Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Br J Neurosurg ; 37(3): 469-472, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31580167

RESUMO

Harvesting the superficial temporal artery (STA) is the first difficult step in extracranial-intracranial bypass surgery. There are various methods and instruments for harvesting the STA. We used the Lone Star (LS) retractor system for harvesting the STA. The LS retractor system is used in other surgical specialties. The LS retractor system consists of the retractor ring (14.1 cm × 14.1 cm) and elastic stays (5-mm sharp hook). The retractor ring can be used to adjust to the operative field. Retracting the loose connective tissue around the STA by the elastic stays can make harvesting the STA easy and safe. After harvesting the STA, retracting the skin and muscle by the elastic stays is useful for hemostasis during intracranial surgery and anastomosis. We used the LS retractor system in 26 consecutive patients to perform STA-MCA anastomosis between November 2015 and August 2018. All STAs were harvested without complications or injuries. The LS retractor system is a safe and useful method for harvesting the STA.


Assuntos
Revascularização Cerebral , Humanos , Revascularização Cerebral/métodos , Artérias Temporais/cirurgia , Microcirurgia/métodos , Anastomose Cirúrgica , Artéria Cerebral Média/cirurgia
2.
Radiol Med ; 128(10): 1262-1270, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37658197

RESUMO

PURPOSE: Follow-up examinations after flow diverter (FD) treatment for cerebral aneurysms typically involve magnetic resonance imaging (MRI) or digital subtraction angiography (DSA). However, MRI is prone to vascular defects due to metal artifacts from FD, and DSA carries a risk of ischemic complications. In the context of computed tomography angiography (CTA), this study compares the efficacy of ultra-high-resolution CT (UHRCT) and novel reconstruction techniques, such as model-based iterative reconstruction (MBIR), against conventional methods such as filtered back projection (FBP) and hybrid iterative reconstruction (IR), to determine if they are a viable alternative to DSA in clinical settings. MATERIALS AND METHODS: A phantom study was conducted with the full-width half-maximum considered as the FD thickness. This study compared three reconstruction methods: MBIR, FBP, and hybrid IR. A clinical study was also conducted with 21 patients who underwent follow-up CTA after FD treatment. The FD's visibility was assessed using a 4-point scale in FBP, hybrid IR, and MBIR compared to cone-beam CT (CBCT) with angiographic systems. RESULTS: In the phantom study, FBP, hybrid IR, and MBIR visualized thinner FD thicknesses and improved detail rendering in that order. MBIR proved to be significantly superior in both the phantom and clinical study. CONCLUSION: UHRCT with MBIR is highly effective for follow-up evaluations after FD treatment and may become the first-choice modality in the future.


Assuntos
Angiografia por Tomografia Computadorizada , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Seguimentos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia Digital , Algoritmos , Doses de Radiação
3.
J Orthop Sci ; 27(4): 751-759, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33966957

RESUMO

BACKGROUND: Proper identification of lumbosacral transitional vertebrae (LSTV) is important to characterize the relationship between the transitional segment and adjacent levels. Classical classification schemes are inaccurate with respect to the whole spine. We propose a precise vertebral numbering method and investigated the relationship between LSTV and whole-body sagittal alignment. METHODS: A total of 291 healthy adult volunteers with no history of spinal disease were evaluated with biplanar slot scanning full body stereoradiography to determine the prevalence of LSTV. Vertebrae were counted from the first cervical vertebra using both coronal and sagittal plane images. We then investigated the influence of LSTV on whole-body sagittal alignment in 279 participants. Whole-body key parameters descriptive statistics were compared among groups according to the number of vertebrae (L4, L5, and L6). Statistical analysis was performed between normal and LSTV cases using the Steel-Dwass analysis. RESULTS: Of the 291 subjects, 14 (4.8%) had 23 vertebrae and 16 (5.5%) had 25 vertebrae. Eleven (3.8%) had Th11, 3 (1.0%) had L4, and 1 (0.3%) had Th11 + L6, 16 (5.5%) had L6. Compared with the normal group, the sacral base in relation to the pelvis was higher in the L4 group and lower in the L6 group. The C2-C7 angle and lumbar lordosis (LL) were increased in both the L4 and L6 groups. All remaining parameters were decreased in the L4 group and increased in the L6 group. The relationship between LL and PI was similar in the normal and LSTV groups, despite the difference in the sacral base location. CONCLUSIONS: We propose a precise method for numbering the vertebrae using coronal and sagittal full body images. The spinopelvic parameters of the LSTV population significantly differed from those in the normal spine population due to differences in the sacral base location.


Assuntos
Lordose , Vértebras Lombares , Adulto , Voluntários Saudáveis , Humanos , Lordose/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral/diagnóstico por imagem , Sacro/diagnóstico por imagem
4.
Neuropathology ; 41(4): 315-323, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34258808

RESUMO

Intracranial myxoid mesenchymal tumor (IMMT) is a recently described, extremely rare group of neoplasms characterized by fusions between the female-expressed transcript (FET) family genes and the cAMP response element-binding protein (CREB) family genes. Controversy persists regarding whether the tumor is a myxoid variant of angiomatoid fibrous histiocytoma or a completely distinct clinicopathological entity. Here, we report a case of IMMT arising in the posterior fossa in a 65-year-old woman with a history of breast cancer. We performed total removal of the tumor, which histologically demonstrated features characteristic of IMMT but also bore a partial resemblance to conventional angiomatoid fibrous histiocytoma. Immunohistochemically, tumor cells were diffusely positive for desmin, vimentin, cluster of differentiation (CD) 99 (CD99), glucose transporter-1, and cytokeratin (CK) 8/18 (CK8/18), and focally positive for CK7, epithelial membrane antigen, mucin 4, anaplastic lymphoma kinase, calponin, and CD68. Molecular genetic analysis revealed a fusion between the Ewing sarcoma breakpoint region 1 (EWSR1) gene (EWSR1) and the cAMP-responsive element modulator (CREM) gene (CREM) called EWSR1:CREM fusion, which confirmed the diagnosis. The overlap of the pathological features of IMMTs and angiomatoid fibrous histiocytomas may support the recent theory that these tumors are two manifestations of a single entity. Moreover, our study indicated the broad spectrum of immunohistochemical phenotypes of these tumors, which should be noted during diagnosis. Further studies are needed to elucidate the histopathological concept, long-term prognosis, optimal treatment strategy, and factors associated with the prognosis and therapeutic options of this condition.


Assuntos
Neoplasias Encefálicas , Histiocitoma Fibroso Maligno , Adulto , Idoso , Biomarcadores Tumorais/genética , Neoplasias Encefálicas/genética , Modulador de Elemento de Resposta do AMP Cíclico/genética , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico , Feminino , Fusão Gênica , Humanos , Proteína EWS de Ligação a RNA/genética
5.
J Bone Miner Metab ; 38(4): 533-543, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32002681

RESUMO

INTRODUCTION: Cortical thickness of the femoral diaphysis is assumed to be a preferred parameter in the assessment of the structural adaptation by mechanical use and biological factors. This study aimed to investigate the age- and sex-specific characteristics in cortical thickness of the femoral diaphysis between young and elderly non-obese people. MATERIALS AND METHODS: This study investigated 34 young subjects (21 men and 13 women; mean age: 27 ± 8 years) and 52 elderly subjects (29 men and 23 women; mean age: 70 ± 6 years). Three-dimensional (3D) cortical thickness of the femoral diaphysis was automatically calculated for 5000-8000 measurement points using the high-resolution cortical thickness measurement from clinical CT data. In 12 assessment regions created by combining three heights (proximal, central, and distal diaphysis) and four areas of the axial plane at 90° (medial, anterior, lateral, and posterior areas) in the femoral coordinate system, the standardized thickness was assessed using the femoral length. RESULTS: As per the trends, (1) there were no differences in medial and lateral thicknesses, while the posterior thickness was greater than the anterior thickness, (2) the thickness in men was higher than that in women, and (3) the thickness in young subjects was higher than that in elderly subjects. CONCLUSIONS: The results of this study are of clinical relevance as reference points to clarify the causes of various pathological conditions for diseases of the lower extremities.


Assuntos
Osso Cortical/anatomia & histologia , Diáfises/anatomia & histologia , Fêmur/anatomia & histologia , Caracteres Sexuais , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Osso Cortical/diagnóstico por imagem , Diáfises/diagnóstico por imagem , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Eur Spine J ; 29(3): 446-454, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31444610

RESUMO

PURPOSE: To investigate the relationship between relative location of the sacral base and spinal alignment in standing healthy adult volunteers. METHODS: One hundred seventy-two volunteers (men = 83, mean age = 39.3 years [20-70], women = 89, mean age = 39.6 years [20-62]) with no history of spinal disease were imaged using a low-dose biplanar slot-scanning 3D X-ray imaging system. A circle was drawn around three points: cranial vertex of the iliac crest (A), caudal vertex of the ischium (B), and anterior vertex of the pubis. Pelvic height (PH) was defined as the diameter (A-B). A tangent line perpendicular to PH (C) was drawn by passing through (A). Sacral height (SH) was defined as the distance between (C) and the center of the sacral base parallel to PH. Relative SH (rSH) was calculated as SH/PH × 100. RESULTS: Mean (SD) rSH was 18.3 ± 3.2 (men 20.0 ± 2.9, women 16.7 ± 2.6). rSH significantly positively correlated with thoracic kyphosis (r = 0.20, p < 0.05), lumbar lordosis (r = 0.28, p < 0.05), pelvic incidence (r = 0.28, p < 0.05), and sacral slope (r = 0.32, p < 0.0001), and significantly negatively correlated with pelvic thickness (r = - 0.66, p < 0.0001). rSH did not correlate with pelvic tilt. CONCLUSION: The center of the sacral base is normally located 3.8 ± 0.8 cm caudal to the cranial vertex of the iliac crest. The sacral base was located more caudally in men than in women, regardless of age. The more caudal the sacral base, the angle of the spino-pelvic parameters (TK, LL, PI, SS) progressively increases along with a decrease in the sacro-acetabular distance (Pth). Pelvic tilt did not correlate with the location of the sacrum.


Assuntos
Pelve/fisiologia , Postura/fisiologia , Sacro/fisiologia , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Radiografia , Sacro/diagnóstico por imagem , Adulto Jovem
9.
Neuroradiology ; 59(3): 231-235, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255903

RESUMO

PURPOSE: The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA). METHODS: Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD1) and the standard deviation at the common carotid artery that was not affected by the artifact (SD2). We calculated the artifact index (AI) as follows: AI = [(SD1)2 - (SD2)2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis. RESULTS: MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778). CONCLUSIONS: MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Prótese Dentária , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
J Orthop Sci ; 22(3): 501-505, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28139346

RESUMO

INTRODUCTION: The relative torsional angle of the distal tibia is dependent on a deformity of the proximal tibia, and it is a commonly used torsional parameter to describe deformities of the tibia; however, this parameter cannot show the location and direction of the torsional deformity in the entire tibia. This study aimed to identify the detailed deformity in the entire tibia via a coordinate system based on the diaphysis of the tibia by comparing varus osteoarthritic knees to healthy knees. METHODS: In total, 61 limbs in 58 healthy subjects (age: 54 ± 18 years) and 55 limbs in 50 varus osteoarthritis (OA) subjects (age: 72 ± 7 years) were evaluated. The original coordinate system based on anatomic points only from the tibial diaphysis was established. The evaluation parameters were 1) the relative torsion in the distal tibia to the proximal tibia, 2) the proximal tibial torsion relative to the tibial diaphysis, and 3) the distal tibial torsion relative to the tibial diaphysis. RESULTS: The relative torsion in the distal tibia to the proximal tibia showed external torsion in both groups, while the external torsion was lower in the OA group than in the healthy group (p < 0.0001). The proximal tibial torsion relative to the tibial diaphysis had a higher external torsion in the OA group (p = 0.012), and the distal tibial torsion relative to the tibial diaphysis had a higher internal torsion in the OA group (p = 0.004) in comparison to the healthy group. CONCLUSION: The reverse torsional deformity, showing a higher external torsion in the proximal tibia and a higher internal torsion in the distal tibia, occurred independently in the OA group in comparison to the healthy group. Clinically, this finding may prove to be a pathogenic factor in varus osteoarthritic knees. LEVEL OF EVIDENCE: Level Ⅲ.


Assuntos
Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/etiologia , Idoso , Diáfises/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/complicações , Fatores de Tempo , Anormalidade Torcional/diagnóstico
11.
J Stroke Cerebrovasc Dis ; 26(7): 1457-1461, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28385516

RESUMO

BACKGROUND: The congestion of spin-labeled blood at large-vessel occlusion can present as hyperintense signals on perfusion magnetic resonance imaging with 3-dimensional pseudo-continuous arterial spin labeling (proximal bright vessel sign). The purpose of this study was to clarify the difference between proximal bright vessel sign and susceptibility vessel sign in acute cardioembolic cerebral infarction. METHODS: Forty-two patients with cardioembolic cerebral infarction in the anterior circulation territory underwent magnetic resonance imaging including diffusion-weighted imaging, 3-dimensional pseudo-continuous arterial spin labeling perfusion magnetic resonance imaging, T2*-weighted imaging, and 3-dimensional time-of-flight magnetic resonance angiography using a 3-T magnetic resonance scanner. Visual assessments of proximal bright vessel sign and the susceptibility vessel sign were performed by consensus of 2 experienced neuroradiologists. The relationship between these signs and the occlusion site of magnetic resonance angiography was also investigated. RESULTS: Among 42 patients with cardioembolic cerebral infarction, 24 patients showed proximal bright vessel sign (57.1%) and 25 showed susceptibility vessel sign (59.5%). There were 19 cases of proximal bright vessel sign and susceptibility vessel sign-clear, 12 cases of proximal bright vessel sign and susceptibility vessel sign-unclear, and 11 mismatched cases. Four out of 6 patients with proximal bright vessel sign-unclear and susceptibility vessel sign-clear showed distal middle cerebral artery occlusion, and 2 out of 5 patients with proximal bright vessel sign-clear and susceptibility vessel sign-unclear showed no occlusion on magnetic resonance angiography. CONCLUSIONS: Proximal bright vessel sign is almost compatible with susceptibility vessel sign in patients with cardioembolic cerebral infarction.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Embolia/complicações , Cardiopatias/complicações , Embolia Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Idoso , Idoso de 80 Anos ou mais , Infarto Cerebral/etiologia , Embolia/diagnóstico , Feminino , Cardiopatias/diagnóstico , Humanos , Interpretação de Imagem Assistida por Computador , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
J Stroke Cerebrovasc Dis ; 26(7): 1535-1540, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28411037

RESUMO

BACKGROUND: The present study compared the applicability of computed tomography carotid plaque imaging using effective Z maps with gemstone spectral imaging (GSI) to that of magnetic resonance plaque imaging using 3-dimensional time-of-flight magnetic resonance angiography. METHODS: Stenosis was assessed in 18 carotid arteries of 14 patients, and the effective Z values of noncalcified carotid plaques were compared with the signal intensities of magnetic resonance angiography. RESULTS: It was found that the effective Z value of noncalcified carotid plaques was significantly lower for a group with high signal intensity than for a group with low signal intensity on magnetic resonance angiography (P <.001). The area under the receiver operating characteristic curve of effective Z values was .975, and the presumed cutoff effective Z value required to discriminate low and high intensity plaques on magnetic resonance angiography was 7.83. CONCLUSIONS: The effective Z value generated by GSI is a useful parameter to detect vulnerable carotid plaque materials.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética , Placa Aterosclerótica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Clin Calcium ; 26(1): 81-91, 2016 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-26728534

RESUMO

Nanoindentation has been applied in recent years to measure the mechanical properties of bone tissues at a microscopic scale, overcoming the limitations of traditional mechanical testing techniques for small samples. This method is precise and accurate and appears well suited for measuring mechanical properties in bone. Dynamic nanoindentation is also a promising method of measuring the viscoelastic properties of bone tissues at smaller length and load scales than allowed by other testing methods, thus allowing individual constituents and local regions of inhomogeneous tissues to be characterized individually. This article describes our nanoindentation studies of bone tissues with recent studies.


Assuntos
Fenômenos Biomecânicos/fisiologia , Osso e Ossos/fisiologia , Teste de Materiais/métodos , Nanotecnologia/métodos , Animais , Densidade Óssea , Elasticidade , Masculino , Teste de Materiais/instrumentação , Nanotecnologia/instrumentação , Ratos , Ratos Sprague-Dawley , Viscosidade
14.
Neuroradiology ; 57(9): 889-95, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25981057

RESUMO

INTRODUCTION: The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). METHODS: We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. RESULTS: The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). CONCLUSION: Effective Z maps generated by GSI can detect vulnerable carotid plaque materials.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Neuroradiology ; 56(11): 947-53, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25117504

RESUMO

INTRODUCTION: Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. METHODS: In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. RESULTS: In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. CONCLUSION: MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS.


Assuntos
Angiografia , Artefatos , Estenose das Carótidas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Imagens de Fantasmas , Estudos Retrospectivos
16.
Acta Radiol ; 55(8): 1015-23, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24215905

RESUMO

BACKGROUND: Recently, a newly developed fast-kV switching dual energy CT scanner with a gemstone detector generates virtual high keV images as monochromatic imaging (MI). Each MI can be reconstructed by metal artifact reduction software (MARS) to reduce metal artifact. PURPOSE: To evaluate the degree of metal artifacts reduction and vessel visualization around the platinum coils using dual energy CT with MARS. MATERIAL AND METHODS: Dual energy CT was performed using a Discovery CT750 HD scanner (GE Healthcare, Milwaukee, WI, USA). In a phantom study, we measured the mean standard deviation within regions of interest around a 10-mm-diameter platinum coil mass on MI with and without MARS. Thirteen patients who underwent CTA after endovascular embolization for cerebral aneurysm with platinum coils were included in a clinical study. We visually assessed the arteries around the platinum coil mass on MI with and without MARS. RESULTS: Each standard deviation near the coil mass on MI with MARS was significantly lower than that without MARS in a phantom study. On CTA of a clinical study, better visibility of neighboring arteries was obtained in 11 of 13 patients on MI with MARS compared to without MARS due to metal artifact reduction. CONCLUSION: Dual energy CT with MARS reduces metal artifact of platinum coils, resulting in favorable vessel visualization around the coil mass on CTA after embolization.


Assuntos
Artefatos , Artérias Cerebrais/diagnóstico por imagem , Embolização Terapêutica/métodos , Processamento de Imagem Assistida por Computador/métodos , Aneurisma Intracraniano/terapia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Basilar/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Ácido Iopanoico/análogos & derivados , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Platina , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Software
17.
Dent Mater J ; 43(1): 44-51, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38044144

RESUMO

Using finite-element analysis, we aimed to determine the center of resistance (CRes) of the maxillary canine for setting orthodontic forces. The inclination of the canine was measured by first loading from the mesial to the distal side of the mesial root surface, then the position and direction of the load that minimized the inclination were investigated. The CRes was defined as the set of midpoints of the minimum distances between two inclination lines. Twenty-one CRes values were calculated from a set of seven lines. These CRes data were then aggregated as a 95% confidence ellipsoid of width 0.170×0.016×0.009 mm with center points 4.269, 0.224, and 4.315 mm in the apical, mesial, and lingual directions from the origin, respectively. Further studies are required to effectively apply the CRes identified in this study to clinical applications.


Assuntos
Dente Canino , Técnicas de Movimentação Dentária , Técnicas de Movimentação Dentária/métodos , Raiz Dentária , Análise de Elementos Finitos , Maxila , Imageamento Tridimensional/métodos
18.
Porto Biomed J ; 9(3): 256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38903393

RESUMO

We developed two methods for three-dimensional (3D) evaluation of spinal alignment in standing position by image matching between biplanar x-ray images and 3D vertebral models. One used a Slot-Scanning 3D x-ray Imager (sterEOS) to obtain biplanar x-ray images, and the other used a conventional x-ray system and a rotating table. The 3D vertebral model was constructed from the CT scan data. The spatial position of the vertebral model was determined by minimizing the contour difference between the projected image of the model and the biplanar x-ray images. Verification experiments were conducted using a torso phantom. The relative positions of the upper vertebrae to the lowest vertebrae of the cervical, thoracic, and lumbar vertebrae were evaluated. The mean, standard deviation, and mean square error of the relative position were less than 1° and 1 mm in all cases for sterEOS. The maximum mean squared errors of the conventional x-ray system and the rotating table were 0.7° and 0.4 mm for the cervical spine, 1.0° and 1.2 mm for the thoracic spine, and 1.1° and 1.2 mm for the lumbar spine. Therefore, both methods could be useful for evaluating the spinal alignment in standing position.

19.
J Biomech Eng ; 135(8): 81002, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23719832

RESUMO

While various factors have been assumed to affect knee joint biomechanics, few data have been reported on the function of the extensor mechanism in deep flexion of the knee. This study analyzed the patellofemoral joint contact kinematics and the ratio of the quadriceps and patellar tendon forces in living subjects when they performed a single leg lunge up to 150 deg of flexion. The data revealed that in the proximal-distal direction, the patellofemoral articular contact points were in the central one-third of the patellar cartilage. Beyond 90 deg of flexion, the contact points moved towards the medial-lateral edges of the patellar surface. At low flexion angles, the patellar tendon and quadriceps force ratio was approximately 1.0 but reduced to about 0.7 after 60 deg of knee flexion, implying that the patella tendon carries lower loads than the quadriceps. These data may be valuable for improvement of contemporary surgical treatments of diseased knees that are aimed to achieve deep knee flexion.


Assuntos
Articulação do Joelho/fisiologia , Adulto , Fenômenos Biomecânicos , Engenharia Biomédica , Cartilagem Articular/fisiologia , Feminino , Humanos , Articulação do Joelho/anatomia & histologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Biológicos , Articulação Patelofemoral/anatomia & histologia , Articulação Patelofemoral/fisiologia , Músculo Quadríceps/anatomia & histologia , Músculo Quadríceps/fisiologia , Adulto Jovem
20.
J Phys Ther Sci ; 25(5): 623-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24259816

RESUMO

[Purpose] This study was performed to investigate the histological changes that occur in the periphery of the sciatic nerve in rats undergoing knee immobilization. [Subjects and Methods] 29 male 9-week-old Wistar rats were divided randomly into a control group (C group, n = 7) and an immobilized group (I group, n = 22). The animals in the I group had the left knee joint immobilized in maximal flexion with plaster casts for two weeks. After the experimental period, we obtained cross-sections of tissues from the center of the left thigh, and the periphery of the sciatic nerve was observed under an optical microscope after hematoxylin-eosin staining. [Results] In contrast to the rats of C group, the rats in I group showed adherence between the bundle of nerve fibers and perineurium, as well as thickening of the perineurium. These histological changes were statistically significant. [Conclusions] Immobilization of the knee joints of rats resulted in characteristic histological changes in the connective tissue around the sciatic nerve.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA