Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38415804

RESUMO

PURPOSE: Investigate survival and technical complications of two-unit posterior implant-supported cantilever made of monolithic zirconia on titanium-base abutments (Zr-TiB) vs. porcelain-fused-to-metal on castable gold abutments (PFM-GA) using two different implant connections, internal butt-joint (IBJ) and internal conical (IC). MATERIALS AND METHODS: Forty-eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2-unit mandibular premolar cantilevers with two different materials (Zr-TiB vs. PFM-GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr-TiB; (2) IBJ/PFM-GA; (3) IC/Zr-TiB; and (4) IC/PFM-GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5-55°C) with occlusal axial load on the pontic. Catastrophic and non-catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated. RESULTS: From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM-GA) to 100% (IBJ/Zr-TiB; IBJ/PFM-GA; IC/Zr-TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB - 67%) compared to internal butt-joint (IBJ/Zr-TiB - 44%; IBJ/PFM-GA - 46%) (p < .01). Bending moments were higher in internal butt-joint connections than in internal conical (p < .05). CONCLUSION AND CLINICAL IMPLICATIONS: Two-unit posterior implant-supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium-base abutments demonstrated higher mechanical stability compared to porcelain-fused-to-metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain-fused-to-metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.

2.
Clin Oral Implants Res ; 35(4): 377-385, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38170349

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of sterilization on the retention forces of lithium disilicate (LD) and polymer-infiltrated ceramic network (PICN) crowns bonded to titanium base (Ti-base) abutments. MATERIALS AND METHODS: Forty LD and 40 PICN crowns were milled and then bonded to 80 Ti-bases with two resin composite cements: Multilink Hybrid Abutment (mh) and Panavia V5 (pv) for a total of 8 groups (n = 10). Half of the specimens (test) underwent an autoclaving protocol (pressure 1.1 bar, 121°C, 20.5 min) and the other half not (control). Restorations were screw-retained to implants, and retention forces (N) were measured with a pull-off testing machine. The surfaces of the Ti-bases and the crowns were inspected for the analysis of the integrity of the marginal bonding interface and failure mode. Student's t-test, chi-square test, and univariate linear regression model were performed to analyze the data (α = 0.05). RESULTS: The mean pull-off retention forces ranged from 487.7 ± 73.4 N to 742.2 ± 150.3 N. Sterilized groups showed statistically significant overall higher maximum retention forces (p < .05), except for one combination (LD + mh). Sterilization led to an increased presence of marginal gaps and deformities compared to no-sterilization (p < .001), while no statistically significant relationship was found between failure mode and sterilization (p > .05). CONCLUSIONS: Sterilization may have a beneficial effect on the retention forces of LD and PICN crowns bonded to titanium base abutments, although it may negatively influence the integrity of the marginal bonding interface.


Assuntos
Polímeros , Titânio , Porcelana Dentária , Coroas , Teste de Materiais , Zircônio , Cerâmica , Análise do Estresse Dentário , Dente Suporte , Desenho Assistido por Computador
3.
J Esthet Restor Dent ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757761

RESUMO

OBJECTIVES: To provide an overview of the current artificial intelligence (AI) based applications for assisting digital data acquisition and implant planning procedures. OVERVIEW: A review of the main AI-based applications integrated into digital data acquisitions technologies (facial scanners (FS), intraoral scanners (IOSs), cone beam computed tomography (CBCT) devices, and jaw trackers) and computer-aided static implant planning programs are provided. CONCLUSIONS: The main AI-based application integrated in some FS's programs involves the automatic alignment of facial and intraoral scans for virtual patient integration. The AI-based applications integrated into IOSs programs include scan cleaning, assist scanning, and automatic alignment between the implant scan body with its corresponding CAD object while scanning. The more frequently AI-based applications integrated into the programs of CBCT units involve positioning assistant, noise and artifacts reduction, structures identification and segmentation, airway analysis, and alignment of facial, intraoral, and CBCT scans. Some computer-aided static implant planning programs include patient's digital files, identification, labeling, and segmentation of anatomical structures, mandibular nerve tracing, automatic implant placement, and surgical implant guide design.

4.
J Esthet Restor Dent ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334315

RESUMO

OBJECTIVES: Aim of this study was to assess survival rates, radiographic, and pink esthetic outcomes of a bone-level-tapered (BLT) implant following immediate or early implant placement. MATERIALS AND METHODS: Patients in need of tooth extraction and one implant in the anterior or premolar area were recruited in five centers. Patients were randomly assigned to the immediate or early placement protocol. Implants were restored with all-ceramic crowns cemented to titanium-base-abutments. Radiographic bone levels, implant stability quotient (ISQ), and pink esthetic outcomes were assessed. Data were analyzed descriptively. Level of significance was set at 0.05. Differences between groups were tested using Wilcoxon-signed-rank and Mann-Whitney-U test as nonparametric tests. RESULTS: A total of 60 patients received 60 BLT implants (Institut Straumann). At 12-months, 59 implants (98.3%) were osseointegrated. The mean distance from implant shoulder to first bone-to-implant contact was 0.15 ± 0.59 mm without significant differences between the groups. Median ISQ values increased from 75.5 to 78.5. A mean buccal recession of 0.1 ± 0.70 mm occurred with no difference between groups. The mean papilla height gain in both groups was 0.5 ± 1.47 mm mesially and 0.4 ± 1.36 mm distally. CONCLUSIONS: After 1 year, immediately and early placed BLT implants exhibit similar bone level changes, ISQ values, and pink esthetic outcomes. CLINICAL SIGNIFICANCE: The present research contributes to the knowledge on clinical outcomes of immediately and early placed BLT implants restored with buccally microveneered ceramic single crowns out of two different ceramic materials. The research shows that similar esthetic and radiographic outcomes can be reached by means of immediate implant placement compared to the conventional early placement protocol. The improvement of esthetic soft-tissue parameters over time was shown for both implant placement protocols.

5.
J Esthet Restor Dent ; 36(1): 164-173, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38173277

RESUMO

AIM: The aim of this randomized, prospective, and clinical multicenter study was to compare the overall clinical performance of two restorative options over a 5-year period: individualized CAD/CAM abutments veneered with a hand-layered ceramic, and prefabricated zirconium dioxide abutments veneered with press ceramic and inserted into a single edentulous gap in the anterior maxilla. MATERIALS AND METHODS: Forty subjects were recruited from two universities: 20 from the University of XX and 20 from the University of XY. Each subject received an implant to restore a single edentulous gap in the maxillary anterior region (14-24 FDI). 20 patients were randomized into each Group. Group A received a one-piece single crown produced from a prefabricated zirconia abutment with pressed ceramic and Group B received an individualized CAD/CAM zirconia abutment with a hand-layered technique. After 5 years, the aesthetic and radiographic parameters were assessed. RESULTS: Group A had four dropouts and one failure, resulting in a 95% survival rate and 95% success rate. Group B had two dropouts and two failures which resulted in a 90% survival rate and 90% success rate. No crestal bone level changes were observed, with a mean DIB of 0.06 mm in Group A and 0.09 mm in Group B. No statistically significant differences were present at baseline, 6 months, 1 year, 3 years, or 5 years for DIB values between time points and groups. Pink aesthetic score/white aesthetic score, Peri-Implant and Crown Index, and Implant Crown Aesthetic Index values were stable over time at all five points for both groups. CONCLUSION: Both implant-supported restorative options represent a valuable treatment option for the restoration of implant crowns in the anterior maxilla. CLINICAL SIGNIFICANCE: In general, the use of ceramic abutments in the anterior zone represents a valuable treatment procedure with both standardized and CAD/CAM individualized abutments and following the recommendations from the respective manufacturer(s).


Assuntos
Cerâmica , Zircônio , Humanos , Estudos Prospectivos , Coroas , Desenho Assistido por Computador , Dente Suporte , Titânio
6.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772362

RESUMO

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Colagem Dentária/métodos , Cimentos de Resina/química
7.
J Prosthodont ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507280

RESUMO

PURPOSE: The aims of the present study were (a) to compare the scanning time and image count to complete optical scans of a typodont between augmented-reality-assisted intraoral scanning (ARIOS) and intraoral scanning (IOS); (b) to compare the accuracy of the digital casts derived from ARIOS and IOS; (c) to compare participant-related outcomes between ARIOS and IOS. MATERIALS AND METHODS: A multi-session within-subject experiment was conducted to compare ARIOS and IOS. Thirty-one dental students participated in the study. Following a trial session, each participant obtained optical scans under ARIOS and IOS conditions. The time required to complete the scan, and the number of images taken were recorded. Participant feedback was collected using entry, exit, and NASA-Task Load Index (TLX) surveys. The accuracy of the digital casts derived from the optical scans was measured in root mean square error (RMSE). RESULTS: The present study found a 6.8% increase in preference for ARIOS from entry to exit survey. Slightly more participants favored the ARIOS setup compared to IOS; 54.8% of participants favored ARIOS, 9.7% were indifferent, and 35.5% favored IOS. NASA-TLX subscale ratings were higher for IOS in general apart from mental demand. The accuracy of the digital casts between ARIOS and IOS was comparable in RMSE. CONCLUSION: ARIOS was advantageous compared to IOS in ergonomics, improved scanner tracking, and ease of scanner orientation. However additional trials, increased field of view, and better superimposition of scanning status to the target site were improvements desired by the study participants.

8.
J Clin Periodontol ; 50 Suppl 25: 22-37, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35246885

RESUMO

AIM: To evaluate outcome measures, methods of assessment, and analysis in clinical studies on fixed single- and multiple-unit implant restorations. MATERIALS AND METHODS: Three independent electronic database searches (MEDLINE, EMBASE, and Cochrane) were done to identify prospective and retrospective clinical studies published from January 2011 up to June 2021 with ≥20 patients and minimum 1-year follow-up period on technical and clinical outcomes of implant-supported single crowns (SCs) and partial fixed dental prostheses (P-FDPs). An entire data extraction was performed to identify primarily the most reported outcome measures and later to define the choice of assessment methods of those outcome measures. The outcomes were analysed descriptively, and the strength of association was evaluated using the Pearson chi-square test (p ≤ .05). RESULTS: In a total 531 studies, 368 on SCs (69.3%), 70 on P-FDPs (13.1%), and 93 on both restoration types (17.5%) were included; 56.3% of all studies did not clearly define a primary outcome. The most frequent primary outcome was marginal bone level (MBL) (55.2%) followed by implant survival (5.3%), professional aesthetic evaluation (3.4%), and technical complications (2.1%). Peri-implant indices were the most reported secondary outcome (55.1%), followed by implant survival (39.9%), MBL (36%), and implant success (26.4%). Prosthetic failure (seven studies [3.9%]) was one of the least reported outcome measures. CONCLUSIONS: Outcome measures and their assessment methods showed high heterogeneity among studies. Primary outcomes were not often defined clearly, and the most frequently selected primary outcome was marginal bone loss. Prosthetic outcomes, implant survival, and patient-related outcomes were only infrequently reported.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Estudos Prospectivos , Estudos Retrospectivos , Estética Dentária , Coroas , Avaliação de Resultados em Cuidados de Saúde , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Prótese Parcial Fixa
9.
J Clin Periodontol ; 50 Suppl 25: 5-21, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37143289

RESUMO

AIM: Lack of consistently reported outcomes limits progress in evidence-based implant dentistry and quality of care. The objective of this initiative was to develop a core outcome set (COS) and measurements for implant dentistry clinical trials (ID-COSM). MATERIALS AND METHODS: This Core Outcome Measures in Effectiveness Trials (COMET)-registered international initiative comprised six steps over 24 months: (i) systematic reviews of outcomes reported in the last 10 years; (ii) international patient focus groups; (iii) a Delphi project with a broad range of stakeholders (care providers, clinical researchers, methodologists, patients and industry representatives); (iv) expert group discussions organizing the outcomes in domains using a theoretical framework and identifying the COSs; (v) identification of valid measurement systems to capture the different domains and (vi) final consensus and formal approval involving experts and patients. The methods were modified from the best practice approach following the Outcome Measures in Rheumatoid Arthritis Clinical Trial and COMET manuals. RESULTS: The systematic reviews and patient focus groups identified 754 (665 + 89, respectively) relevant outcome measures. After elimination of redundancies and duplicates, 111 were formally assessed in the Delphi project. By applying pre-specified filters, the Delphi process identified 22 essential outcomes. These were reduced to 13 after aggregating alternative assessments of the same features. The expert committee organized them into four core outcome areas: (i) pathophysiology, (ii) implant/prosthesis lifespan, (iii) life impact and (iv) access to care. In each area, core outcomes were identified to capture both the benefits and harms of therapy. Mandatory outcome domains included assessment of surgical morbidity and complications, peri-implant tissue health status, intervention-related adverse events, complication-free survival and overall patient satisfaction and comfort. Outcomes deemed mandatory in specific circumstances comprised function (mastication, speech, aesthetics and denture retention), quality of life, effort for treatment and maintenance and cost effectiveness. Specialized COSs were identified for bone and soft-tissue augmentation procedures. The validity of measurement instruments ranged from international consensus (peri-implant tissue health status) to early identification of important outcomes (patient-reported outcomes identified by the focus groups). CONCLUSIONS: The ID-COSM initiative reached a consensus on a core set of mandatory outcomes for clinical trials in implant dentistry and/or soft tissue/bone augmentation. Adoption in future protocols and reporting on the respective domain areas by currently ongoing trials will contribute to improving evidence-informed implant dentistry and quality of care.


Assuntos
Implantes Dentários , Projetos de Pesquisa , Humanos , Resultado do Tratamento , Consenso , Qualidade de Vida , Estética Dentária , Avaliação de Resultados em Cuidados de Saúde
10.
Clin Oral Implants Res ; 34(1): 56-65, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36321877

RESUMO

OBJECTIVES: To investigate survival rates, technical and biologic outcomes of buccally micro-veneered all-ceramic single implant crowns. MATERIAL AND METHODS: Sixty subjects randomly received immediately or early placed implants. Crowns out of lithium-disilicate (n = 30) and zirconia-ceramic (n = 30) were bonded to titanium-base-abutments. Restorations were inspected at baseline (BL) and during follow-up visits (6, 12 months). Technical and biologic parameters were recorded. Data were analysed descriptively. Differences between groups were tested with Student's t-test. Paired T-test was used when comparing data from the same implant or tooth over time. Linear model repeated measures were used to test differences between materials over time. Differences in counts were evaluated using Pearson Chi-square test. The level of significance was at p < .05. RESULTS: After a mean observation time of 13.2 ± 2.4 months, 54 restorations were re-examined. The implant survival rate was 98.3%, and the restoration survival rate was 100%. One early implant failure occurred. Two minor chippings occurred in lithium-disilicate restorations. No chippings or fractures occurred in any zirconia restorations at 1 year (0%). The technical complication rate was 3.7%, with 7.7% complications among the lithium-disilicate restorations and no differences between the two materials (p = .558). At 1-year follow-up, mean Bleeding on Probing (BOP) was higher at implants (0.27 ± 0.3) than adjacent teeth (0.17 ± 0.18) (p = .046) with no differences between materials (p = .36). Differences in pocket probing depth (PPD) between implants and adjacent teeth were significant (p < .01). Jemt Index improved significantly from BL to 1-y-follow-up (p < .001). CONCLUSIONS: Preliminary results were good, suggesting that the ceramic type does not impact technical and biologic parameters.


Assuntos
Produtos Biológicos , Titânio , Humanos , Projetos Piloto , Lítio , Falha de Restauração Dentária , Porcelana Dentária , Coroas , Zircônio , Cerâmica , Dente Suporte
11.
Clin Oral Implants Res ; 34 Suppl 25: 22-37, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35332952

RESUMO

AIM: To evaluate outcome measures, methods of assessment, and analysis in clinical studies on fixed single- and multiple-unit implant restorations. MATERIALS AND METHODS: Three independent electronic database searches (MEDLINE, EMBASE, and Cochrane) were done to identify prospective and retrospective clinical studies published from January 2011 up to June 2021 with ≥20 patients and minimum 1-year follow-up period on technical and clinical outcomes of implant-supported single crowns (SCs) and partial fixed dental prostheses (P-FDPs). An entire data extraction was performed to identify primarily the most reported outcome measures and later to define the choice of assessment methods of those outcome measures. The outcomes were analysed descriptively, and the strength of association was evaluated using the Pearson chi-square test (p ≤ .05). RESULTS: In a total 531 studies, 368 on SCs (69.3%), 70 on P-FDPs (13.1%), and 93 on both restoration types (17.5%) were included; 56.3% of all studies did not clearly define a primary outcome. The most frequent primary outcome was marginal bone level (MBL) (55.2%) followed by implant survival (5.3%), professional aesthetic evaluation (3.4%), and technical complications (2.1%). Peri-implant indices were the most reported secondary outcome (55.1%), followed by implant survival (39.9%), MBL (36%), and implant success (26.4%). Prosthetic failure (seven studies [3.9%]) was one of the least reported outcome measures. CONCLUSIONS: Outcome measures and their assessment methods showed high heterogeneity among studies. Primary outcomes were not often defined clearly, and the most frequently selected primary outcome was marginal bone loss. Prosthetic outcomes, implant survival, and patient-related outcomes were only infrequently reported.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Estudos Prospectivos , Estudos Retrospectivos , Coroas , Avaliação de Resultados em Cuidados de Saúde , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Prótese Parcial Fixa
12.
Clin Oral Implants Res ; 34(9): 911-919, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37340530

RESUMO

OBJECTIVES: To assess survival rates and compare technical, biological, and esthetic outcomes of customized zirconia and titanium abutments at 13 years post loading. MATERIALS AND METHODS: Initially, 22 patients with 40 implants in posterior regions were included. The sites were randomly assigned to 20 customized zirconia abutments with cemented all ceramic crowns (ACC) and 20 customized titanium abutments with cemented metal ceramic crowns (MCC). At a mean follow-up of 13.4 years, patients were examined and implants/restorations assessed for survival and technical complications, as well as biological and esthetic outcomes (pocket probing depth [PPD], bleeding on probing [BOP], plaque control record [PCR], bone level [BL], papilla index [PAP], mucosal thickness, and recession (distance of the margo mucosae [MM]/margo gingivae MG)). Descriptive analyses were performed for all outcome measures. RESULTS: Fifteen patients with 21 abutments (13 zirconia, 8 titanium) were examined at 13 years. The drop-out rate was 25% (patient level). The technical survival rate of the abutments was 100%. The survival rate on the restorative level (crowns) was 100%. The assessed biological outcomes (PPD, PCR, BOP, BL) and esthetic outcomes (MG, PAP) were similar. CONCLUSIONS: Zirconia and titanium abutments supporting single implant-borne restorations rendered a high survival rate and minimal differences in terms of technical, biological, and esthetic outcomes at 13 years of follow-up.


Assuntos
Implantes Dentários para Um Único Dente , Titânio , Humanos , Cerâmica , Seguimentos , Dente Suporte , Falha de Restauração Dentária , Coroas , Zircônio
13.
Artigo em Inglês | MEDLINE | ID: mdl-37929698

RESUMO

AIM: This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs). MATERIALS AND METHODS: Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05). RESULTS: All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05). CONCLUSION: The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.

14.
Clin Oral Implants Res ; 34 Suppl 26: 86-103, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750526

RESUMO

OBJECTIVE: The objectives of the study were to assess the survival, failure, and technical complication rates of implant-supported fixed dental prosthesis (iFDPs) with pontic or splinted crown (iSp C) designs in the posterior area and compare the influence of prosthetic materials and prosthetic design on the outcomes. METHODS: Electronic and manual searches were performed to identify randomized-, prospective-, and retrospective clinical trials with follow-up time of ≥12 months, evaluating the clinical outcomes of posterior iFDPs with pontic or iSp Cs. Survival and complication rates were analyzed using robust Poisson's regression models. RESULTS: Thirty-two studies reporting on 42 study arms were included in the present systematic review. The meta-analysis of the included studies indicated estimated 3-year survival rates of 98.3% (95%CI: 95.6-99.3%) for porcelain-fused-to-metal (PFM) iFDPs, 97.5% (95%CI: 95.5-98.7%) for veneered zirconia (Zr) iFDPs with pontic, 98.9% (95%CI: 96.8-99.6%) for monolithic or micro-veneered zirconia iFDPs with pontic, and 97.0% (95%CI: 84.8-99.9%) for lithium disilicate iFDPs with pontics. The survival rates for different material combination showed no statistically significant differences. Veneered restorations, overall, showed significantly (p < .01) higher ceramic fracture and chipping rates compared with monolithic restorations. Furthermore, there was no significant difference in survival rates (98.3% [95%CI: 95.6-99.3%] vs. 99.1% [95%CI: 97.6-99.7%]) and overall complication rates between PFM iFDPs with pontic and PFM iSp Cs. CONCLUSIONS: Based on the data identified by this systematic review, PFM, veneered Zr, and monolithic Zr iFDPs with pontic and iSp Cs showed similarly high short-term survival rates in the posterior area. Veneered restorations exhibit ceramic chipping more often than monolithic restorations, with the highest fracture rate reported for veneered Zr iFDPs.


Assuntos
Planejamento de Prótese Dentária , Falha de Restauração Dentária , Estudos Prospectivos , Estudos Retrospectivos , Porcelana Dentária , Cerâmica , Zircônio , Coroas , Prótese Dentária Fixada por Implante
15.
Clin Oral Implants Res ; 34(9): 999-1013, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37403575

RESUMO

OBJECTIVES: To test whether soft tissue volume augmentation using a collagen matrix (VCMX) leads to noninferior results in terms of gain of mucosal thickness at single implant sites, compared to connective tissue grafts (SCTG). METHODS: The study was designed as a multi-center randomized controlled clinical trial. Subjects in need of soft tissue volume augmentation at single tooth implant sites were consecutively recruited at nine centers. The deficient mucosal thickness at the implant sites (one per patient) was augmented by applying either a VCMX or a SCTG. Patients were examined at 120 days (abutment connection = primary endpoint), 180 days (final restoration), and 360 days (1-year after insertion of the final restoration). Outcome measures included: transmucosal probing of the mucosal thickness (crestal = primary outcome), profilometric measurements of the tissue volume, and patient-reported outcome measures (PROMs). RESULTS: Out of the 88 patients, 79 attended the one-year follow-up. The median increase of the crestal mucosal thickness between pre-augmentation and 120 days was 0.3 ± 2.1 mm in the VCMX group and 0.8 ± 1.6 mm in the SCTG group (p = .455). Non-inferiority of the VCMX compared to the SCTG was not observed. The respective numbers at the buccal aspect amounted to 0.9 ± 2.0 mm (VCMX) and 1.1 ± 1.4 mm (SCTG; p = .431). PROMs including pain perception favored the VCMX group. CONCLUSION: It remains inconclusive whether soft tissue augmentation using a VCMX is noninferior to SCTG in terms of crestal mucosal thickening at single implant sites. However, the use of collagen matrices favors PROMs especially pain perception, while achieving similar buccal volume gains along with comparable clinical and aesthetic parameters to SCTG.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Gengiva/cirurgia , Colágeno/uso terapêutico , Tecido Conjuntivo/transplante , Resultado do Tratamento
16.
Clin Oral Implants Res ; 34 Suppl 25: 4-21, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37232121

RESUMO

AIM: Lack of consistently reported outcomes limits progress in evidence-based implant dentistry and quality of care. The objective of this initiative was to develop a core outcome set (COS) and measurements for implant dentistry clinical trials (ID-COSM). MATERIALS AND METHODS: This Core Outcome Measures in Effectiveness Trials (COMET)-registered international initiative comprised six steps over 24 months: (i) systematic reviews of outcomes reported in the last 10 years; (ii) international patient focus groups; (iii) a Delphi project with a broad range of stakeholders (care providers, clinical researchers, methodologists, patients and industry representatives); (iv) expert group discussions organizing the outcomes in domains using a theoretical framework and identifying the COSs; (v) identification of valid measurement systems to capture the different domains and (vi) final consensus and formal approval involving experts and patients. The methods were modified from the best practice approach following the Outcome Measures in Rheumatoid Arthritis Clinical Trial and COMET manuals. RESULTS: The systematic reviews and patient focus groups identified 754 (665 + 89, respectively) relevant outcome measures. After elimination of redundancies and duplicates, 111 were formally assessed in the Delphi project. By applying pre-specified filters, the Delphi process identified 22 essential outcomes. These were reduced to 13 after aggregating alternative assessments of the same features. The expert committee organized them into four core outcome areas: (i) pathophysiology, (ii) implant/prosthesis lifespan, (iii) life impact and (iv) access to care. In each area, core outcomes were identified to capture both the benefits and harms of therapy. Mandatory outcome domains included assessment of surgical morbidity and complications, peri-implant tissue health status, intervention-related adverse events, complication-free survival and overall patient satisfaction and comfort. Outcomes deemed mandatory in specific circumstances comprised function (mastication, speech, aesthetics and denture retention), quality of life, effort for treatment and maintenance and cost effectiveness. Specialized COSs were identified for bone and soft-tissue augmentation procedures. The validity of measurement instruments ranged from international consensus (peri-implant tissue health status) to early identification of important outcomes (patient-reported outcomes identified by the focus groups). CONCLUSIONS: The ID-COSM initiative reached a consensus on a core set of mandatory outcomes for clinical trials in implant dentistry and/or soft tissue/bone augmentation. Adoption in future protocols and reporting on the respective domain areas by currently ongoing trials will contribute to improving evidence-informed implant dentistry and quality of care.


Assuntos
Implantes Dentários , Projetos de Pesquisa , Humanos , Resultado do Tratamento , Consenso , Qualidade de Vida , Avaliação de Resultados em Cuidados de Saúde , Técnica Delphi
17.
J Esthet Restor Dent ; 35(1): 262-269, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36478351

RESUMO

OBJECTIVE: This study aims to validate the standardized procedure for designing soft tissue substitutes (STS) adapted to optimally fit single-tooth defects in the anterior jaws and double-tooth defects in the posterior jaw and to compare mathematically modeled average shapes. MATERIALS AND METHODS: Casts from 35 patients with 17 single-tooth defects in anterior region and 21 double-tooth defects in posterior region were scanned. STS were designed and sectioned in 3D slices meshes. Thickness values were documented respecting mesial-distal and buccal-lingual orientations. Graphs were embedded into images, and hierarchical clustering was applied to group STS according to shape and thickness. RESULTS: STS clustered into two groups per defect type. For anterior single defects, STS (n = 4) were either a small and thin oval: 7 mm buccal-lingual, 4-5 mm mesial-distal direction and 1.1-1.5 mm thick or a larger oval (n = 13): 9 mm buccal-lingual, 5-7 mm mesial-distal and 1.6 m thick. For posterior double tooth defects, STS (n = 10) were either narrow, long and thick: 6-7 mm buccal-lingual, 16-20 mm mesial-distal and 2.2 thick or a wide, thinner rectangle (n = 11): 9-11 mm buccal-lingual, 12-14 mm mesial-distal and 1.1-1.5 mm thick. CONCLUSIONS: The study validated the standardized digital method to design grafts for soft tissue volume augmentation and identified four average shapes for anterior single-tooth and posterior double-tooth soft tissue defects. CLINICAL SIGNIFICANCE: We developed and validated a standardized digital method to design an optimal geometrical shape of a soft tissue substitute for oral volume augmentation and combined it with mathematical modeling to identify average shapes for single-interior, and double-posterior tooth defects. The identified average shapes offer the possibility to produce better-fitted xenografts or synthetic STS blocks requiring minimal chair-side adaptation leading to reduced clinical time and patient discomfort and potentially improving soft tissue volume augmentation outcomes.


Assuntos
Dentes Fusionados , Dente , Humanos , Engenharia Tecidual
18.
J Prosthet Dent ; 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37537105

RESUMO

STATEMENT OF PROBLEM: The absence of fixed reference points can affect the trueness of complete-arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete-arch digital implant scans is still unclear. PURPOSE: The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete-arch digital implant scans with 5 intraoral scanners (IOSs). MATERIAL AND METHODS: Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (α=.05). RESULTS: The mean ±standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 ±8 µm, 53 ±7 µm, and 49 ±11 µm, respectively, with no statistically significant differences (P=.06). Significant differences were found for the IOSs used with each technique (P<.001). Primescan (27 ±4 µm cIOSs; 28 ±3 µm sIOSs; 31 ±3 µm AL-IOSs) showed significantly higher trueness than iTero 5D (47 ±5 µm cIOSs; 47 ±4 µm sIOSs; 50 ±6 µm AL-IOSs) (P=.002) and TRIOS 4 (93 ±18 µm cIOSs; 76 ±18 µm sIOSs; 107 ±13 µm AL-IOSs) (P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan (P=.348 and P=.059, respectively). CONCLUSIONS: The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete-arch digital implant scans.

19.
J Prosthodont ; 32(3): 234-243, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35434903

RESUMO

PURPOSE: To investigate the survival and mechanical properties of 3-unit interim fixed dental prostheses (FDPs) made with additive manufacturing (AM) technology compared to milled and conventional manual fabrication. MATERIALS AND METHODS: Sixty 3-unit interim FDPs replacing the first left mandibular molar were divided in 6 groups (n = 10): manual (Man) (Protemp 4), milled (Mil) (Telio-CAD Multi), and 4 additive manufacturing (AM) groups were subdivided into 4 AM technology subgroups: direct light positioning (DLP) (Rapidshape P30 [RS]), and stereolitography (SLA) (Formlabs 2 [FL]) and the type of printed interim polymer (P Pro C&B [St] and SHERAprint-cb [Sh]) (RS-St, RS-Sh, FL-St, and FL-Sh). Survival and complications were assessed after thermomechanical aging. The surviving samples were tested for fracture resistance. Kaplan-Meier test followed by log-rank test to show differences between groups was used to calculate the survival and complication rates. For fracture strength, one-way ANOVA and Tukey-b post hoc test were used to compare groups. Descriptive statistics was used for failure modes and Pearson chi-square to compare groups (α = 0.05). RESULTS: Survival rates among groups varied from 100% (Man, Mil and FL-Sh), 70% (FL-St), 50% (RS-Sh), and 20% (RS-Sh) (p < 0.001), respectively. Additional events were observed in 50% to 80% in FL-St, RS-St, and RS-Sh groups (p < 0.001). Man, FL-St, and RS-S showed lower mean static load resistance (p < 0.001). Fracture through the connector between tooth 35 and the pontic was the most prevalent type of failure. CONCLUSION: The manufacturing method, type of resin, and the printing mode had a significant influence on the mechanical properties of AM interim 3-unit FDPs.


Assuntos
Desenho Assistido por Computador , Falha de Restauração Dentária , Humanos , Polímeros , Teste de Materiais , Análise do Estresse Dentário
20.
J Prosthodont ; 32(S2): 135-141, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37837217

RESUMO

PURPOSE: To evaluate the effect of operator age on the scan accuracy (trueness and precision) of inexperienced operators when compared with experienced operators, and how training, intraoral scanner (IOS), and software version affect scan accuracy. MATERIAL AND METHODS: Thirty-four operators were sorted into groups: G1 (operators <25 years old, no experience), G2 (operators >40 years old, no experience), and G3 (experienced IOS operators). They conducted partial-arch scans before and after a 4-session training with two IOSs (Trios 3 and True Definition) and two software versions. These scans were compared with the reference scans obtained from conventional impressions and a laboratory scanner (IScan D103i) to evaluate trueness (mean root mean square values) and precision (standard deviation of root mean square values) with a software program (Geomagic Control X). Kruskal-Wallis and post-hoc Dunn's tests were used to evaluate the effect of age on the scan accuracy of inexperienced groups when compared with experienced operators, while the effect of training, IOS, and software version on scan accuracy was evaluated with Wilcoxon or Mann-Whitney U tests (α = 0.05). RESULTS: Before training, G1 and G2 scans had similar accuracy (p ≥ 0.065). After training, G1 scans had higher accuracy when IOS data was pooled and had higher precision with TD (p ≤ 0.004). Training increased the scan accuracy (p < 0.001), while newer software increased the trueness of inexperienced operator scans (p = 0.015). CONCLUSIONS: Age affected the scan accuracy of inexperienced operators after training, indicating that extended training may be required for older operators. Training increased the scan accuracy, and newer software increased the trueness of inexperienced operator scans.


Assuntos
Técnica de Moldagem Odontológica , Imageamento Tridimensional , Modelos Dentários , Desenho Assistido por Computador , Software , Arco Dental
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA