Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Phys Chem A ; 127(36): 7638-7645, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37656920

RESUMO

The Stokes-Einstein relation, which relates the diffusion coefficient of a molecule to its hydrodynamic radius, is commonly used to determine molecular sizes in chemical analysis methods. Here, we combine the size sensitivity of such diffusion-based methods with the structure sensitivity of Raman spectroscopy by performing Raman diffusion-ordered spectroscopy (Raman-DOSY). The core of the Raman-DOSY setup is a flow cell with a Y-shaped channel containing two inlets: one for the sample solution and one for the pure solvent. The two liquids are injected at the same flow rate, giving rise to two parallel laminar flows in the channel. After the flow stops, the solute molecules diffuse from the solution-filled half of the channel into the solvent-filled half at a rate determined by their hydrodynamic radius. The arrival of the solute molecules in the solvent-filled half of the channel is recorded in a spectrally resolved manner by Raman microspectroscopy. From the time series of Raman spectra, a two-dimensional Raman-DOSY spectrum is obtained, which has the Raman frequency on one axis and the diffusion coefficient (or equivalently, hydrodynamic radius) on the other. In this way, Raman-DOSY spectrally resolves overlapping Raman peaks arising from molecules of different sizes. We demonstrate Raman-DOSY on samples containing up to three compounds and derive the diffusion coefficients of small molecules, proteins, and supramolecules (micelles), illustrating the versatility of Raman-DOSY. Raman-DOSY is label-free and does not require deuterated solvents and can thus be applied to samples and matrices that might be difficult to investigate with other diffusion-based spectroscopy methods.

2.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124537, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38833889

RESUMO

Microspectroscopic imaging techniques based on spontaneous Raman scattering, Stimulated Raman Scattering (SRS), or fluorescence (with a selective dye) can be used to detect environmental microplastics (MPs) and determine their chemical as well as physical properties. The present study first focuses on optimizing the sample preparation, including a new design for a density separation apparatus and optimization of the Nile Red staining procedure. Tests were carried out with both white and colored reference materials, as well as environmental MPs in a suspended matter sample from the Rhine river. The new 'MESSY' system has a mean recovery of 95 ± 5.5 % (three polymer materials, in duplicate). The optimized Nile Red staining allows coarse categorization of MPs into "polar" vs. "non-polar" materials based on their Fluorescence Index (emission wavelength), but fluorescent additives in the polymer can cause misclassification. For unambiguous identification of the polymer type, Raman spectroscopy can be used. Even colored polymers, with or without Nile Red staining, were readily identified by Raman spectroscopy using a red laser (785 nm), except for particles containing carbon black. A Deep-UV Raman microscope (ex = 248.6 nm) was constructed, which allowed identification of all colored plastics, even those pigmented with carbon black. Since unsupervised mapping with spontaneous Raman is very slow, point measurements are preferably used after preselection of particles of interest based on fluorescence imaging. SRS is several orders of magnitude faster than spontaneous Raman mapping but requires multiple scans at different z-heights and at multiple wavenumber settings to detect and identify all particles. The results are expected to contribute to the development of suitable methodologies for the detection and identification of environmental microplastics.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124388, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38795525

RESUMO

Raman spectroscopy is a well-established method for chemical identification, with a wide variety of applications. The two major limitations are that fluorescence can hamper detection, and that Raman imaging is slow; it typically takes multiple hours to measure even a small surface area. We have developed a multimodal setup that mitigates these limitations. The setup has a point-scanning mode that allows for time-gated as well as continuous Raman spectroscopy, and both modes use an 80 MHz, 532 nm excitation laser with up to 20 W of power. The fluorescence suppression capabilities of the setup were demonstrated by comparing time-gated to continuous detection of a Dracaena leaf. Raman bands showed a 4-8 times improvement in signal-to-background ratio, and one band that was invisible in the continuous measurement, became visible in the time-gated measurement. The setup also has a 4-band simultaneously detected wide-field mode. Using a set of beam splitters, the Raman signal from the sample is split. This signal is imaged onto four separate cameras, each with a specific band-pass filter. The wide-field data were processed using principal component analysis with k-means clustering. To illustrate the wide-field capabilities of the setup, a 1mm2 sample containing aspirin, caffeine and paracetamol was measured using 10 W excitation power. A 10-second measurement enabled identification of the compounds, and a 1-second measurement showed promising results. This brings the setup close to real-time imaging, showing great potential for applications in quality control or for measuring samples that change over time.

4.
Nature ; 481(7381): 271-3, 2012 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-22258600
5.
Plast Reconstr Surg ; 152(6): 1191-1200, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36877628

RESUMO

BACKGROUND: Breast implant surgery is one of the most frequently performed procedures by plastic surgeons worldwide. However, the relationship between silicone leakage and the most common complication, capsular contracture, is far from understood. This study aimed to compare Baker grade I with Baker grade IV capsules regarding their silicone content in an intradonor setting, using two previously validated imaging techniques. METHODS: Twenty-two donor-matched capsules from 11 patients experiencing unilateral complaints were included after bilateral explantation surgery. All capsules were examined using both stimulated Raman scattering (SRS) imaging and staining with modified oil red O (MORO). Evaluation was done visually for qualitative and semiquantitative assessment and automated for quantitative analysis. RESULTS: Using both SRS and MORO techniques, silicone was found in more Baker grade IV capsules (eight of 11 and 11 of 11, respectively) than in Baker grade I capsules (three of 11 and five of 11, respectively). Baker grade IV capsules also showed significantly more silicone content compared with the Baker grade I capsules. This was true for semiquantitative assessment for both SRS and MORO techniques ( P = 0.019 and P = 0.006, respectively), whereas quantitative analysis proved to be significant for MORO alone ( P = 0.026 versus P = 0.248 for SRS, respectively). CONCLUSIONS: In this study, a significant correlation between capsule silicone content and capsular contracture is shown. An extensive and continued foreign body response to silicone particles is likely to be responsible. Considering the widespread use of silicone breast implants, these results affect many women worldwide and warrant a more focused research effort. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.


Assuntos
Implante Mamário , Implantes de Mama , Contratura , Humanos , Feminino , Silicones/efeitos adversos , Implantes de Mama/efeitos adversos , Implante Mamário/efeitos adversos , Implante Mamário/métodos , Remoção de Dispositivo/efeitos adversos , Contratura/etiologia , Contratura Capsular em Implantes/etiologia , Contratura Capsular em Implantes/cirurgia , Géis de Silicone/efeitos adversos
6.
J Biophotonics ; 13(5): e201960197, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32049417

RESUMO

Millions of women worldwide have silicone breast implants. It has been reported that implant failure occurs in approximately a tenth of patients within 10 years, and the consequences of dissemination of silicone debris are poorly understood. Currently, silicone detection in histopathological slides is based on morphological features as no specific immunohistochemical technique is available. Here, we show the feasibility and sensitivity of stimulated Raman scattering (SRS) imaging to specifically detect silicone material in stained histopathological slides, without additional sample treatment. Histology slides of four periprosthetic capsules from different implant types were obtained after explantation, as well as an enlarged axillary lymph node from a patient with a ruptured implant. SRS images coregistered with bright-field images revealed the distribution and quantity of silicone material in the tissue. Fast and high-resolution imaging of histology slides with molecular specificity using SRS provides an opportunity to investigate the role of silicone debris in the pathophysiology of implant-linked diseases.


Assuntos
Implantes de Mama , Diagnóstico por Imagem , Feminino , Humanos , Linfonodos , Silicones , Análise Espectral Raman
7.
Ment Health Clin ; 6(6): 266-276, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29955481

RESUMO

Glycine and related endogenous compounds (d-serine, d-alanine, sarcosine) serve critical roles in both excitatory and inhibitory neurotransmission and are influenced by a multitude of enzymes and transporters, including glycine transporter 1 and 2 (GlyT1 and GlyT2), d-amino acid oxidase (DAAO), serine racemase (SRR), alanine-serine-cysteine transporter 1 (Asc-1), and kynurenine aminotransferase (KAT). MEDLINE, Web of Science, and PsychINFO were searched for relevant human trials of compounds. Many studies utilizing exogenous administration of small molecule agonists of the glycineB site of n-methyl-d-aspartate receptor have been studied as have a growing number of glycine transporter type 1 (GlyT1) inhibitors. The clinical effects of these compounds are reviewed as are the potential effects of newer novel compounds.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA