1.
Catheter Cardiovasc Interv ; 94(1): 149-156, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30945420

RESUMO

OBJECTIVES: To assess feasibility, safety, angiographic, and clinical outcome of highly-calcific carotid stenosis (HCCS) endovascular management using CGuard™ dual-layer carotid stents. BACKGROUND: HCCS has been a challenge to carotid artery stenting (CAS) using conventional stents. CGuard combines a high-radial-force open-cell frame conformability with MicroNet sealing properties. METHODS: The PARADIGM study is prospectively assessing routine CGuard use in all-comer carotid revascularization patients; the focus of the present analysis is HCCS versus non-HCCS lesions. Angiographic HCCS (core laboratory evaluation) required calcific segment length to lesion length ≥2/3, minimal calcification thickness ≥3 mm, circularity (≥3 quadrants), and calcification severity grade ≥3 (carotid calcification severity scoring system [CCSS]; G0-G4). RESULTS: One hundred and one consecutive patients (51-86 years, 54.4% symptomatic; 106 lesions) received CAS (16 HCCS and 90 non-HCCS); eight others (two HCCS) were treated surgically. CCSS evaluation was reproducible, with weighted kappa (95% CI) of 0.73 (0.58-0.88) and 0.83 (0.71-0.94) for inter- and intra-observer reproducibility respectively. HCCS postdilatation pressures were higher than those in non-HCCS; 22 (20-24) versus 20 (18-24) atm, p = .028; median (Q1-Q3). Angiography-optimized HCCS-CAS was feasible and free of contrast extravasation or clinical complications. Overall residual diameter stenosis was single-digit but it was higher in HCCS; 9 (4-17) versus 3 (1-7) %, p = .002. At 30 days and 12 months HCCS in-stent velocities were normal and there were no adverse clinical events. CONCLUSION: CGuard HCCS endovascular management was feasible and safe. A novel algorithm to grade carotid artery calcification severity was reproducible and applicable in clinical study setting. Larger HCCS series and longer-term follow-up are warranted.


Assuntos
Estenose das Carótidas/terapia , Procedimentos Endovasculares/instrumentação , Stents , Acidente Vascular Cerebral/prevenção & controle , Calcificação Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia , Doenças Assintomáticas , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/complicações , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA