Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 355
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 309(1): e222432, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37787672

RESUMO

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.


Assuntos
Artérias , Tomografia Computadorizada por Raios X , Humanos , Artefatos , Brônquios , Meios de Contraste
2.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36920517

RESUMO

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , Fótons
3.
Radiology ; 303(2): 303-313, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166583

RESUMO

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Assuntos
Angiografia por Tomografia Computadorizada , Fótons , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 32(6): 4292-4303, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35029730

RESUMO

OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: • There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). • Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). • In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Capacidade Vital
5.
Eur Radiol ; 32(1): 524-532, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34185147

RESUMO

OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação
6.
Emerg Infect Dis ; 27(5)2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33900908

RESUMO

Understanding the immune response to Middle East respiratory syndrome coronavirus (MERS-CoV) is crucial for disease prevention and vaccine development. We studied the antibody responses in 48 human MERS-CoV infection survivors who had variable disease severity in Saudi Arabia. MERS-CoV-specific neutralizing antibodies were detected for 6 years postinfection.


Assuntos
Infecções por Coronavirus , Coronavírus da Síndrome Respiratória do Oriente Médio , Animais , Formação de Anticorpos , Camelus , Infecções por Coronavirus/epidemiologia , Humanos , Arábia Saudita/epidemiologia
7.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
8.
Eur Radiol ; 31(9): 7132-7142, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740093

RESUMO

OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Meios de Contraste , Relação Dose-Resposta a Droga , Humanos , Iodo/administração & dosagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
9.
Inorg Chem ; 60(20): 15278-15290, 2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34581183

RESUMO

The synthesis and photophysics (UV-vis absorption, emission, and transient absorption) of four neutral heteroleptic cyclometalated iridium(III) complexes (Ir-1-Ir-4) incorporating thiophene/selenophene-diketopyrrolopyrrole (DPP)-substituted N-heterocyclic carbene (NHC) ancillary ligands are reported. The effects of thiophene versus selenophene substitution on DPP and bis- versus monoiridium(III) complexation on the photophysics of these complexes were systematically investigated via spectroscopic techniques and density functional theory calculations. All complexes exhibited strong vibronically resolved absorption in the regions of 500-700 nm and fluorescence at 600-770 nm, and both are predominantly originated from the DPP-NHC ligand. Complexation induced a pronounced red shift of this low-energy absorption band and the fluorescence band with respect to their corresponding ligands due to the improved planarity and extended π-conjugation in the DPP-NHC ligand. Replacing the thiophene units by selenophenes and/or biscomplexation led to the red-shifted absorption and fluorescence spectra, accompanied by the reduced fluorescence lifetime and quantum yield and enhanced population of the triplet excited states, as reflected by the stronger triplet excited-state absorption and singlet oxygen generation.

10.
BMC Cardiovasc Disord ; 21(1): 168, 2021 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-33838664

RESUMO

BACKGROUND: Hypertension and diabetes mellitus (DM), are highly prevalent worldwide health non-communicable diseases, and are associated with chronic complications. The co-existence of both conditions accelerates the related complications and increases morbidities and mortalities. A cross-sectional study was conducted in Nahr an Nil State (River Nile State) in Sudan between May and August 2018 to identify the prevalence of hypertension and risk factors among patients with DM in that region. RESULTS: The median (interquartile) age of the 1,973 enrolled patients was 58.0 (50.0‒65.0) years, and 818 (45.6%) were males. The median (interquartile) duration of diabetes was 5.0 (3.0‒9.0) years. Of the 1,973 enrolled participants, 21.7%, 1.3%, 37.1%, and 39.9% were normal weight, underweight, overweight, and obese, respectively. Of 1,973 854 (47.6%) patients also had hypertension. Logistic regression analyses showed that elderly patients (adjusted odds ratio [AOR] = 1.03, 95%; confidence interval [CI] = 1.02‒1.04), males (AOR = 2.96, 95%; CI = 2.15‒4.07), employed patients (AOR = 1.92, 95%; CI = 1.38‒2.70), obese patients (AOR = 1.59, 95%; CI = 1.21‒2.08), and patients with diabetic foot (DF) (AOR = 2.45, 95%; CI = 1.72‒3.47) were at higher risk for hypertension. Conversely, patients with Type 2 DM (T2DM) (AOR = 0.63, 95%; CI = 0.50‒0.80) were at lower risk for hypertension. There was no significant association between overweight, uncontrolled DM, and hypertension. CONCLUSION: This study showed a high prevalence of hypertension among patients with DM. Notably, older age, male gender, employment, duration of DM, DF, underweight, and obesity were significant predictors of hypertension among patients with DM.


Assuntos
Diabetes Mellitus/epidemiologia , Hipertensão/epidemiologia , Adulto , Fatores Etários , Idoso , Estudos Transversais , Diabetes Mellitus/diagnóstico , Emprego , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Prevalência , Medição de Risco , Fatores de Risco , Fatores Sexuais , Sudão/epidemiologia , Magreza/epidemiologia , Fatores de Tempo
11.
Int J Clin Pract ; 75(12): e14892, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34541736

RESUMO

OBJECTIVE: The aim of this study was to determine the prevalence and associated factors for diabetic foot (DF) amongst patients with diabetes Mellites (DM) in Nahr an Nil State (River Nile State), Sudan. METHODS: We conducted a cross-sectional study between May and August 2018. DM patients were examined for DF, and clinical data were collected through a questionnaire. RESULTS: A total of 2048 DM patients were enrolled in the study. Their median (interquartile range) age was 58 (15) years. Over half (54.2%) of the patients were female. The median (interquartile range) of the duration of diabetes was 5 (6) years. In this sample, 70.1% of the patients had type 2 DM and 47.6% had hypertension as well. Of all enrolled patients, 21.2% had normal weight, 1.2% were underweight, 37.2% were overweight and 40.4% were obese. Two hundred and sixty (12.7%) patients had DF. Multivariate regression analyses showed that age [adjusted odds ratio (AOR) = 1.21; 95% confidence interval (CI): 1.18-1.24] and duration of DM (AOR = 1.09; 95% CI: 1.05-1.14) were positively associated with DF. Moreover, type 2 DM (AOR = 1.77; 95% CI: 1.17-2.68), family history of DM (AOR = 1.5; 95% CI: 1.07-2.09), hypertension (AOR = 2.93; 95% CI: 2.07-4.16) and obesity (AOR = 2.86; 95% CI: 1.70-4.81) were associated with DF. There was no significant association between DF and gender or overweight status. CONCLUSION: This study found a high prevalence of DF. Older age, type 2 DM, duration of DM, family history of DM and hypertension are associated with DF.


Assuntos
Diabetes Mellitus , Pé Diabético , Idoso , Estudos Transversais , Pé Diabético/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Sudão/epidemiologia
12.
Med J Malaysia ; 76(4): 603-605, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34305131

RESUMO

Acute compartment syndrome (ACS) is a surgical emergency that requires timely recognition and early management for a good outcome. We report a case of a 71- year-old male seen at the Emergency Department of Universiti Sains Malaysia (USM), Malaysia, on anticoagulant therapy for valvular atrial fibrillation, who had sustained a closed fracture of the left distal end radius following a fall. Examination of the left upper limb showed deformity and tenderness over the left wrist, associated with swelling and a tense anterior compartment with blisters formation and rapid expansion of hematoma at the cubital fossa away from the fracture site. Both radial and brachial pulses were absent and confirmed with the absence of a doppler signal over the brachial and radial artery and CT angiography of the left upper limb showed there was a vascular injury of the brachial artery. Fasciotomy of the left upper limb and revascularization of the left brachial artery was done. Intraoperative findings showed a tight anterior compartment with muscle bulging upon compartment release with a complete cut of the left distal brachial artery. The primary end-to-end vascular anastomosis was done and distal circulation was restored. The distal end radius fracture was treated conservatively. The patient underwent split skin grafting of the left forearm after 6 weeks post-injury and went home well. It is critical to recognize a concomitant vascular injury in fracture-related ACS as the clinical feature may overlap. Failure in detection of concomitant vascular injury may lead to emergency fasciotomy without vascular exploration and repair.


Assuntos
Síndromes Compartimentais , Fraturas do Rádio , Idoso , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/cirurgia , Síndromes Compartimentais/diagnóstico , Síndromes Compartimentais/etiologia , Síndromes Compartimentais/cirurgia , Fasciotomia , Antebraço , Humanos , Masculino , Fraturas do Rádio/complicações , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia
13.
Eur Radiol ; 30(1): 425-431, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332557

RESUMO

OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT. MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity. RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001). CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH. KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
14.
J Biomech Eng ; 142(5)2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31701130

RESUMO

The menisci are fibrocartilaginous tissues that are crucial to the load-sharing and stability of the knee, and when injured, these properties are compromised. Meniscus replacement scaffolds have utilized the circumferential alignment of fibers to recapitulate the microstructure of the native meniscus; however, specific consideration of size, shape, and morphology has been largely overlooked. The purpose of this study was to personalize the fiber-reinforcement network of a meniscus reconstruction scaffold. Human cadaveric menisci were measured for a host of tissue (length, width) and subtissue (regional widths, root locations) properties, which all showed considerable variability between donors. Next, the asymmetrical fiber network was optimized to minimize the error between the dimensions of measured menisci and predicted fiber networks, providing a 51.0% decrease (p = 0.0091) in root-mean-square (RMS) error. Finally, a separate set of human cadaveric knees was obtained, and donor-specific fiber-reinforced scaffolds were fabricated. Under cyclic loading for load-distribution analysis, in situ implantation of personalized scaffolds following total meniscectomy restored contact area (253.0 mm2 to 488.9 mm2, p = 0.0060) and decreased contact stress (1.96 MPa to 1.03 MPa, p = 0.0025) to near-native values (597.4 mm2 and 0.83 MPa). Clinical use of personalized meniscus devices that restore physiologic contact stress distributions may prevent the development of post-traumatic osteoarthritis following meniscal injury.


Assuntos
Articulação do Joelho , Menisco , Adulto , Humanos , Traumatismos do Joelho , Alicerces Teciduais
15.
Rev Invest Clin ; 72(4): 239-249, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33064708

RESUMO

Human papillomavirus (HPV) has been associated with the development of precancerous lesions of the cervix and cervical cancer (CC). Prophylactic HPV vaccination induces the development of a specific memory immune response that facilitates HPV elimination once the natural infection occurs. At present, in addition to the prophylactic vaccine, therapeutic vaccines are being developed and researched with the aim of inducing an immune response that allows the elimination of HPV-infected cells. The purpose of this study is to describe the current evidence on the use of therapeutic vaccines and their effect on cervical precancerous lesions, to establish recommendations on their clinical use. So far, the studies that have generated results have described a marginal beneficial effect of the prophylactic vaccine in the management of infection and pre-invasive lesions. Based on the evidence, continuing research on the efficacy and safety of therapeutic vaccines for the treatment of cervical intraepithelial lesions is recommended. The use of the HPV prophylactic vaccine as treatment for pre-existing lesions is not advised, but it is recommended to prevent new lesions.


Assuntos
Infecções por Papillomavirus , Vacinas contra Papillomavirus , Lesões Pré-Cancerosas , Neoplasias do Colo do Útero , Feminino , Humanos , Papillomaviridae , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/prevenção & controle , Lesões Pré-Cancerosas/prevenção & controle , Neoplasias do Colo do Útero/prevenção & controle
16.
Rev Invest Clin ; 73(3)2020 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-32488223

RESUMO

BACKGROUND: Ovarian cancer is the most lethal gynecologic cancer. Although most patients respond adequately to the first-line therapy, up to 85% experience a recurrence of disease, which carries a poor prognosis. Mitotic arrest deficiency 1 is a protein that helps in the assembly of the mitotic spindle assembly checkpoint by preventing anaphase until all chromatids are properly aligned. A single-nucleotide polymorphism in the MAD1L1 gene is prevalent in patients with advanced epithelial ovarian cancer and alters the way in which it responds to chemotherapy. OBJECTIVE: The objective of the study was to study the relationship between the rs1801368 polymorphism of MAD1L1 and prognosis of ovarian adenocarcinoma. METHODS: A total of 118 patients in whom the MAD1L1 gene was sequenced were analyzed using descriptive and comparative statistics. RESULTS: Patients carrying the wild-type genotype had a higher distribution of early-stage disease. Having a MAD1L1 polymorphic allele increased the risk of being non-sensitive to chemotherapy. The median disease-free survival for patients with the wild-type MAD1L1 was 46.93 months, compared to 10.4 months for patients with at least one polymorphic allele. CONCLUSIONS: The rs1801368 polymorphism of MAD1L1 gene worsens prognosis in patients with ovarian adenocarcinoma. Traditional therapy for ovarian cancer might not be optimal in patients carrying this polymorphism.

17.
Rev Invest Clin ; 72(6): 372-379, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33052898

RESUMO

BACKGROUND: Ovarian cancer is the most lethal gynecologic cancer. Although most patients respond adequately to the first-line therapy, up to 85% experience a recurrence of disease, which carries a poor prognosis. Mitotic arrest deficiency 1 is a protein that helps in the assembly of the mitotic spindle assembly checkpoint by preventing anaphase until all chromatids are properly aligned. A single-nucleotide polymorphism in the MAD1L1 gene is prevalent in patients with advanced epithelial ovarian cancer and alters the way in which it responds to chemotherapy. OBJECTIVE: The objective of the study was to study the relationship between the rs1801368 polymorphism of MAD1L1 and prognosis of ovarian adenocarcinoma. METHODS: A total of 118 patients in whom the MAD1L1 gene was sequenced were analyzed using descriptive and comparative statistics. RESULTS: Patients carrying the wild-type genotype had a higher distribution of early-stage disease. Having a MAD1L1 polymorphic allele increased the risk of being non-sensitive to chemotherapy. The median disease-free survival for patients with the wild-type MAD1L1 was 46.93 months, compared to 10.4 months for patients with at least one polymorphic allele. CONCLUSIONS: The rs1801368 polymorphism of MAD1L1 gene worsens prognosis in patients with ovarian adenocarcinoma. Traditional therapy for ovarian cancer might not be optimal in patients carrying this polymorphism.


Assuntos
Adenocarcinoma/genética , Proteínas de Ciclo Celular/genética , Neoplasias Ovarianas/genética , Polimorfismo de Nucleotídeo Único , Adenocarcinoma/mortalidade , Adolescente , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/mortalidade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Adulto Jovem
18.
Histopathology ; 72(3): 516-524, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28858401

RESUMO

AIMS: The pathogenesis, viral localization and histopathological features of Middle East respiratory syndrome - coronavirus (MERS-CoV) in humans are not described sufficiently. The aims of this study were to explore and define the spectrum of histological and ultrastructural pathological changes affecting various organs in a patient with MERS-CoV infection and represent a base of MERS-CoV histopathology. METHODS AND RESULTS: We analysed the post-mortem histopathological findings and investigated localisation of viral particles in the pulmonary and extrapulmonary tissue by transmission electron microscopic examination in a 33-year-old male patient of T cell lymphoma, who acquired MERS-CoV infection. Tissue needle biopsies were obtained from brain, heart, lung, liver, kidney and skeletal muscle. All samples were collected within 45 min from death to reduce tissue decomposition and artefact. Histopathological examination showed necrotising pneumonia, pulmonary diffuse alveolar damage, acute kidney injury, portal and lobular hepatitis and myositis with muscle atrophic changes. The brain and heart were histologically unremarkable. Ultrastructurally, viral particles were localised in the pneumocytes, pulmonary macrophages, renal proximal tubular epithelial cells and macrophages infiltrating the skeletal muscles. CONCLUSION: The results highlight the pulmonary and extrapulmonary pathological changes of MERS-CoV infection and provide the first evidence of the viral presence in human renal tissue, which suggests tissue trophism for MERS-CoV in kidney.


Assuntos
Infecções por Coronavirus/patologia , Adulto , Humanos , Masculino , Microscopia Eletrônica de Transmissão , Coronavírus da Síndrome Respiratória do Oriente Médio
19.
Langmuir ; 34(27): 7951-7957, 2018 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-29889535

RESUMO

Macroscopic single-wall carbon nanotube (SWCNT) films of nanoscale thickness have significant potential for an array of applications that demand thin, transparent, conductive coatings. Using macroscopic micrometer thick polystyrene sheets as a reference, we characterize the elastic response of freestanding multifunctional SWCNT nanosheets possessing both exceptionally high Young's modulus and good durability. Thin SWCNT films (20-200 nm thick) asymmetrically "doped" with dilute concentrations of superparamagnetic colloids were suspended in ethanol as freestanding nanosheets. Through repeated and controlled deformation in an external magnetic field, we measure the temporal relaxation of nanosheet curvature back to equilibrium. From the relaxation time and its dependence on nanosheet thickness and length, we extract the SWCNT nanosheet modulus through a simple viscoelastic model. Our results are consistent with nearly ideal SWCNT rigidity percolation with moduli approaching 200 GPa and limited plasticity for sufficiently thick sheets, which we attribute to the screening of van der Waals interactions by the surrounding solvent and the macroscopic nature of the deformation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA