RESUMO
BACKGROUND: Intraaortic balloon pumping is known to be ineffective in severe cardiogenic shock. The efficacy of balloon volumes larger than those commonly used is examined. METHODS: In 18 dogs with severe experimental cardiogenic shock (systolic aortic pressure < 60 mm Hg, aortic flow < 45 mL.min-1.kg-1) the effect of three intraaortic balloon volumes (15, 30, and 45 mL) and a 60-mL paraaortic pump was examined. RESULTS: The 45-mL balloon covering the full length of the aorta induced the highest (+ 12.4 +/- 2.2 mL.min-1.kg-1; mean +/- standard error of the mean) and the 15-mL balloon the lowest increase in aortic flow (F = 14.6, p < 0.0001). Only the 45-mL balloon increased (p < 0.05) urine output and renal artery flow. The 60-mL paraaortic pump induced the highest (F = 10.72, p < 0.002) increase (+ 36.6 +/- 6.5 mL.min-1.kg-1) in aortic flow compared to the three balloons. An 80- to 100-mL paraaortic pump maintained the life of 3 patients in severe cardiogenic shock for 4 hours, 8 days, and 54 days, whereas a 40-mL conventional balloon was completely ineffective. CONCLUSIONS: Experimental and clinical data indicate that the effectiveness of intraaortic balloon pumping in severe cardiogenic shock may be improved by increasing the volume of the balloon (i.e., until it fully occupies the aorta).
Assuntos
Balão Intra-Aórtico/métodos , Choque Cardiogênico/terapia , Animais , Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Cães , Frequência Cardíaca , Humanos , Balão Intra-Aórtico/instrumentação , Artéria Renal/fisiopatologia , Choque Cardiogênico/fisiopatologia , UrinaRESUMO
To evaluate the accuracy of exercise echocardiography for the recognition of coronary artery disease in the presence of left ventricular hypertrophy 70 patients were studied. Significant coronary artery disease was present in 25 patients and left ventricular hypertrophy had 29 patients. All patients underwent an exercise ECG and echocardiographic test during which cine-loop digitized echocardiography was obtained. Wall motion was analyzed and a regional wall motion score index was calculated. The overall sensitivities of exercise ECG and echocardiography for detecting coronary artery disease were 60% and 64%, respectively, and the specificities were 49% and 78%, respectively. In patients with left ventricular hypertrophy the specificity of exercise echocardiography was higher (71%) compared to exercise ECG (21%) while in patients without hypertrophy the sensitivity was higher (70% vs. 40%, respectively). Of the 19 patients with a non-diagnostic stress ECG, echocardiography correctly identified 100% of those with coronary artery disease but only 53% of those without disease. It is concluded that exercise digital echocardiography represents a good diagnostic alternative to the exercise ECG for identifying coronary artery disease in the presence of left ventricular hypertrophy and should be useful in patients with a non-diagnostic exercise ECG.
Assuntos
Doença das Coronárias/diagnóstico , Ecocardiografia/métodos , Teste de Esforço/métodos , Hipertrofia Ventricular Esquerda/complicações , Pressão Sanguínea , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/fisiopatologia , Eletrocardiografia/métodos , Feminino , Humanos , Hipertensão/complicações , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
This work aims to determine optimal balloon shape and volume during left intraventricular balloon pumping (IABP) in the fibrillating dog heart. A balloon volume equal to the left ventricular end-diastolic volume (LVEDV) maintained a higher systolic aortic pressure and flow (106.4 +/- 2.7 mmHg and 84.7 +/- 2.35 ml/kg/min, x +/- SEM, respectively) than a 25% smaller (97.8 +/- 3.3 mmHg, P = 0.002 and 63.7 +/- 4.1 ml/kg/min, P = 0.002, respectively) or a 25% larger balloon (87.4 +/- 2.3 mmHg, P = 0.002 and 70.9 +/- 3.4 ml/kg/min, P = 0.002, respectively). Among 5 different balloon shapes tested, a pear-shaped balloon inflated from the apex to the base of the left ventricle induced the highest (P varying from 0.042 to 0.01, compared to the remaining balloon shapes) systolic aortic pressure and flow (104.6 +/- 4.5 mmHg and 77.9 +/- 1.7 mg/kg/min, respectively). In conclusion, a pear shaped balloon, inflated to a volume equal to the LVEDV, from the apex to the base of the left ventricle, induced an optimal hemodynamic effect during LVBP.
Assuntos
Parada Cardíaca/terapia , Coração Auxiliar/normas , Balão Intra-Aórtico , Análise de Variância , Animais , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Cães , EcocardiografiaRESUMO
This study examines whether a catheter mounted left intraventricular balloon may prevent left ventricular (LV) dysfunction following acute experimental myocardial infarction. In 10 anesthetized pigs, multiple coronary arterial ligations were applied around the apex of the heart. LV end-diastolic pressure (LVEDP), aortic flow (AF), and LV long and short axis fractional shortening (FS) were measured before and at 15 min intervals after ligations. At the 60th min after ligation, the LV long axis FS and AF decreased by 7.2 +/- 2.6% (p < 0.05) and 13.25 +/- 2.68% (p < 0.01), respectively, and the LVEDP increased by 4.3 +/- 1.1 mm Hg (p < 0.01) while no change was noted in the LV short axis FS. An intraventricular catheter mounted nonpulsating balloon was positioned over the endocardium of the infarcted area at the LV apex. Inflation of the nonpulsating balloon to an optimal volume, which was found to be equal to 8-10% of the LV end-diastolic volume, resulted in a reduction (by 3.8 +/- 1.2 mm Hg, p < 0.01) of the already increased LVEDP and in an increase (by 6.6 +/- 2.1%, p < 0.05) in the LV short axis FS while no statistically significant change was noted in the AF and LV long axis FS. It is concluded that an intraventricular catheter mounted balloon patch positioned over the endocardium of the infarcted area may ameliorate early LV dysfunction, possibly by interfering with the functional geometry of the LV contraction.
Assuntos
Cateterismo Cardíaco , Cateterismo , Infarto do Miocárdio/terapia , Disfunção Ventricular Esquerda/prevenção & controle , Animais , Infarto do Miocárdio/complicações , Volume Sistólico , Suínos , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação VentricularRESUMO
A method is presented for maintaining aortic flow by mechanical means during intractable cardiac arrest. A spherical balloon was inserted into the left ventricle while the usual intra-aortic balloon was introduced into the thoracic aorta. Ventricular fibrillation was induced by direct current. The pumps operating the two balloons were adjusted to inflate the intraventricular balloon during one third of the pumping cycle and the intra-aortic balloon during the next two thirds of the same cycle. The intraventricular balloon capacity varied from 40 to 110 ml (six dogs weighing 16-24 kg) while the intra-aortic balloon capacity was 20 ml. An optimal pumping rate of 75 beats/min maintained an aortic flow of 0.9-1.5 ml/beat/kg and a mean pressure into the brachiocephalic trunk of 110 +/- 12.5 mm Hg (mean +/- SD). These experimental data indicate that an easily applied mechanical device system (needing no extracorporeal circulation) may be used to bridge the time between intractable cardiac arrest and implantation of an artificial heart or transplantation.
Assuntos
Parada Cardíaca/terapia , Coração Auxiliar , Balão Intra-Aórtico , Fibrilação Ventricular/terapia , Animais , Cães , EletrocardiografiaRESUMO
The purpose of this study is to evaluate the early morphological and functional abnormalities of the heart in patients with collagen disease. The study population was free of risk factors for coronary artery disease and without any clinically evident cardiac manifestations. In 62 patients with collagen disease (25 with progressive systemic sclerosis, 19 with systemic lupus erythematosus, 15 with rheumatoid arthritis, three with dermatomyositis) and in 40 healthy subjects an echocardiographic study was performed. Echocardiographic examination from the apical four-chamber view was performed at rest and during the end of a 3 min isometric exercise with handgrip. Global and regional ejection fraction of the left ventricle were calculated. In the group with progressive systemic sclerosis the left ventricular mass index was significantly higher than in the control group (110.78 +/- 48.61 vs 82.18 +/- 28.46 g.m-2) and the ejection fraction (53.61 +/- 7.95%) was the lowest of all groups (control: 61.47 +/- 8.52%, systemic lupus erythematosus: 59.04 +/- 8.58%, rheumatoid arthritis: 62.38 +/- 6.88%). Regional ejection fraction analysis revealed a major dysfunction of the proximal segment of the interventricular septum, in all groups. During isometric exercise, the global and regional ejection fraction did not change significantly, although differences between groups disappeared. In rheumatoid arthritis, mitral and aortic valve leaflet separation appeared to be reduced. In the group with systemic lupus erythematosus, mild abnormalities were noticed, although the mean age and duration of the disease were the smallest compared with the other groups. In conclusion, patients with progressive systemic sclerosis mainly present left ventricular hypertrophy with a reduced ejection fraction while rheumatoid arthritis patients show a predominant valve dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)