Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 24(12): 1387-1398, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38039992

RESUMO

BACKGROUND: Stereotactic body radiotherapy (SBRT) has the potential to ablate localised pancreatic ductal adenocarcinoma. Selective dismutase mimetics sensitise tumours while reducing normal tissue toxicity. This trial was designed to establish the efficacy and toxicity afforded by the selective dismutase mimetic avasopasem manganese when combined with ablative SBRT for localised pancreatic ductal adenocarcinoma. METHODS: In this adaptive, randomised, double-blind, placebo-controlled, phase 1b/2 trial, patients aged 18 years or older with borderline resectable or locally advanced pancreatic cancer who had received at least 3 months of chemotherapy and had an Eastern Cooperative Oncology Group performance status of 0-2 were enrolled at six academic sites in the USA. Eligible patients were randomly assigned (1:1), with block randomisation (block sizes of 6-12) with a maximum of 24 patients per group, to receive daily avasopasem (90 mg) or placebo intravenously directly before (ie, within 180 min) SBRT (50, 55, or 60 Gy in five fractions, adaptively assigned in real time by Bayesian estimates of 90-day safety and efficacy). Patients and physicians were masked to treatment group allocation, but not to SBRT dose. The primary objective was to find the optimal dose of SBRT with avasopasem or placebo as determined by the late onset EffTox method. All analyses were done on an intention-to-treat basis. This study is registered with ClinicalTrials.gov, NCT03340974, and is complete. FINDINGS: Between Jan 25, 2018, and April 29, 2020, 47 patients were screened, of whom 42 were enrolled (median age was 71 years [IQR 63-75], 23 [55%] were male, 19 [45%] were female, 37 [88%] were White, three [7%] were Black, and one [2%] each were unknown or other races) and randomly assigned to avasopasem (n=24) or placebo (n=18); the placebo group was terminated early after failing to meet prespecified efficacy parameters. At data cutoff (June 28, 2021), the avasopasem group satisfied boundaries for both efficacy and toxicity. Late onset EffTox efficacy response was observed in 16 (89%) of 18 patients at 50 Gy and six (100%) of six patients at 55 Gy in the avasopasem group, and was observed in three (50%) of six patients at 50 Gy and nine (75%) of 12 patients at 55 Gy in the placebo group, and the Bayesian model recommended 50 Gy or 55 Gy in five fractions with avasopasem for further study. Serious adverse events of any cause were reported in three (17%) of 18 patients in the placebo group and six (25%) of 24 in the avasopasem group. In the placebo group, grade 3 adverse events within 90 days of SBRT were abdominal pain, acute cholangitis, pyrexia, increased blood lactic acid, and increased lipase (one [6%] each); no grade 4 events occurred. In the avasopasem group, grade 3-4 adverse events within 90 days of SBRT were acute kidney injury, increased blood alkaline phosphatase, haematoma, colitis, gastric obstruction, lung infection, abdominal abscess, post-surgical atrial fibrillation, and pneumonia leading to respiratory failure (one [4%] each).There were no treatment-related deaths but one late death in the avasopasem group due to sepsis in the setting of duodenal obstruction after off-study treatment was reported as potentially related to SBRT. INTERPRETATION: SBRT that uses 50 or 55 Gy in five fractions can be considered for patients with localised pancreatic ductal adenocarcinoma. The addition of avasopasem might further enhance disease outcomes. A larger phase 2 trial (GRECO-2, NCT04698915) is underway to validate these results. FUNDING: Galera Therapeutics.


Assuntos
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Radiocirurgia , Humanos , Masculino , Feminino , Idoso , Adenocarcinoma/radioterapia , Adenocarcinoma/tratamento farmacológico , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/tratamento farmacológico , Radiocirurgia/efeitos adversos , Teorema de Bayes , Carcinoma Ductal Pancreático/radioterapia , Carcinoma Ductal Pancreático/tratamento farmacológico , Método Duplo-Cego , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
2.
JNCI Cancer Spectr ; 8(3)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38730548

RESUMO

BACKGROUND: Traditional constraints specify that 700 cc of liver should be spared a hepatotoxic dose when delivering liver-directed radiotherapy to reduce the risk of inducing liver failure. We investigated the role of single-photon emission computed tomography (SPECT) to identify and preferentially avoid functional liver during liver-directed radiation treatment planning in patients with preserved liver function but limited functional liver volume after receiving prior hepatotoxic chemotherapy or surgical resection. METHODS: This phase I trial with a 3 + 3 design evaluated the safety of liver-directed radiotherapy using escalating functional liver radiation dose constraints in patients with liver metastases. Dose-limiting toxicities were assessed 6-8 weeks and 6 months after completing radiotherapy. RESULTS: All 12 patients had colorectal liver metastases and received prior hepatotoxic chemotherapy; 8 patients underwent prior liver resection. Median computed tomography anatomical nontumor liver volume was 1584 cc (range = 764-2699 cc). Median SPECT functional liver volume was 1117 cc (range = 570-1928 cc). Median nontarget computed tomography and SPECT liver volumes below the volumetric dose constraint were 997 cc (range = 544-1576 cc) and 684 cc (range = 429-1244 cc), respectively. The prescription dose was 67.5-75 Gy in 15 fractions or 75-100 Gy in 25 fractions. No dose-limiting toxicities were observed during follow-up. One-year in-field control was 57%. One-year overall survival was 73%. CONCLUSION: Liver-directed radiotherapy can be safely delivered to high doses when incorporating functional SPECT into the radiation treatment planning process, which may enable sparing of lower volumes of liver than traditionally accepted in patients with preserved liver function. TRIAL REGISTRATION: NCT02626312.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Fígado , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Radioterapia Guiada por Imagem/métodos , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Tamanho do Órgão , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto
3.
Mol Imaging Biol ; 25(6): 991-1019, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845582

RESUMO

Critical advances in radionuclide therapy have led to encouraging new options for cancer treatment through the pairing of clinically useful radiation-emitting radionuclides and innovative pharmaceutical discovery. Of the various subatomic particles used in therapeutic radiopharmaceuticals, alpha (α) particles show great promise owing to their relatively large size, delivered energy, finite pathlength, and resulting ionization density. This review discusses the therapeutic benefits of α-emitting radiopharmaceuticals and their pairing with appropriate diagnostics, resulting in innovative "theranostic" platforms. Herein, the current landscape of α particle-emitting radionuclides is described with an emphasis on their use in theranostic development for cancer treatment. Commonly studied radionuclides are introduced and recent efforts towards their production for research and clinical use are described. The growing popularity of these radionuclides is explained through summarizing the biological effects of α radiation on cancer cells, which include DNA damage, activation of discrete cell death programs, and downstream immune responses. Examples of efficient α-theranostic design are described with an emphasis on strategies that lead to cellular internalization and the targeting of proteins involved in therapeutic resistance. Historical barriers to the clinical deployment of α-theranostic radiopharmaceuticals are also discussed. Recent progress towards addressing these challenges is presented along with examples of incorporating α-particle therapy in pharmaceutical platforms that can be easily converted into diagnostic counterparts.


Assuntos
Neoplasias , Compostos Radiofarmacêuticos , Compostos Radiofarmacêuticos/uso terapêutico , Partículas alfa/uso terapêutico , Radioisótopos/uso terapêutico , Preparações Farmacêuticas , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia
4.
Med Phys ; 39(9): 5457-68, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957613

RESUMO

PURPOSE: To determine the effect of different bleaching wavelengths on the response of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. METHODS: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, and 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. RESULTS: The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 ± 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 ± 0.002)% and (0.035 ± 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 ± 0.14) min to (1.77 ± 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. CONCLUSIONS: The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.


Assuntos
Óxido de Alumínio , Carbono , Medições Luminescentes/métodos , Fenômenos Ópticos , Fótons , Humanos , Luz , Doses de Radiação
5.
Med Phys ; 39(2): 891-900, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22320798

RESUMO

PURPOSE: Planar integral spot dose (PISD) of proton pencil beam spots (PPBSs) is a required input parameter for beam modeling in some treatment planning systems used in proton therapy clinics. The measurement of PISD by using commercially available large area ionization chambers, like the PTW Bragg peak chamber (BPC), can have large uncertainties due to the size limitation of these chambers. This paper reports the results of our study of a novel method to determine PISD values from the measured lateral dose profiles and peak dose of the PPBS. METHODS: The PISDs of 72.5, 89.6, 146.9, 181.1, and 221.8 MeV energy PPBSs were determined by area integration of their planar dose distributions at different depths in water. The lateral relative dose profiles of the PPBSs at selected depths were measured by using small volume ion chambers and were investigated for their angular anisotropies using Kodak XV films. The peak spot dose along the beam's central axis (D(0)) was determined by placing a small volume ion chamber at the center of a broad field created by the superposition of spots at different locations. This method allows eliminating positioning uncertainties and the detector size effect that could occur when measuring it in single PPBS. The PISD was then calculated by integrating the measured lateral relative dose profiles for two different upper limits of integration and then multiplying it with corresponding D(0). The first limit of integration was set to radius of the BPC, namely 4.08 cm, giving PISD(RBPC). The second limit was set to a value of the radial distance where the profile dose falls below 0.1% of the peak giving the PISD(full). The calculated values of PISD(RBPC) obtained from area integration method were compared with the BPC measured values. Long tail dose correction factors (LTDCFs) were determined from the ratio of PISD(full)∕PISD(RBPC) at different depths for PPBSs of different energies. RESULTS: The spot profiles were found to have angular anisotropy. This anisotropy in PPBS dose distribution could be accounted in a reasonable approximate manner by taking the average of PISD values obtained using the in-line and cross-line profiles. The PISD(RBPC) values fall within 3.5% of those measured by BPC. Due to inherent dosimetry challenges associated with PPBS dosimetry, which can lead to large experimental uncertainties, such an agreement is considered to be satisfactory for validation purposes. The PISD(full) values show differences ranging from 1 to 11% from BPC measured values, which are mainly due to the size limitation of the BPC to account for the dose in the long tail regions of the spots extending beyond its 4.08 cm radius. The dose in long tail regions occur both for high energy beams such as 221.8 MeV PPBS due to the contributions of nuclear interactions products in the medium, and for low energy PPBS because of their larger spot sizes. The calculated LTDCF values agree within 1% with those determined by the Monte Carlo (MC) simulations. CONCLUSIONS: The area integration method to compute the PISD from PPBS lateral dose profiles is found to be useful both to determine the correction factors for the values measured by the BPC and to validate the results from MC simulations.


Assuntos
Algoritmos , Prótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Med Phys ; 49(9): 6098-6109, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35754208

RESUMO

PURPOSE: We assessed whether adding sodium borocaptate (BSH) or 4-borono-l-phenylalanine (BPA) to cells irradiated with proton beams influenced the biological effectiveness of those beams against prostate cancer cells to investigate if the alpha particles generated through proton-boron nuclear reactions would be sufficient to enhance the biological effectiveness of the proton beams. METHODS: We measured clonogenic survival in DU145 cells treated with 80.4-ppm BSH or 86.9-ppm BPA, or their respective vehicles, after irradiation with 6-MV X-rays, 1.2-keV/µm (low linear energy transfer [LET]) protons, or 9.9-keV/µm (high-LET) protons. We also measured γH2AX and 53BP1 foci in treated cells at 1 and 24 h after irradiation with the same conditions. RESULTS: We found that BSH radiosensitized DU145 cells across all radiation types. However, no difference was found in relative radiosensitization, characterized by the sensitization enhancement ratio or the relative biological effectiveness, for vehicle- versus BSH-treated cells. No differences were found in numbers of γH2AX or 53BP1 foci or γH2AX/53BP1 colocalized foci for vehicle- versus BSH-treated cells across radiation types. BPA did not radiosensitize DU145 cells nor induced any significant differences when comparing vehicle- versus BPA-treated cells for clonogenic cell survival or γH2AX and 53BP1 foci or γH2AX/53BP1 colocalized foci. CONCLUSIONS: Treatment with 11 B, at concentrations of 80.4 ppm from BSH or 86.9 ppm from BPA, had no effect on the biological effectiveness of proton beams in DU145 prostate cancer cells. Our results agree with published theoretical calculations indicating that the contribution of alpha particles from such reactions to the total absorbed dose and biological effectiveness is negligible. We also found that BSH radiosensitized DU145 cells to X-rays, low-LET protons, and high-LET protons but that the radiosensitization was not related to DNA damage.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias da Próstata , Terapia com Prótons , Compostos de Boro/farmacologia , Compostos de Boro/uso terapêutico , Humanos , Masculino , Fenilalanina/farmacologia , Fenilalanina/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Prótons , Eficiência Biológica Relativa
7.
Med Phys ; 49(9): 6221-6236, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35831779

RESUMO

BACKGROUND: Proton relative biological effectiveness (RBE) is known to depend on physical factors of the proton beam, such as its linear energy transfer (LET), as well as on cell-line specific biological factors, such as their ability to repair DNA damage. However, in a clinical setting, proton RBE is still considered to have a fixed value of 1.1 despite the existence of several empirical models that can predict proton RBE based on how a cell's survival curve (linear-quadratic model [LQM]) parameters α and ß vary with the LET of the proton beam. Part of the hesitation to incorporate variable RBE models in the clinic is due to the great noise in the biological datasets on which these models are trained, often making it unclear which model, if any, provides sufficiently accurate RBE predictions to warrant a departure from RBE = 1.1. PURPOSE: Here, we introduce a novel model of proton RBE based on how a cell's intrinsic radiosensitivity varies with LET, rather than its LQM parameters. METHODS AND MATERIALS: We performed clonogenic cell survival assays for eight cell lines exposed to 6 MV x-rays and 1.2, 2.6, or 9.9 keV/µm protons, and combined our measurements with published survival data (n = 397 total cell line/LET combinations). We characterized how radiosensitivity metrics of the form DSF% , (the dose required to achieve survival fraction [SF], e.g., D10% ) varied with proton LET, and calculated the Bayesian information criteria associated with different LET-dependent functions to determine which functions best described the underlying trends. This allowed us to construct a six-parameter model that predicts cells' proton survival curves based on the LET dependence of their radiosensitivity, rather than the LET dependence of the LQM parameters themselves. We compared the accuracy of our model to previously established empirical proton RBE models, and implemented our model within a clinical treatment plan evaluation workflow to demonstrate its feasibility in a clinical setting. RESULTS: Our analyses of the trends in the data show that DSF% is linearly correlated between x-rays and protons, regardless of the choice of the survival level (e.g., D10% , D37% , or D50% are similarly correlated), and that the slope and intercept of these correlations vary with proton LET. The model we constructed based on these trends predicts proton RBE within 15%-30% at the 68.3% confidence level and offers a more accurate general description of the experimental data than previously published empirical models. In the context of a clinical treatment plan, our model generally predicted higher RBE-weighted doses than the other empirical models, with RBE-weighted doses in the distal portion of the field being up to 50.7% higher than the planned RBE-weighted doses (RBE = 1.1) to the tumor. CONCLUSIONS: We established a new empirical proton RBE model that is more accurate than previous empirical models, and that predicts much higher RBE values in the distal edge of clinical proton beams.


Assuntos
Terapia com Prótons , Prótons , Teorema de Bayes , Terapia com Prótons/métodos , Tolerância a Radiação , Eficiência Biológica Relativa , Raios X
8.
Radiat Res ; 198(4): 336-346, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939823

RESUMO

Small molecule inhibitors are currently in preclinical and clinical development for the treatment of selected cancers, particularly those with existing genetic alterations in DNA repair and DNA damage response (DDR) pathways. Keen interest has also been expressed in combining such agents with other targeted antitumor strategies such as radiotherapy. Radiotherapy exerts its cytotoxic effects primarily through DNA damage-induced cell death; therefore, inhibiting DNA repair and the DDR should lead to additive and/or synergistic radiosensitizing effects. In this study we screened the response to X-ray or proton radiation in cell lines treated with DDR inhibitors (DDRis) targeting ATM, ATR, DNA-PKcs, Rad51, and PARP, with survival metrics established using clonogenic assays. We observed that DDRis generate significant radiosensitization in cancer and primary cells derived from normal tissue. Existing genetic defects in cancer cells appear to be an important consideration when determining the optimal inhibitor to use for synergistic combination with radiation. We also show that while greater radiosensitization can be achieved with protons (9.9 keV/µm) combined with DDRis, the relative biological effectiveness is unchanged or in some cases reduced. Our results indicate that while targeting the DDR can significantly radiosensitize cancer cells to such combinations, normal cells may also be equally or more severely affected, depending on the DDRi used. These data highlight the importance of identifying genetic defects as predictive biomarkers of response for combination treatment.


Assuntos
Neoplasias , Radiossensibilizantes , Proteínas Mutadas de Ataxia Telangiectasia/metabolismo , DNA , Dano ao DNA , Reparo do DNA , Humanos , Neoplasias/tratamento farmacológico , Inibidores de Poli(ADP-Ribose) Polimerases/farmacologia , Inibidores de Poli(ADP-Ribose) Polimerases/uso terapêutico , Prótons , Rad51 Recombinase/metabolismo , Radiossensibilizantes/farmacologia , Raios X
9.
Int J Radiat Oncol Biol Phys ; 112(2): 426-436, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610390

RESUMO

PURPOSE: BRCA1/2 pathogenic variant (PV) mutations confer radiation sensitivity preclinically, but there are limited data regarding breast cancer outcomes after radiation therapy (RT) among patients with documented BRCA1/2 PV mutations versus no PV mutations. METHODS AND MATERIALS: This retrospective cohort study included women with clinical stage I-III breast cancer who received definitive surgery and RT and underwent BRCA1/2 genetic evaluation at the The University of Texas MD Anderson Cancer Center. Rates of locoregional recurrence (LRR), disease-specific death (DSD), toxicities, and second cancers were compared by BRCA1/2 PV status. RESULTS: Of the 2213 women who underwent BRCA1/2 testing, 63% self-reported their race as White, 13.6% as Black/African American, 17.6% as Hispanic, and 5.8% as Asian/American Indian/Alaska Native; 124 had BRCA1 and 100 had BRCA2 mutations; and 1394 (63%) received regional nodal RT. The median follow-up time for all patients was 7.4 years (95% confidence interval [CI], 7.1-7.7 years). No differences were found between the groups with and without BRCA1/2 PV mutations in 10-year cumulative incidences of LRR (with mutations: 11.6% [95% CI, 7.0%-17.6%]; without mutations: 6.6% [95% CI, 5.3%-8.0%]; P = .466) and DSD (with mutations: 12.3% [95% CI, 8.0%-17.7%]; without mutations: 13.8% [95% CI, 12.0%-15.8%]; P = .716). On multivariable analysis, BRCA1/2 status was not associated with LRR or DSD, but Black/African American patients (P = .036) and Asians/American Indians/Alaska Native patients (P = .002) were at higher risk of LRR compared with White patients, and Black/African American patients were at higher risk of DSD versus White patients (P = .004). No in-field, nonbreast second cancers were observed in the BRCA1/2 PV group. Rates of acute and late grade ≥3 radiation-related toxicity in the BCRA1/2 PV group were 5.4% (n = 12) and 0.4% (n = 1), respectively. CONCLUSIONS: Oncologic outcomes in a diverse cohort of patients with breast cancer who had a germline BRCA1/2 PV mutation and were treated with RT were similar to those of patients with no mutation, supporting the use of RT according to standard indications in patients with a germline BRCA1/2 PV mutation.


Assuntos
Neoplasias da Mama , Recidiva Local de Neoplasia , Proteína BRCA1/genética , Neoplasias da Mama/genética , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Feminino , Células Germinativas/patologia , Mutação em Linhagem Germinativa , Humanos , Mutação , Recidiva Local de Neoplasia/genética , Estudos Retrospectivos
10.
Int J Radiat Oncol Biol Phys ; 112(2): 437-444, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34582940

RESUMO

PURPOSE: Multigene panel testing has increased the detection of germline mutations in patients with breast cancer. The implications of using radiation therapy (RT) to treat patients with pathogenic variant (PV) mutations are not well understood and have been studied mostly in women with only BRCA1 or BRCA2 PVs. We analyzed oncologic outcomes and toxicity after adjuvant RT in a contemporary, diverse cohort of patients with breast cancer who underwent genetic panel testing. METHODS AND MATERIALS: We retrospectively reviewed the records of 286 women with clinical stage I-III breast cancer diagnosed from 1995 to 2017 who underwent surgery, breast or chest wall RT with or without regional nodal irradiation, multigene panel testing, and evaluation at a large cancer center's genetic screening program. We evaluated rates of overall survival, locoregional recurrence, disease-specific death, and radiation-related toxicities in 3 groups: BRCA1/2 PV carriers, non-BRCA1/2 PV carriers, and patients without PV mutations. RESULTS: PVs were detected in 25.2% of the cohort (12.6% BRCA1/2 and 12.6% non-BRCA1/2). The most commonly detected non-BRCA1/2 mutated genes were ATM, CHEK2, PALB2, CDH1, TP53, and PTEN. The median follow-up time for the entire cohort was 4.4 years (95% confidence interval, 3.8-4.9 years). No differences were found in overall survival, locoregional recurrence, or disease-specific death between groups (P > .1 for all). Acute and late toxicities were comparable across groups. CONCLUSION: Oncologic and toxicity outcomes after RT in women with PV germline mutations detected by multigene pane testing are similar to those in patients without detectable mutations, supporting the use of adjuvant RT as a standard of care when indicated.


Assuntos
Neoplasias da Mama , Mutação em Linhagem Germinativa , Proteína BRCA1/genética , Neoplasias da Mama/genética , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Genes BRCA2 , Predisposição Genética para Doença , Mutação em Linhagem Germinativa/genética , Humanos , Recidiva Local de Neoplasia/genética , Estudos Retrospectivos , Resultado do Tratamento
11.
Med Phys ; 48(6): 3243-3261, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33837540

RESUMO

PURPOSE: To show that intrinsic radiosensitivity varies greatly for protons and carbon (C) ions in addition to photons, and that DNA repair capacity remains important in governing this variability. METHODS: We measured or obtained from the literature clonogenic survival data for a number of human cancer cell lines exposed to photons, protons (9.9 keV/µm), and C-ions (13.3-77.1 keV/µm). We characterized their intrinsic radiosensitivity by the dose for 10% or 50% survival (D10% or D50% ), and quantified the variability at each radiation quality by the coefficient of variation (COV) in D10% and D50% . We also treated cells with DNA repair inhibitors prior to irradiation to assess how DNA repair capacity affects their variability. RESULTS: We found no statistically significant differences in the COVs of D10% or D50% between any of the radiation qualities investigated. The same was true regardless of whether the cells were treated with DNA repair inhibitors, or whether they were stratified into histologic subsets. Even within histologic subsets, we found remarkable differences in radiosensitivity for high LET C-ions that were often greater than the variations in RBE, with brain cancer cells varying in D10% (D50% ) up to 100% (131%) for 77.1 keV/µm C-ions, and non-small cell lung cancer and pancreatic cancer cell lines varying up to 55% (76%) and 51% (78%), respectively, for 60.5 keV/µm C-ions. The cell lines with modulated DNA repair capacity had greater variability in intrinsic radiosensitivity across all radiation qualities. CONCLUSIONS: Even for cell lines of the same histologic type, there are remarkable variations in intrinsic radiosensitivity, and these variations do not differ significantly between photon, proton or C-ion radiation. The importance of DNA repair capacity in governing the variability in intrinsic radiosensitivity is not significantly diminished for higher LET radiation.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carbono , Linhagem Celular , Sobrevivência Celular , Humanos , Prótons , Tolerância a Radiação , Eficiência Biológica Relativa
12.
Int J Radiat Oncol Biol Phys ; 111(5): 1298-1309, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34400267

RESUMO

PURPOSE: To estimate the effects of interfractional anatomic changes on dose to organs at risk (OARs) and tumors, as measured with cone beam computed tomography (CBCT) image guidance for pancreatic stereotactic body radiation therapy. METHODS AND MATERIALS: We evaluated 11 patients with pancreatic cancer whom were treated with stereotactic body radiation therapy (33-40 Gy in 5 fractions) using daily CT-on-rails (CTOR) image guidance immediately before treatment with breath-hold motion management. CBCT alignment was simulated in the treatment planning software by aligning the original planning CT to each fractional CTOR image set via fiducial markers. CTOR data sets were used to calculate fractional doses after alignment by applying the rigid shift of the planning CT and CTOR image sets to the planning treatment isocenter and recalculating the fractional dose. Accumulated dose to the gross tumor volume (GTV), tumor vessel interface, duodenum, small bowel, and stomach were calculated by summing the 5 fractional absolute dose-volume histograms into a single dose-volume histogram for comparison with the original planned dose. RESULTS: Four patients had a GTV D100% of at least 1.5 Gy less than the fractional planned value in several fractions; 4 patients had fractional underestimation of duodenum dose by 1.0 Gy per fraction. The D1.0 cm3 <35 Gy constraint was violated for at least 1 OAR in 3 patients, with either the duodenum (n = 2) or small bowel (n = 1) D1.0 cm3 being higher on the accumulated dose distribution (P = .01). D100% was significantly lower according to accumulated dose GTV (P = .01) and tumor vessel interface (P = .02), with 4 and 2 patients having accumulated D100%  ≥4 Gy lower than the planned value for the GTV and tumor vessel interface, respectively. CONCLUSIONS: For some patients, CBCT image guidance based on fiducial alignment may cause large dosimetric uncertainties for OARs and target structures, according to accumulated dose.


Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Pâncreas , Radiometria , Dosagem Radioterapêutica
13.
Phys Med Biol ; 66(5)2021 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-33227715

RESUMO

The treatment of cancer with proton radiation therapy was first suggested in 1946 followed by the first treatments in the 1950s. As of 2020, almost 200 000 patients have been treated with proton beams worldwide and the number of operating proton therapy (PT) facilities will soon reach one hundred. PT has long moved from research institutions into hospital-based facilities that are increasingly being utilized with workflows similar to conventional radiation therapy. While PT has become mainstream and has established itself as a treatment option for many cancers, it is still an area of active research for various reasons: the advanced dose shaping capabilities of PT cause susceptibility to uncertainties, the high degrees of freedom in dose delivery offer room for further improvements, the limited experience and understanding of optimizing pencil beam scanning, and the biological effect difference compared to photon radiation. In addition to these challenges and opportunities currently being investigated, there is an economic aspect because PT treatments are, on average, still more expensive compared to conventional photon based treatment options. This roadmap highlights the current state and future direction in PT categorized into four different themes, 'improving efficiency', 'improving planning and delivery', 'improving imaging', and 'improving patient selection'.


Assuntos
Neoplasias , Terapia com Prótons , Biologia , Humanos , Neoplasias/radioterapia , Fótons , Física , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
14.
Med Phys ; 37(9): 4960-70, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20964215

RESUMO

PURPOSE: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. METHODS: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. RESULTS: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. CONCLUSIONS: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.


Assuntos
Método de Monte Carlo , Terapia com Prótons , Radioterapia/métodos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
15.
Med Phys ; 47(1): 272-281, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31677156

RESUMO

PURPOSE: High energetic carbon (C-) ion beams undergo nuclear interactions with tissue, producing secondary nuclear fragments. Thus, at depth, C-ion beams are composed of a mixture of different particles with different linear energy transfer (LET) values. We developed a technique to enable isolation of DNA damage response (DDR) in mixed radiation fields using beam line microscopy coupled with fluorescence nuclear track detectors (FNTDs). METHODS: We imaged live cells on a coverslip made of FNTDs right after C-ion, proton or photon irradiation using an in-house built confocal microscope placed in the beam path. We used the FNTD to link track traversals with DNA damage and separated DNA damage induced by primary particles from fragments. RESULTS: We were able to spatially link physical parameters of radiation tracks to DDR in live cells to investigate spatiotemporal DDR in multi-ion radiation fields in real time, which was previously not possible. We demonstrated that the response of lesions produced by the high-LET primary particles associates most strongly with cell death in a multi-LET radiation field, and that this association is not seen when analyzing radiation induced foci in aggregate without primary/fragment classification. CONCLUSIONS: We report a new method that uses confocal microscopy in combination with FNTDs to provide submicrometer spatial-resolution measurements of radiation tracks in live cells. Our method facilitates expansion of the radiation-induced DDR research because it can be used in any particle beam line including particle therapy beam lines. CATEGORY: Biological Physics and Response Prediction.


Assuntos
Carbono , Dano ao DNA , Corantes Fluorescentes/metabolismo , Transferência Linear de Energia , Linhagem Celular Tumoral , Sobrevivência Celular , Humanos , Imagem Molecular , Fatores de Tempo
16.
Radiat Prot Dosimetry ; 183(1-2): 264-269, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30726978

RESUMO

Human exposure to α-particles from radon and other radionuclides is associated with carcinogenesis, but if well controlled and targeted to cancer cells, α-particles may be used in radiotherapy. Thus, it is important to understand the biological effects of α-particles to predict cancer risk and optimise radiotherapy. To enable studies of α-particles in cells, we developed and characterised an α-particle automated irradiation rig that allows exposures at a shallow angle (70° to the normal) of cell monolayers in a 30 mm diameter dish to complement standard perpendicular irradiations. The measured incident energy of the α-particles was 3.3 ± 0.5 MeV (LET in water = 120 keV µm-1), with a maximum incident dose rate of 1.28 ± 0.02 Gy min-1, which for a 5 µm cell monolayer corresponds to a mean dose rate of 1.57 ± 0.02 Gy min-1 and a mean LET in water of 154 keV µm-1. The feasibility of resolving radiation-induced DNA double-strand breaks (DSB) foci along the track of α-particles was demonstrated using immunofluorescent labelling with γH2AX and 53BP1 in normal MRC-5 human lung cells.


Assuntos
Partículas alfa , Células Cultivadas/efeitos da radiação , Pulmão/citologia , Radiobiologia/instrumentação , Quebras de DNA de Cadeia Dupla , Desenho de Equipamento , Humanos , Transferência Linear de Energia
17.
Int J Radiat Oncol Biol Phys ; 105(5): 1119-1125, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31425731

RESUMO

PURPOSE: This study seeks to identify biological factors that may yield a therapeutic advantage of proton therapy versus photon therapy. Specifically, we address the role of nonhomologous end-joining (NHEJ) and homologous recombination (HR) in the survival of cells in response to clinical photon and proton beams. METHODS AND MATERIALS: We irradiated HT1080, M059K (DNA-PKcs+/+), and HCC1937 human cancer cell lines and their isogenic counterparts HT1080-shDNA-PKcs, HT1080-shRAD51IND, M059J (DNA-PKcs-/-), and HCC1937-BRCA1 (BRCA1 complemented) to assess cell clonogenic survival and γ-H2AX radiation-induced foci. Cells were irradiated with either clinically relevant photons or 1 of 3 proton linear energy transfer (LET) values. RESULTS: Our results indicate that NHEJ deficiency is more important in dictating cell survival than proton LET. Cells with disrupted HR through BRCA1 mutation showed increased radiosensitivity only for high-LET protons whereas RAD51 depletion showed increased radiosensitivity for both photons and protons. DNA double strand breaks, assessed by γ-H2AX radiation-induced foci, showed greater numbers after 24 hours in cells exposed to higher LET protons. We also observed that NHEJ-deficient cells were unable to repair the vast majority of double strand breaks after 24 hours. CONCLUSIONS: BRCA1 mutation significantly sensitizes cells to protons, but not photons. Loss of NHEJ renders cells hypersensitive to radiation, whereas the relative importance of HR increases with LET across several cell lines. This may be attributable to the more clustered damage induced by higher LET protons, which are harder to repair through NHEJ. This highlights the importance of tumor biology in dictating treatment modality and suggests BRCA1 as a potential biomarker for proton therapy response. Our data also support the use of pharmacologic inhibitors of DNA repair to enhance the sensitivity to different radiation types, although this raises issues for normal tissue toxicity.


Assuntos
Morte Celular/genética , Reparo do DNA por Junção de Extremidades/fisiologia , Genes BRCA1 , Recombinação Homóloga/fisiologia , Transferência Linear de Energia , Fótons , Prótons , Proteínas de Ligação ao Cálcio/genética , Linhagem Celular Tumoral , Sobrevivência Celular/genética , Sobrevivência Celular/efeitos da radiação , Quebras de DNA de Cadeia Dupla , Inativação Gênica , Histonas/análise , Humanos , Mutação , Rad51 Recombinase/genética , Tolerância a Radiação/genética , Tolerância a Radiação/efeitos da radiação , Fatores de Tempo
18.
Int J Radiat Oncol Biol Phys ; 105(4): 698-712, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31381960

RESUMO

The advent of affordable and rapid next-generation DNA sequencing technology, along with the US Supreme Court ruling invalidating gene patents, has led to a deluge of germline and tumor genetic variant tests that are being rapidly incorporated into clinical cancer decision-making. A major concern for clinicians is whether the presence of germline mutations may increase the risk of radiation toxicity or secondary malignancies. Because scarce clinical data exist to inform decisions at this time, the American Society for Radiation Oncology convened a group of radiation science experts and clinicians to summarize potential issues, review relevant data, and provide guidance for adult patients and their care teams regarding the impact, if any, that genetic testing should have on radiation therapy recommendations. During the American Society for Radiation Oncology workshop, several main points emerged, which are discussed in this manuscript: (1) variants of uncertain significance should be considered nondeleterious until functional genomic data emerge to demonstrate otherwise; (2) possession of germline alterations in a single copy of a gene critical for radiation damage responses does not necessarily equate to increased risk of radiation-induced toxicity; (3) deleterious ataxia-telangiesctasia gene mutations may modestly increase second cancer risk after radiation therapy, and thus follow-up for these patients after indicated radiation therapy should include second cancer screening; (4) conveying to patients the difference between relative and absolute risk is critical to decision-making; and (5) more work is needed to assess the impact of tumor somatic alterations on the probability of response to radiation therapy and the potential for individualization of radiation doses. Data on radiosensitivity related to specific genetic mutations is also briefly discussed.


Assuntos
Testes Genéticos , Mutação , Neoplasias/genética , Neoplasias/radioterapia , Radio-Oncologistas , Tolerância a Radiação/genética , Adulto , Ataxia Telangiectasia/genética , Proteínas Mutadas de Ataxia Telangiectasia/genética , Tomada de Decisão Clínica , Consenso , Reparo do DNA/genética , Genes BRCA1 , Genes BRCA2 , Variação Genética , Mutação em Linhagem Germinativa , Pesquisas sobre Atenção à Saúde , Heterozigoto , Humanos , Neoplasias Induzidas por Radiação/genética , Segunda Neoplasia Primária/genética , Síndrome , Terminologia como Assunto
19.
Cancer Res ; 79(9): 2327-2338, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31043430

RESUMO

When pancreatic cancer cannot be removed surgically, patients frequently experience morbidity and death from progression of their primary tumor. Radiation therapy (RT) cannot yet substitute for an operation because radiation causes fatal bleeding and ulceration of the nearby stomach and intestines before achieving tumor control. There are no FDA-approved medications that prevent or reduce radiation-induced gastrointestinal injury. Here, we overcome this fundamental problem of anatomy and biology with the use of the oral EGLN inhibitor FG-4592, which selectively protects the intestinal tract from radiation toxicity without protecting tumors. A total of 70 KPC mice with autochthonous pancreatic tumors received oral FG-4592 or vehicle control ± ablative RT to a cumulative 75 Gy administered in 15 daily fractions to a limited tumor field. Although ablative RT reduced complications from local tumor progression, fatal gastrointestinal bleeding was observed in 56% of mice that received high-dose RT with vehicle control. However, radiation-induced bleeding was completely ameliorated in mice that received high-dose RT with FG-4592 (0% bleeding, P < 0.0001 compared with vehicle). Furthermore, FG-4592 reduced epithelial apoptosis by half (P = 0.002) and increased intestinal microvessel density by 80% compared with vehicle controls. EGLN inhibition did not stimulate cancer growth, as treatment with FG-4592 alone, or overexpression of HIF2 within KPC tumors independently improved survival. Thus, we provide a proof of concept for the selective protection of the intestinal tract by the EGLN inhibition to enable ablative doses of cytotoxic therapy in unresectable pancreatic cancer by reducing untoward morbidity and death from radiation-induced gastrointestinal bleeding. SIGNIFICANCE: Selective protection of the intestinal tract by EGLN inhibition enables potentially definitive doses of radiation therapy. This might allow radiation to be a surgical surrogate for unresectable pancreatic cancer.Graphical Abstract: http://cancerres.aacrjournals.org/content/canres/79/9/2327/F1.large.jpg.


Assuntos
Glicina/análogos & derivados , Prolina Dioxigenases do Fator Induzível por Hipóxia/antagonistas & inibidores , Isoquinolinas/farmacologia , Neoplasias Pancreáticas/mortalidade , Lesões por Radiação/prevenção & controle , Protetores contra Radiação/farmacologia , Radioterapia/mortalidade , Animais , Apoptose , Feminino , Glicina/farmacologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/radioterapia , Proteínas Proto-Oncogênicas p21(ras)/fisiologia , Lesões por Radiação/etiologia , Lesões por Radiação/mortalidade , Radioterapia/efeitos adversos , Fatores de Transcrição/fisiologia , Proteína Supressora de Tumor p53/fisiologia
20.
Phys Med Biol ; 53(17): 4605-19, 2008 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-18678928

RESUMO

Density heterogeneities in the path of proton beams are known to cause degradation of the Bragg peak and, thus, widening of its distal fall-off. Inadequate accounting for this effect may lead to unwanted dose delivered to normal tissue distal to the target volume. In low-density regions, such as the thorax, this may lead to large volumes of healthy tissue receiving unnecessary dose. Although it is known that multiple Coulomb scattering within the density heterogeneities is the main cause of Bragg peak degradation, no systematic attempt has been made to quantify the contribution of multiple Coulomb scattering and nuclear scattering. Through a systematic study using a 220 MeV proton beam, we show that nuclear scattering contributes to about 5% of the distal fall-off width and is only slightly dependent on heterogeneity complexity. Furthermore, we also show that the energy spectra of the proton fluence downstream of various heterogeneity volumes are well correlated with the Bragg peak distal fall-off widths. Based on this correlation, a novel method for predicting distal fall-offs is suggested. This method is tested for three clinical setups of a voxelized model of a human head based on computer tomography data. Results are within 3% of the distal fall-off values obtained using Monte Carlo simulations.


Assuntos
Aceleradores de Partículas , Radioterapia de Alta Energia/métodos , Elétrons , Cabeça/patologia , Humanos , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA