RESUMO
BACKGROUND: Instead of choosing one endoscopic ultrasound (EUS) needle over the other, some advocate the use of fine-needle aspiration (FNA) and fine-needle biopsy (FNB) consecutively. We explored the yield of combined use of 20âG FNB and 25âG FNA needles in patients with a suspicious solid gastrointestinal lesion. METHODS: Patients from the ASPRO study who were sampled with both needles during the same procedure were included. The incremental yield of dual sampling compared with the yield of single needle use on the diagnostic accuracy for malignancy was assessed for both dual sampling approaches - FNA followed by FNB, and vice versa. RESULTS: 73 patients were included. There were 39 (53â%) pancreatic lesions, 18 (25â%) submucosal masses, and 16 (22â%) lymph nodes. FNA was used first in 24 patients (33â%) and FNB was used first in 49 (67â%). Generally, FNB was performed after FNA to collect tissue for ancillary testing (75â%), whereas FNA was used after FNB to allow for on-site pathological assessment (76â%). Diagnostic accuracy for malignancy of single needle use increased from 78â% to 92â% with dual sampling (Pâ=â0.002). FNA followed by FNB improved the diagnostic accuracy for malignancy (Pâ=â0.03), whereas FNB followed by FNA did not (Pâ=â0.13). CONCLUSION: Dual sampling only improved diagnostic accuracy when 25âG FNA was followed by 20âG FNB and not vice versa. As the diagnostic benefit of the 20âG FNB over the 25âG FNA needle has recently been proven, sampling with the FNB needle seems a logical first choice.
Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Endossonografia , Humanos , Agulhas , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Manejo de EspécimesRESUMO
BACKGROUND AND AIMS: Several studies have compared EUS-guided FNA with fine-needle biopsy (FNB), but none have proven superiority. We performed a multicenter randomized controlled trial to compare the performance of a commonly used 25-gauge FNA needle with a newly designed 20-gauge FNB needle. METHODS: Consecutive patients with a solid lesion were randomized in this international multicenter study between a 25-gauge FNA (EchoTip Ultra) or a 20-gauge FNB needle (ProCore). The primary endpoint was diagnostic accuracy for malignancy and the Bethesda classification (non-diagnostic, benign, atypical, malignant). Technical success, safety, and sample quality were also assessed. Multivariable and supplementary analyses were performed to adjust for confounders. RESULTS: A total of 608 patients were allocated to FNA (n = 306) or FNB (n = 302); 312 pancreatic lesions (51%), 147 lymph nodes (24%), and 149 other lesions (25%). Technical success rate was 100% for the 25-gauge FNA and 99% for the 20-gauge FNB needle (P = .043), with no differences in adverse events. The 20-gauge FNB needle outperformed 25-gauge FNA in terms of histologic yield (77% vs 44%, P < .001), accuracy for malignancy (87% vs 78%, P = .002) and Bethesda classification (82% vs 72%, P = .002). This was robust when corrected for indication, lesion size, number of passes, and presence of an on-site pathologist (odds ratio, 3.53; 95% confidence interval, 1.55-8.56; P = .004), and did not differ among centers (P = .836). CONCLUSION: The 20-gauge FNB needle outperformed the 25-gauge FNA needle in terms of histologic yield and diagnostic accuracy. This benefit was irrespective of the indication and was consistent among participating centers, supporting the general applicability of our findings. (Clinical trial registration number: NCT02167074.).
Assuntos
Biópsia com Agulha de Grande Calibre/instrumentação , Carcinoma/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Tumores do Estroma Gastrointestinal/patologia , Neoplasias Intestinais/patologia , Linfadenopatia/patologia , Linfoma/patologia , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/patologia , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Idoso , Carcinoma/diagnóstico , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/patologia , Endossonografia , Feminino , Tumores do Estroma Gastrointestinal/diagnóstico , Humanos , Biópsia Guiada por Imagem/instrumentação , Neoplasias Intestinais/diagnóstico , Linfadenopatia/diagnóstico , Metástase Linfática , Linfoma/diagnóstico , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Agulhas , Tumores Neuroendócrinos/diagnóstico , Razão de Chances , Neoplasias Pancreáticas/diagnóstico , Pancreatite Crônica/diagnóstico , Pancreatite Crônica/patologia , Sensibilidade e EspecificidadeRESUMO
BACKGROUND AND AIM: A recently carried out randomized controlled trial showed the benefit of a novel 20-G fine-needle biopsy (FNB) over a 25-G fine-needle aspiration (FNA) needle. The current study evaluated the reproducibility of these findings among expert academic and non-academic pathologists. METHODS: This study was a side-study of the ASPRO (ASpiration versus PROcore) study. Five centers retrieved 74 (59%) consecutive FNB and 51 (41%) FNA samples from the ASPRO study according to randomization; 64 (51%) pancreatic and 61 (49%) lymph node specimens. Samples were re-reviewed by five expert academic and five non-academic pathologists and rated in terms of sample quality and diagnosis. Ratings were compared between needles, expert academic and non-academic pathologists, target lesions, and cytology versus histological specimens. RESULTS: Besides a higher diagnostic accuracy, FNB also provided for a better agreement on diagnosing malignancy (ĸ = 0.59 vs ĸ = 0.76, P < 0.001) and classification according to Bethesda (ĸ = 0.45 vs ĸ = 0.61, P < 0.001). This equally applied for expert academic and non-academic pathologists and for pancreatic and lymph node specimens. Sample quality was also rated higher for FNB, but agreement ranged from poor (ĸ = 0.04) to fair (ĸ = 0.55). Histology provided better agreement than cytology, but only when a core specimen was obtained with FNB (P = 0.004 vs P = 0.432). CONCLUSION: This study shows that the 20-G FNB outperforms the 25-G FNA needle in terms of diagnostic agreement, independent of the background and experience of the pathologist. This endorses use of the 20-G FNB needle in both expert and lower volume EUS centers.
Assuntos
Competência Clínica , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico , Patologistas/normas , Humanos , Curva ROC , Reprodutibilidade dos TestesRESUMO
BACKGROUND: Biliary strictures (BS) are a common complication of liver transplantation. The standard treatment is sequential insertion of increasing numbers of plastic stents by endoscopic retrograde cholangiopancreatography (ERCP). Despite high success rates, some strictures fail to resolve and require surgery as definitive treatment. GOALS: To identify predictors of response or failure of standard endoscopic treatment, allowing earlier referral to alternative modalities when needed and avoiding unnecessary procedures. STUDY: Database of Gastroenterology Department at Tel Aviv Medical Center was retrospectively reviewed, and data regarding patients who underwent liver transplantation and developed BS were analyzed. RESULTS: Thirty-one patients met the study criteria. Twenty-four (77.4%) resolved with plastic stenting and 7 ultimately required surgery. There were no significant differences between stent responders and nonresponders regarding demographics, transplant and postoperative hospitalization data, time from transplantation to presentation with stricture, total number of ERCP sessions, or maximal number of stents.A trend toward difference was noted in the time elapsed between the first and the second ERCP, whereby ERCP nonresponders required a second procedure sooner than responders. Patients presenting to their second procedure as scheduled ultimately had a 95% endoscopic success rate, whereas those presenting urgently with acute cholangitis had a 55% failure rate (P=0.02). CONCLUSIONS: Urgent repeat ERCP is a harbinger of ultimate failure of plastic stent treatment for BS after liver transplant. This finding may assist earlier triage of these patients toward alternative treatment such as metal stents or surgery, thus sparing needless procedures and complications.
Assuntos
Ductos Biliares/cirurgia , Colangiopancreatografia Retrógrada Endoscópica/métodos , Transplante de Fígado/efeitos adversos , Stents , Adulto , Idoso , Ductos Biliares/patologia , Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Constrição Patológica , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Israel , Transplante de Fígado/métodos , Masculino , Pessoa de Meia-Idade , Plásticos , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Up to 3.4% of Crohn's disease (CD) patients will be diagnosed with concomitant primary sclerosing cholangitis (PSC). Despite the worldwide increase incidence of CD, data on the clinical characteristics of PSC-CD patients are scarce. OBJECTIVES: To clinically characterize CD in patients who have concomitant PSC. METHODS: A retrospective case-control analysis was conducted with 18 CD patients with concomitant PSC who attended the Inflammatory Bowel Disease Center at the Tel Aviv Sourasky Medical Center between 2011-2014 (PSC-CD patients). They were matched by age, gender, and disease duration to 90 control patients (those with CD who did not have concomitant PSC). Disease phenotype (according to the Montreal classification), demographics, and clinical data were compared in the two groups. RESULTS: PSC-CD patients were characterized by a disease that was more frequently limited to the colon (L2) (50% vs. 16%, P = 0.004) and by a non-stricturing and non-penetrating inflammatory phenotype (83% vs. 33%, P = 0.0001) compared to controls who had an increased prevalence of the penetrating phenotype (B3) (6% vs. 33% P < 0.05). Use of 5-aminosalicylic acid agents as a single therapy was significantly more prevalent among PSC-CD patients than in controls (39% vs. 7%, P < 0.005). In contrast, biologic therapy was significantly less common among PSC-CD patients compared to controls (17% vs. 52%, P = 0.0086). CONCLUSIONS: Patients with PSC-CD are clinically distinct from patients with isolated CD, and are characterized by predominant colonic involvement and an inflammatory, non-stricturing and non-penetrating phenotype.
Assuntos
Colangite Esclerosante , Doença de Crohn , Trato Gastrointestinal , Mesalamina/uso terapêutico , Adulto , Anti-Inflamatórios não Esteroides/uso terapêutico , Estudos de Casos e Controles , Colangite Esclerosante/diagnóstico , Colangite Esclerosante/epidemiologia , Colangite Esclerosante/fisiopatologia , Colonoscopia/métodos , Comorbidade , Constrição Patológica , Doença de Crohn/diagnóstico , Doença de Crohn/epidemiologia , Doença de Crohn/fisiopatologia , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Trato Gastrointestinal/patologia , Humanos , Israel/epidemiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-IdadeRESUMO
Background Staple-line leak following laparoscopic sleeve gastrectomy is a dire adverse event. While the treatment of acute and early leaks is well established, there is still dispute regarding late and chronic leaks. We describe an endoscopic approach combining septotomy and sleeve stricture dilation for treating late/chronic leaks. Methods Ten consecutive patients with late/chronic proximal leaks were treated at our center. The septum separating the sleeve lumen from the perigastric cavity was progressively dissected over several sessions and the downstream stricture was pneumatically dilated. The technical and clinical success rates were evaluated. Results: All ten patients were treated successfully. Eight patients had sleeve strictures that were dilated in conjunction with septotomy. A mean of five sessions over the course of 43 days was needed to complete treatment. In two patients with a small perigastric cavity and no stricture, septotomy was achieved with through-the-scope balloon dilation of the fistula. No adverse events were encountered. Conclusions Septotomy accompanied by stricture dilation seems highly effective and safe in late and chronic leaks following sleeve gastrectomy.
Assuntos
Fístula Anastomótica/cirurgia , Endoscopia Gastrointestinal/métodos , Gastrectomia/efeitos adversos , Adulto , Fístula Anastomótica/etiologia , Doença Crônica , Constrição Patológica/etiologia , Constrição Patológica/terapia , Dilatação , Feminino , Humanos , Laparoscopia , Masculino , Estudos Retrospectivos , Grampeamento Cirúrgico/efeitos adversos , Fatores de TempoRESUMO
BACKGROUND AND AIMS: The self-propelled disposable colonoscope (SPDC) with a 360° view is designed to enhance visualization, minimize risks of perforation and infection transmission, and shorten operator training time associated with conventional colonoscopy (CC). We evaluated SPDC efficacy for cecal intubation and safety. METHODS: Prospective patients presenting for colorectal cancer screening underwent SPDC immediately followed by CC. Initial patients necessary for SPDC operators to achieve proficiency comprised the training cohort. Subsequent enrolled patients comprised the study cohort. SPDC colonoscopy was performed up to the cecum, where anatomic landmarks were photographed and mucosal suction marks were placed. During SPDC withdrawal, polyps were recorded and similarly marked. On the second pass (by using CC), any potential mucosal damage and suction marks from the SPDC as well as polyps were recorded. Main endpoints included SPDC cecal intubation rates, confirmed by anatomic landmarks and residual marks seen on subsequent CC, and frequency and severity of adverse events and mucosal damage with SPDC. The secondary endpoint was subjective procedure proficiency, evaluated by the operator based on the training cohort. The tertiary endpoint was documenting pathologies visualized with SPDC. RESULTS: Fifty-six of 58 enrolled subjects completed the study. Proficiency with SPDC was attained after 8 to 10 procedures. Cecal intubation was successful in 98.2% (55/56 subjects; 95% confidence interval [CI], 90.4%-99.9%), including 100% (95% CI, 90.7%-100%) of the study cohort and 94.4% (95% CI, 72.7%-99.9%) of the training cohort. No mucosal damage or adverse events were reported. SPDC detected 87.5% of polyps seen in tandem CC, including all polyps larger than 5 mm. CONCLUSIONS: SPDC was highly successful, simple to use, and safe in achieving complete colonoscopy (cecal intubation). ( CLINICAL TRIAL REGISTRATION NUMBER: 0692-12-TLV.).
Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscópios , Colonoscopia/instrumentação , Equipamentos Descartáveis , Adulto , Idoso , Pontos de Referência Anatômicos , Ceco , Competência Clínica , Colonoscópios/efeitos adversos , Colonoscopia/efeitos adversos , Feminino , Humanos , Mucosa Intestinal/lesões , Intubação Gastrointestinal , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Estudos ProspectivosRESUMO
OBJECTIVE: To improve the preoperative assessment of pancreatic incidentalomas (PIs) by analysis of 1 index case and characterization of the published features of intrapancreatic accessory spleen (IPAS) compared to pancreatic neuroendocrine tumor (PNET). METHODS: A search of the literature using the online database MEDLINE. RESULTS: In all, 46 cases of IPAS have been described to date: 17 were "presumed" as IPAS based on technetium-99m (Tc-99m) scanning, fine-needle aspiration (FNA) stain for CD8, or contrast-enhanced sonography; 29 were misdiagnosed as PNET and underwent surgery. The pancreatic lesions were 1) mostly solitary; 2) solid on imaging; 3) well defined; 4) located predominantly at the pancreatic tail; 5) not exceeding 3 cm in the largest diameter; 5) all detected in adults (22-81 years); 6) not related to sex. In subjects referred for surgery, standard imaging studies/imaging protocols did not differentiate between IPAS and PNET. FNA was performed in 5/46 cases, all of which were false-positive for PNET. Immunohistochemical staining for T-cells on FNA material and specific imaging features (characteristic arciform splenic enhancement pattern on dynamic computed tomography [CT]; nuclear scintigraphies with radioisotope specifically trapped by splenic tissue [Tc-99m]) or contrast-enhanced sonography offered valuable clues. Still, distal pancreatectomy and splenectomy was carried out in 72%, and the rest had distal pancreatectomies. CONCLUSION: IPAS should be considered before surgery in patients with PIs. A new practical algorithm is presented for better preoperative evaluation of such lesions; it combines the recognition of early indicators and sequential consideration of cytologic and imaging features to decrease the hazards of unnecessary major surgery. ABBREVIATIONS: CT = computed tomography EUS = endoscopic ultrasound FNA = fine-needle aspiration HDRBC = heat-damaged red blood cells IPAS = intrapancreatic accessory spleen MRI = magnetic resonance tomography NF-PNET = nonfunctioning pancreatic neuroendocrine tumor PET = positron emission tomography PNET = pancreatic neuroendocrine tumor PI = pancreatic incidentalomas SPIO = superparamagnetic iron oxide Tc-99m = technetium-99m.
Assuntos
Coristoma/diagnóstico , Diagnóstico Diferencial , Pancreatopatias/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Baço , Adulto , Idoso , Idoso de 80 Anos ou mais , Coristoma/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatopatias/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto JovemRESUMO
BACKGROUND: Patients with familial adenomatous polyposis (FAP) are prone to developing duodenal adenoma and cancer. Optimal surveillance and management of these adenomas are not well established. OBJECTIVE: We assessed the outcome of FAP patients undergoing intense multimodal surveillance and subsequent endoscopic resection of advanced lesions. PATIENTS: Eighty consecutive FAP patients enrolled during 2001 to 2011 from the Familial Cancer Clinic of a tertiary hospital as part of routine surveillance. DESIGN: Case series, prospective in years 2006 to 2011 and retrospective in years 2001 to 2006. SETTING AND INTERVENTION: Patients were followed by annual forward-view and/or side-view upper endoscopy. A biopsy sample was obtained from visible lesions and normal papillae. Ampullary adenomas were further assessed by EUS to determine dimensions and resectability. Advanced adenomas (size ≥ 10 mm, villous type, high-grade dysplasia) underwent endoscopic ampullectomy or polypectomy and continued surveillance. MAIN OUTCOME MEASUREMENTS: Detection of advanced adenomas by endoscopy and EUS, endoscopic maintenance of duodenum free of advanced adenoma and cancer. RESULTS: Patients (38 men and 42 women, mean age 32.68 ± 13.60) were followed 7.2 years and underwent 5.36 diagnostic studies on average. Thirty-eight patients had ampullary adenomas. Advanced adenoma was diagnosed by endoscopy in 10 patients. Importantly, EUS upstaged 9 additional patients to advanced adenoma and downstaged 1, thus altering the treatment course in 36% of patients performing EUS. Endoscopic ampullectomy was performed in 15 patients. Adenoma recurred in 10. Five remained nonadvanced and 5 in advanced stages: 3 were successfully retreated endoscopically and 2 ultimately required surgery for residual adenoma. Advanced nonampullary adenomas were successfully resected endoscopically in 23 patients. No patient had duodenal cancer during the study period. LIMITATIONS: Limited follow-up period, young age group, uncontrolled study. CONCLUSIONS: In an intense surveillance program for FAP patients, both endoscopy and EUS were key in accurate selection of advanced adenomas for endoscopic resection. During a 10-year period, only 2 patients required elective surgery and no cancer was observed.
Assuntos
Adenoma/diagnóstico por imagem , Adenoma/patologia , Polipose Adenomatosa do Colo/complicações , Ampola Hepatopancreática , Neoplasias Duodenais/diagnóstico por imagem , Neoplasias Duodenais/patologia , Endoscopia Gastrointestinal , Endossonografia , Recidiva Local de Neoplasia/patologia , Vigilância da População/métodos , Adenoma/cirurgia , Adolescente , Adulto , Ampola Hepatopancreática/cirurgia , Neoplasias Duodenais/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Estudos Retrospectivos , Adulto JovemRESUMO
BACKGROUND AND STUDY AIMS: Although colonoscopy is the "gold standard" for colorectal cancer screening, a significant number of adenomas are still missed during standard colonoscopy, often because they are hidden behind colonic folds and flexures. The aim of this study was to assess the ability of a novel balloon colonoscope (G-EYE endoscope; Smart Medical Systems, Ra'anana, Israel) to increase adenoma detection and reduce the miss rate compared with standard colonoscopy. PATIENTS AND METHODS: This was a multicenter, randomized, prospective, controlled study in patients (ageâ≥â40 years) undergoing colonoscopy for screening or diagnostic work-up (including surveillance). Patients underwent same-day, back-to-back tandem colonoscopy. Patients in Group A underwent standard colonoscopy followed by balloon colonoscopy, and patients in Group B underwent balloon colonoscopy followed by the standard technique. The adenoma detection and miss rates were compared between the two colonoscopy procedures. RESULTS: A total of 126 patients were enrolled and randomized into Group A (nâ=â60) or Group B (nâ=â66). The adenoma miss rate of balloon colonoscopy was significantly lower than that of standard colonoscopy (7.5â% vs. 44.7â%; Pâ=â0.0002). The detection of additional adenomas by balloon colonoscopy was significant (81.0â%; Pâ=â0.0002), in particular, the relative amount of adenomas detected in the ascending colon by balloon colonoscopy was 41â% versus 14â% for standard colonoscopy. CONCLUSIONS: A novel balloon colonoscopy technique detected significantly more adenomas than standard colonoscopy, and missed fewer adenomas. Balloon colonoscopy has the potential to increase the effectiveness of colorectal cancer screening and surveillance colonoscopy.
Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Colonoscópios , Colonoscopia/instrumentação , Adenoma/patologia , Idoso , Colo Ascendente , Neoplasias do Colo/patologia , Colonoscopia/métodos , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-CegoRESUMO
OBJECTIVES: The aim was to present the workup of patients with acute recurrent pancreatitis (ARP) for genetic analysis and electrophysiological testing. METHODS: Patients with ARP with unknown etiology were referred for genetic testing and evaluation of cystic fibrosis transmembrane conductor regulator (CFTR) function by nasal potential difference (NPD) testing. RESULTS: A total of 67 patients were evaluated. The mean age was 23â±â17 years (median 17.0 years, range 1.5-72 years); 90% were Jewish and 10% Arab. Ten (15%) patients carried PRSS1 gene mutation (K23R(7), R122H(2), and D21A(1)). One patient had K172E/- (chymotrypsin C [CTRC]) mutation, 1 had I42M (serine protease inhibitor Kazal type 1 [SPINK1])/V235I (CTRC) together with ΔF508/5T, 1 patient had R67H (SPINK1)/V235I (CTRC), and 1 patient had V235I (CTRC)/-. Ten of 67 (15%) patients submitted for CFTR gene testing carried mutations (ΔF508/L997F, ΔF508/5T(11TG), W1282/5T(12TG), W1282X/Y1014C, ΔF508/R31C, R117H/-, R117H/Y1014C, D1152H/-, 5T(11TG)/-, and L997F/-). Fifty-four (80%) patients underwent sweat testing. Of these, 5 had sweat chloride ≥60 mEq/L, and 22 patients had sweat chloride from 40 to 60 mEq/L. Of the 56 (83%) patients had nasal potential difference testing, 4 (6%) with abnormal results. CONCLUSIONS: One-third (34%) of patients with ARP carry mutations for hereditary pancreatitis including rare mutations (K23R), and 12.5% have evidence of cftr mutations and 10% had CFTR dysfunction underscoring the importance of genetic and functional workup of these patients.
Assuntos
Nariz/fisiopatologia , Pancreatite/genética , Pancreatite/fisiopatologia , Mucosa Respiratória/fisiopatologia , Doença Aguda , Adolescente , Adulto , Idoso , Árabes/genética , Proteínas de Transporte/genética , Criança , Pré-Escolar , Cloretos/análise , Quimotripsina/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Fenômenos Eletrofisiológicos , Feminino , Humanos , Lactente , Israel , Judeus/genética , Masculino , Potenciais da Membrana , Pessoa de Meia-Idade , Pancreatite/etnologia , Recidiva , Suor/química , Tripsina/genética , Inibidor da Tripsina Pancreática de Kazal , Adulto JovemRESUMO
BACKGROUND: Although colonoscopy is the accepted standard for detection of colorectal adenomas and cancers, many adenomas and some cancers are missed. To avoid interval colorectal cancer, the adenoma miss rate of colonoscopy needs to be reduced by improvement of colonoscopy technique and imaging capability. We aimed to compare the adenoma miss rates of full-spectrum endoscopy colonoscopy with those of standard forward-viewing colonoscopy. METHODS: We did an international, multicentre, randomised trial at three sites in Israel, one site in the Netherlands, and two sites in the USA between Feb 1, 2012, and March 31, 2013. Patients aged 18-70 years referred for colorectal cancer screening, polyp surveillance, or diagnostic assessment underwent same-day, back-to-back tandem colonoscopy with standard forward-viewing colonoscope and the full-spectrum endoscopy colonoscope. The patients were randomly assigned (1:1), via computer-generated randomisation with block size of 20, to which procedure was done first. The endoscopist was masked to group allocation until immediately before the start of colonoscopy examinations; patients were not masked. The primary endpoint was adenoma miss rates. We did per-protocol analyses. This trial is registered with ClinicalTrials.gov, number NCT01549535. FINDINGS: 197 participants were enrolled. 185 participants were included in the per-protocol analyses: 88 (48%) were randomly assigned to receive standard forward-viewing colonoscopy first, and 97 (52%) to receive full-spectrum endoscopy colonoscopy first. By per-lesion analysis, the adenoma miss rate was significantly lower in patients in the full-spectrum endoscopy group than in those in the standard forward-viewing procedure group: five (7%) of 67 vs 20 (41%) of 49 adenomas were missed (p<0·0001). Standard forward-viewing colonoscopy missed 20 adenomas in 15 patients; of those, three (15%) were advanced adenomas. Full-spectrum endoscopy missed five adenomas in five patients in whom an adenoma had already been detected with first-pass standard forward-viewing colonoscopy; none of these missed adenomas were advanced. One patient was admitted to hospital for colitis detected at colonoscopy, whereas five minor adverse events were reported including vomiting, diarrhoea, cystitis, gastroenteritis, and bleeding. INTERPRETATION: Full-spectrum endoscopy represents a technology advancement for colonoscopy and could improve the efficacy of colorectal cancer screening and surveillance. FUNDING: EndoChoice.
Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Adolescente , Adulto , Idoso , Humanos , Pessoa de Meia-IdadeRESUMO
BACKGROUND & AIMS: Non-alcoholic fatty liver disease (NAFLD) is associated with increased cardiovascular disease (CVD) risk. Non-high-density lipoprotein cholesterol (non-HDL-C), i.e. total cholesterol minus HDL, is a well-established risk factor for CVD; however, its association with NAFLD development has not been established. Our aim was to test whether non-HDL-C is an independent predictor of new onset of NAFLD. METHODS: A prospective cohort study of 213 subjects from the general population, without liver disease, was studied. Evaluation of medical history, dietary and physical activity habits, fasting blood tests and ultrasonographic evidence of NAFLD was performed at baseline and after a 7-year follow-up by identical protocols. RESULTS: From 147 patients that did not have NAFLD at baseline, 28 (19%) developed NAFLD at the 7-year follow-up. The baseline levels of non-HDL-C were higher among subjects who developed NAFLD (179.5 ± 37.1 vs. 157.3 ± 35.1 mg/dl, P = 0.003). Non-HDL-C independently predicted new onset of NAFLD adjusting for age, gender, BMI or waist circumference, lifestyle and serum insulin (OR = 1.02 for every mg/dl increment, 1.01-1.04 95% CI, P = 0.008). Non-HDL-C was a stronger predictor for NAFLD than total cholesterol, low-density lipoprotein cholesterol, triglycerides and HDL. No patients with non-HDL-C < 130 mg/dl developed NAFLD, whereas 20.8% of those with values between 130 to 160 and 24.6% of those with values >160 mg/dl developed NAFLD (P for trend = 0.015). CONCLUSIONS: Non-HDL-C is an independent predictor for NAFLD and a stronger predictor than other lipoproteins. This association may stem from the combined hepato-toxic effect of non-HDL-C and may explain the association between NAFLD and CVD.
Assuntos
Colesterol/sangue , Dislipidemias/epidemiologia , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Adulto , Idoso , Biomarcadores/sangue , Distribuição de Qui-Quadrado , HDL-Colesterol/sangue , Dislipidemias/sangue , Dislipidemias/diagnóstico , Feminino , Humanos , Incidência , Israel , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Hepatopatia Gordurosa não Alcoólica/sangue , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Regulação para Cima , Adulto JovemRESUMO
BACKGROUND: Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed. OBJECTIVE: To compare forward-viewing with ultrawide-viewing colonoscopy in the detection of simulated colon polyps in an in vitro colon model. DESIGN: Prospective, multicenter. SETTING: Six endoscopy units (3 in the United States and 3 in Israel). PATIENTS: In vitro colon model with simulated colon polyps (n = 21 metallic beads). INTERVENTIONS: Detection of simulated colon polyps on colonoscope withdrawal. MAIN OUTCOME MEASUREMENTS: Incremental detection of simulated colon polyps and endoscopist evaluation of the usability, visibility, and maneuverability of ultrawide-viewing colonoscopy. RESULTS: On forward-viewing colonoscopy, the number of simulated polyps (mean ± standard deviation) detected per endoscopist was 11.1 ± 2.3 polyps, a 52.9% detection rate. Simulated polyp detection rates per colon segment were 3.0 ± 0.93 (60.0%) right colon, 2.4 ± 0.87 (48.0%) transverse colon, and 5.7 ± 1.5 (51.8%) left colon. On ultrawide-viewing colonoscopy, the simulated polyp detection rate per endoscopist significantly increased to 18.0 ± 1.98 polyps, an overall 85.7% polyp detection rate (P < .001). Simulated polyp detection rates were also significantly higher by using the ultrawide-viewing mode in each colon segment, 4.5 ± 0.65 polyps (90.0%) right colon, 4.0 ± 0.87 (80.0%) polyps transverse colon, and 9.6 ± 1.28 polyps (87.3%) left colon (all comparisons, P < .001). Importantly, the ultrawide-viewing mode detected significantly more "hidden" simulated polyps (81.9% vs 31.9%, P < .0001). LIMITATIONS: Nonrandomized design, use of a colon model, and "simulated" colon polyps. CONCLUSIONS: Ultrawide-view colonoscopy significantly improved simulated polyp detection in a colon model. Clinical studies in human subjects should be pursued to further evaluate this new endoscopic technology.
Assuntos
Pólipos do Colo/diagnóstico , Colonoscópios , Colonoscopia/métodos , Adulto , Atitude do Pessoal de Saúde , Competência Clínica , Colonoscopia/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Dispositivos Ópticos , Estudos ProspectivosRESUMO
BACKGROUND AND STUDY AIMS: Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed with this technique. We aimed to establish the feasibility, usability, and safety of a novel colonoscopy platform featuring full-spectrum endoscopy (FUSE). PATIENTS AND METHODS: This was a prospective, single-center pilot and feasibility study. In total, 50 individuals, ages 18 - 70 years, underwent colonoscopy featuring FUSE (up to 330° field of view) for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. Study end points included success of cecal intubation, time to cecal intubation, withdrawal time, total procedure time, success of therapeutic interventions, adverse events, and endoscopists' subjective evaluation of FUSE. RESULTS: Cecal intubation was achieved in 50/50 individuals (100 %). Time to cecum (minutes, mean ± SD) was 3.1 ± 1.5 minutes, withdrawal time 12.7 ± 4.4 minutes, and total procedure time 15.3 ± 4.6 minutes. In 22/50 cases (44 %), 26 therapeutic interventions were performed: 19 (73.1 %) biopsies and 7 (26.9 %) polypectomies. No acute or delayed adverse events were observed. Patient satisfaction and endoscopist subjective evaluation were high. CONCLUSIONS: A colonoscopy platform featuring full-spectrum endoscopy appears feasible, usable, and safe. These results represent an important advance in colonoscopy imaging technology and should be further pursued in comparative human studies.
Assuntos
Adenoma/diagnóstico , Ceco , Colonoscopia/instrumentação , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Intubação , Adenoma/cirurgia , Adolescente , Adulto , Idoso , Atitude do Pessoal de Saúde , Colonoscopia/efeitos adversos , Neoplasias Colorretais/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Satisfação do Paciente , Projetos Piloto , Fatores de Tempo , Adulto JovemRESUMO
BACKGROUND & AIMS: Non-alcoholic fatty liver disease (NAFLD) is suspected to confer an increased risk for developing type 2 diabetes (DM). However, only a few prospective studies evaluated NAFLD as a predictor for DM, most did not adjust for the full range of potential cofounders and none used an objectively quantified degree of steatosis. Our aim was to evaluate the independent role of NAFLD in predicting the development of pre-DM in a 7-year prospective follow-up of healthy volunteers. METHODS: A prospective cohort of a subsample of the Israeli National Health Survey evaluated at baseline and after 7 years by identical protocols. Metabolic parameters and ultrasonographic evidence of NAFLD were evaluated in 213 subjects, without known liver disease or history of alcohol abuse. Exclusion criteria were pre-DM at the baseline survey. Steatosis was quantified by ultrasound with the hepato-renal ultrasound index (HRI). RESULTS: The study included 141 volunteers (mean age 48.78 ± 9.68, 24.82% with NAFLD) without pre-DM/DM at baseline. Both NAFLD on regular US (OR=2.93, 1.02-8.41 95%CI) and HRI (OR=7.87, 1.83-33.82) were independent predictors for the development of pre-DM, adjusting for age, gender, BMI, family history of DM, baseline insulin, adiponectin and glucose. Further adjustment for physical activity and dietary intake did not weaken the association. Furthermore, NAFLD was a stronger predictor for pre-DM than the metabolic syndrome. Subjects with both NAFLD and glucose ≥89 had 93.3% incidence rate of pre-DM. CONCLUSION: Non-alcoholic fatty liver disease is a strong and independent risk factor for pre-DM in the general adult population; thus, NAFLD patients should be classified as a population at risk.
Assuntos
Fígado Gorduroso/complicações , Fígado Gorduroso/epidemiologia , Estado Pré-Diabético/epidemiologia , Estado Pré-Diabético/etiologia , Adulto , Fígado Gorduroso/diagnóstico por imagem , Seguimentos , Humanos , Incidência , Entrevistas como Assunto , Israel/epidemiologia , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica , Estudos Prospectivos , UltrassonografiaRESUMO
BACKGROUND/AIMS: Rodent obesity models have been shown to display impaired bile secretory functions. We have shown that glucagon-like peptide 1 (GLP-1) attenuates hepatic lipogenesis, and in the present study we investigated whether GLP-1 also improves high fat diet-associated cholestatic injury. METHODS: Wild type (WT) and dipeptidyl peptidase 4-deficient rats (DPP4-) with chronic elevated serum levels of active GLP-1 were fed regular chow and a Western diet for 2 months. Primary hepatocytes were used to assess GLP-1 effects on mRNA expression and transcription of genes encoding bile acid synthesis enzymes and transporters. RESULTS: DPP4- exhibited attenuated liver injury as expressed by lower serum AST and ALT after 2 months of a Western diet. In addition, DPP4- had better insulin sensitivity, lower serum triglycerides, cholesterol and bile acids. Hepatic expression of cyp7A1, the rate limiting enzyme in conversion of cholesterol into bile acids, was strongly attenuated in DPP4- fed with a Western diet. Moreover, hepatic expression of bile transporter, ABCB11, was increased, facilitating a higher rate of bile secretion. Mechanistically, we showed that GLP-1 directly reduced basal and LXR-induced cyp7A1 mRNA expression and suppressed cyp7A1 transcription in transient transfection assays in primary hepatocytes. However, GLP-1 and its analog exendin 4 also induced mRNA expression of bile acid transporter ABCC3 in primary rat hepatocyte cultures. CONCLUSIONS: Our data suggest that GLP-1 analogs may serve as a novel therapeutic drug to alleviate obesity-induced liver injury by reducing bile acid synthesis and improving liver bile secretory function.
Assuntos
Bile/metabolismo , Gorduras na Dieta/efeitos adversos , Dipeptidil Peptidase 4/metabolismo , Fígado Gorduroso/metabolismo , Membro 11 da Subfamília B de Transportadores de Cassetes de Ligação de ATP , Transportadores de Cassetes de Ligação de ATP/genética , Transportadores de Cassetes de Ligação de ATP/metabolismo , Animais , Colesterol 7-alfa-Hidroxilase/genética , Colesterol 7-alfa-Hidroxilase/metabolismo , Dieta , Dipeptidil Peptidase 4/genética , Fígado Gorduroso/induzido quimicamente , Deleção de Genes , Regulação da Expressão Gênica/fisiologia , Peptídeo 1 Semelhante ao Glucagon/análogos & derivados , Peptídeo 1 Semelhante ao Glucagon/farmacologia , Hipolipemiantes/farmacologia , Masculino , Hepatopatia Gordurosa não Alcoólica , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Ratos , Ratos Endogâmicos F344 , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase ReversaRESUMO
The association between intraductal papillary mucinous neoplasms (IPMNs) and extra-pancreatic malignancies is controversial. This cross-sectional study compared esophagogastroduodenal findings in 340 IPMN patients to those of age- and gender-matched controls without known IPMNs who underwent esophagogastroduodenoscopies (EGDs) for similar clinical reasons. The presence of gastric and esophageal cancer, Barrett's esophagus, neuroendocrine tumors (NETs), gastrointestinal stromal tumors (GISTs), gastric adenomas, and ampullary tumors was assessed. The results showed that 4/340 (1.2%) of the IPMN patients had gastric cancer and 1/340 (0.3%) had esophageal cancer. The matched control group had a similar incidence of gastric cancer (5/340) (1.5%), with no esophageal cancer cases (p > 0.999). The overall incidence of other esophagogastroduodenal conditions did not significantly differ between the IPMN patients and the controls. However, the incidence of gastric cancer in the IPMN patients was higher than expected based on national cancer registry data (standardized incidence ratio of 31.39; p < 0.001; CI 8.38-78.76). In conclusion, IPMN patients have a significantly higher incidence of gastric cancer compared to the general population. However, the incidence of esophagogastroduodenal findings, including gastric and esophageal cancer, is similar between IPMN patients and those who undergo an EGD for similar clinical indications. Further research is needed to determine optimal surveillance strategies for IPMN patients regarding their risk of developing gastric cancer.
RESUMO
Endoscopic ultrasound (EUS) was born from the combination of a high-frequency ultrasound probe with an endoscope to assess in detail the walls of the upper and lower gastrointestinal tract and surrounding organs and structures. The subsequent possibility of EUS-guided tissue acquisition has rapidly established the irreplaceable role of EUS in the management of a wide range of benign and malignant gastrointestinal diseases. The actual diagnostic armamentarium involving fine-Doppler, elastography, and contrast enhancement has significantly improved its diagnostic yield, which could be even more refined by newer ways of interrogating data and images, such as artificial intelligence. Technological development (e.g., new echendoscopes, larger operative channels, special-design needles, lumen apposing metal stents, and dedicated biliary stents) and the clinical need for new, more effective, and less-invasive procedures has rapidly evolved EUS from a purely diagnostic tool to a therapeutic modality, that is making increasingly outdated some surgical or radiological procedures that have hitherto been considered standard of care.
Assuntos
Inteligência Artificial , Gastroenteropatias , Humanos , Gastroenteropatias/diagnóstico por imagem , Gastroenteropatias/terapia , Endossonografia/métodosRESUMO
BACKGROUND: The diagnostic and therapeutic approach to hilar cholangiocarcinoma and thus the prognosis have changed significantly over the last two decades. Nonetheless, hilar cholangiocarcinoma presents a complex surgical challenge. OBJECTIVES: To assess the outcome of the radical approach for the management of types III and IV hilar cholangiocarcinoma. METHODS: We conducted a retrospective single-center study. Preoperative diagnosis was based on ultrasound, computed tomography and selective percutaneous cholangiography without tissue diagnosis. Surgery was radical and included en-bloc liver, extrahepatic biliary tree and hilar lymph nodes resection, followed by biliary reconstruction with hepaticojejunostomy. RESULTS: Fifteen patients (mean age 49 years, range 24-72) were managed accordingly. Anatomic classification of the biliary involvement was Bismuth-Corlette type IIIA (n=4), type IIIB (n=3) and type IV (n=8). The surgical procedures performed included four right hepatic lobectomies, five left hepatic lobectomies and six trisegmentectomies (all extended to the caudate lobe). Complete negative resection margins (RO) were accomplished in 12 cases (80%). Regional lymph node metastases were detected in five cases. There were two perioperative mortalities. Long-term follow-up (mean 30 months, range 6-72) revealed local recurrences in two cases, distant metastases in three, and both local and distant in two cases. Eleven patients are alive and 6 are without evidence of disease. The overall 2- and 5-year survival is 78% and 38% respectively. CONCLUSIONS: In selected patients the aggressive surgical approach to hilar cholangiocarcinoma is justified and can result in long-term survival.