Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 44(12): 1963-1971, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34586643

RESUMO

BACKGROUND: Optimization of cardiac resynchronization therapy (CRT) is often time-consuming and therefore underused in a clinical setting. Novel device-based algorithms aiming to simplify optimization include a dynamic atrioventricular delay (AVD) algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott). This study examines the acute effect of SyncAV and MPP on electrical synchrony in patients with newly and chronically implanted CRT devices. METHODS: Patients with SyncAV and MPP enabled devices were prospectively enrolled during implant or scheduled follow-up. Blinded 12-lead electrocardiographic acute measurements of QRS duration (QRSd) were performed for intrinsic QRSd (Intrinsic), bi-ventricular pacing (BiV), MPP, BiV with SyncAV at default offset 50 ms (BiVSyncAVdef ), BiV with SyncAV at patient-specific optimised offset (BiVSyncAVopt ), MPP with SyncAV at default offset 50 ms (MPPSyncAVdef ), and MPP with SyncAV at patient-specific optimised offset (MPPSyncAVopt ). RESULTS: Thirty-three patients were enrolled. QRSd for Intrinsic, BiV, MPP, BiVSyncAVdef , BiVSyncAVopt , MPPSyncAVdef , MPPSyncAVopt were 160.4 ± 20.6 ms, 141.0 ± 20.5 ms, 130.2 ± 17.2 ms, 121.7 ± 20.9 ms, 117.0 ± 19.0 ms, 121.2 ± 17.1 ms, 108.7 ± 16.5 ms respectively. MPPSyncAVopt led to greatest reduction of QRSd relative to Intrinsic (-31.6 ± 11.1%; p < .001), showed significantly shorter QRSd compared to all other pacing configurations (p < .001) and shortest QRSd in every patient. Shortening of QRSd was not significantly different between newly and chronically implanted devices (-51.6 ± 14.7 ms vs. -52.7 ± 21.9 ms; p = .99). CONCLUSION: SyncAV and MPP improved acute electrical synchrony in CRT. Combining both technologies with patient-specific optimization resulted in greatest improvement, regardless of time since implantation. Whats new Novel device-based algorithms like a dynamic AVD algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott) aim to simplify CRT optimization. Our data show that a combination of patient tailored SyncAV optimization and MPP results in greatest improvement of electrical synchrony in CRT measured by QRS duration, regardless if programmed in newly or chronically implanted devices. This is the first study to our knowledge to examine a combination of these device-based algorithms. The results help understanding the ideal ventricular excitation in heart failure.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/terapia , Idoso , Eletrocardiografia , Feminino , Alemanha , Humanos , Masculino , Estudos Prospectivos
2.
Nutr Metab Cardiovasc Dis ; 31(3): 860-868, 2021 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-33549449

RESUMO

BACKGROUND AND AIMS: Oral anticoagulation is effective for stroke prevention in atrial fibrillation (AF). However, strokes may still occur in high-risk individuals. We conducted a prospective trial to assess the association between adipocytokine serum levels and surrogate parameters for thromboembolic events. METHODS AND RESULTS: In this cross-sectional multicenter trial, we enrolled 189 patients with AF who were on oral anticoagulation. The primary endpoint was defined as either the presence of spontaneous echo contrast (SEC), a left atrial appendage (LAA), or a left atrial (LA) thrombus on transesophageal echocardiography. We investigated the association of adipocytokine serum levels with the combined endpoint using logistic regression analysis. Forty-eight individuals (25%) were assigned to group 1 (G1) due to the occurrence of at least one of the components of the combined endpoint (41 [21.7%] SEC, 3 [1.6%] LA thrombus, 13 [6.9%] LAA thrombus), whereas the remaining patients formed group 2 (G2). The BMI, logarithmized (loge) leptin (G1: 2.0 ± 1.3 µg/ml, G2: 2.0 ± 1.1 µg/ml, p = 0.746) and visfatin serum levels (G1: 3.4 ± 0.3 ng/ml, G2: 3.4 ± 0.5 ng/ml, p = 0.900) did not significantly differ between the groups. Conversely, logarithmized adiponectin (G1: 3.3 ± 0.6 ng/ml, G2: 3.1 ± 0.7 ng/ml, p = 0.036) and resistin levels (G1: 1.8 ± 0.5 ng/ml, G2: 1.6 ± 0.5 ng/ml, p = 0.009) were higher in patients with the primary endpoint. Multivariate logistic regression analysis using a score that combined the individual adiponectin and resistin values in each patient corroborated this association. CONCLUSIONS: Our results suggest that adiponectin and resistin may act as potential biomarkers to identify individuals with AF who are at high thromboembolic risk.


Assuntos
Adipocinas/sangue , Anticoagulantes/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Trombose/prevenção & controle , Adiponectina/sangue , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico por imagem , Biomarcadores/sangue , Índice de Massa Corporal , Estudos Transversais , Citocinas/sangue , Ecocardiografia Transesofagiana , Feminino , Alemanha , Humanos , Leptina/sangue , Masculino , Pessoa de Meia-Idade , Nicotinamida Fosforribosiltransferase/sangue , Estudos Prospectivos , Resistina/sangue , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/diagnóstico , Tromboembolia/sangue , Tromboembolia/diagnóstico , Trombose/sangue , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
3.
Herz ; 46(Suppl 2): 222-227, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33026482

RESUMO

BACKGROUND: The prevalence of aortic valve stenosis is increasing due to the continuously growing geriatric population. Data on procedural success and mortality of very old patients are sparse, raising the question of when this population may be deemed as "too old even for transcatheter aortic valve replacement (TAVR)." We, therefore, sought to evaluate the influence of age on outcome after TAVR and the impact of direct implantation. METHODS: The data of 394 consecutive patients undergoing TF-TAVR were analyzed. Patients were divided into four age groups: ≤75 (group 1, n = 28), 76-80 (group 2, n = 107), 81-85 (group 3, n = 148), and >85 (group 4, n = 111) years. Direct implantation was performed when possible according to current recommendations. Survival was evaluated by Kaplan-Meier analysis. RESULTS: Mortality at 30 days and 1 year was not significantly different between the four age groups (3.6 vs. 6.7 vs. 5.4 vs. 2.7% and 7.6 vs. 17 vs. 14.5 vs. 13%m respectively, log-rank p = 0.59). Direct implantation without balloon aortic valvuloplasty was more frequently performed on patients aged >85 vs. ≤85 years (33.3 vs. 14.1%, p < 0.001). the incidence of procedural complications frequently associated with advanced age (stroke, vascular complications) was not significantly increased in group 4. CONCLUSION: Outcome after TF-TAVR is comparable among different age cohorts, even in very old patients. Direct implantation simplifies the procedure and could therefore play a role in reducing the incidence of peri-interventional complications in patients of advanced age.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
4.
Heart Lung Circ ; 25(1): 53-60, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26184126

RESUMO

BACKGROUND: Recent studies have suggested a strong association between obstructive sleep apnoea (OSA) and atrial fibrillation (AF). However, the impact of continuous positive airway pressure (CPAP) therapy on reverse atrial remodelling in patients with OSA is poorly understood. We aimed to determine the impact of CPAP therapy on total atrial conduction time measured by PA tissue Doppler imaging (TDI) interval in patients without history of AF. METHODS AND RESULTS: Thirty-five patients with first diagnosed OSA (group 1) and 20 reference patients without OSA (group 2) were prospectively enrolled. Group 1 was divided into 25 patients with starting CPAP therapy (intervention group) and 10 patients without CPAP therapy (control group). PA-TDI interval, measured by tissue Doppler imaging, and B-type natriuretic-peptide (BNP) were determined at baseline and repeated after 30 days in group 1. Patients with OSA had a significantly longer PA-TDI interval (131.4±16.0 ms vs. 120.1±6.4 ms, p<0.001) compared to reference patients. PA-TDI interval shortened significantly after 30 days of CPAP therapy (131±17.1 ms vs. 124.6±15.7 ms, p<0.001), whereas no significant change was found in the control group (132.6±13.6 ms vs. 133.2±13.1 ms, p=0.31) and BNP-levels decreased significantly (39.1±50.7 pg/ml vs. 28.2±42.4 pg/ml, p<0.01), while BNP-levels remained unaffected after 30 days in control group (31.5±20 pg/ml vs. 34.4±20.5 pg/ml, p=0.41). CONCLUSIONS: Change in PA-TDI interval, as an indirect surrogate marker of atrial remodelling, suggests reverse atrial remodelling in patients with OSA and treated by CPAP. This effect may ensue from decreased atrial pressure or volume overload, as indicated by significantly reduced BNP levels. These observations suggest that the substrate pre-disposing to AF may be reversible and moreover can be measured by PA-TDI interval and BNP.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Peptídeo Natriurético Encefálico/sangue , Apneia Obstrutiva do Sono , Fibrilação Atrial/sangue , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/sangue , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia
5.
J Cardiovasc Electrophysiol ; 25(2): 161-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24118306

RESUMO

BACKGROUND: The aim of this study was to investigate whether total atrial conduction time (TACT) assessed via tissue Doppler imaging (PA-TDI interval) can identify patients with early recurrent atrial fibrillation (ERAF) after successful direct-current electrical cardioversion (CV) of persistent atrial fibrillation (persPAF). METHODS AND RESULTS: A total of 54 patients without antiarrhythmic drug medication (mean ± SD: 66 ± 10.4 years; 33% women) with persPAF and successful CV were enrolled between May 2012 and May 2013. TACT was measured 6 hours after successful CV in the left atrium by tissue Doppler imaging (PA-TDI interval). ERAF was determined via Holter-electrocardiogram over a period of 7 days after CV. Receiver opearting characteristic analysis was used to determine an optimal cutoff value of PA-TDI interval for prognosis of ERAF. Based on this result, recurrence-free survival was assessed with Mantel-Haenszel's log-rank test. ERAF occurred in 23 patients (43%). PA-TDI interval was longer in patients with ERAF compared to those who maintained sinus rhythm (mean ± SD: 163.5 ± 11.1 vs 132.3 ± 11.2 milliseconds; P < 0.00001). At the cutoff value of 152 milliseconds, PA-TDI interval sensitivity and specificity related to ERAF were 87% and 100%, respectively. CONCLUSION: Measuring PA-TDI interval may help to predict ERAF after successful CV in patients with persAF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/prevenção & controle , Ecocardiografia Doppler/métodos , Técnicas de Imagem por Elasticidade/métodos , Cardioversão Elétrica/métodos , Sistema de Condução Cardíaco/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Doença Crônica , Eletrocardiografia Ambulatorial , Feminino , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Condução Nervosa , Recidiva , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38383674

RESUMO

BACKGROUND: The aim of the present study was to evaluate the long-term safety and effectiveness of the subcutaneous implantable cardioverter defibrillator (S-ICD) when implanted intermuscularly in patients with end-stage renal disease and hemodialysis. METHODS: This study is a retrospective analysis of 21 consecutive patients implanted with S-ICDs at three experienced centers in Germany with comorbid renal insufficiency requiring hemodialysis, as well as being at risk of sudden cardiac death. The S-ICD was placed intermuscularly in all patients. Follow-ups (FUs) were performed every 6 months. RESULTS: The mean ± standard deviation FU duration was 60.0 ± 11.4 months, with a range of 39 to 78 months. There were no deaths due to arrhythmia, or device-associated infections and complications. Four patients (19.1%) died during FU due to respiratory insufficiency during dialysis, systolic heart failure, septic infection of the urogenital tract, and colorectal cancer, respectively. There were six non-device-related hospitalizations with a duration of 12.7 ± 5.1 days and a hospitalization rate of 4.1 per 100 patient years. CONCLUSIONS: In the long-term FU of this small population of seriously compromised hemodialysis patients at risk of sudden cardiac death, the intermuscularly implanted S-ICD system was safe and effective. No arrhythmic complications, device-associated infections, or complications compromised survival. These data are encouraging and support testing in a larger group of similarly compromised patients.

7.
J Clin Med ; 13(4)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38398357

RESUMO

BACKGROUND: Cephalic vein cutdown (CVC) and subclavian vein puncture (SVP) are the most commonly used access sites for transvenous lead placement of cardiac implantable electronic devices (CIEDs). Limited knowledge exists about the long-term patency of the vascular lumen housing the leads. METHODS: Among the 2703 patients who underwent CIED procedures between 2005 and 2013, we evaluated the phlebographies of 162 patients scheduled for an elective CIED replacement (median of 6.4 years after the first operation). The phlebographies were divided into four stenosis types: Type I = 0%, Type II = 1-69%, Type III = 70-99%, and Type IV = occlusion. Due to the fact that no standardized stenosis categorization exists, experienced physicians in consensus with the involved team made the applied distribution. The primary endpoint was the occurrence of stenosis Type III or IV in the CVC group and in the SVP group. RESULTS: In total, 162 patients with venography were enrolled in this study. The prevalence of high-degree stenosis was significantly lower in the CVC group (7/89, 7.8%) than in the SVP group (15/73, 20.5%, p = 0.023). In the CVC group, venographies showed a lower median stenosis (33%) than in the SVP group (median 42%). CONCLUSIONS: The present study showed that the long-term patency of the subclavian vein is higher after CVC than after SVP for venous access in patients with CIED.

8.
Cardiol Ther ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963510

RESUMO

INTRODUCTION: Coronary sclerosis is a risk factor for the progression to obstructive coronary artery disease (CAD). However, understanding its impact on the outcomes of patients with myocardial infarction and non-obstructive coronary arteries is limited. This study aimed to explore the prognostic influence of coronary sclerosis on in- and out-of-hospital events in troponin-positive patients with non-obstructive coronary arteries. METHODS: This study was a retrospective cohort analysis based on prospectively collected data. A total of 24,775 patients who underwent coronary angiography from 2010 to 2021 in a German university hospital were screened, resulting in a final study cohort of 373 troponin-positive patients with non-obstructive coronary arteries and a follow-up period of 6.2 ± 3.1 years. Coronary sclerosis was defined as coronary plaques without angiographically detectable stenotic lesions of 50% or more in the large epicardial coronary arteries. The primary study endpoint was the occurrence of in-hospital events. Secondary endpoints included events during follow-up. RESULTS: Patients with coronary sclerosis were significantly older (70 ± 12 vs. 58 ± 16 years, p < 0.001), had ST-segment elevation less frequently on electrocardiogram (9.4% vs. 18.7%, p = 0.013), and suffered more often from diabetes mellitus (23.3% vs. 13.1%, p = 0.009), arterial hypertension (79.6% vs. 59.8%, p < 0.001), chronic obstructive pulmonary disease (17.1% vs. 9.4%, p = 0.028), chronic kidney disease (22.2% vs. 8.4%, p < 0.001), atrial fibrillation (19.8% vs. 12.2%, p = 0.045), and valvular diseases than patients without CAD. Patients with coronary sclerosis were more likely to receive medication for primary/secondary prevention on admission and at discharge. The incidence of in- and out-of-hospital events was significantly higher in patients with coronary sclerosis (in-hospital: 42.8% vs. 29.9%, p = 0.010; out-of-hospital: 46.0% vs. 26.1%, p < 0.001). Mortality rates tended to be higher in the coronary sclerosis group (29.4% vs. 20.0%, p = 0.066). CONCLUSION: Patients diagnosed with coronary sclerosis presented a higher incidence of comorbidities and increased medication use, and experienced higher rates of both in-hospital and out-of-hospital events, primarily due to the clustering of cardiovascular risk factors.

9.
Front Cardiovasc Med ; 11: 1397138, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660482

RESUMO

Background: Patients with progressive chronic kidney disease (CKD) are at higher risk of infections and complications from cardiac implantable electronic devices (CIED). In patients with a primary or secondary prophylactic indication, implantable cardiac defibrillators (ICD) can prevent sudden cardiac deaths (SCD). We retrospectively compared transvenous-ICD (TV-ICD) and intermuscularly implanted subcutaneous-ICD (S-ICD) associated infections and complication rates together with hospitalizations in recipients with stage 4 kidney disease. Methods: We retrospectively analyzed 70 patients from six German centers with stage 4 CKD who received either a prophylactic TV-ICD with a single right ventricular lead, 49 patients, or a S-ICD, 21 patients. Follow-Ups (FU) were performed bi-annually. Results: The TV-ICD patients were significantly older. This group had more patients with a history of atrial arrhythmias and more were prescribed anti-arrhythmic medication compared with the S-ICD group. There were no significant differences for other baseline characteristics. The median and interquartile range of FU durations were 55.2 (57.6-69.3) months. During FU, patients with a TV-ICD system experienced significantly more device associated infections (n = 8, 16.3% vs. n = 0; p < 0.05), device-associated complications (n = 13, 26.5% vs. n = 1, 4.8%; p < 0.05) and device associated hospitalizations (n = 10, 20.4% vs. n = 1, 4.8%; p < 0.05). Conclusion: In this long-term FU of patients with stage 4 CKD and an indication for a prophylactic ICD, the S-ICD was associated with significantly fewer device associated infections, complications and hospitalizations compared with TV-ICDs.

10.
J Cardiovasc Electrophysiol ; 24(10): 1110-5, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23790081

RESUMO

BACKGROUND: We evaluated if preoperative serum apoptosis markers correlate with atrial histological remodeling and postoperative atrial fibrillation (POAF) after cardiac surgery. METHODS AND RESULTS: A total of 33 patients with sinus rhythm (SR) and without history of atrial fibrillation (AF) undergoing cardiac surgery were prospectively enrolled. Serum concentrations of Fas (apoptosis-stimulating fragment ligand) and TRAIL (tumor necrosis factor-related apoptosis-inducing ligand) were measured preoperatively. Right atrial appendage (RAA) tissue was obtained during surgery. Atrial apoptosis was assessed via TUNEL assay and degree of atrial fibrosis was categorized histologically by visual quantification. Continuous ECG-Monitoring was used to screen for POAF throughout 10 days after cardiac surgery. POAF occurred in 15 patients (45%). Atrial apoptosis was higher in patients with POAF as compared to those without (35.9 ± 9.8% vs 14.5 ± 7.5%; P < 0.0001) and correlated with the degree of atrial fibrosis (r = 0.69; P < 0.0001). In contrast to TRAIL (87.0 ± 8.2 pg/mL vs 83.3 ± 9.4 pg/mL; P = 0.77), preoperative Fas serum concentration was significantly higher in patients with POAF compared to patients in stable SR (91.3 ± 7.2 pg/mL vs 66.7 ± 3.0 pg/mL; P < 0.01). Serum Fas concentration correlated with the degree of atrial apoptosis (r = 0.63; P < 0.001) and the degree of atrial fibrosis (r = 0.39; P < 0.05). CONCLUSION: Preoperative evaluation of serum apoptosis marker Fas is useful to identify patients at risk for POAF undergoing cardiac surgery. Fas but not TRAIL correlates with the documented degree of atrial apoptosis and atrial fibrosis in RAA tissue. Further studies need to identify the prospective role of Fas in predicting POAF events.


Assuntos
Apoptose , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Proteína Ligante Fas/sangue , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Biomarcadores/sangue , Eletrocardiografia Ambulatorial , Feminino , Fibrose , Átrios do Coração/metabolismo , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Ligante Indutor de Apoptose Relacionado a TNF/sangue , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
11.
J Cardiovasc Electrophysiol ; 24(6): 626-31, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23398627

RESUMO

BACKGROUND: Recent studies identified total atrial conduction time (TACT) as an independent and powerful predictor of new-onset atrial fibrillation (AF). The purpose of this study was to assess the association between the degree of atrial fibrosis, TACT, and frequency of postoperative atrial fibrillation (POAF) among patients undergoing cardiac surgery. METHODS AND RESULTS: Sixty patients in sinus rhythm (mean ± SD age 66 ± 10 years; 22% women) and without a history of AF undergoing cardiac surgery were prospectively enrolled. TACT was measured preoperatively in the left atrium by tissue-Doppler Imaging (PA-TDI interval). Holter-ECG/telemetry was used to screen for POAF throughout 10 days after cardiac surgery. Right atrial appendages (RAA) were obtained in 33 patients during surgery; atrial fibrosis was assessed by visual quantification (% area of positive van Gieson elastic staining). POAF occurred in 23 patients (38%). Fibrosis extent of RAA was higher in patients with POAF as compared to those without (27.5 ± 1.93 vs 15.8 ± 0.81% area; mean ± SEM; P < 0.001). PA-TDI interval was longer in patients with POAF versus patients who maintained in sinus rhythm (152.1 ± 3.0 vs 120.8 ± 1.8 milliseconds; P < 0.001) and correlated with the degree of atrial fibrosis (r = 0.73; P < 0.01). At the cut-off value of 133 milliseconds, TACT sensitivity and specificity related to POAF were 100% and 86%, respectively. CONCLUSION: PA-TDI interval is useful to identify patients at risk for POAF undergoing cardiac surgery and correlates with the degree of atrial fibrosis.


Assuntos
Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos , Átrios do Coração/patologia , Sistema de Condução Cardíaco/fisiologia , Complicações Pós-Operatórias , Idoso , Fibrilação Atrial/patologia , Ponte de Artéria Coronária , Ecocardiografia Doppler , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade
12.
Front Cardiovasc Med ; 10: 1176710, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252123

RESUMO

Background: The wearable cardioverter defibrillator (WCD), (LifeVest, ZOLL, Pittsburgh, PA, USA) is a medical device designed for the temporary detection and treatment of malignant ventricular tachyarrhythmias. WCD telemonitoring features enable the evaluation of the physical activity (PhA) of the patients. We sought to assess with the WCD the PhA of patients with newly diagnosed heart failure. Methods: We collected and analyzed the data of all patients treated with the WCD in our clinic. Patients with newly diagnosed ischemic, or non-ischemic cardiomyopathy and severely reduced ejection fraction, who were treated with the WCD for at least 28 consecutive days and had a compliance of at least 18 h the day were included. Results: Seventy-seven patients were eligible for analysis. Thirty-seven patients suffered from ischemic and 40 from non-ischemic heart disease. The average days the WCD was carried was 77.3 ± 44.6 days and the mean wearing time was 22.8 ± 2.1 h. The patients showed significantly increased PhA measured by daily steps between the first two and the last two weeks (Mean steps in the first 2 weeks: 4,952.6 ± 3,052.7 vs. mean steps in the last 2 weeks: 6,119.6 ± 3,776.2, p-value: < 0.001). In the end of the surveillance period an increase of the ejection fraction was observed (LVEF-before: 25.8 ± 6.6% vs. LVEF-after: 37.5 ± 10.6%, p < 0.001). Improvement of the EF did not correlate with the improvement of PhA. Conclusion: The WCD provides useful information regarding patient PhA and may be additionally utilized for early heart failure treatment adjustment.

13.
Sci Rep ; 13(1): 22964, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-38151554

RESUMO

There is a rising number in complications associated with more cardiac electrical devices implanted (CIED). Infection and lead dysfunction are reasons to perform transvenous lead extraction. An ideal anaesthetic approach has not been described yet. Most centres use general anaesthesia, but there is a lack in studies looking into deep sedation (DS) as an anaesthetic approach. We report our retrospective experience for a large number of procedures performed with deep sedation as a primary approach. Extraction procedures performed between 2011 and 2018 in our electrophysiology laboratory have been included retrospectively. We began by applying a bolus injection of piritramide followed by midazolam as primary medication and would add etomidate if necessary. For extraction of leads a stepwise approach with careful traction, locking stylets, dilator sheaths, mechanical rotating sheaths and if needed snares and baskets has been used. A total of 780 leads in 463 patients (age 69.9 ± 12.3, 31.3% female) were extracted. Deep sedation was successful in 97.8% of patients. Piritramide was used as the main analgesic medication (98.5%) and midazolam as the main sedative (94.2%). Additional etomidate was administered in 15.1% of cases. In 2.2% of patients a conversion to general anaesthesia was required as adequate level of DS was not achieved before starting the procedure. Sedation related complications occurred in 1.1% (n = 5) of patients without sequalae. Deep sedation with piritramide, midazolam and if needed additional etomidate is a safe and feasible strategy for transvenous lead extraction.


Assuntos
Anestésicos , Sedação Profunda , Desfibriladores Implantáveis , Etomidato , Marca-Passo Artificial , Humanos , Feminino , Masculino , Midazolam/efeitos adversos , Estudos Retrospectivos , Pirinitramida , Sedação Profunda/efeitos adversos , Sedação Profunda/métodos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos
14.
J Clin Med ; 12(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38137682

RESUMO

BACKGROUND: Infection, lead dysfunction and system upgrades are all reasons that transvenous lead extraction is being performed more frequently. Many centres focus on a single method for lead extraction, which can lead to either lower success rates or higher rates of major complications. We report our experience with a systematic approach from a less invasive to a more invasive strategy without the use of laser sheaths. METHODS: Consecutive extraction procedures performed over a period of seven years in our electrophysiology laboratory were included. We performed a stepwise approach with careful traction, lead locking stylets (LLD), mechanical non-powered dilator sheaths, mechanical powered sheaths and, if needed, femoral snares. RESULTS: In 463 patients (age 69.9 ± 12.3, 31.3% female) a total of 780 leads (244 ICD leads) with a mean lead dwelling time of 5.4 ± 4.9 years were identified for extraction. Success rates for simple traction, LLD, mechanical non-powered sheaths and mechanical powered sheaths were 31.5%, 42.7%, 84.1% and 92.6%, respectively. A snare was used for 40 cases (as the primary approach for 38 as the lead structure was not intact and stepwise approach was not feasible) and was successful for 36 leads (90.0% success rate). Total success rate was 93.1%, clinical success rate was 94.1%. Rate for procedural failure was 1.1%. Success for less invasive steps and overall success for extraction was associated with shorter lead dwelling time (p < 0.001). Major procedure associated complications occurred in two patients (0.4%), including one death (0.2%). A total of 36 minor procedure-associated complications occurred in 30 patients (6.5%). Pocket hematoma correlated significantly with uninterrupted dual antiplatelet therapy (p = 0.001). Pericardial effusion without need for intervention was associated with long lead dwelling time (p = 0.01) and uninterrupted acetylsalicylic acid (p < 0.05). CONCLUSION: A stepwise approach with a progressive invasive strategy is effective and safe for transvenous lead extraction.

15.
Front Cardiovasc Med ; 8: 734666, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34881300

RESUMO

Background: Bipolar active fixation (BipolarAFL) and quadripolar passive fixation left-ventricular leads (QuadPFL) have been designed to reduce the risk of phrenic nerve stimulation (PNS), enable targeted left-ventricular pacing, and overcome problems of difficult coronary venous anatomy and lead dislodgment. This study sought to report the long-term safety and performance of a BipolarAFL, Medtronic Attain Stability 20066, compared to QuadPFL. Methods: We performed a single-operator retrospective analysis of 81 patients receiving cardiac resynchronization therapy (CRT) (36 BipolarAFL, 45 QuadPFL). Immediate implant data and electrical and clinical data during follow-up (FU) were analyzed. Results: BipolarAFL has been chosen in patients with significantly larger estimated vein diameter (at the lead tip: 7.2 ± 4.1 Fr vs. 4.1 ± 2.3 Fr, p < 0.001) without significant time difference until the final lead position was achieved (BipolarAFL: 20.9 ± 10.5 min, vs. QuadPFL: 18.9 ± 8.9 min, p = 0.35). At 12 month FU no difference in response rate to CRT was recorded between BipolarAFL and QuadPFL according to left ventricular end-systolic volume (61.1 vs. 60.0%, p = 0.82) and New York Heart Association (66.7 vs. 62.2%, p = 0.32). At median FU of 48 months (IQR: 44-54), no lead dislodgment occurred in both groups but a significantly higher proportion of PNS was recorded in QuadPFL (13 vs. 0%, p < 0.05). Electrical parameters were stable during FU in both groups without significant differences. Conclusion: BipolarAFL can be implanted with ease in challenging coronary venous anatomy, shows excellent electrical performance and no difference in clinical outcome compared to QuadPFL.

16.
Front Cardiovasc Med ; 8: 738517, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34888359

RESUMO

Background: The relationship between thyroid function and cardiac disease is complex. Both hypothyroidism and thyrotoxicosis can predispose to ventricular arrhythmia and other major adverse cardiovascular events (MACE), so that a U-shaped relationship between thyroid signaling and the incidence of MACE has been postulated. Moreover, recently published data suggest an association between thyroid hormone concentration and the risk of sudden cardiac death (SCD) even in euthyroid populations with high-normal FT4 levels. In this study, we investigated markers of repolarization in ECGs, as predictors of cardiovascular events, in patients with a spectrum of subclinical and overt thyroid dysfunction. Methods: Resting ECGs of 100 subjects, 90 patients (LV-EF > 45%) with thyroid disease (60 overt hyperthyroid, 11 overt hypothyroid and 19 L-T4-treated and biochemically euthyroid patients after thyroidectomy or with autoimmune thyroiditis) and 10 healthy volunteers were analyzed for Tp-e interval. The Tp-e interval was measured manually and was correlated to serum concentrations of thyroid stimulating hormone (TSH), free triiodothyronine (FT3) and thyroxine (FT4). Results: The Tp-e interval significantly correlated to log-transformed concentrations of TSH (Spearman's rho = 0.30, p < 0.01), FT4 (rho = -0.26, p < 0.05), and FT3 (rho = -0.23, p < 0.05) as well as log-transformed thyroid's secretory capacity (SPINA-GT, rho = -0.33, p < 0.01). Spearman's rho of correlations of JT interval to log-transformed TSH, FT4, FT3, and SPINA-GT were 0.51 (p < 1e-7), -0.45 (p < 1e-5), -0.55 (p < 1e-8), and -0.43 (p < 1e-4), respectively. In minimal multivariable regression models, markers of thyroid homeostasis correlated to heart rate, QT, Tp-e, and JT intervals. Group-wise evaluation in hypothyroid, euthyroid and hyperthyroid subjects revealed similar correlations in all three groups. Conclusion: We observed significant inverse correlations of Tp-e and JT intervals with FT4 and FT3 over the whole spectrum of thyroid function. Our data suggest a possible mechanism of SCD in hypothyroid state by prolongation of repolarization. We do not observe a U-shaped relationship, so that the mechanism of SCD in patients with high FT4 or hyperthyroidism seems not to be driven by abnormalities in repolarization.

17.
Herzschrittmacherther Elektrophysiol ; 31(1): 64-72, 2020 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-32034475

RESUMO

Malfunctions in implanted pacemaker and defibrillator systems can affect all components of the device (battery, capacitor, central processing unit (CPU), connector, soldering points, electrodes). The resulting problems can manifest themselves as inadequate therapy, a lack of therapy despite the need for stimulation or shock release in case of ventricular tachyarrhythmia, or as an ineffective delivery of therapy. The high number of implanted pacemaker and defibrillator systems, the increased life expectancy and the technical progress of cardiac "device" therapy mean that the treating physician is confronted with increasingly complex problems in the follow-up. In addition to the knowledge of the basic function of these devices, a structured procedure to detect and treat malfunctions in a timely manner is required. In this review, frequent malfunctions of pacemaker and defibrillators are presented, individual problems are pointed out, and solutions and treatment options are shown.


Assuntos
Marca-Passo Artificial , Taquicardia Ventricular , Desfibriladores , Desfibriladores Implantáveis , Humanos
18.
Clin Res Cardiol ; 109(2): 183-193, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31152199

RESUMO

BACKGROUND: Multipoint pacing [Multipoint™ Pacing (MPP), Abbott] via a single left ventricular lead (Quartet™ LV lead, Abbott) improves acute left ventricular (LV) function and response to cardiac resynchronization therapy (CRT). Aim of this study was to examine additional benefits in terms of LV reverse remodeling and CRT response by activating MPP in responders and non-responders to conventional biventricular pacing (CONV). METHODS: 43 consecutive patients receiving CRT (Quadra Assura MP™, Abbott) received LV dP/dtmax optimized CONV programming for 6 months. MPP programming with large anatomical electrode separation (> 30 mm) and basal LV1 pacing location was activated afterwards. Echocardiographic and clinical parameters were obtained at baseline, 6- and 12-month follow-up (FU). The response was defined as an improvement of LVESV ≥ 15% and super-response as improvement ≥ 30% relative to baseline. RESULTS: 41 patients completed FU (one died of non-cardiac cause and one was lost to FU) and after 6 months CONV, 26 patients (63%) were classified as CRT responders. With MPP, the response rate increased to 90% (p < 0.001). Super-response also improved significantly with MPP compared to CONV (71% vs. 22%; p < 0.005). LV reverse remodeling in terms of LVESV improved significantly with MPP compared to CONV (79 ± 45 ml vs. 103 ± 64 ml; p < 0.001). NYHA-class only improved significantly with CONV relative to baseline (1,8 ± 0,7 vs. 2,7 ± 0,5; p < 0.001), but not further with MPP (1,7 ± 0,6 vs. 1,8 ± 0,7; p = 0.49). CONCLUSION: Multipoint pacing significantly improves response and super-response to CRT as well as LV reverse remodeling compared to conventional biventricular pacing.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Pressão Ventricular
19.
Int J Cardiol Heart Vasc ; 30: 100593, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32775601

RESUMO

BACKGROUND: Current recommendations for valve size selection are based on multidimensional annular measurements, yet the overlap between two different transcatheter heart valve (THV) sizes remains. We sought to evaluate whether undersizing but overfilling eliminates the gray zones of valve sizing. METHODS: Data of 246 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable bioprosthesis with either conventional sizing and nominal filling (group 1 (NF-TAVR), n = 154) or undersizing but overfilling under a Less Is More (LIM)-Principle (group 2 (LIM-TAVR), n = 92) were compared. Paravalvular leakage (PVL) was graded angiographically and quantitatively using invasive hemodynamics. RESULTS: Annulus rupture (AR) occurred only in group 1 (n = 3). Due to AR adequate evaluation of PVL was possible in 152 patients of group 1. More than mild PVL was found in 13 (8.6%) patients of group 1 and 1 (1.1%) patient of group 2 (p = 0.019). Postdilatation was performed in 31 (20.1%) patients of group 1 and 6 patients (6.5%) of group 2 (p = 0.003). For patients with borderline annulus size in group 1 (n = 35, 22.7%) valve size selection was left to the physicians choice resulting in selection of the larger prosthesis in 10 (28.6%). In group 2 all patients with borderline annulus (n = 36, 39.1%) received the smaller prosthesis (LIM-TAVR). The postprocedural mean transvalvular pressure gradient was significantly higher in the NF-TAVR-group (11.7 ± 4 vs. 10.1 ± 3.6 mmHg, p = 0.005). CONCLUSION: LIM-TAVR eliminates the gray zones of sizing and associated PVL, can improve THV-performance, reduce incidence of annular rupture and simplify the procedure especially in borderline cases.

20.
Clin Res Cardiol ; 108(8): 931-939, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30737530

RESUMO

BACKGROUND: Controversy exists about the pathophysiology of different hemodynamic subgroups of AS. In particular, the mechanism of the paradoxical low-flow, low-gradient (PLFLG) AS with preserved ejection fraction (EF) is unclear. METHODS: A total of 41 patients with severe, symptomatic AS were divided into the following 4 subgroups based on the echocardiographically determined hemodynamics: (1) normal-flow, high-gradient (NFHG) AS; (2) low-flow, high-gradient AS; (3) paradoxical low-flow, low-gradient (PLFLG) AS with preserved EF and (4) low-flow, low-gradient (LFLG) AS with reduced EF. As part of the comprehensive invasive examinations, the analyses of the PV loops were performed with the IntraCardiac Analyzer (CD-Leycom, The Netherlands). RESULTS: PLFLG was characterized by small left ventricular volumes as well as a decreased cardiac index, a decreased systolic contractility and a lower stroke work, than the conventional NFHG AS. Alterations in effective arterial elastance (2.36 ± 0.67 mmHg/ml in NFHG versus 3.01 ± 0.79 mmHg/ml in PLFLG, p = 0.036) and end-systolic elastance (3.72 ± 1.84 mmHg/ml in NFHG versus 5.53 ± 2.3 mmHg/ml in PLFLG, p = 0.040) indicated impaired vascular function and increased chamber stiffness. CONCLUSIONS: The present study suggests that the hemodynamics of PLFLG AS can be explained by two mechanisms: (1) stiffness of the small left ventricle with reduced contractility, and (2) increased afterload due to the impairment of vascular function. Both mechanisms have similarities to those of heart failure with preserved EF. This type of remodeling may explain the poor prognosis of PLFLG AS.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA