(Rec)) and the "alternative" (AHI(Alt)) hypopnea definitions of the AASM Manual for Scoring of Sleep and Associated Events were then derived in separate passes of the previously scored data. In this process, hypopneas that did not satisfy the stricter hypopnea definition criteria were removed. For AHI(Rec), hypopneas were required to have > or =30% airflow reduction and > or =4% desaturation; and for AHI(Alt), hypopneas were required to have > or =50% airflow reduction and > or =3% desaturation or arousal. The median AHI(Rec) was approximately 30% of the median AHI(Chicago), whereas the median AHI(Alt), was approximately 60% of the AHI(Chicago), with large, AHI-dependent, patient-specific differences observed. Equivalent cut-points for AHI(Rec) and AHI(Alt), compared to AHI(Chicago) cut-points of 5, 15, and 30/h were established with receiver operator curves (ROC). These cut-points were also approximately 30% of AHI(Chicago) using AHI(Rec) and 60% of AHI(Chicago) using AHI(Alt). Failure to adjust cut-points for the new criteria would result in approximately 40% of patients previously classifled as positive for OSA using AHI(Chicago) being negative using AHI(Rec) and 25% being negative using AHI(Alt). CONCLUSIONS: This study demonstrates that using different published standard hypopnea definitions leads to marked differences in AHI. These results provide insight to clinicians and researchers in interpreting results obtained using different published standard hypopnea definitions, and they suggest that consideration should be given to revising the current scoring recommendations to include a single standardized hypopnea definition.


Assuntos
Polissonografia/classificação , Guias de Prática Clínica como Assunto , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Comparação Transcultural , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Polissonografia/normas , Valores de Referência , Estudos Retrospectivos , Apneia Obstrutiva do Sono/classificação , Apneia Obstrutiva do Sono/epidemiologia , Estados Unidos , Vitória
9.
Respir Physiol Neurobiol ; 259: 93-103, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30130628

RESUMO

Respiratory related evoked potentials (RREP) were used to examine respiratory stimulus gating. RREPs produced by consciously detected vs. undetected loads, near the detection threshold, were compared. Participants (n = 17) were instrumented with EEG and a nasal mask connected to a loading manifold, which presented a range of mid-inspiratory resistive loads, plus a control, in a random block design. Participants were cued prior to the stimulus and signalled detection by a button press. There were statistically significant differences in peak-to-peak amplitude of the P1 RREP peak for detected (mean ± SD; 3.86 ± 1.45 µV; P = 0.020) and undetected loads (3.67 ± 1.27 µV; P = 0.002) vs. control (2.36 ± 0.81 µV), although baseline-to-peak differences were not significantly different. In contrast peak-to-peak P3 amplitude was significantly greater for detected (5.91 ± 1.54 µV; P < 0.001) but not undetected loads (3.33 ± 0.98 µV; P = 0.189) vs. control (3.69 ± 1.46 µV), with the same pattern observed for baseline-to-peak measurements. The P1 peak, thought to reflect arrival of somatosensory information, appeared to be present in response to both detected and undetected loads, but the later P3 peak, was present for detected loads only. This suggests that for sub-threshold loads sensory information may reach the cortex, arguing against a sub-cortical gating process.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Estado de Consciência/fisiologia , Filtro Sensorial/fisiologia , Adulto , Análise de Variância , Eletroencefalografia , Eletroculografia , Potenciais Somatossensoriais Evocados/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação/fisiologia
10.
Sleep ; 42(10)2019 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-31322697

RESUMO

STUDY OBJECTIVES: Low lung volumes are thought to contribute to obstructive sleep apnea (OSA). OSA is worse in the supine versus lateral body position, men versus women, obese versus normal-weight (NW) individuals and REM versus NREM sleep. All of these conditions may be associated with low lung volumes. The aim was to measure FRC during wake, NREM, and REM in NW and overweight (OW) men and women while in the supine and lateral body positions. METHODS: Eighty-one healthy adults were instrumented for polysomnography, but with nasal pressure replaced with a sealed, non-vented mask connected to an N2 washout system. During wakefulness and sleep, repeated measurements of FRC were made in both supine and right lateral positions. RESULTS: Two hundred eighty-five FRC measures were obtained during sleep in 29 NW (body mass index [BMI] = 22 ± 0.3 kg/m2) and 29 OW (BMI = 29 ± 0.7 kg/m2) individuals. During wakefulness, FRC differed between BMI groups and positions (supine: OW = 58 ± 3 and NW = 68 ± 3% predicted; lateral OW = 71 ± 3, NW = 81 ± 3% predicted). FRC fell from wake to NREM sleep in all participants and in both positions by a similar amount. As a result, during NREM sleep FRC was lower in OW than NW individuals (supine 46 ± 3 and 56 ± 3% predicted, respectively). FRC during REM was similar to NREM and no sex differences were observed in any position or sleep stage. CONCLUSIONS: Reductions in FRC while supine and with increased body weight may contribute to worsened OSA in these conditions, but low lung volumes appear unlikely to explain the worsening of OSA in REM and in men versus women.


Assuntos
Peso Corporal/fisiologia , Pulmão/fisiologia , Polissonografia/métodos , Caracteres Sexuais , Apneia Obstrutiva do Sono/fisiopatologia , Sono/fisiologia , Adulto , Feminino , Humanos , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Sobrepeso/diagnóstico , Sobrepeso/fisiopatologia , Apneia Obstrutiva do Sono/diagnóstico , Decúbito Dorsal/fisiologia , Vigília/fisiologia
11.
J Appl Physiol (1985) ; 127(6): 1586-1598, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31647723

RESUMO

This study aimed to determine whether there is impairment of genioglossus neuromuscular responses to small negative pressure respiratory stimuli, close to the conscious detection threshold, in obstructive sleep apnea (OSA). We compared genioglossus electromyogram (EMGgg) responses to midinspiratory resistive loads of varying intensity (≈1.2-6.2 cmH2O·L-1·s), delivered via a nasal mask, between 16 severe OSA and 17 control participants while the subjects were awake and in a seated upright position. We examined the relationship between stimulus intensity and peak EMGgg amplitude in a 200-ms poststimulus window and hypothesized that OSA patients would have an increased activation threshold and reduced sensitivity in the relationship between EMGgg activation and stimulus intensity. There was no significant difference between control and OSA participants in the threshold (P = 0.545) or the sensitivity (P = 0.482) of the EMGgg amplitude vs. stimulus intensity relationship, where change in epiglottic pressure relative to background epiglottic pressure represented stimulus intensity. These results do not support the hypothesis that deficits in neuromuscular response to negative upper airway pressure exist in OSA during wakefulness; however, the results are likely influenced by a counterintuitive and novel genioglossus muscle suppression response observed in a significant proportion of both OSA and healthy control participants. This suppression response may relate to the inhibition seen in inspiratory muscles such as the diaphragm in response to sudden-onset negative pressure, and its presence provides new insight into the upper airway neuromuscular response to the collapsing force of negative pressure.NEW & NOTEWORTHY Our study used a novel midinspiratory resistive load stimulus to study upper airway neuromuscular responses to negative pressure during wakefulness in obstructive sleep apnea (OSA). Although no differences were found between OSA and healthy groups, the study uncovered a novel and unexpected suppression of neuromuscular activity in a large proportion of both OSA and healthy participants. The unusual response provides new insight into the upper airway neuromuscular response to the collapsing force of negative pressure.


Assuntos
Músculos Faciais/fisiopatologia , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Eletromiografia/métodos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Desempenho Psicomotor/fisiologia , Sono/fisiologia , Vigília/fisiologia
12.
Sleep ; 40(11)2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29029284

RESUMO

Objectives: Ventilatory after-discharge (sustained elevation of ventilation following stimulus removal) occurs during sleep but not when hypocapnia is present. Genioglossus after-discharge also occurs during sleep, but CO2 effects have not been assessed. The relevance is that postarousal after-discharge may protect against upper airway collapse. This study aimed to determine whether arousal elicits genioglossus after-discharge that persists into sleep, and whether it is influenced by CO2. Methods: Twenty-four healthy individuals (6 female) slept with a nasal mask and ventilator. Sleep (EEG, EOG, EMG), ventilation (pneumotachograph), end-tidal CO2 (PETCO2), and intramuscular genioglossus EMG were monitored. NREM eucapnia was determined during 5 minutes on continuous positive airway pressure (4 cmH2O). Inspiratory pressure support was increased until PETCO2 was ≥2 mm Hg below NREM eucapnia. Supplemental CO2 was added to reproduce normocapnia, without changing ventilator settings. Arousals were induced by auditory tones and genioglossus EMG compared during steady-state hypocapnia and normocapnia. Results: Eleven participants (4 female) provided data. Prearousal PETCO2 was less (p < .05) during hypocapnia (40.74 ± 2.37) than normocapnia (43.82 ± 2.89), with differences maintained postarousal. After-discharge, defined as an increase in genioglossus activity above prearousal levels, occurred following the return to sleep. For tonic activity, after-discharge lasted four breaths irrespective of CO2 condition. For peak activity, after-discharge lasted one breath during hypocapnia and 6 breaths during normocapnia. However, when peak activity following the return to sleep was compared between CO2 conditions no individual breath differences were observed. Conclusions: Postarousal genioglossal after-discharge may protect against upper airway collapse during sleep. Steady-state CO2 levels minimally influence postarousal genioglossus after-discharge.


Assuntos
Nível de Alerta , Dióxido de Carbono/metabolismo , Músculos Faciais , Sono/fisiologia , Língua , Pressão Positiva Contínua nas Vias Aéreas , Eletromiografia , Feminino , Voluntários Saudáveis , Humanos , Hipocapnia/metabolismo , Masculino , Respiração , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Volume de Ventilação Pulmonar , Adulto Jovem
13.
Respir Physiol Neurobiol ; 236: 29-41, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27836649

RESUMO

Respiratory related evoked potentials (RREPs) were used to investigate whether sensory detection of small mid-inspiratory resistive loads (≈1.2-6.2 cmH2OL-1s), delivered during wakefulness, was impaired in obstructive sleep apnoea (OSA). It was reasoned that impaired detection of minor airway patency challenge may lead to difficult-to-remedy further collapse. There was a significant reduction in OSA (n=16) vs. control (n=17) participants in the slope of the relationship between the P1 RREP component amplitude, which reflects arrival of somatosensory information at the cortex, and stimulus intensity, expressed as change in epiglottic pressure (mean [95% confidence intervals]: -0.50 [-0.97, -0.03] vs. -1.78 [-2.54, -1.02]; P=0.004), suggesting a reduction in sensitivity to small respiratory loads. However there was no significant difference in sensitivity after background Pepi was taken into account (P=0.268). Additionally, there were no significant group differences in the threshold of the P1 amplitude/stimulus intensity relationship, or in the P1 latency. These results indicate a reduced sensitivity to detection of small upper airway negative pressure stimuli in OSA related to a reduction in mechanoreceptor activation (likely related to increased airway resistance in OSA vs. controls; P=0.002) rather than defective mechanosensory function.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Limiar Sensorial/fisiologia , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Biofísica , Córtex Cerebral/fisiopatologia , Eletroencefalografia , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação/fisiologia , Apneia Obstrutiva do Sono/patologia
14.
Sleep ; 40(6)2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28419356

RESUMO

Study Objectives: To determine whether arousals that terminate obstructive events in obstructive sleep apnea (OSA) (1) induce hypocapnia and (2) subsequently reduce genioglossus muscle activity following the return to sleep. Methods: Thirty-one untreated patients with OSA slept instrumented with sleep staging electrodes, nasal mask and pneumotachograph, end-tidal CO2 monitoring, and intramuscular genioglossus electrodes. End-tidal CO2 was monitored, and respiratory arousals were assigned an end-arousal CO2 change value (PETCO2 on the last arousal breath minus each individual's wakefulness PETCO2). This change value, in conjunction with the normal sleep related increase in PETCO2, was used to determine whether arousals induced hypocapnia and whether the end-arousal CO2 change was associated with genioglossus muscle activity on the breaths following the return to sleep. Results: Twenty-four participants provided 1137 usable arousals. Mean ± SD end-arousal CO2 change was -0.2 ± 2.4 mm Hg (below wakefulness) indicating hypocapnia typically developed during arousal. Following the return to sleep, genioglossus muscle activity did not fall below prearousal levels and was elevated for the first two breaths. End-arousal CO2 change and genioglossus muscle activity were negatively associated such that a 1 mm Hg decrease in end-arousal CO2 was associated with an ~2% increase in peak and tonic genioglossus muscle activity on the breaths following the return to sleep. Conclusions: Arousal-induced hypocapnia did not result in reduced dilator muscle activity following return to sleep, and thus hypocapnia may not contribute to further obstructions via this mechanism. Elevated dilator muscle activity postarousal is likely driven by non-CO2-related stimuli.


Assuntos
Nível de Alerta/fisiologia , Hipocapnia/complicações , Hipocapnia/fisiopatologia , Músculo Esquelético/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Língua/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sono/fisiologia , Vigília/fisiologia , Adulto Jovem
15.
J Appl Physiol (1985) ; 121(5): 1169-1177, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27763876

RESUMO

Respiratory magnetometers are increasingly being used in sleep studies to measure changes in end-expiratory lung volume (EELV), including in obese obstructive sleep apnea patients. Despite this, the accuracy of magnetometers has not been confirmed in obese patients nor compared between sexes. Thus we compared spirometer-measured and magnetometer-estimated lung volume and tidal volume changes during voluntary end-expiratory lung volume changes of 1.5, 1, and 0.5 l above and 0.5 l below functional respiratory capacity in supine normal-weight [body mass index (BMI) < 25 kg/m] and healthy obese (BMI > 30 kg/m) men and women. Two different magnetometer calibration techniques proposed by Banzett et al. [Banzett RB, Mahan ST, Garner DM, Brughera A, Loring SH. J Appl Physiol (1985) 79: 2169-2176, 1995] and Sackner et al. [Sackner MA, Watson H, Belsito AS, Feinerman D, Suarez M, Gonzalez G, Bizousky F, Krieger B. J Appl Physiol (1985) 66: 410-420, 1989] were assessed. Across all groups and target volumes, magnetometers overestimated spirometer-measured EELV by ~65 ml (<0.001) with no difference between techniques (0.07). The Banzett method overestimated the spirometer EELV change in normal-weight women for all target volumes except +0.5 l, whereas no differences between mass or sex groups were observed for the Sackner technique. The variability of breath-to-breath measures of EELV was significantly higher for obese compared with nonobese subjects and was higher for the Sackner than Banzett technique. On the other hand, for tidal volume, both calibration techniques underestimated spirometer measurements (<0.001), with the underestimation being more marked for the Banzett than Sackner technique (0.03), in obese than normal weight (<0.001) and in men than in women (0.003). These results indicate that both body mass and sex affect the accuracy of respiratory magnetometers in measuring EELV and tidal volume.


Assuntos
Pulmão/fisiologia , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Adulto , Índice de Massa Corporal , Feminino , Humanos , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Obesidade/fisiopatologia , Respiração , Apneia Obstrutiva do Sono/fisiopatologia , Adulto Jovem
16.
J Clin Sleep Med ; 12(11): 1487-1492, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27568894

RESUMO

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is common in individuals with tetraplegia and associated with adverse health outcomes. The causes of the high prevalence of OSA in this population are unknown, but it is important to understand as standard treatments are poorly tolerated in tetraplegia. Nasal congestion is common in tetraplegia, possibly because of unopposed parasympathetic activity. Further, nasal obstruction can induce OSA in healthy individuals. We therefore aimed to compare nasal resistance before and after topical administration of a sympathomimetic between 10 individuals with tetraplegia (T) and 9 able-bodied (AB) controls matched for OSA severity, gender, and age. METHODS: Nasal, pharyngeal, and total upper airway resistance were calculated before and every 2 minutes following delivery of ≈0.05 mL of 0.5% atomized phenylephrine to the nostrils and pharyngeal airway. The surface tension of the upper airway lining liquid was also assessed. RESULTS: At baseline, individuals with tetraplegia had elevated nasal resistance (T = 7.0 ± 1.9, AB = 3.0 ± 0.6 cm H2O/L/s), that rapidly fell after phenylephrine (T = 2.3 ± 0.4, p = 0.03 at 2 min) whereas the able-bodied did not change (AB = 2.5 ± 0.5 cm H2O/L/s, p = 0.06 at 2 min). Pharyngeal resistance was non-significantly higher in individuals with tetraplegia than controls at baseline (T = 2.6 ± 0.9, AB = 1.2 ± 0.4 cm H2O/L/s) and was not altered by phenylephrine in either group. The surface tension of the upper airway lining liquid did not differ between groups (T = 64.3 ± 1.0, AB = 62.7 ± 0.6 mN/m). CONCLUSIONS: These data suggest that the unopposed parasympathetic activity in tetraplegia increases nasal resistance, potentially contributing to the high occurrence of OSA in this population.


Assuntos
Resistência das Vias Respiratórias/efeitos dos fármacos , Fenilefrina/uso terapêutico , Quadriplegia/complicações , Simpatomiméticos/uso terapêutico , Administração Tópica , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nariz , Fenilefrina/administração & dosagem , Simpatomiméticos/administração & dosagem , Adulto Jovem
17.
Respir Physiol Neurobiol ; 146(2-3): 205-14, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15766908

RESUMO

We evaluated the effects of inhomogeneity of ventilation on single-breath (SB), rebreathing (RB) and open circuit (OC) D(L)CO using a mathematical model consisting of two alveolar compartments and a common dead space. Inhomogeneity in ventilation was studied by altering inspired volume, initial alveolar volume and compartment size independently. When distribution of inspired volume between alveolar compartments was inhomogeneous (9:1), D(L)CO was underestimated by 35% for SB, 25% for RB, and 16% for OC, and there was an underestimation in V(A) of 9%, 15% and 9%, respectively. With inhomogeneity in initial alveolar volume there was an overestimation in D(L)CO of 13%, 7% and 11% for SB, RB and OC techniques and an underestimation of V(A) of 7%, 12% and 9%. Finally inhomogeneity of compartment size led to an underestimation of D(L)CO of 18%, 35% and 36% with no change in measured V(A). These results suggest D(L)CO measurements are sensitive to inhomogeneity of ventilation, and importantly, all techniques were at times, significantly in error.


Assuntos
Modelos Biológicos , Capacidade de Difusão Pulmonar/fisiologia , Ventilação Pulmonar/fisiologia , Respiração/imunologia , Algoritmos , Humanos , Medidas de Volume Pulmonar/métodos , Testes de Função Respiratória/métodos , Capacidade Pulmonar Total/fisiologia
18.
J Clin Neurosci ; 12(6): 632-7, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16115548

RESUMO

Prevalence of sleep-disordered breathing (SDB) (apnea-hypopnea index [AHI] > or = 5) in acute stroke patients ranges between 44% and 95%, compared to the community prevalence, 9 to 35% for women and 8 to 57% for men [age range 30-60 years]. Limited data exists beyond 3 months following stroke. We assessed the prevalence of SDB amongst stroke survivors at 3 years and compared results to data reported in normal and elderly populations. 90/143 eligible stroke survivors from an existing cohort underwent a home based sleep study. Mean age of the 78 subjects with a valid sleep study was 64 years (SD 15). Prevalence of SDB (AHI > or = 5) was 81% (95% CI 72% to 90%) and sleep apnoea syndrome (AHI > or = 5 plus ESS score > or =11) was 20% (95% CI 11% to 29%). Important predictors for AHI > or = 15 were haemorrhagic stroke (aOR12.06 [1.42-102.74]) and stroke severity at 1 month (aOR4.15 [1.05-16.38]). Large case-control studies are needed.


Assuntos
Polissonografia/métodos , Síndromes da Apneia do Sono/epidemiologia , Síndromes da Apneia do Sono/etiologia , Acidente Vascular Cerebral , Adulto , Doença Crônica , Estudos Transversais , Demografia , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Inquéritos e Questionários , Sobreviventes
19.
Sleep Med ; 16(1): 173-80, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25547033

RESUMO

OBJECTIVE: This study examined the impact of using two abbreviated signal montages on the accuracy, precision and inter-scorer reliability of polysomnography (PSG) sleep and arousal scoring, compared to a standard reference montage, in a cohort of patients investigated for obstructive sleep apnoea (OSA). One abbreviated montage incorporated two signals dedicated to sleep and arousal scoring, and the other incorporated a single signal. METHODS: Four scorers from two laboratories each scored 15 PSGS four times in random order: once using each abbreviated montage and twice using the reference montage. RESULTS: Use of the two-signal montage resulted in small changes in the distribution of sleep stages, a reduction in the arousal index and resultant reductions in sleep and arousal scoring agreement. For the one-signal montage, although similar magnitude sleep stage distribution changes were observed, there were larger reductions in the arousal index, and sleep and arousal scoring accuracy. Additionally, using the one-signal montage, there were statistically significant reductions in the precision of summary statistics including total sleep time (TST) and the amount of rapid eye movement (REM) sleep scored, and reductions in the inter-scorer reliability of REM sleep and arousal scoring. CONCLUSIONS: These findings demonstrate that abbreviated signal montages may result in underestimation of the arousal index and, depending on the montage, poorer precision in TST and REM sleep scoring, with potential consequences for apnoea-hypopnoea index (AHI) measures and OSA diagnosis. The results highlight the importance of careful evaluation of PSG results when using portable devices that have restricted signals, and they offer guidance for future PSG and portable monitoring standards.


Assuntos
Nível de Alerta/fisiologia , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Sono/fisiologia , Adulto , Eletroencefalografia , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/fisiopatologia
20.
Artif Intell Med ; 63(1): 51-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25704112

RESUMO

BACKGROUND: The use of telehealth technologies to remotely monitor patients suffering chronic diseases may enable preemptive treatment of worsening health conditions before a significant deterioration in the subject's health status occurs, requiring hospital admission. OBJECTIVE: The objective of this study was to develop and validate a classification algorithm for the early identification of patients, with a background of chronic obstructive pulmonary disease (COPD), who appear to be at high risk of an imminent exacerbation event. The algorithm attempts to predict the patient's condition one day in advance, based on a comparison of their current physiological measurements against the distribution of their measurements over the previous month. METHOD: The proposed algorithm, which uses a classification and regression tree (CART), has been validated using telehealth measurement data recorded from patients with moderate/severe COPD living at home. The data were collected from February 2007 to January 2008, using a telehealth home monitoring unit. RESULTS: The CART algorithm can classify home telehealth measurement data into either a 'low risk' or 'high risk' category with 71.8% accuracy, 80.4% specificity and 61.1% sensitivity. The algorithm was able to detect a 'high risk' condition one day prior to patients actually being observed as having a worsening in their COPD condition, as defined by symptom and medication records. CONCLUSION: The CART analyses have shown that features extracted from three types of physiological measurements; forced expiratory volume in 1s (FEV1), arterial oxygen saturation (SPO2) and weight have the most predictive power in stratifying the patients condition. This CART algorithm for early detection could trigger the initiation of timely treatment, thereby potentially reducing exacerbation severity and recovery time and improving the patient's health. This study highlights the potential usefulness of automated analysis of home telehealth data in the early detection of exacerbation events among COPD patients.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Telemedicina/métodos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Peso Corporal , Árvores de Decisões , Erradicação de Doenças , Diagnóstico Precoce , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Oxigênio/sangue , Valor Preditivo dos Testes , Prognóstico , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Consulta Remota , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS