Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Radiol ; 48(5): 632-637, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29541807

RESUMO

BACKGROUND: Scimitar syndrome is a rare combination of cardiopulmonary abnormalities found in 1-3 per 1000 live births. Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is only found in 1 in 250-400 congenital heart disease patients. OBJECTIVE: We aimed to investigate the incidence of left circumflex ALCAPA within our referral center's cohort of scimitar syndrome patients. MATERIALS AND METHODS: A review of medical records, cardiac imaging and operative notes from all patients diagnosed with scimitar syndrome at our center between 1992 and 2016 was undertaken and all imaging reviewed. RESULTS: Fifty-four patients with scimitar syndrome and imaging were identified. Of these, 3 patients (1 male and 2 female) with ALCAPA were identified, representing an incidence of 5.5% (95% confidence interval [CI] 0-11.67%). In all three cases, the anomalous coronary arising from the pulmonary artery was the left circumflex coronary artery (LCx) and the point of origin was close to the pulmonary arterial bifurcation. CONCLUSION: We hypothesize that the prevalence of LCx-ALCAPA, in the setting of scimitar syndrome, may be greater than previously thought. We suggest that any patient with scimitar syndrome, especially with evidence of ischaemia, should be investigated for ALCAPA. Given its noninvasive nature and simultaneous imaging of the lungs, we suggest that cardiovascular CT is the most appropriate first-line investigation for these patients.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/epidemiologia , Artéria Pulmonar/anormalidades , Síndrome de Cimitarra/diagnóstico por imagem , Síndrome de Cimitarra/epidemiologia , Cateterismo Cardíaco , Angiografia Coronária , Anomalias dos Vasos Coronários/cirurgia , Ecocardiografia , Eletrocardiografia , Evolução Fatal , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Síndrome de Cimitarra/cirurgia , Tomografia Computadorizada por Raios X
2.
Lancet ; 386(9998): 1066-73, 2015 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-26116485

RESUMO

BACKGROUND: Lung volume reduction surgery improves survival in selected patients with emphysema, and has generated interest in bronchoscopic approaches that might achieve the same effect with less morbidity and mortality. Previous trials with endobronchial valves have yielded modest group benefits because when collateral ventilation is present it prevents lobar atelectasis. METHODS: We did a single-centre, double-blind sham-controlled trial in patients with both heterogeneous emphysema and a target lobe with intact interlobar fissures on CT of the thorax. We enrolled stable outpatients with chronic obstructive pulmonary disease who had a forced expiratory volume in 1 s (FEV1) of less than 50% predicted, significant hyperinflation (total lung capacity >100% and residual volume >150%), a restricted exercise capacity (6 min walking distance <450 m), and substantial breathlessness (MRC dyspnoea score ≥3). Participants were randomised (1:1) by computer-generated sequence to receive either valves placed to achieve unilateral lobar occlusion (bronchoscopic lung volume reduction) or a bronchoscopy with sham valve placement (control). Patients and researchers were masked to treatment allocation. The study was powered to detect a 15% improvement in the primary endpoint, the FEV1 3 months after the procedure. Analysis was on an intention-to-treat basis. The trial is registered at controlled-trials.com, ISRCTN04761234. FINDINGS: 50 patients (62% male, FEV1 [% predicted] mean 31·7% [SD 10·2]) were enrolled to receive valves (n=25) or sham valve placement (control, n=25) between March 1, 2012, and Sept 30, 2013. In the bronchoscopic lung volume reduction group, FEV1 increased by a median 8·77% (IQR 2·27-35·85) versus 2·88% (0-8·51) in the control group (Mann-Whitney p=0·0326). There were two deaths in the bronchoscopic lung volume reduction group and one control patient was unable to attend for follow-up assessment because of a prolonged pneumothorax. INTERPRETATION: Unilateral lobar occlusion with endobronchial valves in patients with heterogeneous emphysema and intact interlobar fissures produces significant improvements in lung function. There is a risk of significant complications and further trials are needed that compare valve placement with lung volume reduction surgery. FUNDING: Efficacy and Mechanism Evaluation Programme, funded by the Medical Research Council (MRC) and managed by the National Institute for Health Research (NIHR) on behalf of the MRC-NIHR partnership.


Assuntos
Broncoscopia/métodos , Próteses e Implantes , Enfisema Pulmonar/cirurgia , Idoso , Método Duplo-Cego , Tolerância ao Exercício/fisiologia , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Eur Radiol ; 26(5): 1493-502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26253256

RESUMO

OBJECTIVES: We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. METHODS: Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. RESULTS: Multivariable linear regression yielded a CF: CACS = (1.185 × CCTAS) + (0.002 × CCTAS × attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95% limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CONCLUSION: CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. KEY POINTS: • Coronary calcium scores can be reliably determined on contrast-enhanced cardiac CT • This score can accurately risk stratify patients • Elimination of a dedicated calcium scan reduces patient radiation by a third.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes
4.
J Cardiovasc Comput Tomogr ; 17(6): 436-444, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37865534

RESUMO

BACKGROUND: Detection of intracardiac shunts using CT Coronary Angiography (CTCA) is currently based on anatomical demonstration of defects. We assessed a novel technique using a standard CTCA test bolus in detecting shunts independent of anatomical assessment and to provide an estimate of Qp/Qs. METHODS: We retrospectively reviewed 51 CTCAs: twenty-one from patients with known simple left to right intracardiac shunts with contemporaneous functional assessment (using CMR) within 6 months, 20 controls with structurally normal hearts, and 10 patients with shunt repairs. From the dynamic acquisition of a test bolus, we measured mean Hounsfield Units (HU) in various anatomical structures. We created time/density curves from the test bolus data, and calculated disappearance time (DT) from the ascending aorta (deriving a Qp/Qs), peak ascending aortic HU, and mean coefficient of variation of the arterial curves, and compared these with the Qp/Qs from the respective CMR. RESULTS: Patients with intracardiac shunts had significantly higher test bolus derived Qp/Qs compared with both the controls, and the repaired shunt comparator group. There was a very strong agreement between the test bolus derived Qp/Qs, and Qp/Qs as measured by CMR (Intraclass correlation 0.89). Mean bias was 0.032 â€‹± â€‹0.341 (95% limits of agreement -0.64 to 0.70). Interobserver, and intraobserver agreement of the disappearance time was excellent (0.99, 0.99 (reader 1) and 1.00 (reader 2) respectively). CONCLUSION: In this proof-of-concept study, we demonstrate a novel technique to detect, and to estimate severity of left to right intracardiac shunts on routine Cardiac CT.


Assuntos
Coração , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária , Estudos Retrospectivos , Valor Preditivo dos Testes , Circulação Pulmonar
5.
Eur Heart J ; 30(15): 1837-43, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19502228

RESUMO

AIMS: To demonstrate that exposure to chronic inflammation results in coronary microvascular dysfunction (CMD). METHODS AND RESULTS: Using positron emission tomography, resting and hyperaemic (adenosine, 140 microg/kg/min) myocardial blood flow (MBF) was measured in 25 patients with systemic lupus erythematosus (SLE) or rheumatoid arthritis (RA). Coronary flow reserve (CFR) was calculated as adenosine/resting MBF. Patients had normal or minimally diseased (i.e.

Assuntos
Artrite Reumatoide/fisiopatologia , Circulação Coronária/fisiologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Lúpus Eritematoso Sistêmico/fisiopatologia , Microcirculação/fisiologia , Adenosina , Adulto , Estudos de Casos e Controles , Doença da Artéria Coronariana/fisiopatologia , Endotélio Vascular/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Humanos , Inflamação/fisiopatologia , Masculino , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Medição de Risco , Vasodilatadores
6.
J Comput Assist Tomogr ; 33(2): 161-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19346839

RESUMO

OBJECTIVES: To assess intraobserver and interobserver variation in computed tomography coronary angiography (CTA) in 3 patient cohorts at very low, low-to-intermediate, and intermediate-to-high likelihood of coronary artery disease (CAD). METHODS: One hundred thirty-three patients underwent 64-channel CTA. Coronary arteries were analyzed by 2 experienced blinded observers and reported as having 0%, 1% to 29%, 30% to 49%, 50% to 69%, 70% to 99%, or 100% stenosis. Intraobserver and interobserver agreement was calculated at cohort level and combined. RESULTS: Overall intraobserver and interobserver agreement was good (kappa = 0.74 and kappa = 0.78, respectively). Segmental agreement for stenoses 50% or greater and 70% or greater was greater than 96%. Disagreements were more likely in the presence of noneccentric calcification for both intraobserver (odds ratio = 0.45 and 0.22) and interobserver (odds ratio = 0.40 and 0.10) measurements. CONCLUSIONS: Interobserver and intraobserver variability for the detection of coronary stenoses on CTA is good and justifies routine clinical use. The presence of noneccentric calcium and mixed plaque morphology are important causes of disagreement.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Iohexol/análogos & derivados , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
7.
J Comput Assist Tomogr ; 33(2): 169-74, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19346840

RESUMO

OBJECTIVES: To assess intraobserver and interobserver variability in cardiac computed tomographic measurements of global biventricular function, left ventricular (LV) regional wall motion, systolic wall thickening, and first pass perfusion in 3 patient cohorts at very low, low to intermediate, and intermediate to high cardiac risk. METHODS: One hundred thirty-three patients underwent 64-channel cardiac computed tomography. Images were analyzed by 2 experienced, blinded observers. Intraobserver and interobserver agreements were calculated for each cohort and were combined for patients with structurally normal hearts. RESULTS: Intraobserver and interobserver agreements were good for all global and regional LV parameters with narrow levels of agreement. Right ventricular ejection fraction agreement was also good, but other right ventricular parameters showed wide levels of agreement. CONCLUSIONS: Biventricular ejection fraction, LV regional wall motion, and systolic wall thickening, volume, and mass show good reproducibility for use in standard clinical practice. Right ventricular volumetric and mass data in patients with congenital heart disease should be interpreted with caution.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença das Coronárias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Comorbidade , Meios de Contraste , Doença das Coronárias/epidemiologia , Feminino , Cardiopatias Congênitas/epidemiologia , Humanos , Processamento de Imagem Assistida por Computador , Iohexol/análogos & derivados , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Direita/epidemiologia , Função Ventricular , Ventriculografia de Primeira Passagem
8.
Am J Respir Crit Care Med ; 177(2): 190-4, 2008 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-17962635

RESUMO

RATIONALE: The pathogenic importance of smoking status in idiopathic pulmonary fibrosis (IPF) is uncertain. In theory, increased oxidative stress in current and former smokers might promote disease progression. However, better survival has been reported for current smokers with IPF, although this might reflect less severe disease at presentation (a "healthy smoker effect"). OBJECTIVES: To determine whether smoking status is associated with survival differences in IPF. METHODS: A total of 249 patients with IPF were studied (current smokers, n = 20; former smokers, n = 166; never-smokers, n = 63). Survival was evaluated against smoking status, using proportional hazards analysis, adjusting for sex, age, disease severity (extent of the disease on high-resolution computed tomography, composite physiologic index [CPI], percentage predicted diffusing capacity for carbon monoxide in separate models), and the degree of honeycombing. MEASUREMENTS AND MAIN RESULTS: Current smokers had milder disease than did former smokers, with lower CPI scores (P < 0.0001), less extensive disease on high-resolution computed tomography (P < 0.005), and higher unadjusted survival (hazard ratio = 0.44; 95% confidence interval = 0.24, 0.80; P = 0.007). However, survival did not differ between current and former smokers (P = 0.39) after adjustment for CPI levels. By contrast, the increase in survival seen in nonsmokers than in former smokers (hazard ratio = 0.51; 95% confidence interval = 0.41, 0.83; P = 0.008) was amplified (P < 0.0005) by adjustment for CPI levels. CONCLUSIONS: In IPF, survival and severity-adjusted survival are higher in nonsmokers than in former smokers or the combined group of former and current smokers. By contrast, a better outcome in current smokers, compared with former smokers, reflects less severe disease at presentation and may represent a healthy smoker effect.


Assuntos
Fibrose Pulmonar/mortalidade , Fumar/efeitos adversos , Idoso , Feminino , Seguimentos , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fibrose Pulmonar/etiologia , Fibrose Pulmonar/fisiopatologia , Índice de Gravidade de Doença , Análise de Sobrevida , Capacidade Vital
9.
Eur Heart J ; 29(18): 2244-51, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18573867

RESUMO

AIMS: The PREDICT Study is a prospective cohort study designed to evaluate coronary artery calcification score (CACS) as a predictor of cardiovascular events in type 2 diabetes (T2DM). METHODS AND RESULTS: A total of 589 patients with no history of cardiovascular disease and with established T2DM had CACS measured, as well as risk factors, including plasma lipoprotein, apolipoprotein, homocysteine and C-reactive protein concentrations, homeostasis model assessment insulin resistance (HOMA-IR), and urine albumin creatinine ratio. Participants were followed for a median of 4 years and first coronary heart disease (CHD) and stroke events were identified as primary endpoints. There were 66 first cardiovascular events (including 10 strokes). CACS was a highly significant, independent predictor of events (P < 0.001), with a doubling in CACS being associated with a 32% increase in risk of events (29% after adjustment). Hazard ratios relative to CACS in the range 0-10 Agatston units (AU) were: CACS 11-100 AU, 5.4 (P = 0.02); 101-400 AU 10.5 (P = 0.001); 401-1000 AU, 11.9 (P = 0.001), and >1000 AU, 19.8 (P < 0.001). Only HOMA-IR predicted primary endpoints independently of CACS (P = 0.01). The areas under the receiver operator characteristic curve for United Kingdom Prospective Diabetes Study (UKPDS) risk engine primary endpoint risk and for UKPDS risk plus CACS were 0.63 and 0.73, respectively (P = 0.03). CONCLUSION: Measurement of CACS is a powerful predictor of cardiovascular events in asymptomatic patients with T2DM and can further enhance prediction provided by established risk models.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Proteína C-Reativa/metabolismo , Calcinose/metabolismo , Diabetes Mellitus Tipo 2/complicações , Progressão da Doença , Feminino , Humanos , Resistência à Insulina/fisiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco
10.
J Nucl Cardiol ; 15(3): 311-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18513637

RESUMO

BACKGROUND: Multislice computed tomography coronary angiography (CTA) was proposed as a method for investigating possible coronary artery disease (CAD) in patients who present with chest pain but with a low to intermediate likelihood of CAD. Sixty-four-channel CTA was compared prospectively with (99m)Tc-tetrofosmin myocardial perfusion scintigraphy (MPS) (as the gold standard in the detection of flow-limiting stenoses) for the detection of functionally significant CAD. METHODS AND RESULTS: Fifty-two consecutive symptomatic patients with a low to intermediate likelihood of coronary artery disease, and who were referred for MPS, also underwent CTA. The CTA datasets were analyzed by two experienced observers who were blinded to the MPS data, and coronary artery segments were reported as < 50%, 50% to 69%, 70% to 99% stenoses, or occluded. The MPS images were similarly analyzed for inducible perfusion abnormalities, and coronary territories were identified. At the patient level, agreement between CTA and MPS for CTA lesions at >/= 50% was 87% (sensitivity, 100%; specificity, 84%; positive predictive value, 50%; negative predictive value, 100%). For CTA lesions, agreement at >/= 70% was 96% (sensitivity, 86%; specificity, 98%; positive predictive value, 86%; negative predictive value, 98%). CONCLUSIONS: In patients with a low to intermediate likelihood of CAD, there is good correlation between MPS and CTA for the detection of functionally significant coronary artery stenoses when CTA detects a narrowing of >/= 70% severity. Computed tomography coronary angiography stenoses of 70% should be used to determine functional significance, and not 50%, as is the usual practice at present.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Seleção de Pacientes , Intensificação de Imagem Radiográfica/métodos , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Cintilografia , Fatores de Risco
11.
J Nucl Cardiol ; 15(4): 497-502, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18674716

RESUMO

BACKGROUND: Cardiac computed tomography (CCT) has the potential to assess both coronary anatomy and ventricular function in a single study. We examined the agreement between CCT and myocardial perfusion scintigraphy (MPS) for the assessment of global and regional ventricular function. METHODS AND RESULTS: Research CCT was performed in 52 patients with a low to intermediate likelihood of coronary artery disease referred for MPS. Left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction (LVEF), and myocardial wall motion and thickening were compared between techniques. In addition, myocardial contrast attenuation on CCT was compared with radiotracer uptake on MPS. LVEF values agreed well (mean difference, 4.1%; SD, 15.13%), but CCT left ventricular end-diastolic volume was greater compared with MPS (mean difference, 46.0 mL; SD, 33.34 mL) (P < .001). There was moderate agreement for segmental myocardial motion and thickening, with kappa values of 0.57 (95% confidence interval, 0.51-0.63) and 0.47 (95% confidence interval, 0.41-0.53), respectively. Seventeen patients had hypoattenuation in at least 1 myocardial segment on CCT. Three of four patients with concomitant abnormalities of wall motion and thickening on CCT had infarction in the same territory on MPS. CONCLUSIONS: There was good agreement for LVEF between CCT and MPS but myocardial volumes differed, and these modalities cannot be used interchangeably. Mild abnormalities of regional function are detected more commonly by CCT than by MPS. Myocardial hypoattenuation on CCT is highly specific for myocardial infarction when associated with reduction of systolic wall thickening and regional wall motion abnormality.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Open Heart ; 4(2): e000626, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28878951

RESUMO

OBJECTIVE: High-pitch protocols are increasingly used in cardiovascular CT assessment for transcatheter aortic valve implantation (TAVI), but the impact on diagnostic image quality is not known. METHODS: We reviewed 95 consecutive TAVI studies: 44 (46%) high-pitch and 51 (54%) standard-pitch. Single high-pitch scans were performed regardless of heart rate. For standard-pitch acquisitions, a separate CT-aortogram and CT-coronary angiogram were performed with prospective gating, unless heart rate was ≥70 beats/min, when retrospective gating was used. The aortic root and coronary arteries were assessed for artefact (significant artefact=1; artefact not limiting diagnosis=2; no artefact=3). Aortic scans were considered diagnostic if the score was >1; the coronaries, if all three epicardial arteries scored >1. RESULTS: There was no significant difference in diagnostic image quality for either the aorta (artefact-free high-pitch: 31 (73%) scans vs standard-pitch: 40 (79%), p=0.340) or the coronary tree as a whole (10 (23%) vs 15 (29%), p=0.493). However, proximal coronary arteries were less well visualised using high-pitch acquisitions (16 (36%) vs 30 (59%), p=0.04). The median (IQR) radiation dose was significantly lower in the high-pitch cohort (dose-length product: 347 (318-476) vs 1227 (1150-1474) mGy cm, respectively, p<0.001), and the protocol required almost half the amount of contrast. CONCLUSIONS: The high-pitch protocol significantly reduces radiation and contrast doses and is non-inferior to standard-pitch acquisitions for aortic assessment. For aortic root assessment, the high-pitch protocol is recommended. However, if coronary assessment is critical, this should be followed by a conventional standard-pitch, low-dose, prospectively gated CT-coronary angiogram if the high-pitch scan is non-diagnostic.

13.
J Thorac Imaging ; 31(3): 177-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27007667

RESUMO

PURPOSE: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. MATERIALS AND METHODS: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. RESULTS: The high-pitch protocol better demonstrated the pulmonary veins (P=0.03) and all coronary segments (all P<0.05), except the distal right coronary artery (P=0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P<0.01) and motion (P<0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P=0.05] due to greater z-overscanning. CONCLUSIONS: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.


Assuntos
Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Coração/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
14.
J Thorac Cardiovasc Surg ; 130(1): 41-7, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15999039

RESUMO

OBJECTIVE: This article describes a novel interactive method for quantitative evaluation of calcium deposits in the aortic valve by means of electron beam tomography data fusion technique. METHODS: The technique relied on the use of hierarchic 3-dimensional free-form volume registration with fast global optimization between normally acquired and contrast-enhanced electron beam tomographic volume. A total of 66 contrast-enhanced electron beam tomographic scans of the aortic root were performed in 27 patients, 10 with native aortic valve disease (group A) and 17 from a prospective randomized trial of aortic root replacement (group B, 9 Freestyle grafts [Medtronic, Inc, Minneapolis, Minn] and 8 homografts). To validate the in vivo electron beam tomographic measurements, 5 patients from group A underwent electron beam tomographic scans before the operation and then had their own valves, explanted at the time of surgery, analyzed for calcium quantification by ex vivo electron beam tomography. RESULTS: In group A, the mean (+/- SE) calcification score was 6560 +/- 2388, which correlated with peak gradients measured at echocardiography ( r = 0.93, P = .02). In group B, the mean (+/- SE) calcification score was 168 +/- 27, showing a tendency toward a lower calcification for Freestyle valves than for homografts at 2 years after implantation ( P = .052). A mean variability of 6% was found between in vivo electron beam tomographic scores of calcification and those measured on valve specimens after explantation. CONCLUSION: We describe a novel method to characterize the degree and location of calcification in both native valves and postoperative valve implants. The technique may be useful in the management of patients with aortic valve disease and has potential as a screening tool for high-risk patients to diagnose early valve calcification and possibly institute corrective measures.


Assuntos
Valva Aórtica/patologia , Bioprótese , Calcinose/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X , Idoso , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade
15.
Diabetes Care ; 25(10): 1813-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12351483

RESUMO

OBJECTIVE: In 196 type 1 diabetic subjects and 195 nondiabetic subjects aged 30-55 years, we examined whether C-reactive protein (CRP) is elevated in diabetes and whether CRP is associated with coronary artery calcification (CAC). RESEARCH DESIGN AND METHODS: CRP was measured with a highly sensitive immunoassay. CAC was measured using electron beam computed tomography. RESULTS: CRP was elevated in diabetic women compared with nondiabetic women (median 1.62 vs. 0.85 mg/l, P < 0.001) independently of other factors, but was similar in diabetic and nondiabetic men (median 0.82 vs. 0.81 mg/l). Insulin dose per day was positively correlated with CRP in diabetic women (Spearman's rho = 0.36, P = 0.0003) but much less so in men (rho = 0.16, P = 0.09). Being in the top tertile for CRP was associated with CAC in diabetic and nondiabetic men even after adjustment for other risk factors (adjusted odds ratio [OR] = 4.6 and 4.3, respectively, P = 0.02 for both). In nondiabetic women, being in the top tertile for CRP was associated with CAC (OR 3.1, P = 0.04), but not independently of BMI (OR = 1 after adjustment). Among diabetic women the association was not significant even before adjustment for BMI (OR = 2.6, P = 0.07). CONCLUSIONS: Elevated CRP in diabetic women might reflect a particular sensitivity to insulin levels or might reflect insulin resistance. In general, CRP is an important marker of subclinical atherosclerosis, but the clinical significance of elevated CRP in diabetic women needs to be addressed in prospective studies, since CRP was not clearly associated with CAC in this group.


Assuntos
Biomarcadores/sangue , Proteína C-Reativa/análise , Calcinose/patologia , Doença das Coronárias/patologia , Diabetes Mellitus Tipo 1/sangue , Angiopatias Diabéticas/sangue , Adulto , Constituição Corporal , Índice de Massa Corporal , Calcinose/sangue , Doença das Coronárias/sangue , Diabetes Mellitus Tipo 1/patologia , Angiopatias Diabéticas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Caracteres Sexuais
16.
J Cardiovasc Comput Tomogr ; 9(5): 463-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25977110

RESUMO

We present the case of a neonate with pulmonary atresia and persistent bilateral patent ductus arteriosus imaged by gated multidetector CT. Traditionally, these patients have been assessed preoperatively with invasive angiocardiography or with cardiovascular magnetic resonance under sedation. Our case illustrates that contemporary cardiovascular CT techniques can now be used for preoperative evaluation with minimal radiation penalty, obviating the risks of sedation or cardiac catheterization.


Assuntos
Anormalidades Múltiplas/diagnóstico por imagem , Permeabilidade do Canal Arterial/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Atresia Pulmonar/diagnóstico por imagem , Procedimento de Blalock-Taussig , Permeabilidade do Canal Arterial/cirurgia , Humanos , Recém-Nascido , Ligadura , Masculino , Valor Preditivo dos Testes , Atresia Pulmonar/cirurgia , Doses de Radiação
17.
J Cardiovasc Comput Tomogr ; 9(2): 89-102, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25819192

RESUMO

Cardioembolic stroke is an important complication of atrial fibrillation. The thrombus responsible for this arises from the left atrial appendage (LAA) in >90% of cases, providing the rationale for device-based LAA closure as a means of thromboprophylaxis. Although oral anticoagulant therapy remains the mainstay for reducing the risk of stroke in patients with atrial fibrillation, an increasing number of patients, particularly those ineligible for conventional pharmacotherapy, are being offered percutaneous left atrial appendage closure. Cardiovascular CT can provide important information to assess the suitability of patients for LAA interventions and guide device selection and approach. The high spatial resolution and multiplanar capability of contemporary contrast-enhanced gated multidetector cardiovascular CT render it an ideal modality for noninvasively evaluating patients before intervention and assessing patients after intervention both for complications and procedural outcome.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Acidente Vascular Cerebral/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Apêndice Atrial/patologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Fotografação , Prognóstico , Medição de Risco , Dispositivo para Oclusão Septal , Resultado do Tratamento
18.
Int J Cardiovasc Imaging ; 31(7): 1435-46, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26068211

RESUMO

Transcatheter aortic valve implantation (TAVI) is an effective treatment option for patients with severe degenerative aortic valve stenosis who are high risk for conventional surgery. Computed tomography (CT) performed prior to TAVI can detect pathologies that could influence outcomes following the procedure, however the incidence, cost, and clinical impact of incidental findings has not previously been investigated. 279 patients underwent CT; 188 subsequently had TAVI and 91 were declined. Incidental findings were classified as clinically significant (requiring treatment), indeterminate (requiring further assessment), or clinically insignificant. The primary outcome measure was all-cause mortality up to 3 years. Costs incurred by additional investigations resultant to incidental findings were estimated using the UK Department of Health Payment Tariff. Incidental findings were common in both the TAVI and medical therapy cohorts (54.8 vs. 70.3%; P = 0.014). Subsequently, 45 extra investigations were recommended for the TAVI cohort, at an overall average cost of £32.69 per TAVI patient. In a univariate model, survival was significantly associated with the presence of a clinically significant or indeterminate finding (HR 1.61; P = 0.021). However, on multivariate analysis outcomes after TAVI were not influenced by any category of incidental finding. Incidental findings are common on CT scans performed prior to TAVI. However, the total cost involved in investigating these findings is low, and incidental findings do not independently identify patients with poorer outcomes after TAVI. The discovery of an incidental finding on CT should not necessarily influence or delay the decision to perform TAVI.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Angiografia Coronária/economia , Custos de Cuidados de Saúde , Implante de Prótese de Valva Cardíaca/métodos , Achados Incidentais , Tomografia Computadorizada por Raios X/economia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Causas de Morte , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Londres , Masculino , Modelos Econômicos , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Fatores de Risco , Fatores de Tempo
19.
Atherosclerosis ; 163(2): 363-9, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12052484

RESUMO

The relationship of activated factor XII (FXIIa) and FXII 46C>T genotype to coronary atherosclerosis and endothelial function was examined in 192 randomly sampled subjects from the general population and 190 type 1 diabetic subjects (mean age 38+/-4 years). Coronary artery calcification (CAC) was measured using Electron beam CT. von Willebrand factor (vWF), a marker of endothelial function, and FXIIa were measured by ELISA. Endothelial nitric oxide production was quantified as the forearm blood flow response to intra-brachial infusion of bradykinin and N(G) monomethyl-L-arginine (L-NMMA). A higher FXIIa was independently associated with higher triglycerides (P<0.001), BMI (P=0.001), alcohol consumption (P=0.003) and vWF (P<0.001) in non-diabetic subjects and with insulin dose (P=0.009), total cholesterol (P=0.02) and alcohol (P<0.001) in diabetic subjects. Diabetic subjects had lower FXIIa (1.55 ng/ml) than non-diabetic subjects (1.92 ng/ml, P<0.001). Higher FXIIa was associated with lower response to bradykinin (P=0.048) and to L-NMMA (P=0.029). FXIIa was positively associated with CAC (odds ratio=1.57 for every 1 ng/ml higher FXIIa, P=0.005) but not independently of other risk factors (odds ratio=1.1 on adjustment). 46C>T genotype explained 18% of the variance in FXIIa (P<0.001) but was not associated with CAC (P=0.6). We conclude that plasma FXIIa is under strong genetic control but also reflects plasma triglycerides and endothelial activation or dysfunction. FXIIa appears unlikely to be directly atherogenic but may be a useful marker of coronary atherosclerosis because of its association with these other factors. Type 1 diabetes is associated with lower levels of FXIIa despite a greater prevalence of atherosclerosis.


Assuntos
Calcinose/etiologia , Doença das Coronárias/etiologia , Diabetes Mellitus Tipo 1/metabolismo , Fator XIIa/genética , Genótipo , Adulto , Biomarcadores/análise , Doença da Artéria Coronariana/etiologia , Diabetes Mellitus Tipo 1/complicações , Endotélio Vascular/fisiopatologia , Fator XIIa/análise , Fator XIIa/metabolismo , Feminino , Humanos , Masculino , Óxido Nítrico/metabolismo , Polimorfismo Genético , Distribuição Aleatória , Risco
20.
J Heart Valve Dis ; 11(3): 402-7; discussion 408, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12056735

RESUMO

BACKGROUND AND AIM OF THE STUDY: Electron beam tomography (EBT) has been used previously to study aortic root wall and leaflet calcification. However, the sensitivity of this method must be validated by comparing EBT findings with calcification in the cusps as determined using other techniques. An in-vitro study was designed to examine the correlation between EBT scores of calcification, visual observations, traditional X-radiography, dual-energy X-ray analysis (DEXA) and atomic absorption spectroscopy (AAS). METHODS: Seven commercial and experimental pericardial valves were implanted in the mitral position in juvenile sheep for up to 20 weeks. Valves were examined thoroughly upon explantation and traditional x-radiographs were taken using standard techniques and ranked in increasing order of calcification. A calcification score in Hounsfield Units (HU) and a calcified volume score in mm3 were calculated for each valve by EBT. Calcium content was then calculated by means of DEXA and AAS. RESULTS: Calcification scores ranged from 1.03 to 538.93 HU, and calcified volume scores from 6.18 to 1804.6 mm3. Correlation analysis showed a good agreement between the physical observations, in-vitro traditional X-radiography and both the calcification score and calcified volume score. EBT measurements were highly correlated with the DEXA examinations (r = 0.98, p = 0.0001 versus calcification score; and r = 0.97, p = 0.0003 versus calcified volume score) and AAS analyses (r = 0.98, p = 0.0001 versus calcification score; and r = 0.99, p = 0.0000 versus calcified volume score). CONCLUSION: These preliminary results indicate a good correlation between the physical observations of calcification, X-radiographic observations, DEXA, AAS analyses and EBT measures of calcification.


Assuntos
Calcinose/complicações , Calcinose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Tomografia Computadorizada por Raios X , Absorciometria de Fóton , Animais , Cardiomiopatias/complicações , Modelos Animais de Doenças , Modelos Cardiovasculares , Ovinos , Espectrofotometria Atômica , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA