1.
Nihon Rinsho ; 63(9): 1594-600, 2005 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-16164217

RESUMO

Even though the advancement of pharmacotherapy, the maintenance treatment to keep the function of degenerated and destructed joint on rheumatoid arthritis and the surgical treatment for joint reconstruction are very important to prevent the patients from being bedridden and to keep the quality of life. The adaptation of operation varies among disease stage and site of bone destruction. Missing the chance of operation, it becomes impossible to perform surgical treatment. So it is important to consult with specialist finding proper opportunity.


Assuntos
Artrite Reumatoide/cirurgia , Medicina Baseada em Evidências , Humanos , Procedimentos Ortopédicos/métodos
2.
J Arthroplasty ; 23(4): 522-6, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18514868

RESUMO

The Harris-Galante I modular acetabular components (Zimmer, Warsaw, Ind) were most widely used in the 1980s in primary and revision total hip arthroplasty. We assessed 76 primary total hip arthroplasties performed using Harris-Galante I modular acetabular components. Dissociation of the polyethylene liner occurred in 5 patients and required revision surgery. None of the 76 hips had fractures of the metal locking tines on the metal shell. Liner dissociation was attributed to fatigue fracture of the polyethylene, a result of a gap between the liner and the metal shell. The thin polyethylene liner rim aggravated failure. The revision technique was to cement the polyethylene liner into the well-fixed Harris-Galante metal shell. The average follow-up observation period after revision surgery was 6.4 years; and there was no recurrence of dissociation, which supports the use of our revision technique.


Assuntos
Prótese de Quadril , Polietileno , Complicações Pós-Operatórias/etiologia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Radiografia , Reoperação , Estresse Mecânico
3.
J Arthroplasty ; 21(8): 1105-10, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17162168

RESUMO

We assessed 106 total hip arthroplasties performed with a new metal-on-metal hip system; the patients were monitored for at least 5 years. The average Harris Hip Score of the patients was 39.5 points before surgery and 87.8 points at final follow-up evaluation. Radiographically, the acetabular component was stable in 103 hips and possibly unstable in 3 hips. The femoral component was bone ingrown in 97 hips and stable and fibrous in 9. After surgery, 6 hips dislocated. The polyethylene liner dissociated in one patient. No patient exhibited clear signs of loosening, migration, or osteolysis. Distal femoral cortical hypertrophy was seen in 35.8% of the cases. Survival at the mean follow-up point (6.4 years) was 99.1%. There was no significant difference in serum chromium concentration between metal-on-metal bearings and polyethylene-on-metal bearings (control subjects). This study found that metal-on-metal total hip arthroplasty produces excellent midterm results.


Assuntos
Prótese de Quadril , Acetábulo , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Cromo/sangue , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia
SELEÇÃO DE REFERÊNCIAS