RESUMO
BACKGROUND: Learning to interpret electrocardiograms (ECGs) is a crucial objective in medical education. Despite its importance, errors in ECGs interpretation are common, and the optimal teaching methods have not yet been clearly established. OBJECTIVES: To evaluate students' confidence in ECGs analysis and their opinion on current teaching methods, and to assess the effectiveness of a new ECG educational approach. METHODS: First, we conducted a survey on ECG learning among fourth to sixth-year medical students. Second, a 5-week multicenter comparative study was conducted with fourth-year medical students during their cardiology internship. Two different teaching methods were used, assigned by center. The first group participated in 5-minutes workshops 4 times a week using a "reversed classroom" method, supervised by a cardiologist, where students took turns selecting, presenting and discussing ECGs. The control group attended a single 2-hour face-to-face ECG course. All participants completed a 30-minute ECGs analysis test at baseline and after 5 weeks. RESULTS: Out of 401 survey respondents, the confidence levels in ECG interpretation were 3/5 (IQR 2-3) for routine situations and 2/5 (IQR 1-3) for emergency situations. Satisfaction with ECG teaching was low (2/5, IQR 1-3) and 96.3% of respondents favored more extensive ECG training. In the comparative study, 52 students from 3 medical schools were enrolled (control group: n = 27; workshop group: n = 25). Both groups showed significant improvement in exam scores from baseline to 5-week (33/100 ± 12/100 to 44/100 ± 12/100, p < 0.0001 for the control group and 36/100 ± 13/100 to 62/100 ± 12/100, p < 0.0001 for the workshop group). The improvement was significantly greater in the workshop group compared to the control group (+ 26 ± 11 vs. + 11 ± 6, p < 0.001). CONCLUSIONS: Among French medical students who initially reported low confidence and insufficient skills in ECG interpretation, the workshop approach using a "reversed classroom" method was found to be more effective than conventional lecture-based teaching during cardiology internship.
Assuntos
Competência Clínica , Eletrocardiografia , Estudantes de Medicina , Humanos , Competência Clínica/normas , Educação de Graduação em Medicina/métodos , Cardiologia/educação , Feminino , Masculino , Inquéritos e Questionários , Avaliação Educacional , Internato e ResidênciaRESUMO
Cardiac arrest survivors develop a variety of neuropsychological impairments and neuroanatomical lesions. The goal of this study is to evaluate if brain voxel-based morphometry and lesional Magnetic Resonance Imaging (MRI) analyses performed in the acute phase of an Out-of-Hospital Cardiac Arrest (OHCA) can be sensitive enough to predict the persistence of neuropsychological disorders beyond 3 months. Survivors underwent a prospective brain MRI during the first month after an OHCA and performed neuropsychological assessments at 1 and 3 months. According to the second neuropsychological assessment, survivors were separated into two subgroups, a deficit subgroup with persistent memory, executive functions, attention and/or praxis disorders (n = 11) and a preserved subgroup, disorders free (n = 14). Brain vascular lesion images were investigated, and volumetric changes were compared with healthy controls. Correlations were discussed between brain MRI results, OHCA data and the second neuropsychological assessment. Analyses of acute ischemic lesions did not reveal significant differences between the two subgroups (p = .35), and correlations with cognitive impairments could not be assessed. voxel-based morphometry analyses revealed a global cerebral volume reduction for the two subgroups and a clear decrease of the right thalamic volume for the deficit subgroup. It was associated with a cognitive dysexecutive syndrome represented by four executive indexes according to the 'Groupe de Réflexion pour l'Evaluation des Fonctions EXécutives' criteria. The right thalamus atrophy seems to be more predictive than the vascular lesions and more specific than a global cerebral volume reduction of post-OHCA neuropsychological executive disorders.
Assuntos
Disfunção Cognitiva , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Parada Cardíaca Extra-Hospitalar/complicações , Parada Cardíaca Extra-Hospitalar/patologia , Estudos Prospectivos , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/etiologia , Testes Neuropsicológicos , Imageamento por Ressonância Magnética , Tálamo/diagnóstico por imagem , Tálamo/patologia , CogniçãoRESUMO
AIMS: Left bundle branch area pacing (LBBAP) is a recent technique aiming at preservation of physiological ventricular electrical activation. Our goal was to assess mechanical synchrony parameters in relation to electrocardiographic features during LBBAP performed in routine practice. METHODS AND RESULTS: From June 2020 to August 2021, all patients of our institution with permanent pacemaker implantation indication were eligible for LBBAP. A 'qR' pattern in V1 and a delay from pacing spike to the peak of the R-wave in V6 < 80 ms defined a successful LBBAP. Electrocardiogram and echocardiography were performed during spontaneous rhythm and LBBAP: left ventricular mechanical synchrony (LVMS) parameters using 2D Speckle tracking and interventricular mechanical delay (IVMD) were collected. LBBAP was attempted with success in 134/163 patients (82.2%). During LBBAP, the mean QRS width was 104 ± 12 ms. In patients with left bundle branch block (n = 47), LBBAP provided a significant decrease of QRS width from 139 ± 16 to 105 ± 12 ms (P < 0.001) with reduction of LVMS (53 ± 21 vs. 90 ± 46 ms, P = 0.009), and IVMD (14 ± 13 vs. 49 ± 18 ms, P < 0.001). In patients with right bundle branch block (n = 38), LBBAP led to a significant decrease of QRS width from 134 ± 14 to 106 ± 13 ms (P < 0.001) with no effect on LVMS and a reduction of IVMD (17 ± 14 vs. 50 ± 16 ms, P < 0.001). CONCLUSION: LBBAP in routine practice preserved intra-ventricular mechanical synchrony in patients with narrow and RBBB QRS and improved asynchrony parameters in patients with LBBB.
Assuntos
Bloqueio de Ramo , Estimulação Cardíaca Artificial , Humanos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Eletrocardiografia/métodos , Ecocardiografia/métodos , Arritmias Cardíacas , Fascículo AtrioventricularRESUMO
AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65â min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers. We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique. METHODS: We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators' discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3- and 12-month follow-up. RESULTS: HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0 ± 28.8 min, and 7.3 ± 8.1 min (3.1 ± 4.1 Gy·cm2 ), respectively. The mean HB paced QRS duration was 106 ± 18 ms. The mean HB capture threshold was 1.29 ± 0.77 V and did not increase at 3- and 12-month follow-up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures. CONCLUSION: HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.
Assuntos
Fibrilação Atrial , Fascículo Atrioventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Sistema de Registros , Resultado do TratamentoRESUMO
AIMS: Although cryoenergy safety profile is appropriate for the ablation of arrhythmogenic foci near the conduction system, mapping using the cryoablation catheter is of limited precision. Combining the safety of cryoenergy and the high precision of a 3D mapping system therefore appears the most appropriate set-up for ablation in the vicinity of the His bundle. METHODS AND RESULTS: A 29-year-old woman with a 3-year history of increasing shortness of breath and palpitations refractory to medical treatment was sent to the electrophysiology (EP) laboratory for catheter ablation. Surface electrocardiogram showed sinus rhythm and frequent ectopic beats with narrow QRS complexes similar to those of the sinus beats. The left ventricular ejection fraction was impaired (38%) with no other aetiology found, apart from frequent ectopies. Detailed intracardiac mapping, using a 3D electroanatomical system, revealed that the ectopy originated from the distal His bundle, which was indicated by both antegrade and reversed His bundle activation sequence during ectopy compared to that during sinus rhythm. Due to the proximity of the conduction system, cryoenergy rather than radiofrequency was chosen to target this Hisian ectopy. A special set-up was made in order to allow the cryoablation catheter to be visualized into the 3D mapping system. Cryoenergy delivered to the site of earliest Hisian ectopy activation completely abolished it. CONCLUSION: Such a combined approach may help to improve the therapeutic strategy for ablation procedures with a high risk of injury to the conduction system. It could notably be extended to the ablation of para-Hisian ectopy or accessory pathways.
Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Adulto , Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Feminino , Humanos , Volume Sistólico , Taquicardia , Função Ventricular EsquerdaRESUMO
BACKGROUND: The coronary sinus (CS) is surrounded by a myocardial coat with extensive connections to the left and right atria that contributes to the interatrial electrical connection. Whereas epicardial connections between CS musculature and the left atrium have largely been demonstrated, clinically relevant epicardial connections from the CS musculature toward the low right atrium (LRA) and epicardial connections between two regions of the right atrium remain questionable. METHODS: Five patients underwent electrophysiology (EP) study for typical atrial flutter (AFl) using either conventional multipolar catheters (four patients) or three-dimensional high-density mapping system (one patient). RESULTS: All five patients had a similar sequence of events during the EP studies. After several cavotricuspid isthmus (CTI) radiofrequency (RF) applications, double potentials were recorded along the ablation line while tachycardia persisted. The right atrial activation pattern strongly suggested the presence of a complete endocardial CTI line of the block. Based on the detailed conventional atrial mapping, RF applications at the middle cardiac vein/CS ostium allowed sinus rhythm restoration in four patients. High-density mapping showed an early breakthrough site at the septal side of the ablation line, close to the CS ostium during counterclockwise AFl, in the fifth patient. RF applications at this site resulted in tachycardia termination. CONCLUSION: Our observations suggested the existence of epicardial fibers connecting the LRA with either the CS musculature or a remote right atrial region. When AFl ablation fails whereas evidence for the local endocardial block is observed, the operators should integrate this finding in the diagnosis and ablation strategy.
Assuntos
Flutter Atrial , Ablação por Cateter , Seio Coronário , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Técnicas Eletroquímicas , Endocárdio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , HumanosRESUMO
INTRODUCTION: Either cryoenergy or radiofrequency can be used during atrioventricular nodal reentrant tachycardia (AVNRT) ablation. There are still limited data comparing their respective long-term efficacy (>1 year). This study sought to compare the very long-term outcomes of AVNRT ablation using radiofrequency or cryotherapy. METHODS: We retrospectively included all patients who had undergone a first AVNRT ablation in our institution between January 2010 and December 2017. The primary endpoint was recurrence of documented AVNRT. RESULTS: The study population consisted of 409 patients (274 females; mean age, 49.9 years). Ablation was performed using cryoenergy in 260 patients and radiofrequency in 149. High acute procedural success rate (>98%) was obtained and no permanent AV block was observed using both techniques. During a mean follow-up of 3.3 ± 2.3 years, documented AVNRT recurrence occurred in 24 (9.2%) and 4 patients (2.7%) in the cryoablation (CA) and radiofrequency (RF) group, respectively. The risk of AVNRT recurrence was significantly higher in the CA group as compared with the RF group (hazard ratio [HR] = 3.7; 95% confidence interval [CI], 1.3-5.9). Most of the recurrences after CA occurred between 1- and 6-year follow-up (14/24; 58.3%), with one-third of late recurrences after 3-year follow-up. In multivariable analysis, only Koch's triangle anatomical variant was associated with AVNRT recurrence after CA (HR = 6.7; 95% CI, 2.7-16.3). CONCLUSION: While AVNRT recurrence rates were similar at 1 year of follow-up regardless of the energy used, long-term efficacy appeared higher after radiofrequency ablation. Strikingly, recurrences occured much later after cryotherapy compared with radiofrequency ablation.
Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5â¯months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7â¯years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (nâ¯=â¯113' 45.4%), Enterobacteriaceae (nâ¯=â¯61; 24.6%), Pseudomonas aeruginosa (nâ¯=â¯34; 13.7%), coagulase-negative staphylococci (nâ¯=â¯13; 5.2%), and Candida species (nâ¯=â¯13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; Pâ¯=â¯.031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; Pâ¯=â¯.031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.
Assuntos
Infecções Relacionadas a Cateter/etiologia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , França/epidemiologia , Ventrículos do Coração , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de RiscoRESUMO
The delay between cardiac arrest and brain MRI is usually extremely different in the few cerebral imaging studies assessing the affected brain areas. We report an unusual case of loss of psychic self-activation appeared immediately after a cardiac arrest in a middle age patient. The first brain MRI, one month after the vascular event, did not show the classical lesions typically reported, such as lesion of the caudate nucleus or the globus pallidus. Two years later, although the cognitive performances of our patient were improved, a second brain MRI demonstrated bilateral pallidal lesions, suggesting a possible mechanism with delayed hypoxic lesions.
Assuntos
Apatia , Transtornos Cognitivos/etiologia , Globo Pálido/patologia , Parada Cardíaca Extra-Hospitalar/complicações , Globo Pálido/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND: One of the most frequent complications of transcatheter aortic valve implantation (TAVI) is the occurrence of atrioventricular (AV) conduction disorders secondary to AV node or His bundle injury leading to permanent pacemaker implantation (PPI). The objective was to quantify the rate of ventricular pacing (VP), according to post-TAVI indication for PPI using recorded pacemaker memory. METHODS: From October 2009 to January 2017' all patients who had PPI following TAVI performed at Rouen University Hospital were included. Indications for PPI were: ≥ 1 episode of complete atrioventricular block (CAVB) or 2:1 atrioventricular block, and new-onset persistent left bundle branch block (NOP-LBBB) with either prolonged PR interval (> 200 ms) or HV interval (>70 ms). The primary endpoint was VP percentage at the first pacemaker interrogation (a VP percentage ≥ 1% was considered as significant). RESULTS: Out of 936 TAVI patients (Sapien-3' n = 379 [Edwards Lifesciences, Irvine, CA, USA]; Sapien-XT' n = 513; CoreValve' n = 44, Medtronic, Minneapolis, MN, USA), 87 (9.3%) had PPI. Eighty of these 87 patients were followed-up and analyzed. At the first pacemaker interrogation, a significant VP percentage was observed in 60/80 followed-up patients (75%), in 46/51 patients (90.2%) implanted for CAVB, and 12/23 patients (52.2%) implanted for NOP-LBBB associated with either prolonged PR or HV interval. No clinical predictive factor of significant VP percentage was found. CONCLUSION: In the post-TAVI period, our data support PPI in patients with CAVB even if paroxysmal. Our data also suggest PPI may be considered in patients with NOP-LBBB associated with either prolonged PR or HV interval.
Assuntos
Bloqueio Atrioventricular/prevenção & controle , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/fisiopatologiaRESUMO
Sofosbuvir and daclatasvir are direct-acting antiviral drugs used to treat chronic hepatitis C virus infection. In 2015, the Food and Drug Administration and European Medical Agency warned that bradycardia could occur when amiodarone was administered in combination with sofosbuvir, but no case reports had been published. We report extreme bradycardia within 2 hrs after intake of sofosbuvir and daclatasvir by 2 patients receiving amiodarone. The first patient had a cardiac asystole 30 min after receiving sofosbuvir and daclatasvir. Amiodarone, sofosbuvir, and daclatasvir treatment were stopped; after 10 days, the cardiac evaluation was normal and patient was discharged. The second patient was taking amiodarone and propranolol; 2 hrs after receiving sofosbuvir and daclatasvir, he had an extreme sinus node dysfunction (heart rate of 27beats/min). Amiodarone and propranolol were stopped, but the patient continued receiving sofosbuvir and daclatasvir for 3 days and sinus bradycardia was recorded each day, 2 hrs after intake of these drugs. When he stopped taking the drugs, no bradycardia was observed. Administration of sofosbuvir and daclatasvir on day 13 induced bradycardia 2 hrs after intake. However, no bradycardia occurred following a rechallenge 8 weeks after the patient stopped taking amiodarone. These observations indicate that patients treated with amiodarone should be continuously monitored within the first 48 hrs following the initiation of sofosbuvir and daclatasvir.
Assuntos
Amiodarona/administração & dosagem , Bradicardia/induzido quimicamente , Quimioterapia Combinada/efeitos adversos , Eletrocardiografia , Imidazóis/efeitos adversos , Sofosbuvir/efeitos adversos , Antivirais/administração & dosagem , Antivirais/efeitos adversos , Bradicardia/diagnóstico , Carbamatos , Feminino , Humanos , Imidazóis/administração & dosagem , Masculino , Pessoa de Meia-Idade , Pirrolidinas , Sofosbuvir/administração & dosagem , Fatores de Tempo , Valina/análogos & derivados , Vasodilatadores/administração & dosagemRESUMO
BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , RecidivaRESUMO
BACKGROUND: Pacemaker implantation combined with atrioventricular node ablation (AVNA) is a well-established strategy for uncontrolled atrial arrhythmias. Limited data are available regarding His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) in this setting. AIM: To compare the outcomes of HBP and LBBAP in patients undergoing pacemaker implantation combined with AVN in routine clinical practice. METHODS: We prospectively included all patients who underwent AVNA after successful conduction system pacing (CSP) in two hospitals between September 2017 and May 2023. The primary outcome was the 1-year composite of first episode of heart failure hospitalization, symptomatic atrioventricular node reconduction requiring a second AVNA procedure, lead revision or death from any cause. RESULTS: A total of 164 patients underwent AVNA following successful CSP (68 HBP and 96 LBBAP). Mean pacemaker implantation and AVNA procedure times were shorter in the LBBAP group than the HBP group (46±18 vs 59±23min; P<0.001 and 31±12 vs 43±22min, respectively; P<0.001). Complete atrioventricular block was more frequently obtained in the LBBAP group (88/96 patients [92%] vs 54/68 patients [79%]; P=0.04). One-year freedom from the composite outcome was more frequent in the LBBAP group (89.7% vs 72.9%; hazard ratio 0.32, 95% confidence interval 0.14-0.72; P=0.01). The strategy was similarly effective in both groups with a significant improvement in NYHA class and left ventricular ejection fraction. A secondary pacing threshold elevation >1V occurred only in the HBP group (11%). CONCLUSION: In this prospective, comparative study, LBBAP provided better 1-year outcomes than HBP.
Assuntos
Nó Atrioventricular , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Masculino , Feminino , Fascículo Atrioventricular/fisiopatologia , Idoso , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Resultado do Tratamento , Fatores de Tempo , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Frequência Cardíaca , Fatores de Risco , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Idoso de 80 Anos ou mais , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Potenciais de AçãoRESUMO
BACKGROUND: Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM: To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS: All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS: Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION: In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Prospectivos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , RecidivaRESUMO
BACKGROUND: The role of cryoballoon pulmonary vein isolation for the treatment of atrial fibrillation (AF) is unclear. METHODS AND RESULTS: In a 61-year-old man with persistent AF and severe mitral valve regurgitation, surgical cryoballoon pulmonary vein isolation was performed during open-heart surgery, without complication. CONCLUSION: Surgical cryoballoon ablation is feasible and can effectively isolate PV.
Assuntos
Angioplastia com Balão/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Crioterapia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
BACKGROUND: To gain further insights into mechanisms leading to atrial fibrillation (AF) recurrence after a first ablation procedure using cryoballoon technique, the data collected during redo procedure were analyzed. METHODS AND RESULTS: From a total of 112 patients who underwent cryoballoon pulmonary vein isolation (PVI) for paroxysmal AF, 44 had a second ablation procedure using radiofrequency catheter, because of recurrent atrial arrhythmia. PV reconduction was observed in 109 of the 171 initially isolated veins (64%). Conduction recovery was found, respectively, at the left inferior PV, right inferior PV, right superior PV and left superior PV in 35 patients (80%), 26 patients (67%), 23 patients (52%) and 17 patients (39%). The mean number of reconnected PVs per patient was significantly lower with the 23-mm cryoballoon as compared to the 28-mm. Conduction gaps were focal and located at inferior parts of inferior veins and at the ridge between left atrial appendage and left veins. Mean procedure and fluoroscopy time were 109 ± 32 min and 14.7 ± 8.3 min, respectively. A 3-D mapping system was used in only 8 patients (18%). CONCLUSIONS: Atrial arrhythmia recurrences following cryoballoon PVI were associated with focal PV reconnections, occurring at preferential anatomical sites. These gaps were readily ablated with focal radiofrequency delivery, explaining the lack of need of 3-D mapping system and short procedure time. These results do not support the use of cryoballoon to perform redo procedures.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
AIMS: There are currently limited therapeutic approaches for patients with heart failure with preserved ejection fraction (HFpEF) who have developed permanent atrial fibrillation (AF). We aimed to analyse the impact of ventricular irregularity on heart failure rehospitalization in patients with permanent AF and HFpEF. METHODS AND RESULTS: All 24 h ambulatory Holter monitoring performed in our centre within a month after a first heart failure hospitalization were screened. Patients with HFpEF and permanent AF were included in the retrospective analysis. The following parameters of ventricular irregularity were calculated over the 24 h recording period: standard deviation of all RR intervals (SDNN), coefficient of variation of SDNN (CV-SDNN = SDNN/mean RR), root of the mean squared differences of successive RR intervals (RMSSD), and percentage of consecutive RR intervals with difference over 50 ms (pNN50). The primary endpoint was rehospitalization for acute heart failure (HFrH). From 2010 to 2021, 51/216 screened patients were included. During a median follow-up of 3.13 years, 29/51 patients reached the primary endpoint. HFrH patients had higher SDNN (205 ± 65 vs. 154 ± 46 ms; P < 0.01), CV-SDNN (26 ± 8% vs. 19 ± 5%, P < 0.01), RMSSD (182 ± 47 vs. 138 ± 65 ms, P = 0.013), and pNN50 (76 ± 9 vs. 58 ± 26, P < 0.001) when compared with patients with no HFrH. In multivariate analysis, all those parameters remained significantly associated with HFrH. CONCLUSIONS: In this pilot study, we found some evidences for a deleterious impact of excessive ventricular irregularity on HFrH in AF patients with HFpEF. Those new findings could pave the way for new prognosis and therapeutic approaches in this patients' population.
Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Volume Sistólico , Readmissão do Paciente , Frequência Cardíaca , Estudos Retrospectivos , Projetos PilotoRESUMO
BACKGROUND: His-bundle pacing (HBP) is an appealing alternative to right ventricular pacing in patients referred for permanent ventricular pacing and atrioventricular nodal ablation (AVNA) because it preserves physiological ventricular activation. Only limited data regarding HBP combined with AVNA are available in the literature. OBJECTIVE: The purpose of this study was to provide further evidence on the feasibility and efficacy of this therapeutic approach in patients with uncontrolled atrial arrhythmia. METHODS: We prospectively included all patients who had undergone AVNA after HBP in 3 different hospitals between 2017 and 2022. RESULTS: AVNA following HBP lead implantation was performed in 75 patients. Complete atrioventricular (AV) block was obtained in 58 patients (77%), and significant modulation of AV nodal conduction (heart rate <60 bpm) was obtained in 12 patients (16%). AVNA failure was observed in 5 patients (7%). Recording of an atrial signal by the HBP lead was more frequently observed in patients with AVNA modulation/failure than in patients with complete AV block (11/17 vs 5/58; P <.001). No lead dislodgment occurred during the AVNA procedures. Acute His-bundle (HB) capture threshold increase >1 V occurred in 11 patients (15%), with return to baseline value on day 1 in 9 patients. New York Heart Association functional class and left ventricular ejection fraction significantly improved from baseline to last follow-up (3.0 ± 0.7 vs 1.6 ± 0.5; P <.001; and 47% ± 14% vs 60% ± 9%; P <.0001, respectively). CONCLUSION: AVNA combined with HBP for noncontrolled atrial arrhythmia was feasible and clinically efficient. Implanting the HB lead on the ventricular aspect of the tricuspid annulus avoiding atrial signal recording can facilitate AVNA.