Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 111, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443957

RESUMO

BACKGROUND: Access to timely and accurate diagnostic imaging is essential for high-quality healthcare. Point-of-care ultrasound has been shown to be accessible and effective in many aspects of healthcare, including assessing changes in lung pathology. However, few studies have examined self-administered at-home lung ultrasound (SAAH-LUS), in particular performed by non-clinical patients (NCPs). RESEARCH QUESTION: Are NCPs able to perform SAAH-LUS using remote teleguidance and produce interpretable images? STUDY DESIGN: Patients were enrolled to the study in a mix of in-person and virtual recruitment, and shipped a smartphone as well as a point of care ultrasound device. Tele-guidance was provided by a remote physician using software integrated with the point of care ultrasound device, allowing real-time remote visualization and guidance of a patient scanning their own chest. A post-intervention survey was conducted to assess patient satisfaction, feasibility, and acceptability of SAAH-LUS. Two POCUS expert reviewers reviewed the scans for interpretability, and inter-rater agreement between the two reviewers was also computed. RESULTS: Eighteen patients successfully underwent 7-14 days of daily telemedicine in parallel to daily SAAH-LUS. Across 1339 scans obtained from ten different lung zones, the average proportion of interpretability was 96% with a chance-corrected agreement, or Cohen's kappa, reported as κ = 0.67 (significant agreement). 100% of NCPs surveyed found SAAH-LUS to be a positive experience, particularly for its ease of operation and ability to increase access to healthcare services. INTERPRETATION: This study demonstrates that NCPs can obtain interpretable LUS images at home, highlighting the potential for SAAH-LUS to increase diagnostic capacity, particularly for rural and remote regions where complex imaging and healthcare providers are difficult to obtain. Trial registration The clinical trials has been registered (clinicaltrials.gov). REGISTRATION NUMBER: NCT04967729.


Assuntos
Pessoal de Saúde , Tórax , Humanos , Pulmão/diagnóstico por imagem , Satisfação do Paciente , Ultrassonografia
2.
N Engl J Med ; 375(18): 1805, 2016 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-28112883
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA