Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 99(3): 593-600, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34241947

RESUMO

BACKGROUND: In patients at high bleeding risk (HBR), the LEADERS FREE (LF) trial established the safety and efficacy of a polymer-free drug coated (Biolimus-A9) stainless steel stent (SS-DCS) with 30 days of dual antiplatelet treatment (DAPT). In LEADERS FREE III, we studied a new cobalt-chromium thin-strut stent (CoCr-DCS) in HBR patients. METHODS: The CoCr-DCS shares all of the design features of the SS-DCS but has a CoCr stent platform with strut thickness of 84-88 µm. The primary safety endpoint was a composite of cardiac death, myocardial infarction (MI), and definite/probable stent thrombosis. The primary efficacy endpoint was clinically indicated target lesion revascularization. Outcomes were compared to those of LF (non-inferiority to SS-DCS for safety and superiority to SS-BMS for efficacy). Additional propensity-matched comparisons were performed to account for baseline differences. RESULTS: We recruited 401 HBR patients using identical criteria to the LF trial. At 1 year, the primary safety endpoint was reached by 31/401 (8.0%) of patients treated with the CoCr-DCS versus 35/401 (8.9%) for the propensity-matched cohort (HR: 0.89, [0.55-1.44], p < 0.001 for non-inferiority, 0.62 for superiority). The efficacy endpoint was reached by 16/401 (4.2%) of CoCr-DCS patients versus 41/401 (10.6%) in the propensity-matched cohort (HR: 0.4 [0.2:0.7]) (p = 0.007 for superiority). There was no statistical difference between CoCr-DCS and SS-DCS in terms of efficacy (HR: 1.46 [0.68-3.15], p = 0.33). CONCLUSIONS: The new thin-strut CoCr-DCS proved non-inferior to the SS-DCS for safety, and superior to the BMS for efficacy in HBR patients treated with 30 days of DAPT.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Polímeros , Desenho de Prótese , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
2.
Open Heart ; 11(1)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890129

RESUMO

BACKGROUND: For high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT). The LEADERS FREE III (LF III) trial investigated clinical outcomes after PCI with the next-generation cobalt-chromium thin-strut polymer-free biolimus-coated stent (CoCr-BCS) in HBR patients. AIMS: To report the final 3-year results of the LF III trial and compare them to LF II. METHODS: LF III was a prospective, multicentre, open-label single-arm study to evaluate the safety and efficacy of the CoCr-BCS stent. The primary safety endpoint was the composite of cardiac death (CD), myocardial infarction(MI) or definite/probable stent thrombosis (ST). The primary efficacy endpoint was clinically driven target lesion revascularisation (cd-TLR). We performed a propensity-matched comparison to the 3-year outcomes of LF II. RESULTS: After 3 years, CD/MI/ST had occurred in 57 patients (15%, 95% CI 11.8% to 19%) and cd-TLR in 23 (6.2%, 95% CI 4.1% to 9.2%) patients. In a propensity-matched comparison of patients treated with the CoCr-BCS versus the SS-BCS, there were similar rates of CD (6.6% vs 7.8%, p=0.50), MI (7.1% vs 8.3%, p=0.47) and definite/probable ST (1.1% vs 2%, HR 0.56, 95% CI 0.16 to 1.93, p=0.35). The rates of cd-TLR were 5.3% with CoCr-BCS versus 9.8% with SS-BCS (HR 0.54, 95% CI 0.31 to 0.96, p=0.03). CONCLUSION: LF III confirms the long-term safety and efficacy of the CoCr-BCS in HBR patients treated with 1 month of DAPT. TRIAL REGISTRATION NUMBER: NCT02843633, NCT03118895.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Masculino , Estudos Prospectivos , Feminino , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Sirolimo/administração & dosagem , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Idoso , Fatores de Tempo , Pessoa de Meia-Idade , Seguimentos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco
3.
EuroIntervention ; 17(3): 233-239, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33433389

RESUMO

BACKGROUND: The BioFreedom drug-coated stent with a stainless steel platform (BF-SS) has been demonstrated to be efficacious in patients at high bleeding risk and receiv-ing only one-month dual antiplatelet therapy. AIMS: The aim of this study was to evaluate the efficacy of the new BioFreedom Ultra drug-coated stent with a thin-strut cobalt-chromium platform (BF-CoCr) compared to the BF-SS in an all-comers population undergoing percutaneous coronary intervention (PCI). METHODS: This was a prospective, multicentre, non-inferiority trial. The primary endpoint was in-stent late lumen loss (LLL) as determined by quantitative coronary angiography at nine-month follow-up. Clinical evaluation was performed at one year. RESULTS: A total of 200 patients were randomised (1:1) to either the BF-CoCr or the BF-SS stent at eight centres in Spain and Denmark. Baseline clinical and lesion characteristics were similar between the groups. Mean age was 66 years and 23% were female. The mean number of stents implanted per patient was 1.5. At nine-month follow-up, mean in-stent LLL was 0.34±0.49 mm in the BF-CoCr group versus 0.29±0.37 mm in the BF-SS group, p=0.005 for non-inferiority. At one year, target lesion failure was similar between the groups (7.3% in BF-CoCr vs 9.3% in the BF-SS group; p=0.60). CONCLUSIONS: The BF-CoCr was non-inferior to the BF-SS in terms of in-stent LLL at nine months. Larger studies powered for clinical endpoints are warranted to compare the efficacy of this new platform with currently available DES.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Idoso , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/uso terapêutico , Espanha , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA