Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-37982158

RESUMO

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
2.
Front Genet ; 15: 1392527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38836037

RESUMO

Background: Variants in the MYBPC3 gene are a frequent cause of hypertrophic cardiomyopathy (HCM) but display a large phenotypic heterogeneity. Founder mutations are often believed to be more benign as they prevailed despite potential negative selection pressure. We detected a pathogenic variant in MYBPC3 (del exon 23-26) in several probands. We aimed to assess the presence of a common haplotype and to describe the cardiac characteristics, disease severity and long-term outcome of mutation carriers. Methods: Probands with HCM caused by a pathogenic deletion of exon 23-26 of MYBPC3 were identified through genetic screening using a gene panel encompassing 59 genes associated with cardiomyopathies in a single genetic center in Belgium. Cascade screening of first-degree relatives was performed, and genotype positive relatives were further phenotyped. Clinical characteristics were collected from probands and relatives. Cardiac outcomes included death, heart transplantation, life-threatening arrhythmia, heart failure hospitalization or septal reduction therapy. Haplotype analysis, using microsatellite markers surrounding MYBPC3, was performed in all index patients to identify a common haplotype. The age of the founder variant was estimated based on the size of the shared haplotype using a linkage-disequilibrium based approach. Results: We identified 24 probands with HCM harbouring the MYBPC3 exon 23-26 deletion. Probands were on average 51 ± 16 years old at time of clinical HCM diagnosis and 62 ± 10 years old at time of genetic diagnosis. A common haplotype of 1.19 Mb was identified in all 24 probands, with 19 of the probands sharing a 13.8 Mb haplotype. The founder event was estimated to have happened five generations, or 175-200 years ago, around the year 1830 in central Flanders. Through cascade screening, 59 first-degree relatives were genetically tested, of whom 37 (62.7%) were genotype positive (G+) and 22 (37.3%) genotype negative (G-). They were on average 38 ± 19 years old at time of genetic testing. Subsequent clinical assessment revealed a HCM phenotype in 19 (51.4%) G+ relatives. Probands were older (63 ± 10 vs. 42 ± 21 years; p < 0.001) and had more severe phenotypes than G+ family members, presenting with more symptoms (50% vs. 13.5%; p = 0.002), arrhythmia (41.7% vs. 12.9%, p = 0.014), more overt hypertrophy and left ventricular outflow tract obstruction (43.5% vs. 3.0%; p < 0.001). Male G+ relatives more often had a HCM phenotype (78.6% vs. 34.8%; p = 0.010) and were more severely affected than females. At the age of 50, a penetrance of 78.6% was observed, defined as the presence of HCM in 11 of 14 G+ relatives with age ≥50 years. Overall, 20.3% of all variant carriers developed one of the predefined cardiac outcomes after a median follow-up of 5.5 years with an average age of 50 (±21) years. Conclusion: A Belgian founder variant, an exon 23-26 deletion in MYBPC3, was identified in 24 probands and 37 family members. The variant is characterized by a high penetrance of 78.6% at the age of 50 years but has variable phenotypic expression. Adverse outcomes were observed in 20.3% of patients during follow-up.

3.
Acta Cardiol ; 79(1): 46-57, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38450496

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 device has recently shown significant clinical benefits, compared to surgical aortic valve replacement (SAVR), in patients at low risk for surgical mortality (PARTNER 3 trial, NCT02675114). Currently in Belgium, TAVI use is restricted to high-risk or inoperable patients with severe symptomatic aortic stenosis (sSAS). This cost-utility analysis aimed to assess whether TAVI with SAPIEN 3 could lead to potential cost-savings compared with SAVR, in the low-risk sSAS population in Belgium. METHODS: A previously published, two-stage, Markov-based cost-utility model was used. Clinical outcomes were captured using data from PARTNER 3 and the model was adapted for the Belgian context using cost data from the perspective of the Belgian National Healthcare System, indexed to 2022. A lifetime horizon was chosen. The model outputs included changes in direct healthcare costs, survival and health-related quality of life using TAVI versus SAVR. RESULTS: TAVI with SAPIEN 3 provides meaningful clinical and cost benefits over SAVR, in terms of an increase in quality-adjusted life years (QALYs) of 0.94 and cost-saving of €3 013 per patient. While initial procedure costs were higher for TAVI compared with SAVR, costs related to rehabilitation, disabling stroke, treated atrial fibrillation, and rehospitalization were lower. The cost-effectiveness of TAVI over SAVR remained robust in sensitivity analyses. CONCLUSION: TAVI with SAPIEN 3 may offer a meaningful alternative intervention to SAVR in Belgian low-risk patients with sSAS, showing both clinical benefits and cost savings associated with post-procedure patient management.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bélgica/epidemiologia , Constrição Patológica , Análise de Custo-Efetividade , Qualidade de Vida , Ensaios Clínicos como Assunto
4.
Interv Cardiol ; 15: e09, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32714445

RESUMO

Acute coronary artery obstruction is a rare but life-threatening complication of transcatheter aortic valve implantation. In patients at risk of coronary artery obstruction, pre-emptive coronary artery protection with a coronary wire, balloon or stent provides a bailout treatment option. The authors describe the steps involved in performing chimney stenting and summarise the short- and long-term outcome data associated with this technique.

5.
Am J Phys Med Rehabil ; 96(2): 84-92, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27175562

RESUMO

OBJECTIVE: The purpose of this work was to test the hypothesis that cardiopulmonary exercise tolerance is better preserved early after endoscopic atraumatic coronary artery bypass graft (endo-ACAB) surgery versus coronary artery bypass graft (CABG) surgery. DESIGN: Twenty endo-ACAB surgery patients, 20 CABG surgery patients, and 15 healthy subjects executed a maximal cardiopulmonary exercise test, with assessment and comparison of cycling power output, O2 uptake, CO2 output, respiratory gas exchange ratio, end-tidal O2 and CO2 pressures, equivalents for O2 uptake and CO2 output, heart rate, O2 pulse, expiratory volume, tidal volume, respiratory rate, at peak exercise and ventilatory threshold. In patients, forced expiratory volume and forced vital capacity were measured. RESULTS: Oxygen uptake, CO2 output, expiratory and tidal volume, equivalents for O2 uptake and CO2 output, end-tidal O2 and CO2 pressures at peak exercise (matched peak respiratory gas exchange ratio between patient groups), and ventilatory threshold were significantly worse in patients versus healthy controls (P < 0.05; observed power, >0.80). All these parameters, and lung function, were, however, comparable between CABG and endo-ACAB surgery patients (P > 0.10). CONCLUSIONS: Exercise tolerance and ventilatory function during exercise seems, in contrast to expectation, equally compromised early after endo-ACAB surgery as opposed to after CABG surgery. These data may signify the need for exercise-based rehabilitation intervention early after endo-ACAB surgery.


Assuntos
Ponte de Artéria Coronária/reabilitação , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Endoscopia , Tolerância ao Exercício/fisiologia , Idoso , Estudos de Casos e Controles , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/reabilitação , Estudos Transversais , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA