Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biomed Eng Online ; 23(1): 2, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167089

RESUMO

BACKGROUND: Balance parameters derived from wearable sensor measurements during postural sway have been shown to be sensitive to experimental variables such as test duration, sensor number, and sensor location that influence the magnitude and frequency-related properties of measured center-of-mass (COM) and center-of-pressure (COP) excursions. In this study, we investigated the effects of test duration, the number of sensors, and sensor location on the reliability of standing balance parameters derived using body-mounted accelerometers. METHODS: Twelve volunteers without any prior history of balance disorders were enrolled in the study. They were asked to perform two 2-min quiet standing tests with two different testing conditions (eyes open and eyes closed). Five inertial measurement units (IMUs) were employed to capture postural sway data from each participant. IMUs were attached to the participants' right legs, the second sacral vertebra, sternum, and the left mastoid processes. Balance parameters of interest were calculated for the single head, sternum, and sacrum accelerometers, as well as, a three-sensor combination (leg, sacrum, and sternum). Accelerometer data were used to estimate COP-based and COM-based balance parameters during quiet standing. To examine the effect of test duration and sensor location, each 120-s recording from different sensor locations was segmented into 20-, 30-, 40-, 50-, 60-, 70-, 80-, 90-, 100-, and 110-s intervals. For each of these time intervals, time- and frequency-domain balance parameters were calculated for all sensor locations. RESULTS: Most COM-based and COP-based balance parameters could be derived reliably for clinical applications (Intraclass-Correlation Coefficient, ICC ≥ 0.90) with a minimum test duration of 70 and 110 s, respectively. The exceptions were COP-based parameters obtained using a sacrum-mounted sensor, especially in the eyes-closed condition, which could not be reliably used for clinical applications even with a 120-s test duration. CONCLUSIONS: Most standing balance parameters can be reliably measured using a single head- or sternum-mounted sensor within a 120-s test duration. For other sensor locations, the minimum test duration may be longer and may depend on the specific test conditions.


Assuntos
Perna (Membro) , Equilíbrio Postural , Humanos , Reprodutibilidade dos Testes , Posição Ortostática , Acelerometria
2.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991855

RESUMO

The smooth movement of hand/surgical instruments is considered an indicator of skilled, coordinated surgical performance. Jerky surgical instrument movements or hand tremors can cause unwanted damages to the surgical site. Different methods have been used in previous studies for assessing motion smoothness, causing conflicting results regarding the comparison among surgical skill levels. We recruited four attending surgeons, five surgical residents, and nine novices. The participants conducted three simulated laparoscopic tasks, including peg transfer, bimanual peg transfer, and rubber band translocation. Tooltip motion smoothness was computed using the mean tooltip motion jerk, logarithmic dimensionless tooltip motion jerk, and 95% tooltip motion frequency (originally proposed in this study) to evaluate their capability of surgical skill level differentiation. The results revealed that logarithmic dimensionless motion jerk and 95% motion frequency were capable of distinguishing skill levels, indicated by smoother tooltip movements observed in high compared to low skill levels. Contrarily, mean motion jerk was not able to distinguish the skill levels. Additionally, 95% motion frequency was less affected by the measurement noise since it did not require the calculation of motion jerk, and 95% motion frequency and logarithmic dimensionless motion jerk yielded a better motion smoothness assessment outcome in distinguishing skill levels than mean motion jerk.


Assuntos
Laparoscopia , Cirurgiões , Humanos , Movimento (Física) , Movimento , Instrumentos Cirúrgicos , Mãos
3.
Sensors (Basel) ; 23(24)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38139516

RESUMO

Muscle fatigue has proven to be a main factor in developing work-related musculoskeletal disorders. Taking small breaks or performing stretching routines during a work shift might reduce workers' fatigue. Therefore, our objective was to explore how breaks and/or a stretching routine during a work shift could impact muscle fatigue and body kinematics that might subsequently impact the risk of work-related musculoskeletal disorder (WMSD) risk during material handling jobs. We investigated muscle fatigue during a repetitive task performed without breaks, with breaks, and with a stretching routine during breaks. Muscle fatigue was detected using muscle activity (electromyography) and a validated kinematic score measured by wearable sensors. We observed a significant reduction in muscle fatigue between the different work-rest schedules (p < 0.01). Also, no significant difference was observed between the productivity of the three schedules. Based on these objective kinematic assessments, we concluded that taking small breaks during a work shift can significantly reduce muscle fatigue and potentially reduce its consequent risk of work-related musculoskeletal disorders without negatively affecting productivity.


Assuntos
Fadiga Muscular , Doenças Musculoesqueléticas , Humanos , Fadiga Muscular/fisiologia , Eletromiografia , Descanso
4.
Sensors (Basel) ; 23(11)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37299726

RESUMO

Surface electromyography (sEMG) is generally used to measure muscles' activity. The sEMG signal can be affected using several factors and vary among individuals and even measurement trials. Thus, to consistently evaluate data among individuals and trials, the maximum voluntary contraction (MVC) value is usually calculated and used to normalize sEMG signals. However, the sEMG amplitude collected from low back muscles can be frequently larger than that found when conventional MVC measurement procedures are used. To address this limitation, in this study, we proposed a new dynamic MVC measurement procedure for low back muscles. Inspired by weightlifting, we designed a detailed dynamic MVC procedure, and then collected data from 10 able-bodied participants and compared their performances using several conventional MVC procedures by normalizing the sEMG amplitude for the same test. The sEMG amplitude normalized by our dynamic MVC procedure showed a much lower value than those obtained using other procedures (Wilcoxon signed-rank test, with p < 0.05), indicating that the sEMG collected during dynamic MVC procedure had a larger amplitude than those of conventional MVC procedures. Therefore, our proposed dynamic MVC obtained sEMG amplitudes closer to its physiological maximum value and is thus more capable of normalizing the sEMG amplitude for low back muscles.


Assuntos
Músculos do Dorso , Humanos , Eletromiografia/métodos , Exercício Físico , Músculo Esquelético/fisiologia , Contração Muscular/fisiologia
5.
Sensors (Basel) ; 23(21)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37960580

RESUMO

Maintaining a stable upright posture is essential for performing activities of daily living, and impaired standing balance may impact an individual's quality of life. Therefore, accurate and sensitive methods for assessing static balance are crucial for identifying balance impairments, understanding the underlying mechanisms of the balance deficiencies, and developing targeted interventions to improve standing balance and prevent falls. This review paper first explores the methods to quantify standing balance. Then, it reviews traditional posturography and recent advancements in using wearable inertial measurement units (IMUs) to assess static balance in two populations: older adults and those with incomplete spinal cord injury (iSCI). The inclusion of these two groups is supported by their large representation among individuals with balance impairments. Also, each group exhibits distinct aspects in balance assessment due to diverse underlying causes associated with aging and neurological impairment. Given the high vulnerability of both demographics to balance impairments and falls, the significance of targeted interventions to improve standing balance and mitigate fall risk becomes apparent. Overall, this review highlights the importance of static balance assessment and the potential of emerging methods and technologies to improve our understanding of postural control in different populations.


Assuntos
Atividades Cotidianas , Traumatismos da Medula Espinal , Humanos , Idoso , Qualidade de Vida , Modalidades de Fisioterapia , Envelhecimento , Equilíbrio Postural
6.
Respir Res ; 23(1): 333, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36482438

RESUMO

BACKGROUND: The nasal cannula is considered a trusted and effective means of administering low-flow oxygen and is widely used for neonates and infants requiring oxygen therapy, despite an understanding that oxygen concentrations delivered to patients are variable. METHODS: In the present study, realistic nasal airway replicas derived from medical scans of children less than 3 months old were used to measure the fraction of oxygen inhaled (FiO2) through nasal cannulas during low-flow oxygen delivery. Parameters influencing variability in FiO2 were evaluated, as was the hypothesis that measured FiO2 values could be predicted using a simple, flow-weighted calculation that assumes ideal mixing of oxygen with entrained room air. Tidal breathing through neonatal and infant nasal airway replicas was controlled using a lung simulator. Parameters for nasal cannula oxygen flow rate, nasal airway geometry, tidal volume, respiratory rate, inhalation/exhalation, or I:E ratio (ti/te), breath waveform, and cannula prong insertion position were varied to determine their effect on measured FiO2. In total, FiO2 was measured for 384 different parameter combinations, with each combination repeated in triplicate. Analysis of variance (ANOVA) was used to assess the influence of parameters on measured FiO2. RESULTS: Measured FiO2 was not appreciably affected by the breath waveform shape, the replica geometry, or the cannula position but was significantly influenced by the tidal volume, the inhalation time, and the nasal cannula flow rate. CONCLUSIONS: The flow-weighted calculation overpredicted FiO2 for measured values above 60%, but an empirical correction to the calculation provided good agreement with measured FiO2 across the full range of experimental data.


Assuntos
Cânula , Oxigênio , Criança , Recém-Nascido , Humanos , Lactente
7.
Gerontology ; 68(11): 1233-1245, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35093943

RESUMO

INTRODUCTION: Observational tests, e.g., the Berg Balance Scale (BBS) are widely used for balance evaluation in the elderly fallers. However, they do not allow objective outcome evaluation of rehabilitative interventions. This study aimed to investigate, in a clinical setting, the use of inertial measurement units (IMUs) integrated into the BBS test for objective outcome evaluation of balance rehabilitation in elderly fallers compared to conventional BBS scores. METHODS: Thirty-six elderly fallers were recruited from the in-patient population of a geriatrics Clinic. Participants performed the BBS test while wearing 3 IMUs placed on the sternum, sacrum, and tibia of the dominant leg following admission to the clinic. Subsequently, they completed a rehabilitation program for 2-4 weeks. They performed a similar test before their discharge. The physical therapist recorded the BBS scores at both sessions, and the sensor data of the 2-min quiet standing task (BBS task 2) were extracted for objective balance evaluation. Moreover, eleven young adults were recruited to perform a 2-min quiet standing test while wearing the same IMUs. Center-of-pressure (COP) and segmental center-of-mass (COM) accelerations were calculated to estimate time-domain, frequency-domain, and intersegment coordination biomarkers of balance. RESULTS: COP time- and frequency-domain measures, COM acceleration time-domain measures, and intersegment coordination measures could identify age-related changes in balance of seniors compared to young adults (p < 0.05). Moreover, balance biomarkers of senior adults exhibited a reduced sway acceleration and jerkiness in the medial-lateral direction post-rehabilitation (p < 0.05). Although the total BBS scores increased post-rehabilitation, sway displacement and velocity did not significantly improve. We observed a significant association between pelvis-leg coordination at high sway oscillations and the total BBS scores pre- and post-rehabilitation. CONCLUSION: IMUs enable not only the characterization of underlying causes of impaired balance but also the identification of improved and yet impaired aspects of balance post-rehabilitation. Hence, IMUs allow us to characterize risk factors post-rehabilitation in elderly fallers, whereas the BBS scores only show changes in overall balance. It is crucial to objectively evaluate the effectiveness of such interventions to reduce future falls and their adverse consequences. Therefore, instrumented balance assessment is recommended since it can provide quantitative and objective measures for clinical outcome evaluations.


Assuntos
Aceleração , Equilíbrio Postural , Humanos , Idoso , Fatores de Risco , Alta do Paciente
8.
Sensors (Basel) ; 23(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36616932

RESUMO

Hockey skating objective assessment can help coaches detect players' performance drop early and avoid fatigue-induced injuries. This study aimed to calculate and experimentally validate the 3D angles of lower limb joints of hockey skaters obtained by inertial measurement units and explore the effectiveness of the on-ice distinctive features measured using these wearable sensors in differentiating low- and high-calibre skaters. Twelve able-bodied individuals, six high-calibre and six low-calibre skaters, were recruited to skate forward on a synthetic ice surface. Five IMUs were placed on their dominant leg and pelvis. The 3D lower-limb joint angles were obtained by IMUs and experimentally validated against those obtained by a motion capture system with a maximum root mean square error of 5 deg. Additionally, among twelve joint angle-based distinctive features identified in other on-ice studies, only three were significantly different (p-value < 0.05) between high- and low-calibre skaters in this synthetic ice experiment. This study thus indicated that skating on synthetic ice alters the skating patterns such that the on-ice distinctive features can no longer differentiate between low- and high-calibre skating joint angles. This wearable technology has the potential to help skating coaches keep track of the players' progress by assessing the skaters' performance, wheresoever.


Assuntos
Hóquei , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Gelo , Hóquei/lesões , Extremidade Inferior
9.
Spinal Cord ; 59(6): 675-683, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33024297

RESUMO

STUDY DESIGN: Quantitative cross-sectional study. OBJECTIVES: Evaluate the test-retest reliability and the construct validity of inertial measurement units (IMU) to characterize spatiotemporal gait parameters in individuals with SCI. SETTING: Two SCI rehabilitation centers in Canada. METHODS: Eighteen individuals with SCI participated in two evaluation sessions spaced 2 weeks apart. Fifteen able-bodied individuals were also recruited. Participants walked 20 m overground under five conditions that challenged balance to varying degrees. Five IMU were attached to the lower-extremities and the sacrum to collect the mean and the coefficient of variation of five gait parameters (gait cycle time, double-support percentage, cadence, stride length, stride velocity). Intra-class correlation coefficients (ICC) were used to evaluate the test-retest reliability. Linear mixed-effects models were used to compare the five walking conditions to evaluate known-group validity while Spearman's correlation coefficients were used to characterize the level of association between gait parameters and the Mini BESTest (MBT). RESULTS: Cadence was reliable across all walking conditions. Reliability was higher for the mean (ICC = 0.55-0.98) of the parameters compared to their coefficient of variation (ICC = 0.16-0.97). Cadence collected with IMU had construct validity as their values differed across walking conditions and groups of participants. The coefficient of variation was generally better than the mean to show differences across the five walking conditions. The MBT was moderately to strongly associated with mean cadence (ρ ≥ 0.498) and its coefficient of variation (ρ ≤ -0.49) during most walking conditions. CONCLUSIONS: IMU provide reliable and valid measurements of gait parameters in ambulatory individuals with SCI.


Assuntos
Traumatismos da Medula Espinal , Dispositivos Eletrônicos Vestíveis , Estudos Transversais , Marcha , Humanos , Reprodutibilidade dos Testes , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/diagnóstico , Caminhada
10.
J Shoulder Elbow Surg ; 30(8): e493-e502, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33246080

RESUMO

BACKGROUND: Because nerve injury of muscles around the shoulder can be easily disguised by "trick movements" of the trunk, shoulder dysfunction following brachial plexus injury is difficult to quantify with conventional clinical tools. Thus, to evaluate brachial plexus injury and quantify its biomechanical consequences, we used inertial measurement units, which offer the sensitivity required to measure the trunk's subtle movements. METHODS: We calculated 6 kinematic scores using inertial measurement units placed on the upper arms and the trunk during 9 functional tasks. We used both statistical and machine learning techniques to compare the bilateral asymmetry of the kinematic scores of 15 affected and 15 able-bodied individuals (controls). RESULTS: Asymmetry indexes from several kinematic scores of the upper arm and trunk showed a significant difference (P < .05) between the affected and control groups. A bagged ensemble of decision trees trained with trunk and upper arm kinematic scores correctly classified all controls. All but 2 patients were also correctly classified. Upper arm scores showed correlation coefficients ranging from 0.55-0.76 with conventional clinical scores. CONCLUSIONS: The proposed wearable technology is a sensitive and reliable tool for objective outcome evaluation of brachial plexus injury and its biomechanical consequences. It may be useful in clinical research and practice, especially in large cohorts with multiple follow-ups.


Assuntos
Neuropatias do Plexo Braquial , Plexo Braquial , Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Neuropatias do Plexo Braquial/diagnóstico , Humanos , Ombro
11.
J Neuroeng Rehabil ; 17(1): 141, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-33109209

RESUMO

BACKGROUND: Postural control is affected after incomplete spinal cord injury (iSCI) due to sensory and motor impairments. Any alteration in the availability of sensory information can challenge postural stability in this population and may lead to a variety of adaptive movement coordination patterns. Hence, identifying the underlying impairments and changes to movement coordination patterns is necessary for effective rehabilitation post-iSCI. This study aims to compare the postural control strategy between iSCI and able-bodied populations by quantifying the trunk-leg movement coordination under conditions that affects sensory information. METHODS: 13 individuals with iSCI and 14 aged-matched able-bodied individuals performed quiet standing on hard and foam surfaces with eyes open and closed. We used mean Magnitude-Squared Coherence between trunk-leg accelerations measured by accelerometers placed over the sacrum and tibia. RESULTS: We observed a similar ankle strategy at lower frequencies (f ≤ 1.0 Hz) between populations. However, we observed a decreased ability post-iSCI in adapting inter-segment coordination changing from ankle strategy to ankle-hip strategy at higher frequencies (f > 1.0 Hz). Moreover, utilizing the ankle-hip strategy at higher frequencies was challenged when somatosensory input was distorted, whereas depriving visual information did not affect balance strategy. CONCLUSION: Trunk-leg movement coordination assessment showed sensitivity, discriminatory ability, and excellent test-retest reliability to identify changes in balance control strategy post-iSCI and due to altered sensory inputs. Trunk-leg movement coordination assessment using wearable sensors can be used for objective outcome evaluation of rehabilitative interventions on postural control post-iSCI.


Assuntos
Equilíbrio Postural/fisiologia , Desempenho Psicomotor/fisiologia , Transtornos de Sensação/diagnóstico por imagem , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Movimento , Reprodutibilidade dos Testes , Transtornos de Sensação/diagnóstico , Transtornos de Sensação/etiologia , Traumatismos da Medula Espinal/complicações , Tronco
12.
Sensors (Basel) ; 20(12)2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32575452

RESUMO

Lower extremity kinematic alterations associated with sport-related knee injuries may contribute to an unsuccessful return to sport or early-onset post-traumatic osteoarthritis. Also, without access to sophisticated motion-capture systems, temporospatial monitoring of horizontal hop tests during clinical assessments is limited. By applying an alternative measurement system of two inertial measurement units (IMUs) per limb, we obtained and validated flying/landing times and hop distances of triple single-leg hop (TSLH) test against motion-capture cameras, assessed these temporospatial parameters amongst injured and uninjured groups, and investigated their association with the Knee Injury and Osteoarthritis Outcome Score (KOOS). Using kinematic features of IMU recordings, strap-down integration, and velocity correction techniques, temporospatial parameters were validated for 10 able-bodied participants and compared between 22 youth with sport-related knee injuries and 10 uninjured youth. With median (interquartile range) errors less than 10(16) ms for flying/landing times, and less than 4.4(5.6)% and 2.4(3.0)% of reference values for individual hops and total TSLH progression, differences between hopping biomechanics of study groups were highlighted. For injured participants, second flying time and all hop distances demonstrated moderate to strong correlations with KOOS Symptom and Function in Daily Living scores. Detailed temporospatial monitoring of hop tests is feasible using the proposed IMUs system.


Assuntos
Lesões do Ligamento Cruzado Anterior , Humulus , Traumatismos do Joelho , Dispositivos Eletrônicos Vestíveis , Adolescente , Feminino , Humanos , Perna (Membro) , Extremidade Inferior , Masculino , Qualidade de Vida
14.
J Biomech Eng ; 140(10)2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30029241

RESUMO

Kinetics assessment of the human head-arms-trunk (HAT) complex via a multisegment model is a useful tool for objective clinical evaluation of several pathological conditions. Inaccuracies in body segment parameters (BSPs) are a major source of uncertainty in the estimation of the joint moments associated with the multisegment HAT. Given the large intersubject variability, there is currently no comprehensive database for the estimation of BSPs for the HAT. We propose a nonlinear, multistep, optimization-based, noninvasive method for estimating individual-specific BSPs and calculating joint moments in a multisegment HAT model. Eleven nondisabled individuals participated in a trunk-bending experiment and their body motion was recorded using cameras and a force plate. A seven-segment model of the HAT was reconstructed for each participant. An initial guess of the BSPs was obtained by individual-specific scaling of the BSPs calculated from the male visible human (MVH) images. The intersegmental moments were calculated using both bottom-up and top-down inverse dynamics approaches. Our proposed method adjusted the scaled BSPs and center of pressure (COP) offsets to estimate optimal individual-specific BSPs that minimize the difference between the moments obtained by top-down and bottom-up inverse dynamics approaches. Our results indicate that the proposed method reduced the error in the net joint moment estimation (defined as the difference between the net joint moment calculated via bottom-up and top-down approaches) by 79.3% (median among participants). Our proposed method enables an optimized estimation of individual-specific BSPs and, consequently, a less erroneous assessment of the three-dimensional (3D) kinetics of a multisegment HAT model.


Assuntos
Antropometria , Tronco/anatomia & histologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Cinética , Masculino , Dinâmica não Linear
15.
J Biomech Eng ; 140(4)2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29238816

RESUMO

Methods that effectively assess and train dynamic seated balance are critical for enhancing functional independence and reducing risk of secondary health complications in the elderly and individuals with neuromuscular impairments. The objective of this research was to devise and validate a portable tool for assessing and training dynamic seated balance. An instrumented wobble board was designed and constructed that (1) elicits multidirectional perturbations in seated individuals, (2) quantifies seated balance proficiency, and (3) provides real-time, kinematics-based vibrotactile feedback. After performing a technical validation study to compare kinematic wobble board measurements against a gold-standard motion capture system, 15 nondisabled participants performed a dynamic sitting task using the wobble board. Our results demonstrate that the tilt angle measurements were highly accurate throughout the range of wobble board dynamics. Furthermore, the posturographic analyses for the dynamic sitting task revealed that the wobble board can effectively discriminate between the different conditions of perturbed balance, demonstrating its potential to serve as a clinical tool for the assessment and training of seated balance. Vibrotactile feedback decreased the variance of wobble board tilt, demonstrating its potential for use as a balance training tool. Unlike similar instrumented tools, the wobble board is portable, requires no laboratory equipment, and can be adjusted to meet the user's balance abilities. While future work is warranted, obtained findings will aid in effective translation of assessment and training techniques to a clinical setting, which has the potential to enhance the diagnosis and prognosis for individuals with seated balance impairments.


Assuntos
Desenho de Equipamento , Fenômenos Mecânicos , Equilíbrio Postural , Fenômenos Biomecânicos , Estudos de Viabilidade , Retroalimentação Sensorial , Feminino , Humanos , Masculino , Postura Sentada , Software , Adulto Jovem
16.
J Biomech Eng ; 138(7)2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27151927

RESUMO

A major challenge in the assessment of intersegmental spinal column angles during trunk motion is the inherent error in recording the movement of bony anatomical landmarks caused by soft tissue artifacts (STAs). This study aims to perform an uncertainty analysis and estimate the typical errors induced by STA into the intersegmental angles of a multisegment spinal column model during trunk bending in different directions by modeling the relative displacement between skin-mounted markers and actual bony landmarks during trunk bending. First, we modeled the maximum displacement of markers relative to the bony landmarks with a multivariate Gaussian distribution. In order to estimate the distribution parameters, we measured these relative displacements on five subjects at maximum trunk bending posture. Then, in order to model the error depending on trunk bending angle, we assumed that the error grows linearly as a function of the bending angle. Second, we applied our error model to the trunk motion measurement of 11 subjects to estimate the corrected trajectories of the bony landmarks and investigate the errors induced into the intersegmental angles of a multisegment spinal column model. For this purpose, the trunk was modeled as a seven-segment rigid-body system described using 23 reflective markers placed on various bony landmarks of the spinal column. Eleven seated subjects performed trunk bending in five directions and the three-dimensional (3D) intersegmental angles during trunk bending were calculated before and after error correction. While STA minimally affected the intersegmental angles in the sagittal plane (<16%), it considerably corrupted the intersegmental angles in the coronal (error ranged from 59% to 551%) and transverse (up to 161%) planes. Therefore, we recommend using the proposed error suppression technique for STA-induced error compensation as a tool to achieve more accurate spinal column kinematics measurements. Particularly, for intersegmental rotations in the coronal and transverse planes that have small range and are highly sensitive to measurement errors, the proposed technique makes the measurement more appropriate for use in clinical decision-making processes.


Assuntos
Pontos de Referência Anatômicos/anatomia & histologia , Artefatos , Amplitude de Movimento Articular/fisiologia , Coluna Vertebral/anatomia & histologia , Coluna Vertebral/fisiologia , Articulação Zigapofisária/fisiologia , Adulto , Feminino , Humanos , Aumento da Imagem , Imageamento Tridimensional , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Articulação Zigapofisária/anatomia & histologia
17.
J Biomech Eng ; 137(7)2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25901652

RESUMO

The ranges of angular motion measured using multisegmented spinal column models are typically small, meaning that minor experimental errors can potentially affect the reliability of these measures. This study aimed to investigate the sensitivity of the 3D intersegmental angles, measured using a multisegmented spinal column model, to errors due to marker misplacement. Eleven healthy subjects performed trunk bending in five directions. Six cameras recorded the trajectory of 22 markers, representing seven spinal column segments. Misplacement error for each marker was modeled as a Gaussian function with a standard deviation of 6 mm, and constrained to a maximum value of 12 mm in each coordinate across the skin. The sensitivity of 3D intersegmental angles to these marker misplacement errors, added to the measured data, was evaluated. The errors in sagittal plane motions resulting from marker misplacement were small (RMS error less than 3.2 deg and relative error in the angular range less than 15%) during the five trunk bending direction. The errors in the frontal and transverse plane motions, induced by marker misplacement, however, were large (RMS error up to 10.2 deg and relative error in the range up to 58%), especially during trunk bending in anterior, anterior-left, and anterior-right directions, and were often comparable in size to the intersubject variability for those motions. The induced errors in the frontal and transverse plane motions tended to be the greatest at the intersegmental levels in the lower lumbar region. These observations questioned reliability of angle measures in the frontal and transverse planes particularly in the lower lumbar region during trunk bending in anterior direction, and thus did not recommend interpreting these measures for clinical evaluation and decision-making.


Assuntos
Movimento , Projetos de Pesquisa , Coluna Vertebral/fisiologia , Adulto , Feminino , Marcadores Fiduciais , Humanos , Masculino , Amplitude de Movimento Articular
18.
J Biomech ; 167: 112077, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38599020

RESUMO

Low back pain is commonly reported in occupational settings due to factors such as heavy lifting and poor ergonomic practices, often resulting in significant healthcare expenses and lowered productivity. Assessment tools for human motion and ergonomic risk at the workplace are still limited. Therefore, this study aimed to assess lower back muscle and joint reaction forces in laboratory conditions using wearable inertial measurement units (IMUs) during weight lifting, a frequently high-risk workplace task. Ten able-bodied participants were instructed to lift a 28 lbs. box while surface electromyography sensors, IMUs, and a camera-based motion capture system recorded their muscle activity and body motion. The data recorded by IMUs and motion capture system were used to estimate lower back muscle and joint reaction forces via musculoskeletal modeling. Lower back muscle patterns matched well with electromyography recordings. The normalized mean absolute differences between muscle forces estimated based on measurements of IMUs and cameras were less than 25 %, and the statistical parametric mapping results indicated no significant difference between the forces estimated by both systems. However, abrupt changes in motion, such as lifting initiation, led to significant differences (p < 0.05) between the muscle forces. Furthermore, the maximum L5-S1 joint reaction force estimated using IMU data was significantly lower (p < 0.05) than those estimated by cameras during weight lifting and lowering. The study showed how kinematic errors from IMUs propagated through the musculoskeletal model and affected the estimations of muscle forces and joint reaction forces. Our findings showed the potential of IMUs for in-field ergonomic risk evaluations.


Assuntos
Músculos do Dorso , Dor Lombar , Dispositivos Eletrônicos Vestíveis , Humanos , Remoção , Músculos/fisiologia , Eletromiografia , Fenômenos Biomecânicos
19.
Respir Care ; 69(7): 782-789, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38503467

RESUMO

BACKGROUND: Patients with COPD and other lung diseases are treated with long-term oxygen therapy (LTOT). Portable oxygen sources are required to administer LTOT while maintaining patient autonomy. Existing portable oxygen equipment has limitations that can hinder patient mobility. A novel nasal interface is presented in this study, aiming to enhance breath detection and triggering efficiency of portable pulsed-flow oxygen devices, thereby improving patient mobility and independence. METHOD: To examine the effectiveness of the new interface, 8 respiratory therapists participated in trials using different oxygen sources (tank with oxygen-conserving device, SimplyGo Mini portable oxygen concentrator [POC], and OxyGo NEXT POC) and breathing types (nasal and oral) while using either the new nasal interface or a standard cannula. Each trial was video recorded so participant breaths could be retroactively matched with a pulse/no-pulse response, and triggering success rates were calculated by dividing the number of oxygen pulses by the number of breaths in each trial. After each trial, volunteers were asked to rate their perceived breathing resistance. RESULTS: Nasal breathing consistently resulted in higher triggering success rates compared to oral breathing for pulsed-flow oxygen devices. POCs exhibited higher triggering success rates than did the oxygen tanks with conserving device. However, there were no significant differences in triggering success rates between the two POC models. The new nasal interface demonstrated improved triggering success rates compared to the standard cannula. Whereas the new nasal interface was associated with a slight increase in perceived breathing resistance during nasal breathing trials, participants reported manageable resistance levels when using the interface. CONCLUSIONS: This study demonstrates that the new nasal interface can improve triggering success rates of pulsed-flow oxygen devices during both nasal and oral breathing scenarios. Further research involving patient trials is recommended to understand the clinical implications of improved pulse triggering.


Assuntos
Cânula , Desenho de Equipamento , Oxigenoterapia , Humanos , Oxigenoterapia/instrumentação , Oxigenoterapia/métodos , Masculino , Feminino , Respiração , Adulto , Doença Pulmonar Obstrutiva Crônica/terapia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Oxigênio/administração & dosagem , Gravação em Vídeo , Nariz
20.
Respir Care ; 69(4): 438-448, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38443141

RESUMO

BACKGROUND: The nasal cannula is widely regarded as a safe and effective means of administering low- and high-flow oxygen to patients irrespective of their age. However, variability in delivered oxygen concentration (FDO2 FDO2 ) via nasal cannula has the potential to pose health risks. The present study aimed to evaluate predictive equations for FDO2 over a large parameter space, including variation in breathing, oxygen flow, and upper-airway geometry representative of both young children and adults. METHODS: Realistic nasal airway geometries were previously collected from medical scans of adults, infants, and neonates. Nasal airway replicas based on these geometries were used to measure the FDO2 for low-flow oxygen delivery during simulated spontaneous breathing. The present study extends previously published data sets to include higher oxygen flows. The extended data sets included nasal cannula oxygen flows that ranged from 6 to 65 L/min for the adult replicas, and from 0.5 to 6 L/min for the infant replicas. For both age groups, FDO2 was measured over a range of breathing frequencies, inspiratory to expiratory time ratios, and tidal volumes. Measured FDO2 values were compared with values predicted by using a previously derived flow-weighted equation. RESULTS: For both age groups, FDO2 was observed to increase nonlinearly with the ratio between oxygen flow supplied to the nasal cannula and the average inhalation flow. The previously derived flow-weighted equation over-predicted FDO2 at higher oxygen flows. A new empirical equation, therefore, was proposed to predict FDO2 for either age group as a function of nasal cannula flow, tidal volume, and inspiratory time. Predicted FDO2 values matched measured values, with average relative errors of 2.4% for infants and 4.3% for adults. CONCLUSIONS: A new predictive equation for FDO2 was obtained that accurately matched measured data in both adult and infant airway replicas for low- and high-flow regimens.


Assuntos
Cânula , Respiração , Recém-Nascido , Adulto , Lactente , Criança , Humanos , Pré-Escolar , Nariz , Oxigênio , Intubação , Oxigenoterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA