1.
Echocardiography ; 37(4): 637-640, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32181512

RESUMO

We report commissural fusion as a unique morphologic etiology of early bioprosthetic mitral valve failure in a woman with a history of rheumatic mitral stenosis. She had undergone mitral valve replacement with a 25-mm Edwards Magna Ease bovine pericardial bioprosthesis 3 years earlier and presented with progressive dyspnea. Transesophageal echocardiography revealed severe bioprosthetic stenosis due to commissural fusion. She underwent percutaneous valve-in-valve implantation with a 26-mm Edwards Sapien 3 prosthesis. Marked symptomatic improvement was noted postprocedurally. We speculate that commissural fusion may be a unique pathologic feature of failing bioprosthetic valves in patients with prior rheumatic mitral valve disease.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Cardiopatia Reumática , Animais , Bioprótese/efeitos adversos , Bovinos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/cirurgia , Desenho de Prótese , Falha de Prótese , Cardiopatia Reumática/complicações
2.
Cureus ; 13(9): e18044, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34692277

RESUMO

Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm2/m2. Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29-mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 ± 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period.

3.
J Thromb Thrombolysis ; 24(1): 7-13, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17238005

RESUMO

BACKGROUND: Recent data has suggested that simple (main vessel only) stenting is the preferred approach for patients with bifurcation lesions. We sought to determine the feasibility and outcomes of this approach in a year long inclusive registry. METHODS: From August, 2004-2005, a registry of 1,600 consecutive patients undergoing PCI was reviewed. Patients undergoing PCI for major bifurcation lesions--> or =70% stenosis in a major (> or =2 mm) side branch and/or main vessel--were identified by review of the angiograms. Angiographic, clinical and treatment predictors of final SB compromise (> or =70% stenosis and/or less than TIMI 3 final flow) were identified. RESULTS: Hundred and fifty eight patients who underwent initial stenting of the main vessel with subsequent rescue of the side branch if SB compromise occurred ("Provisional Main Vessel Stenting") comprised the analysis population. Permanent SB compromise occurred in 16% of patients and was associated with an increased risk of large periprocedural MI and renal failure. Independent predictors of permanent SB compromise were lack of pre-PCI beta blockers, presence of diabetes mellitus, main vessel eccentric lesion and small SB vessel diameter. CONCLUSION: Among unselected patients with major bifurcation lesions undergoing a "simple" stenting approach, there is a significant rate of large periprocedural infarction and side branch compromise.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Trombose Coronária/terapia , Infarto do Miocárdio/prevenção & controle , Stents , Idoso , Angina Pectoris/terapia , Angina Instável/terapia , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento