Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Musculoskelet Disord ; 17: 153, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27059990

RESUMO

BACKGROUND: The number of hip fractures and resulting post-surgical outcome are a major public health concern and the incidence is expected to increase significantly. The acute recovery phase after hip fracture surgery in elder patients is often complicated by severe pain, high morphine consumption, perioperative blood loss with subsequent transfusion and delirium. Postoperative continuous-flow cryocompression therapy is suggested to minimize these complications and to attenuate the inflammatory reaction that the traumatic fracture and subsequent surgical trauma encompass. Based on a pilot study in patients undergoing total hip arthroplasty for osteoarthritis, it is anticipated that patients treated with continuous-flow cryocompression therapy will have less pain, less morphine consumption and lower decrease of postoperative hemoglobin levels. These factors are associated with a shorter hospital stay and better long-term (functional) outcome. METHODS/DESIGN: One hundred and sixty patients with an intra or extracapsular hip fracture scheduled for internal fixation (intramedullary hip nail, dynamic hip screw or cannulated screws) or prosthesis surgery (total hip or hemiarthroplasty) will be included in this prospective, open-label, parallel, multicenter, randomized controlled, clinical superiority trial. Patients will be allocated to two treatment arms: group 'A' will be treated with continuous-flow cryocompression therapy and compared to group 'B' that will receive standard care. Routine use of drains and/or compressive bandages is allowed in both groups. The primary objective of this study is to compare acute pain the first 72 h postoperative, measured with numeric rating scale for pain. Secondary objectives are: (non-) morphine analgesic use; adjusted postoperative hemoglobin level; transfusion incidence; incidence, duration and severity of delirium and use of psychotropic medication; length of stay; location and duration of rehabilitation; functional outcome; short-term patient-reported health outcome; general and cryotherapy related complications and feasibility. DISCUSSION: This is the first randomized controlled trial that will assess the analgesic efficiacy of continuous-flow cryocompression therapy in the acute recovery phase after hip fracture surgery. TRIAL REGISTRATION: www.trialregister.nl, NTR4152 (23(rd) of August 2013).


Assuntos
Artroplastia de Quadril/efeitos adversos , Crioterapia/métodos , Fraturas do Quadril/cirurgia , Dor Pós-Operatória/terapia , Idoso , Bandagens Compressivas , Feminino , Fraturas do Quadril/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Resultado do Tratamento
2.
BMC Musculoskelet Disord ; 15: 265, 2014 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-25098693

RESUMO

BACKGROUND: The 'Parsonage-Turner syndrome' (PTS) is a rare but distinct disorder with an abrupt onset of shoulder pain, followed by weakness and atrophy of the upper extremity musculature, and a slow recovery requiring months to years. To our best knowledge, this is the first case describing symptoms and signs of PTS following the administration of a post-exposure prophylaxis (PEP) regimen against possible human immunodeficiency virus (HIV) and hepatitis B virus (HBV) infection. CASE PRESENTATION: A 25-year-old Caucasian man presented with pain and unilateral scapular winging following PEP against possible HIV and HBV infection. Although atrophy and weakness were observed for the right supraspinatus muscle, a full range of motion was achievable. Neurological examination, plain radiography of the right shoulder and electromyography showed no additional abnormalities. The patient was diagnosed with post-vaccination PTS and treated non-operatively. During the following 15 months the scapular winging receded and full muscle strength was regained. CONCLUSION: Parsonage-Turner syndrome is a rare clinical diagnosis. The precise pathophysiological mechanism of PTS remains unclear, but it seems to involve an interaction between genetic predisposition, mechanical vulnerability and an autoimmune trigger. An immunological event, such as - in this case - a vaccination as part of PEP treatment, can trigger the onset of PTS. The clinical presentation is distinctive with acute severe pain followed by patchy paresis, atrophy and sensory symptoms that persist for months to years. No currently available tests can provide a definite confirmation or exclusion of PTS. Routine blood examination, electromyography (EMG), and computed tomography (CT) or magnetic resonance imaging (MRI) serve mainly to exclude other disorders. The recovery can be quite lengthy, non-operative treatment is the accepted practice. Supplementary administration of oral prednisolone could shorten the duration of pain. Although the outcome is typically preferable, a substantial amount of patients are left with some residual paresis and functional impairment.


Assuntos
Antivirais/efeitos adversos , Neurite do Plexo Braquial/induzido quimicamente , Coinfecção , Infecções por HIV/prevenção & controle , Vacinas contra Hepatite B/efeitos adversos , Hepatite B/prevenção & controle , Profilaxia Pós-Exposição , Ombro/fisiopatologia , Adulto , Fenômenos Biomecânicos , Neurite do Plexo Braquial/diagnóstico , Neurite do Plexo Braquial/fisiopatologia , Neurite do Plexo Braquial/terapia , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Hepatite B/diagnóstico , Hepatite B/imunologia , Humanos , Masculino , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento , Vacinação/efeitos adversos
3.
Injury ; 48(12): 2754-2761, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29079365

RESUMO

BACKGROUND: The acute recovery phase after hip fracture surgery is often complicated by severe pain, postoperative blood loss with subsequent transfusion, and delirium. Prevalent comorbidity in hip fracture patients limit the use of opioid-based analgesic therapies, yielding a high risk for inferior pain treatment. Postoperative cryotherapy is suggested to provide an analgesic effect, and to reduce postoperative blood loss. In this prospective, open-label, parallel, multicentre, randomized controlled, clinical trial, we aimed to determine the efficacy of continuous-flow cryocompression therapy (CFCT) in the acute recovery phase after hip fracture surgery. METHODS: Patients with an intra or extracapsular hip fracture scheduled for surgery were included. Subjects were allocated to receive postoperative CFCT or usual care. The primary endpoint was numeric rating scale (NRS) pain the first 72 postoperative hours. Secondly, analgesic use; postoperative haemoglobin change and transfusion incidence; functional outcome; length of stay; delirium incidence; location of rehabilitation; patient-reported health outcome; complications and feasibility were assessed. RESULTS: Sixty-one subjects in the control group, and 64 subjects in the CFCT group were analysed. Within the CFCT group, post treatment NRS pain declined 0.31 (p=0.07) at 24h, 0.28 (p=0.07) at 48h, and 0.47 (p=0.002) at 72h relative to pre treatment NRS pain. Sensitivity analysis at 72h showed that NRS pain was 0.92 lower in the CFCT group when compared to the control group (1.50 vs. 2.42; p=0.03). Postoperative analgesic use was comparable between groups. Between postoperative day one and three haemoglobin declined 0.29mmol/l in the CFCT group and 0.51mmol/l in controls (p=0.06), and transfusion incidence was comparable. The timed up and go test and length of stay were also comparable between both groups. Complications, amongst delirium and cryotherapy-related adverse events were not statistically significantly different. Discharge locations did not differ between groups. At outpatient follow-up subjects did not differ in patient-reported health outcome scores. Subjects rated CFCT satisfaction with an average of 7.1 out of 10 points. CONCLUSIONS: No evidence was recorded to suggest that CFCT has an added value in the acute recovery phase after hip fracture surgery. If patients complete the CFCT treatment schedule, a mild analgesic effect is observed at 72h.


Assuntos
Crioterapia/métodos , Delírio/terapia , Consolidação da Fratura/fisiologia , Fraturas do Quadril/cirurgia , Dor Pós-Operatória/terapia , Hemorragia Pós-Operatória/terapia , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/uso terapêutico , Bandagens Compressivas , Feminino , Seguimentos , Fraturas do Quadril/complicações , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Dor Pós-Operatória/fisiopatologia , Hemorragia Pós-Operatória/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento
4.
J Biomech ; 48(12): 3460-8, 2015 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-26105659

RESUMO

Measurement of 3D scapular kinematics is meaningful in patients with shoulder pathologies showing scapular dyskinesis. This study evaluates the effect of single and double anatomical calibration (0° and 120°) with a scapula locator compared to standard calibration (using sensor alignment with the spina scapulae and static upright posture, ISEO-protocol) on 3D scapular kinematics measured with an inertial and magnetic measurement system (IMMS). Ten patients with scapular dyskinesis performed humeral anteflexion and abduction movements while 3D scapular kinematics were measured using IMMS sensors. The sensor on the scapula was anatomically calibrated (i) according to the ISEO-protocol, (ii) using single scapula locator calibration (0°) and (iii) double scapula locator calibration (0° and 120°). For calibration, the scapula locator (with IMMS) was positioned on the scapula, while holding the humerus at several anteflexion and abduction postures. Single and double calibration resulted in a significant increase of scapular anterior tilt (14-30°) with respect to the skin-fixed sensor (ISEO). Protraction angles were not significantly different. During anteflexion, double calibration did not show a significant increase in lateral rotation compared to single calibration. During abduction of >90°, double calibration showed 10-14° increased lateral rotation with respect to single calibration, although this was not significant (P>0.06). Calibration with a scapula locator when applying IMMS is necessary, because measures of scapular anterior tilt are grossly underestimated with the ISEO-protocol. For shoulder movements that exceed 90° elevation, a double calibration prevents small but relevant underestimation of lateral rotation angles of the scapula.


Assuntos
Imãs , Fenômenos Mecânicos , Escápula/anatomia & histologia , Escápula/lesões , Luxação do Ombro/diagnóstico , Tecnologia sem Fio/instrumentação , Adulto , Braço/fisiopatologia , Fenômenos Biomecânicos , Calibragem , Feminino , Humanos , Úmero/fisiopatologia , Masculino , Pessoa de Meia-Idade , Movimento , Postura , Rotação , Ombro/fisiopatologia , Luxação do Ombro/fisiopatologia , Adulto Jovem
5.
Arch Trauma Res ; 3(4): e23083, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25685751

RESUMO

BACKGROUND: In cities with trams as public transportation, tram tracks are often on public roads, creating a shared road situation with other road participants like cyclists. Beside the risk of direct collisions, this situation can also lead to bicycle wheels getting wedged in tram tracks, causing cyclists to fall. OBJECTIVES: The aim of this study was to gain more insight in the injury pattern of this trauma mechanism and to draw attention to the risks of the infrastructural situation with on-road tram tracks. PATIENTS AND METHODS: A one-year, prospective, observational cohort study was conducted. All patients admitted after presentation to the emergency department of a level 1 trauma center, who got injured because their bicycle wheels got wedged in tram tracks, were included. Data were collected on patient demographics, type of injury and treatment. RESULTS: Ten patients were included. Six were male. The mean age was 38 years. Six patients required surgery, mostly because of extremity injuries. Mean duration of admission was 4 days. Mean injury severity score was 13. One patient died as a result of the injuries sustained in the accident. CONCLUSIONS: Tram tracks on public roads are potentially dangerous and can lead to serious injuries and even mortality amongst cyclist. Operative intervention is frequently needed.

6.
Med Biol Eng Comput ; 52(11): 921-931, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25192921

RESUMO

To direct interventions aimed at improving scapular position and motion in shoulder pathologies, a clinically feasible, objective, sensitive and reliable assessment of scapular dyskinesis is needed. The aim of this study is to evaluate the intra- and inter-observer reliability and the precision of 3D scapula kinematics measurement using wireless sensors of an inertial and magnetic measurement system (IMMS). Scapular kinematics during humerus anteflexion and abduction of 20 subjects without shoulder pathologies were measured twice by two observers at two different days, using IMMS. Similar movement patterns and corresponding high intraclass correlation coefficients were found within (intra) and between (inter) observers, especially for scapular retraction/protraction (0.65-0.85) and medio/lateral rotation (0.56-0.91). Lowest reliability and highest difference in range of motion were observed for anterior/posterior tilt. Medio/lateral rotation and anterior/posterior tilt showed a high precision, with standard error of measurement being mostly below 5°. The inter-observer measurements of retraction/protraction showed lowest precision, reflected in systematic differences. This is caused by an offset in anatomical calibration of the sensors. IMMS enables easy and objective measurement of 3D scapula kinematics. Further research in a patient population should focus on clinical feasibility and validity for measurement of scapular dyskinesis. This would include the application of a scapula locator to enhance anatomical calibration.


Assuntos
Fenômenos Biomecânicos/fisiologia , Amplitude de Movimento Articular/fisiologia , Escápula/fisiologia , Ombro/fisiologia , Telemedicina/instrumentação , Tecnologia sem Fio/instrumentação , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Telemedicina/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA