Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(5): 984-993, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38486082

RESUMO

INTRODUCTION: Little is known about very early atrial fibrillation (AF) ablation after first AF detection. METHODS: We evaluated patients with AF ablation <4 months from newly diagnosed paroxysmal AF (NEWPaAF) and newly diagnosed persistent AF (NEWPeAF). We compared the two patient populations and compared ablation outcomes to those undergoing later ablation. RESULTS: Ablation was done <4 months from AF diagnosis in 353 patients (135 = paroxysmal, 218 = persistent). Early ablation outcome was best for NEWPaAF versus NEWPeAF for initial (p = 0.030) but not final (p = 0.102) ablation. Despite recent AF diagnosis in both groups, they were clinically quite different. NEWPaAF patients were younger (64.3 ± 13.0 vs. 67.3 ± 10.9, p = 0.0020), failed fewer drugs (0.39 vs. 0.60, p = 0.007), had smaller LA size (4.12 ± 0.58 vs. 4.48 ± 0.59 cm, p < 0.0001), lower BMI (28.8 ± 5.0 vs. 30.3 ± 6.0, p = 0.016), and less CAD (3.7% vs. 11.5%, p = 0.007), cardiomyopathies (2.2% vs. 22.9%, p = 0.0001), hypertension (46.7% vs. 67.4%, p < 0.0001), diabetes (8.1% vs. 17.4%, p = 0.011) and sleep apnea (20.0% vs. 30.3%, p = 0.031). For NEWPaAF, early ablation AF-free outcome was no better than later ablation (p = 0.314). For NEWPeAF, AF-free outcomes were better for early ablation than later ablation (p < 0.0001). Delaying ablation allowed more strokes/TIAs in both AF types (paroxysmal p = 0.014, persistent p < 0.0001). CONCLUSIONS: Patients presenting for early ablation after newly diagnosed persistent AF have more pre-existing comorbidities and worse initial ablation outcomes than patients with NEWPaAF. For NEWPaAF, there was no advantage to early ablation, as long as the AF remained paroxysmal. For NEWPeAF, early ablation gave better outcomes than later ablation and they should undergo early ablation. For both AF types, waiting was associated with more neurologic events, suggesting all patients should consider earlier ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Ablação por Cateter/efeitos adversos , Feminino , Pessoa de Meia-Idade , Fatores de Tempo , Idoso , Fatores de Risco , Resultado do Tratamento , Frequência Cardíaca , Tempo para o Tratamento , Potenciais de Ação , Estudos Retrospectivos
2.
J Cardiovasc Electrophysiol ; 34(4): 1033-1036, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786522

RESUMO

INTRODUCTION: Vascular access is required for most cardiac electrophysiology procedures. Over the past 2 decades, ultrasound guidance has increased in utilization as the primary method for assisting operators in gaining access to cardiac implantable electronic device (CIED) implantation. METHODS: Ultrasound guidance using a technique that includes both short-axis and long-axis views combined with a twisting needle motion after maximal tenting provides an extremely safe and reproducible technique for vascular access for all CIED procedures. RESULTS AND CONCLUSIONS: In this manuscript and accompanying videos, a step-by-step guide is explained for optimal ultrasound-guided visualization and needle maneuver technique to maximize safety and efficiency for vascular access in all CIED procedures.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Ultrassonografia de Intervenção/métodos , Agulhas , Implantação de Prótese
3.
J Cardiovasc Electrophysiol ; 33(1): 117-122, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34674347

RESUMO

INTRODUCTION: Single-center observational studies have shown promising results with fragmented electrogram (FE)-guided ganglionated plexus (GP) ablation in patients with vagally mediated bradyarrhythmia (VMB). We aimed to compare the acute procedural characteristics during FE-guided GP ablation in patients with VMB performed by first-time operators and those of a single high-volume operator. METHODS AND RESULTS: This international multicenter cohort study included data collected over 2 years from 16 cardiac hospitals. The primary operators were classified according to their prior GP ablation experience: a single high-volume operator who had performed > 50 GP ablation procedures (Group 1), and operators performing their first GP ablation cases (Group 2). Acute procedural characteristics and syncope recurrence were compared between groups. Forty-seven consecutive patients with VMB who underwent FE-guided GP ablation were enrolled, n = 31 in Group 1 and n = 16 in Group 2. The mean number of ablation points in each GP was comparable between groups. The ratio of positive vagal response during ablation on the left superior GP was higher in Group 1 (90.3% vs. 62.5%, p = .022). Ablation of the right superior GP increased heart rate acutely without any vagal response in 45 (95.7%) cases. The procedure time was longer in group 2 (83.4 ± 21 vs. 118.0 ± 21 min, respectively, p < .001). Over a mean follow-up duration of 8.0 ± 3 months (range 2-24 months), none of the patients suffered from syncope. CONCLUSION: This multi-center pilot study shows for the first time the feasibility of FE-guided GP ablation across a large group of procedure-naïve operators.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Bradicardia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos de Coortes , Humanos , Projetos Piloto , Resultado do Tratamento , Nervo Vago/cirurgia
4.
J Asthma ; 56(8): 872-881, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30003833

RESUMO

Introduction: Poorly controlled severe eosinophilic asthma is difficult and costly to manage. Reslizumab, an add-on treatment for adults with severe eosinophilic asthma, reduces the number of exacerbations and improves the quality of life (QoL). The objective of this study was to evaluate the cost-effectiveness of reslizumab. Methods: A Markov model was used to compare the cost-effectiveness of add-on reslizumab with the standard-of-care (SOC) from the US societal perspective over a five-year time horizon. Efficacy and safety inputs for the model were based on data from two clinical trials (NCT01287039 and NCT01285323). Other model inputs, including mortality rates, costs, and utility, were estimated from literature, the Centers for Disease Control and Prevention (CDC), the US Department of Veterans Affairs (VA) and the Centers for Medicare and Medicaid Services (CMS). One-way, threshold, and probabilistic sensitivity analyses (PSA) were performed. Adherence, treatment response, and the placebo effect were evaluated in separate scenario analyses. Results: The base case incremental cost-effectiveness ratio (ICER) was $697 403 (2017 USD) per quality-adjusted life-years (QALYs). In the PSA, reslizumab becomes cost-effective in 50% of the iterations at a willingness-to-pay (WTP) threshold of $689 000. The model is most sensitive to the QoL improvement with reslizumab treatment in the one-way and threshold analyses. The response and adherence models had lower ICERs than the base model but still above $500 000. The ICER of the placebo effect model was $29 820. Conclusions: The improvement in QoL and exacerbation rates with reslizumab are associated with high costs, making reslizumab unlikely to be cost-effective at the $200 000 WTP threshold.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/economia , Anticorpos Monoclonais/administração & dosagem , Asma/tratamento farmacológico , Asma/economia , Análise Custo-Benefício , Adolescente , Adulto , Antiasmáticos/administração & dosagem , Antiasmáticos/economia , Anticorpos Monoclonais/economia , Asma/diagnóstico , Criança , Bases de Dados Factuais , Feminino , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Eosinofilia Pulmonar/diagnóstico , Eosinofilia Pulmonar/tratamento farmacológico , Eosinofilia Pulmonar/economia , Anos de Vida Ajustados por Qualidade de Vida , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos
5.
Pacing Clin Electrophysiol ; 39(10): 1077-1082, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27470060

RESUMO

BACKGROUND: The purpose of this study was to compare a unique zip-type adjustable coaptive tape-based skin closure device to traditional subcuticular sutures in three domains: time, cosmesis, and wound closure-related outcomes in cardiac implantable electronic device (CIED) procedures. METHODS: A total of 40 patients were enrolled in a prospective randomized controlled trial to assess time to wound closure, as well as cosmesis and wound closure-related outcomes. RESULTS: The adjustable coaptive tape-based skin closure device had shorter overall closure time (78 ± 6.6 seconds vs 216 ± 21.5 seconds; P < 0.001) and mean closure time per centimeter (18.0 ± 2.0 s/cm vs 50.1 ± 6.7 s/cm; P < 0.001) versus sutures, with less intersurgeon and interpatient variability with the use of adjustable coaptive device versus sutures (P < 0.001). There was no difference between groups in postoperative pain or scar cosmesis during the follow-up period. Neither group had any closure-related adverse events. CONCLUSIONS: The adjustable coaptive tape-based skin closure device demonstrated shorter closure times with less variability when compared to sutures. It is a safe and acceptable alternative to sutures for skin closure following CIED implantation.


Assuntos
Pele , Técnicas de Fechamento de Ferimentos/instrumentação , Idoso , Técnicas Cosméticas , Feminino , Humanos , Masculino , Estudos Prospectivos , Fita Cirúrgica , Técnicas de Sutura , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 39(11): 1254-1260, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27550834

RESUMO

BACKGROUND: Radiofrequency (RF) technology has improved detection of retained surgical sponges with a reported 100% sensitivity and specificity. However, the potential for interactions of the RF signals emitted by the detection system with cardiac implantable electronic devices (CIEDs) or temporary pacemakers may limit its use in those patients with these devices. This study investigated whether RF detection technology causes interference or clinically significant changes in the programmed settings of implanted pacemakers and defibrillators or temporary epicardial pacemakers. METHODS: Fifty patients who were scheduled either for CIED removal or placement of a temporary epicardial pacemaker (at the time of open heart surgery) were recruited for this study. Device settings and measurements from separate interrogations before and after scanning with the RF detection system were compared. For the temporary pacemakers, we observed for any changes in hemodynamics or signs of pacing interference. RESULTS: Twenty (40%) pacemakers, 20 (40%) implantable cardioverter defibrillators, and 10 (20%) temporary pacemakers were analyzed in this study. During scanning, no signal interference was detected in any permanent device, and there were no significant changes in programmed settings after scanning with the RF detection system. However, pacing inhibition was detected with temporary pacing systems when programmed to a synchronous mode (DDD). CONCLUSIONS: RF detection technology can be safely used to scan for retained surgical sponges in patients with permanent CIEDs and temporary pacemakers set to asynchronous mode.


Assuntos
Desfibriladores Implantáveis , Corpos Estranhos/diagnóstico , Marca-Passo Artificial , Ondas de Rádio , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Pharmacoecon Open ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38858333

RESUMO

BACKGROUND: Today, there are many treatment options available for the management of ulcerative colitis, creating challenges in selecting the most efficacious and cost-effective treatment sequences. Treatments in the anti-tumor necrosis factor alpha (TNFα) therapeutic class, as well as vedolizumab, are widely used and endorsed as first-line options according to treatment guidelines. The aim of this study was to compare treatment sequences involving vedolizumab and the anti-TNFα treatment adalimumab in terms of cost-effectiveness in the treatment of moderately to severely active ulcerative colitis in Italy. METHODS: A cost-effectiveness model comparing treatment sequences within the Italian National Health Service in terms of costs and quality-adjusted life years (QALYs) with a lifetime horizon was developed. The analysis focused on the relative positioning of vedolizumab and adalimumab, leveraging the results of the landmark head-to-head VARSITY clinical trial as key inputs. The robustness of the results was investigated through a range of sensitivity and scenario analyses. RESULTS: The strategy of vedolizumab as a first-line advanced therapy followed by adalimumab was associated with higher costs and health benefits compared with first-line adalimumab followed by vedolizumab. The incremental cost-effectiveness ratio was €16,146/QALY, which was found to be robust to changes to inputs associated with areas of high uncertainty. CONCLUSION: This economic evaluation estimated a 94% probability that vedolizumab as a first-line advanced therapy is cost-effective at a threshold of €33,004/QALY when compared with first-line adalimumab sequences. Using clinical trial evidence to inform the efficacy of second-line treatments estimated that the effectiveness of anti-TNFα treatments is not substantially reduced by vedolizumab exposure.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

9.
J Cardiovasc Electrophysiol ; 24(3): 370-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23131025

RESUMO

INTRODUCTION: Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. METHODS AND RESULTS: We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. CONCLUSIONS: Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement.


Assuntos
Veia Axilar/diagnóstico por imagem , Estimulação Cardíaca Artificial , Cateterismo Venoso Central/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Implantação de Prótese/métodos , Veia Subclávia/diagnóstico por imagem , Ultrassonografia de Intervenção , Humanos , Punções
11.
Heart Rhythm ; 20(5): 680-688, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36764350

RESUMO

BACKGROUND: Little is known about the very long term durability of atrial fibrillation (AF) ablation. OBJECTIVE: The purpose of this study was to evaluate very long term AF ablation outcomes. METHODS: We followed 5200 patients undergoing 7145 ablation procedures. We evaluated outcomes after single and multiple ablation procedures for paroxysmal (PAF; 33.6%), persistent (PeAF; 56.4%), and long-standing (LsAF; 9.9%) AF. We compared 3 ablation eras by initial ablation catheter: early (101 patients) using solid big tip (SBT) catheters (October 2003 to December 2005), intermediate (2143 patients) using open irrigated tip (OIT) catheters (December 2005 to August 2016), and contemporary (2956 patients) using contact force (CF) catheters (March 2014 to December 2021). RESULTS: AF freedom at 5, 10, and 15 years was as follows: initial ablation: PAF 67.8%, 56.3%, 47.6%; PeAF 46.6%, 35.6%, 26.5%; and LsAF 30.4%, 18.0%, 3.4%; final ablation: PAF 80.3%, 72.6%, 62.5%; PeAF 60.1%, 50.2%, 42.5%; and LsAF 43.4%, 32.0%, 20.6%. For PAF and PeAF, CF ablation procedures were better than OIT ablation procedures (P < .0001) and both were better than SBT ablation procedures (P < .001). LsAF had no outcome improvement over the eras. The 8-year success rate after final ablation for CF, OIT, and SBT catheter eras was as follows: PAF 79.1%, 71.8%, 60.0%; PeAF 55.9%, 50.7%, 38.0%; and LsAF 42.7%, 36.2%, 31.8%. Highest AF recurrence was in the first 2 years, with a 2- to 15-year recurrence of 2%/yr. Success predictors after initial and final ablation procedures were younger age, smaller left atrium, shorter AF duration, male sex, less persistent AF, lower CHA2DS2-VASc score, fewer drugs failed, and more recent catheter era. CONCLUSION: After year 2, there is 2%/yr recurrence rate for all AF types. Ablation success is best in the CF catheter era, intermediate in the OIT era, and worst in the SBT era. Over the ablation eras, outcomes improved for PAF and PeAF but not for LsAF. We should follow patients indefinitely after ablation. We need an understanding of how to better ablate more persistent AF.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Recidiva , Ablação por Cateter/métodos , Fatores de Tempo , Resultado do Tratamento
12.
PLoS One ; 17(11): e0277980, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36441807

RESUMO

PURPOSE: Total knee arthroplasty (TKA) is widely recognized as an effective treatment for end-stage knee osteoarthritis (OA). Compared with conventional TKA, robotic-arm assisted TKA may improve patients' functionality and resulting quality of life by more accurate and precise component placement. Currently, the literature on cost-effectiveness of robotic-arm assisted TKA in the US is limited. The objective of this study was to assess the cost-effectiveness of robotic-arm assisted TKA relative to TKA in the Medicare-aged population including exploring the impact of hospital volume on cost-effectiveness outcomes. METHODS: We developed a decision-analytic model to evaluate the costs, health outcomes, and incremental cost-effectiveness ratio (ICER) of robotic-arm assisted TKA vs TKA in Medicare population with OA. We evaluated cost-effectiveness at a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life-year (QALY). We sourced costs from the literature including episode-of-care (EOC) costs from a Medicare study. We assessed cost-effectiveness of robotic-arm assisted TKA by hospital procedure volume and conducted deterministic (DSA) and probabilistic sensitivity analysis (PSA). RESULTS: For the average patient treated in a hospital with an annual volume of 50 procedures, robotic-arm assisted TKA resulted in a total QALY of 6.18 relative to 6.17 under conventional TKA. Total discounted costs per patient were $32,535 and $31,917 for robotic-arm assisted TKA and conventional TKA, respectively. Robotic-arm assisted TKA was cost-effective in the base case with an ICER of $41,331/QALY. In univariate DSA, cost-effectiveness outcomes were most sensitive to the annual hospital procedure volume. Robotic-arm assisted TKA was cost-effective at a WTP of $50,000/QALY only when hospital volume exceeded 49 procedures per year. In PSA, robotic-arm assisted TKA was cost-effective at a $50,000/QALY WTP threshold in 50.4% of 10,000 simulations. CONCLUSIONS: Despite high robotic purchase costs, robotic-arm assisted TKA is likely to be cost-effective relative to TKA in the Medicare population with knee OA in high-volume hospitals through lowering revision rates and decreasing post-acute care costs. Higher-volume hospitals may deliver higher value in performing in robotic-arm assisted TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Estados Unidos , Humanos , Idoso , Análise Custo-Benefício , Qualidade de Vida , Medicare , Osteoartrite do Joelho/cirurgia , Hospitais com Alto Volume de Atendimentos
13.
Heart Rhythm O2 ; 3(3): 279-287, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734295

RESUMO

Background: Atypical left atrial flutter (AFL) may be macroreentrant or spatially localized. The relationship between the critical isthmus (CI) for localized reentry with sinus rhythm (SR) conduction slowing has not been systematically examined. Objective: To examine the correlation between CI sites for localized AFL (L-AFL) and deceleration zones (DZ) identified by isochronal late activation mapping (ILAM) during baseline rhythm. Methods: Patients with localized AFL who underwent high-density activation mapping of both SR and AFL were retrospectively analyzed. L-AFL was defined as reentry restricted to 2 wall segments of the left atrium. CI was defined by activation mapping and sites of successful termination during ablation. DZ, defined as >3 isochrones within 1 cm radius during baseline rhythm, were correlated to the locations of the CI. Results: Thirty-one consecutive patients that underwent detailed sinus rhythm and AFL high-density activation maps were analyzed at 3 centers. A mean 4060 ± 3275 and 6209 ± 8656 points were collected in ILAM and AFL activation maps, respectively. At least 1 DZ (1.7 ± 0.77) was identified in all patients. ILAM showed 3.27 ± 0.52 isochrones per DZ (168 ± 32 ms), and co-localized to CI sites at a distance of 6.7 ± 3 mm. A total of 34% ± 14% of the AFL cycle length was contained within 0.5 cm of the DZ. Conclusions: In patients with L-AFL, CI co-localized with DZ during baseline rhythm, suggesting that DZ mapping during SR may yield candidate targets for ablation as an adjunct to pulmonary vein isolation to prevent a subtype of AFL.

14.
Sci Rep ; 11(1): 10838, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34035408

RESUMO

Sickle cell disease (SCD) is a group of inherited genetic conditions associated with lifelong complications and increased healthcare resource utilization. Standard treatment for SCD in the US varies based on stage of the disease and observed clinical severity. In this study, we aim to evaluate the potential cost-effectiveness of a durable cell or gene therapy cure for sickle cell disease from the US healthcare sector perspective. We developed a lifetime Markov model to evaluate the cost-effectiveness of a hypothetical single-administration durable treatment (DT) for SCD provided at birth, relative to standard of care (SOC). We informed model inputs including direct healthcare costs, health state utility weights, transition probabilities, and mortality rates using a retrospective database analysis of commercially insured individuals and the medical literature. Our primary outcome of interest was the incremental cost-effectiveness ratio (ICER) of DT versus SOC evaluated at a base case willingness-to-pay (WTP) threshold of $150,000 per quality-adjusted life year (QALY). We tested the robustness of our base case findings through scenario, deterministic sensitivity (DSA), and probabilistic sensitivity analyses (PSA). In the base case analysis, treatment with DT was cost-effective with an ICER of $140,877/QALY relative to SOC for a hypothetical cohort involving 47% females. Both males (ICER of $135,574/QALY) and females (ICER of $146,511/QALY) were similarly cost-effective to treat. In univariate DSA the base case ICER was most sensitive to the costs of treating males, DT treatment cost, and the discount rate. In PSA, DT was cost-effective in 32.7%, 66.0%, and 92.6% of 10,000 simulations at WTP values of $100,000, $150,000, and $200,000 per QALY, respectively. A scenario analysis showed cost-effectiveness of DT is highly contingent on assumed lifetime durability of the cure. A hypothetical cell or gene therapy cure for SCD is likely to be cost-effective from the US healthcare sector perspective. Large upfront costs of a single administration cure are offset by significant downstream gains in health for patients treated early in life. We find cost-effectiveness outcomes do not vary substantially by gender; however, several model parameters including assumed durability and upfront cost of DT are likely to influence cost-effectiveness findings.


Assuntos
Anemia Falciforme/terapia , Terapia Genética/economia , Simulação por Computador , Análise Custo-Benefício , Tomada de Decisões Assistida por Computador , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Cadeias de Markov , Anos de Vida Ajustados por Qualidade de Vida , Estudos Retrospectivos
15.
PLoS One ; 16(7): e0254950, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34288951

RESUMO

BACKGROUND: Tuberculosis (TB) incidence in Los Angeles County, California, USA (5.7 per 100,000) is significantly higher than the U.S. national average (2.9 per 100,000). Directly observed therapy (DOT) is the preferred strategy for active TB treatment but requires substantial resources. We partnered with the Los Angeles County Department of Public Health (LACDPH) to evaluate the cost-effectiveness of AiCure, an artificial intelligence (AI) platform that allows for automated treatment monitoring. METHODS: We used a Markov model to compare DOT versus AiCure for active TB treatment in LA County. Each cohort transitioned between health states at rates estimated using data from a pilot study for AiCure (N = 43) and comparable historical controls for DOT (N = 71). We estimated total costs (2017, USD) and quality-adjusted life years (QALYs) over a 16-month horizon to calculate the incremental cost-effectiveness ratio (ICER) and net monetary benefits (NMB) of AiCure. To assess robustness, we conducted deterministic (DSA) and probabilistic sensitivity analyses (PSA). RESULTS: For the average patient, AiCure was dominant over DOT. DOT treatment cost $4,894 and generated 1.03 QALYs over 16-months. AiCure treatment cost $2,668 for 1.05 QALYs. At willingness-to-pay threshold of $150K/QALY, incremental NMB per-patient under AiCure was $4,973. In univariate DSA, NMB were most sensitive to monthly doses and vocational nurse wage; however, AiCure remained dominant. In PSA, AiCure was dominant in 93.5% of 10,000 simulations (cost-effective in 96.4%). CONCLUSIONS: AiCure for treatment of active TB is cost-effective for patients in LA County, California. Increased use of AI platforms in other jurisdictions could facilitate the CDC's vision of TB elimination.


Assuntos
Inteligência Artificial/economia , Tuberculose/economia , Tuberculose/terapia , Adulto , Idoso , California , Análise Custo-Benefício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/economia , Projetos Piloto
16.
J Interv Card Electrophysiol ; 61(3): 525-533, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32789708

RESUMO

PURPOSE: Accessory pathway (AP) mapping is currently based on point-by-point mapping and identifying if a local electrogram's origin is atrial, pathway, or ventricular, which is time-consuming and prone to insufficient mapping. We sought to determine the feasibility of automated and high-density mapping to define AP location using open-window mapping (OWM), which does not rely on defining the electrogram's origin but simply detects the sharpest local signal at each point. METHODS: We enrolled 23 consecutive patients undergoing catheter ablation for atrioventricular reentrant tachycardia. High-density mapping was performed using OWM and ablation was performed. The successful site of ablation was determined by the loss of pathway function. RESULTS: OWM was 100% effective at identifying the successful site of ablation (average mapping time 7.3 ± 4.3 min.) Permanent AP elimination was achieved using a mean radiofrequency energy time of 18.5 ± 24.5 s/patient. Transiently successful ablations were 4.0 ± 1.8 mm from permanently successful sites and had lower contact force (5.1 ± 2.5 g vs. 11.7 ± 9.0 g; P = 0.041). Unsuccessful sites had similar contact force to permanently successful sites (12.2 ± 9.2 g vs. 11.7 ± 9.0 g; P = 0.856) but were 6.4 ± 2.0 mm away from successful sites. CONCLUSION: A novel technique of high-density, automated, and open-window mapping (OWM) effectively localizes APs without the need to differentiate the signal's site of origin. These findings suggest that OWM can be used to rapidly and successfully map and ablate APs. Both distances from the pathway and contact force were shown to be important for pathway ablation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia , Átrios do Coração , Humanos , Ondas de Rádio , Síndrome de Wolff-Parkinson-White/cirurgia
17.
Cancer Med ; 9(2): 440-446, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31749330

RESUMO

BACKGROUND: Standard treatment for locally advanced esophageal cancer usually includes a combination of chemotherapy, radiation, and surgery. In squamous cell carcinoma (SCC), recent studies have indicated that esophagectomy after chemoradiation does not significantly improve survival but may reduce recurrence at the cost of treatment-related mortality. This study aims to evaluate the cost-effectiveness of chemoradiation with and without esophagectomy. METHODS: We developed a decision tree and Markov model to compare chemoradiation therapy alone (CRT) versus chemoradiation plus surgery (CRT+S) in a cohort of 57-year-old male patients with esophageal SCC, over 25 years. We used information on survival, cancer recurrence, and side effects from a Cochrane meta-analysis of two randomized trials. Societal utility values and costs of cancer care (2017, USD) were from medical literature. To test robustness, we conducted deterministic (DSA) and probabilistic sensitivity analyses (PSA). RESULTS: In our base scenario, CRT resulted in less cost for more quality-adjusted life years (QALYs) compared to CRT+S ($154 082 for 1.32 QALYs/patient versus $165 035 for 1.30 QALYs/patient, respectively). In DSA, changes resulted in scenarios where CRT+S is cost-effective at thresholds between $100 000-$150 000/QALY. In PSA, CRT+S was dominant 17.9% and cost-effective at willingness-to-pay of $150 000/QALY 38.9% of the time, and CRT was dominant 30.6% and cost-effective 61.1% of the time. This indicates that while CRT would be preferred most of the time, variation in parameters may change cost-effectiveness outcomes. CONCLUSIONS: Our results suggest that more data is needed regarding the clinical benefits of CRT+S for treatment of localized esophageal SCC, although CRT should be cautiously preferred.


Assuntos
Quimiorradioterapia/economia , Análise Custo-Benefício , Neoplasias Esofágicas/economia , Carcinoma de Células Escamosas do Esôfago/economia , Esofagectomia/economia , Quimiorradioterapia/mortalidade , Terapia Combinada , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/terapia , Carcinoma de Células Escamosas do Esôfago/patologia , Carcinoma de Células Escamosas do Esôfago/terapia , Esofagectomia/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Taxa de Sobrevida
18.
Heart Rhythm ; 17(8): 1223-1231, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32272229

RESUMO

BACKGROUND: Little is known about the long-term outcomes and predictors of success of high-power, short-duration (HPSD) contact force (CF) atrial fibrillation (AF) ablations. OBJECTIVE: The purpose of this study was to determine long-term freedom from AF and predictors of freedom from AF for 50-W, 5- to 15-second CF ablation. METHODS: We examined 4-year outcomes and predictors of freedom from AF after AF ablation for 1250 consecutive patients undergoing HPSD CF ablations. RESULTS: Patient demographics were age 66.6 ± 10.5 years, female 30.9%, left atrial (LA) size 4.26 ± 0.66 cm, paroxysmal AF 35.7%, persistent AF 56.6%, and longstanding AF 7.7%. Initial ablation times were procedure 114.2 ± 45.9 minutes, fluoroscopy 15.5 ± 11.5 minutes, and total radiofrequency 20.6 ± 7.7 minutes. TactiCath was used in 47.7%, SmartTouch in 52.3%, and posterior wall isolation (PWI) was performed in 34%. Four-year freedom from AF after multiple ablations were paroxysmal AF 87.0%, persistent AF 71.9%, and longstanding AF 64.9%. Single procedure success was 74.9% for TactiCath, 64.7% for SmartTouch (P <.001), and 73.0% for no PWI vs 58.9% for PWI (P <.0001). PWI did not change outcomes for paroxysmal AF but had worse outcomes for nonparoxysmal AF. Multivariate analysis showed 6 independent predictors of worse outcome after initial ablation: older age (P = .014), female gender (P <.0001), persistent AF (P = .0001), larger LA size (P <.001), PWI (P = .049), and use of SmartTouch vs TactiCath catheter (P = .007). Redo ablations were performed in 13.8%, and the outcome was better when more veins had reconnected after the initial ablation and when AF was paroxysmal. CONCLUSION: Analysis revealed 6 independent predictors of outcome for HPSD CF. At redo ablations, the outcome was better if more veins had reconnected and could be re-isolated.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Catéteres , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 74(4): 598-605, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19496111

RESUMO

OBJECTIVES: The aims of this review are to examine the biochemical features of theophylline, caffeine, adenosine, and dipyridamole, their effects on coronary hyperemia, and to make recommendations on performing hyperemic lesion assessment after taking caffeine or theophylline. BACKGROUND: It is commonly thought that caffeine and theophylline interfere with adenosine and dipyridamole induced coronary hyperemia, thus frequently delaying scheduled assessments after inadvertent consumption. However, a limited amount of studies address the interactions of these substances thus leaving no clear consensus on when to delay coronary assessment after their intake. METHODS: For biochemical information on each substance, online and textbook references were utilized. For studies on the interactions of the substances with coronary hyperemia, broad search terms such as "caffeine AND adenosine" were applied in the major research data bases. RESULTS: A serum caffeine level of 3 to 4 mg/L at the time of an adenosine-hyperemia study does not affect the ability of perfusion stress imaging to detect coronary artery disease. The interactions of theophylline with adenosine-hyperemia are less clear while both caffeine and theophylline show significant interaction with dipyridamole-hyperemia. CONCLUSIONS: For dipyridamole-stress myocardial perfusion studies, caffeine products and theophylline medications should be discontinued for 24 hr. For adenosine-stress myocardial perfusion studies, theophylline medications should be discontinued for 12 hr; however, one cup of coffee may be taken up to 1 hr before the test without necessitating a delay or cancellation of the study. These same considerations hold true for patients undergoing cardiac catheterization and intravenous adenosine-induced hyperemia.


Assuntos
Adenosina , Cafeína/administração & dosagem , Circulação Coronária/efeitos dos fármacos , Doença das Coronárias/diagnóstico , Dipiridamol , Hiperemia/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Teofilina/administração & dosagem , Vasodilatadores , Animais , Cafeína/sangue , Doença das Coronárias/fisiopatologia , Esquema de Medicação , Interações Medicamentosas , Ecocardiografia Doppler , Humanos , Tomografia por Emissão de Pósitrons , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Teofilina/sangue , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA