1.
Int J Radiat Oncol Biol Phys ; 42(2): 437-54, 1998 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-9788427

RESUMO

PURPOSE: The development of the first prototype active matrix flat-panel imager (AMFPI) capable of radiographic and fluoroscopic megavoltage operation is reported. The signal and noise performance of individual pixels is empirically quantified. Results of an observer-dependent study of imaging performance, using a contrast-detail phantom, are detailed and radiographic patient images are shown. Finally, a theoretical investigation of the zero-frequency detective quantum efficiency (DQE) performance of such imagers, using a cascaded systems formalism, is presented. METHODS AND MATERIALS: The imager is based on a 508-microm pitch, 26 x 26 cm2 array which detects radiation indirectly via an overlying copper plate + phosphor screen converter. RESULTS: Due to its excellent optical coupling, the imager exhibits sensitivity superior to that of video-based systems. With an approximately 133 mg/cm2 Gd2O2S:Tb screen the system is x-ray quantum-noise-limited down to approximately 0.3 cGy, conservatively, and extensions of this behavior to even lower doses by means of reduced additive electronic noise is predicted. The observer-dependent study indicates performance superior to that of conventional radiotherapy film while the patient images demonstrate good image quality at 1 to 4 MU. The theoretical studies suggest that, with a 133 mg/cm2 Gd2O2S:Tb screen, the system would provide DQE performance equivalent to that of video-based systems and that almost a factor of two improvement in DQE is achievable through the incorporation of a 400 mg/cm2 screen. CONCLUSION: The reported prototype imager is the first megavoltage AMFPI having performance characteristics consistent with practical clinical operation. The superior contrast-detail sensitivity of the imager allows the capture of high-quality 6- and 15-MV images at minimal dose. Moreover, significant performance improvements, including extension of the operational range up to full portal doses, appear feasible. Such capabilities could be of considerable practical benefit in patient localization and verification.


Assuntos
Radiografia/métodos , Ecrans Intensificadores para Raios X , Idoso , Humanos , Masculino , Variações Dependentes do Observador , Imagens de Fantasmas , Tecnologia Radiológica
2.
Med Phys ; 24(1): 51-70, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9029541

RESUMO

Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536 x 1920 pixels with a pixel-to-pixel pitch of 127 microns. Each pixel consists of a discrete amorphous silicon n-i-p photodiode coupled to an amorphous silicon thin-film transistor. The imager detects incident x rays indirectly by means of an intensifying screen placed over the array. External acquisition electronics send control signals to the array and process analog imaging signals from the pixels. Considerations for operation of the imager in both fluoroscopic and radiographic modes are detailed and empirical signal performance data are presented with an emphasis on exploring similarities and differences between the two modes. Measurements which characterize the performance of the imager were performed as a function of operational parameters in the absence or presence of illumination from a light-emitting diode or x rays. These measurements include characterization of the drift and magnitude of the pixel dark signal, the size of the pixel switching transient, the temporal behavior of pixel sampling and the implied maximum frame rate, the dependence of relative pixel efficiency and pixel response on photodiode reverse bias voltage and operational mode, the degree of linearity of pixel response, and the trapping and release of charge from metastable states in the photodiodes. In addition, X-ray sensitivity as a function of energy for a variety of phosphor screens for both fluoroscopic and radiographic operation is reported. Example images of a line-pair pattern and an anthropomorphic phantom in each mode are presented along with a radiographic image of a human hand. General and specific improvements in imager design are described and anticipated developments are discussed. This represents the first systematic investigation of the operation and properties in both radiographic and fluoroscopic modes of an imager incorporating such an array.


Assuntos
Fluoroscopia/instrumentação , Mãos/diagnóstico por imagem , Imagens de Fantasmas , Radiografia/instrumentação , Osso e Ossos/diagnóstico por imagem , Eletrônica , Desenho de Equipamento , Fluoroscopia/métodos , Humanos , Radiografia/métodos , Sensibilidade e Especificidade , Filme para Raios X , Raios X
3.
J Spinal Cord Med ; 18(2): 98-102, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7640980

RESUMO

Bladder responses to percutaneous electrodes were investigated with stimulation in three male spinal cats. The animals had been spinalized (T1 level lesion) 10 weeks prior to these studies and had been instrumented with chronic bladder had been spinalized (T1 level lesion) 10 weeks prior to these studies and had been instrumented with chronic bladder wall electrodes and suprapubic bladder catheters for filling and pressure recording. percutaneous stimulation in tethered animals was conducted wit hook electrodes inserted with a needle in the abdomen bilaterally adjacent to the bladder trigone. Stimulation was conducted with 40 Hz pulse trains of 10 to 30 mA for three seconds. Stimulation with both percutaneous and chronic electrodes induced high bladder pressures and voiding. In addition, with chronically implanted electrodes, impedance monitoring of bladder volume was found to be an effective recording technique.


Assuntos
Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/terapia , Bexiga Urinária/fisiopatologia , Animais , Gatos , Impedância Elétrica , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Eletrofisiologia , Masculino , Monitorização Fisiológica , Estimulação Elétrica Nervosa Transcutânea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA