Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(3): 499-510, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38168895

RESUMO

INTRODUCTION AND OBJECTIVES: Advanced chronic kidney disease (A-CKD) combined with atrial fibrillation increases the risk of both thrombogenic and bleeding events. Left atrial appendage occlusion (LAAO) may be an alternative to oral anticoagulation to prevent thromboembolic events. We aimed to evaluate the outcomes of LAAO in patients with A-CKD. METHODS: Comparison at long-term follow-up of patients diagnosed with and without A-CKD (eGFR<30 mL/min/1.73 m2 ) who underwent LAAO between 2009 and May 2022. RESULTS: Five hundred seventy-three patients were included. Eighty-one (14%) were diagnosed with A-CKD. There were no differences in sex, age, and cardiovascular risk factors, except for diabetes which was more frequent in patients with A-CKD. The control group had higher rates of stroke, both ischemic and hemorrhagic. There were no differences in the CHA2 DS2 -VASc score, although A-CKD patients had a higher bleeding risk according to the HASBLED scale. Global procedural success was 99.1%. At follow-up, there were no differences in stroke rate: at 1-year (HR: 1.22, IC-95%: 0.14-10.42, p = 0.861); at 5-years (HR: 0.60, IC-95%: 0.08-4.58, p = 0.594). Although bleeding events were higher in the A-CKD group, no differences were found in major bleeding (defined BARC ≥ 3) at 1-year (HR: 1.34, IC-95%: 0.63-2.88, p = 0.464) or at 5-years follow-up (HR: 1.30, IC-95%: 0.69-2.48, p = 0.434). Mortality rate at 5 years was higher in the A-CKD patients (HR: 1.84, IC-95%: 1.18-2.87, p = 0.012). CONCLUSIONS: LAAO is an effective and safe treatment in A-CKD patients to prevent ischemic events and bleeding. This strategy could be an alternative to oral anticoagulation in this high-risk group of patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Seguimentos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Anticoagulantes/efeitos adversos
2.
J Interv Cardiol ; 29(4): 382-92, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27242018

RESUMO

Paravalvular leak (PVL) is an uncommon yet serious complication associated with the implantation of mechanical or bioprosthetic surgical valves and more recently recognized with transcatheter aortic valves implantation (TAVI). A significant number of patients will present with symptoms of congestive heart failure or haemolytic anaemia due to PVL and need further surgical or percutaneous treatment. Until recently, surgery has been the only available therapy for the treatment of clinically significant PVLs despite the significant morbidity and mortality associated with re-operation. Percutaneous treatment of PVLs has emerged as a safe and less invasive alternative, with low complication rates and high technical and clinical success rates. However, it is a complex procedure, which needs to be performed by an experienced team of interventional cardiologists and echocardiographers. This review discusses the current understanding of PVLs, including the utility of imaging techniques in PVL diagnosis and treatment, and the principles, outcomes and complications of transcatheter therapy of PVLs.


Assuntos
Fístula Anastomótica/cirurgia , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Reoperação/métodos , Técnicas de Fechamento de Ferimentos , Fístula Anastomótica/diagnóstico , Fístula Anastomótica/etiologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Falha de Prótese
3.
Circ J ; 80(3): 738-44, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26823141

RESUMO

BACKGROUND: Mitral paravalvular leak (PVL) is a potential complication of surgical valve replacement procedures. Real-time 3D transesophageal echocardiography (RT-3DTEE) has emerged as an efficient tool for providing essential information about the anatomy of mitral PVLs compared with 2DTEE findings. The purpose of this study was to evaluate the utility of RT-3DTEE in the assessment of mitral PVLs. METHODS AND RESULTS: The 3D characteristics of PVLs were recorded and compared with 2D findings. We included 34 consecutive patients with clinical suspicion of mitral PVL in the study. Mitral PVLs were detected in 26 patients (76%); 26 PVLs were identified by 2DTEE and 37 by RT-3DTEE. Moderate or severe mitral regurgitation was present in 23 patients (88%). The most common PVL locations were the septal and posterior regions. The median PVL size measured by RT-3DTEE was 7 mm long×4 mm wide. The median vena contracta of defect measured by 2DTEE and RT-3DTEE was 5 mm and 4 mm, respectively. The median effective regurgitant orifice area of defect measured by RT-3DTEE was 0.36 cm(2). The defect types were "oval" (54%), "round" (35%), "crescentic" (8%) and highly irregular (3%). CONCLUSIONS: Compared with 2DTEE, RT-3DTEE provided detailed descriptions of the number, location, size and morphology of PVLs, which is essential for planning and guiding the potential corrective techniques. (Circ J 2016; 80: 738-744).


Assuntos
Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia
4.
Catheter Cardiovasc Interv ; 83(4): 642-6, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24214580

RESUMO

OBJECTIVE: To evaluate the impact of learning on outcome with use of two different left atrial appendage (LAA) occlusion devices. BACKGROUND: Two self-expanding devices, the Watchman and the Amplatzer Cardiac Plug (ACP), have been used for LAA occlusion in the last few years. It has been demonstrated that complications associated with implantation decrease in frequency with operator experience. However, the role of operator experience has not been compared across the two device types. METHODS: The study comprises 31 consecutive patients who underwent LAA occlusion. We compare the first 10 patients in whom an ACP was implanted with the subsequent eleven patients who underwent ACP implantation and with 10 cases where a Watcthman device was implanted. The composite safety end point comprised procedure-related events and excessive bleeding events. We also performed 3 months echocardiographic and clinical follow-up. RESULTS: There were not significant differences in the basal clinical and echocardiographical characteristics across the three groups. Cardiac complications only occurred in the ACP initial experience group (9% vs. 0% vs. 0% P = 0.04). Echocardiographic and clinical follow-up at 3 months was completed in all patients. No significant residual leak was detected. One patient in the ACP initial experience group developed a thrombus on the device. One patient in ACP late experience presented an ischemic stroke. CONCLUSIONS: Complications associated with LAA occlusion cluster early in the peri-procedural period and significantly decrease in frequency with operator experience. Initial experience gained with one of device may improve outcome with use of alternative LAA occlusion devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Competência Clínica , Curva de Aprendizado , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
5.
J Clin Med ; 12(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959194

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is a safe and effective alternative to oral anticoagulation for thromboprophylaxis in patients with nonvalvular atrial fibrillation. Technological development in devices and imaging techniques, as well as accumulated experience, have increased procedural success rates and decreased complications. Same-day discharge protocols have been proposed in the field of structural heart disease, but this approach has not been studied in detail for the LAAO procedure. AIM: The aim of this study is to assess the safety and efficacy of an outpatient program for LAAO when compared to the conventional treatment approach. METHODS: We present a retrospective, non-randomized single-center study of 262 consecutive patients undergoing LAAO. Patients were divided into two groups, the first (n = 131) followed a conventional protocol (CP), and the second (n = 131) an outpatient protocol (OP). The primary composite endpoint comprised MACCE (death, stroke, and bleeding), cardiac tamponade, vascular complication, or attendance in the emergency department after hospital discharge at 30 days. RESULTS: The overall success rate was 99.6%, with a periprocedural complication rate of 2.29%. With regards to the CP versus OP group, there were no differences between incidences of the primary composite endpoint (6.1% PC vs. 3.0% PA, p = 0.24), or after an analysis, with propensity score matching. No differences were observed in the individual endpoints. There was a decrease in hospital length of stay in the same-day discharge group (p < 0.01). CONCLUSIONS: A same-day discharge LAAO program is safe, effective, and feasible when compared to the conventional strategy. Moreover, it reduces hospital length of stay, which might have clinical and economic benefits.

6.
J Clin Med ; 11(16)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-36013075

RESUMO

BACKGROUND: Paravalvular leak occurs in 5-17% of patients following surgical valve replacement, more often in mitral position. The prognosis without treatment is poor. Percutaneous device closure represents an alternative to repeat surgery. The objective of this work is to evaluate the medium and long-term results in the percutaneous closure of PVL in mitral prosthesis. METHODS: This observational study is based on a retrospective registry including consecutive mitral PVL cases undergoing percutaneous closure at a single tertiary-care center from April 2010 to December 2020. The safety and efficacy results of the procedure, at 90 days and in the long term, were analyzed. Also, predictors of procedure failure and long-term events were identified. RESULTS: A total of 128 consecutive mitral paravalvular leak closure procedures were included. Technical success was achieved in 115 (89.8%) procedures. The presence of multiple PVLs was the sole factor that independently predicted procedural failure. Median follow-up of our sample was 41.8 months (mean 47.7 ± 35.7 months). Underlying hemolytic anemia as the indication for PVL closure, a recent admission for decompensated HF, and lack of improvement in functional class emerged as consistent predictors of MACE and death during long-term follow-up, while lack of procedural success during the first PVL procedure and chronic kidney disease were also associated with MACE during follow-up. CONCLUSIONS: Percutaneous mitral PVL closure displayed high technical and procedural success rates, with an acceptable safety profile, in a high-risk population. Percutaneous mitral PVL closure achieved an improvement in short- and long-term functional class and a reduction of hemolysis in the vast majority of patients. In addition, long-term survival in our study was good, in particular for patients undergoing successful PVL closure procedures.

7.
Rev Port Cardiol ; 36(3): 219.e1-219.e4, 2017 Mar.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28245948

RESUMO

We present the case of a patient with a high-output fistula between the right superficial femoral artery and femoral vein after left atrial appendage closure successfully treated with a PK-Papyrus covered coronary stent using a 6F guiding catheter. To the best of our knowledge this is the first time a PK-Papyrus coronary stent has been used in this setting.


Assuntos
Fístula Arteriovenosa/cirurgia , Artéria Femoral/cirurgia , Veia Femoral/cirurgia , Complicações Pós-Operatórias/cirurgia , Stents , Idoso de 80 Anos ou mais , Fístula Arteriovenosa/etiologia , Feminino , Humanos , Doença Iatrogênica , Complicações Pós-Operatórias/etiologia , Procedimentos Cirúrgicos Vasculares/métodos
10.
Turk Kardiyol Dern Ars ; 44(8): 697-699, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28045418

RESUMO

A 56-year-old female patient was transferred due to the presence of a left supraclavicular pulsatile mass. Further work-up was performed to confirm diagnosis. Angiography and computed tomography were also performed. The anatomy of the thoracic aorta suggested an unknown and untreated aortic coarctation. A second aortic narrowing was identified at the aortic arch, a result of elongation of the aorta. Endovascular approach was not possible, due to complexity of the aortic anatomy, and tortuosity. Open surgical repair was successfully performed. A primary coarctation-related isthmus aneurysm is an exceptional finding in adults, and is a life-threatening condition when diagnosis is delayed. Management and treatment are controversial and challenging.


Assuntos
Falso Aneurisma/diagnóstico , Aorta Torácica , Coartação Aórtica/diagnóstico , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Angiografia Coronária , Diagnóstico Diferencial , Procedimentos Endovasculares , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
14.
Rev Port Cardiol ; 34(2): 141.e1-3, 2015 Feb.
Artigo em Inglês, Português | MEDLINE | ID: mdl-25660462

RESUMO

A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient.


Assuntos
Doenças das Valvas Cardíacas/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Valva Mitral/patologia , Trombose/etiologia , Idoso , Feminino , Fibrose/etiologia , Humanos , Falha de Prótese
15.
Rev. chil. cardiol ; 39(2): 154-158, ago. 2020. graf
Artigo em Espanhol | LILACS | ID: biblio-1138528

RESUMO

Abstract Atrial fibrillation (AF) is an increasing health care problem associated with thromboembolic risk about 5% per year, with high mortality and morbidity when associated to stroke. Oral anticoagulants (OAC) are the treatment of choice for preventing ischemic stroke in patients with nonvalvular atrial fibrillation (NVAF). However, these drugs are associated with an increased risk of serious complications such an intracranial hemorrhage (ICH). In this context percutaneous closure of the left atrial appendage (LAA) is an effective therapeutic alternative to OACs, with an increasing success rate. Novel devices might allow or facilitate the procedure in some anatomically and technically complicated cases. Two patients with a complex morphology of the LAA, in which the LAmbre (Lifetech Scientific [Shenzhen] Co. Ltd.) device was implanted with good technical and clinical results are presented.


Assuntos
Humanos , Feminino , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Apêndice Atrial/diagnóstico por imagem , Dispositivo para Oclusão Septal , Fibrilação Atrial/diagnóstico por imagem , Angiografia , Ecocardiografia , Cateterismo Cardíaco/métodos , Acidente Vascular Cerebral/prevenção & controle
17.
Rev Esp Cardiol (Engl Ed) ; 67(8): 608-14, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25037539

RESUMO

INTRODUCTION AND OBJECTIVES: Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series of patients. The aim of this study was to analyze the feasibility and efficacy of paravalvular leak with this device. METHODS: The immediate and 90-day safety and efficacy of mitral and aortic paravalvular leak closures performed with this device at our hospital were analyzed. RESULTS: Percutaneous repair of 34 paravalvular leaks (27 mitral, 7 aortic) was attempted in 33 patients. The device was successfully implanted in 93.9% (in 2 patients, a second planned procedure was needed), and successful closure (defined as regurgitation reduction ≥ 1 grade) was achieved in 90.9% of patients. Complications included emergency surgery due to disc interference (n=1) and blood transfusion (n=3). There were no reports of procedure-related death, myocardial infarction, or stroke. At 90 days, survival was 100%, and 90.3% of patients showed significant clinical improvement; 4 patients developed vascular complications (pseudoaneurysm). CONCLUSIONS: Mitral and aortic paravalvular leak closure with the Amplatzer Vascular Plug III is feasible and safe, with high clinical and echocardiographic success rates.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Dispositivo para Oclusão Septal , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Falha de Prótese , Reoperação , Resultado do Tratamento
20.
Can J Cardiol ; 29(11): 1531.e15-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24054923

RESUMO

Mechanical aortic valve prostheses are considered a limiting factor when contemplating percutaneous closure of mitral paravalvular leaks using a retrograde approach. However, transfemoral artery access and a retrograde approach have advantages over a trans-septal anterograde approach when the paravalvular defect is large with a significant gradient or when the defect is medial to the mitral valve. We describe a novel technique of mitral paravalvular leak closure in the presence of a mechanical aortic valve prosthesis, which we performed successfully in 3 patients. The technique uses a retrograde approach and arteriovenous wire loop.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Dispositivo para Oclusão Septal , Idoso , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA