Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 215(6): 1528-1538, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32991217

RESUMO

OBJECTIVE. The purpose of this study was to analyze the contribution of dual-energy CT (DECT) to radiologist interpretation in the emergency department (ED) to determine whether recommendations for follow-up imaging decrease. MATERIALS AND METHODS. Reports of all DECT studies performed in an ED in 2016 were reviewed. A board-certified radiologist noted the number of times a report indicated that use of DECT techniques contributed to radiologist interpretation. For studies containing DECT findings in the report, the mixed datasets, representing conventional CT images, were read again separately. The difference between the numbers of follow-up studies recommended after conventional CT and DECT was converted into U.S. dollars by use of the Medicare fee schedule to estimate a projected cost benefit due to any reduction in follow-up imaging. RESULTS. The study included 3159 cases. DECT findings potentially altered management in 298 (9.4%) cases, increased diagnostic confidence in 455 (14.4%) cases, provided relevant information in 174 (5.6%) cases, helped characterize an incidental finding in 44 (1.4%) cases, and were mentioned to be noncontributory in three (0.09%) cases. DECT was not mentioned in the report in 2272 cases (71.9%). DECT findings avoided 162-191 recommended follow-up MRI examinations, 21-28 CT examinations, and 2-25 US examinations compared with conventional CT alone. The DECT findings also prompted one additional recommended interventional angiography procedure, one ventilation-perfusion scan, and one imaging-guided biopsy. The projected net cost reduction was $52,991.53-61,598.44. CONCLUSION. DECT added value to routine ED imaging by increasing diagnostic confidence, leading to a reduction in the number of recommended follow-up studies and a projected cost benefit.


Assuntos
Serviço Hospitalar de Emergência , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste , Análise Custo-Benefício , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/economia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/economia , Procedimentos Desnecessários/economia
2.
Magn Reson Med ; 70(3): 705-10, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23001902

RESUMO

Cerebral blood volume maps are usually acquired using dynamic susceptibility contrast imaging which inherently limits the spatial resolution and signal to noise ratio of the images. In this study, we used ferumoxytol (AMAG Pharmaceuticals, Inc., Cambridge, MA), an FDA-approved compound, to obtain high-resolution cerebral blood volume maps with a steady-state approach in seven healthy volunteers. R2* maps (0.8 × 0.8 × 1 mm(3)) were acquired before and after injection of ferumoxytol and an intraindividual normalization protocol was used to obtain quantitative values. The results show excellent contrast between white and gray matter as well as fine highly detailed vascular structures. An average blood volume of 4% was found in the brain of all volunteers, consistent with prior literature values. A linear relationship was found between ferumoxytol dose (mg/kg) and ΔR2* (1/s) in gray (R(2) = 0.98) and white matter (R(2) = 0.98). A quadratic relationship was found in the sagittal sinus (R(2) = 0.98). The cerebral blood volume maps compare well with lower resolution dynamic susceptibility contrast-MRI and their use should improve the evaluation of small and heterogeneous lesions and facilitate intrapatient and interpatient comparisons.


Assuntos
Volume Sanguíneo , Circulação Cerebrovascular , Meios de Contraste , Óxido Ferroso-Férrico , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Magn Reson Med ; 67(2): 378-88, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21858858

RESUMO

Combined acquisition of gradient-echo and spin-echo signals in MRI time series reveals additional information for perfusion-weighted imaging and functional MRI because of differences in the sensitivity of gradient-echo and spin-echo measurements to the properties of the underlying vascular architecture. The acquisition of multiple echo trains within one time frame facilitates the simultaneous estimation of the transversal relaxation parameters R2 and R2*. However, the simultaneous estimation of these parameters tends to be incorrect in the presence of slice profile mismatches between signal excitation and subsequent refocusing pulses. It is shown here that improvements in pulse design reduced R2 and R2* estimation errors. Further improvements were achieved by augmented parameter estimation through the introduction of an additional parameter δ to correct for discordances in slice profiles to facilitate more quantitative measurements. Moreover, the analysis of time-resolved acquisitions revealed that the temporal stability of R2 estimates could be increased with improved pulse design, counteracting low contrast-to-noise ratios in spin-echo-based perfusion and functional MRI.


Assuntos
Algoritmos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Encéfalo/anatomia & histologia , Encéfalo/irrigação sanguínea , Humanos , Imagens de Fantasmas , Design de Software
4.
Magn Reson Med ; 68(3): 905-11, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22162074

RESUMO

Quantitative blood oxygenation level dependent approaches have been designed to obtain quantitative oxygenation information using MRI. A mathematical model is usually fitted to the time signal decay of a gradient-echo and spin-echo measurements to derive hemodynamic parameters such as the blood oxygen saturation or the cerebral blood volume. Although the results in rats and human brain have been encouraging, recent studies have pointed out the need for independent estimation of one or more variables to increase the accuracy of the method. In this study, a multiparametric quantitative blood oxygenation level dependent approach is proposed. A combination of arterial spin labeling and dynamic susceptibility contrast methods were used to obtain quantitative estimates of cerebral blood volume and cerebral blood flow. These results were combined with T 2 and T(2) measurements to derive maps of blood oxygen saturation or cerebral metabolic rate of oxygen. In 12 normal subjects, a mean cerebral blood volume of 4.33 ± 0.7%, cerebral blood flow of 43.8 ± 5.7 mL/min/100 g, blood oxygen saturation of 60 ± 6% and cerebral metabolic rate of oxygen 157 ± 23 µmol/100 g/min were found, which are in agreement with literature values. The results obtained in this study suggest that this methodology could be applied to study brain hypoxia in the setting of pathology.


Assuntos
Algoritmos , Encéfalo/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oximetria/métodos , Oxigênio/sangue , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Modelos Neurológicos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
5.
Magn Reson Med ; 68(1): 30-40, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22114040

RESUMO

In this study, a spin- and gradient-echo echo-planar imaging (SAGE EPI) MRI pulse sequence is presented that allows simultaneous measurements of gradient-echo and spin-echo dynamic susceptibility-contrast perfusion-weighted imaging data. Following signal excitation, five readout trains were acquired using spin- and gradient-echo echo-planar imaging, all of them with echo times of less than 100 ms. Contrast agent concentrations in brain tissue were determined based on absolute R2* and R(2) estimates rather than relative changes in the signals of individual echo trains, producing T(1)-independent dynamic susceptibility-contrast perfusion-weighted imaging data. Moreover, this acquisition technique enabled vessel size imaging through the simultaneous quantification of R2* and R(2), without an increase in acquisition time. In this work, the concepts of SAGE EPI pulse sequence and results in stroke and tumor imaging are presented. Overall, SAGE EPI combined the advantages of higher sensitivity to contrast agent passage of gradient-echo perfusion-weighted imaging with better microvascular selectivity of spin-echo perfusion-weighted imaging.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Meios de Contraste , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
6.
Magn Reson Med ; 63(4): 959-69, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373397

RESUMO

Multiecho echo-planar imaging (EPI) was implemented for blood-oxygenation-level-dependent functional MRI at 1.5 T and compared to single-echo EPI with and without parallel imaging acceleration. A time-normalized breath-hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1-3. Experiments were conducted in five human subjects, each scanned in three sessions. Across all reduction factors, both signal-to-fluctuation-noise ratio and the total number of activated voxels were significantly lower using a single-echo EPI pulse sequence compared with the multiecho approach. Signal-to-fluctuation-noise ratio and total number of activated voxels were also considerably reduced for nonaccelerated conventional single-echo EPI when compared to three-echo measurements with R = 2. Parallel imaging accelerated multiecho EPI reduced geometric distortions and signal dropout, while it increased blood-oxygenation-level-dependent signal sensitivity all over the brain, particularly in regions with short underlying T*(2). Thus, the presented method showed multiple advantages over conventional single-echo EPI for standard blood-oxygenation-level-dependent functional MRI experiments.


Assuntos
Mapeamento Encefálico/métodos , Imagem Ecoplanar/métodos , Algoritmos , Artefatos , Imagem Ecoplanar/instrumentação , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos
7.
Cancers (Basel) ; 11(5)2019 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-31052289

RESUMO

Computed tomography (CT) perfusion is a novel imaging method to determine tumor perfusion using a low-dose CT technique to measure iodine concentration at multiple time points. We determined if early changes in perfusion differ between primary renal tumors and metastatic tumor sites in patients with renal cell carcinoma (RCC) receiving targeted anti-angiogenic therapy. A total of 10 patients with advanced RCC underwent a CT perfusion scan at treatment baseline and at one week after initiating treatment. Perfusion measurements included blood volume (BV), blood flow (BF), and flow extraction product (FEP) in a total of 13 lesions (six primary RCC tumors, seven RCC metastases). Changes between baseline and week 1 were compared between tumor locations: primary kidney tumors vs metastases. Metastatic lesions had a greater decrease in BF (average BF difference ± standard deviation (SD): -75.0 mL/100 mL/min ± 81) compared to primary kidney masses (-25.5 mL/100 mL/min ± 35). Metastatic tumors had a wider variation of change in BF, BV and FEP measures compared to primary renal tumors. Tumor diameters showed little change after one week, but early perfusion changes are evident, especially in metastatic lesions compared to primary lesions. Future studies are needed to determine if these changes can predict which patients are benefiting from targeted therapy.

8.
Int J Cardiovasc Imaging ; 35(8): 1473-1481, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31016501

RESUMO

The purpose of this study was to assess in pediatric pulmonary artery (PA) reconstruction candidates the feasibility and added utility of preoperative chest computed tomography angiography (CTA) using dual-energy technique, from which perfused blood volume (PBV)/iodine maps can be generated as a surrogate of pulmonary perfusion. Pediatric PA reconstruction patients were prospectively recruited for a new dose-neutral dual-energy CTA protocol. For each case, the severity of anatomic PA obstruction was graded by two pediatric cardiovascular radiologists in consensus using a modified Qanadli index. PBV maps were qualitatively reviewed and auto-segmented using Siemens syngo.via software. Associations between Qanadli scores and PBV were assessed with Spearman correlation (r) and ROC analysis. Effective radiation doses were estimated from dose-length product and ICRP 103 k-factors, using cubic Hermite spline interpolation. 19 patients were recruited with mean (SD) age of 6.0 (5.1), 11 (57.9%) female, 11 (73.7%) anesthetized. Higher QS correlated with lower PBV, both on a whole lung (r = - 0.54, p < 0.001) and lobar (r = - 0.50, p < 0.001) basis. The lung with lowest absolute PBV was predictive of the lung with highest Qanadli score, with AUC of 0.70 (95% CI 0.47-0.93). Qualitatively, PBV maps were heterogeneous, corresponding to multifocal PA stenoses, with decreased iodine content in areas of most severe obstruction. In conclusion, dual-energy chest CTA is feasible for pediatric PA reconstruction candidates. PBV maps show deficits in regions of more severe anatomic obstruction and may serve as a novel biomarker in this population.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Multidetectores/métodos , Procedimentos de Cirurgia Plástica , Artéria Pulmonar/diagnóstico por imagem , Estenose de Artéria Pulmonar/diagnóstico por imagem , Procedimentos Cirúrgicos Vasculares , Adolescente , Fatores Etários , Criança , Pré-Escolar , Tomada de Decisão Clínica , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Imagem de Perfusão/métodos , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Circulação Pulmonar , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença , Estenose de Artéria Pulmonar/fisiopatologia , Estenose de Artéria Pulmonar/cirurgia
9.
J Thorac Imaging ; 34(6): 387-392, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30994517

RESUMO

PURPOSE: The purpose of this study was to evaluate the clinical utility of temporal resolution optimization (TR-Opt), a computed tomography (CT) postprocessing technique, in reducing aortic motion artifacts in blunt thoracic trauma patients. MATERIALS AND METHODS: This was an IRB-approved study of 61 patients with blunt thoracic trauma carried out between February 18 and September 6, 2014; the patients had been imaged using a standardized dual-source high-pitch (DSHP) CT protocol. Image raw data were retrospectively postprocessed using the TR-Opt algorithm (DSHP-TR-Opt) and compared with conventional images (DSHP). Diagnostic ability to confidently identify and exclude potential injuries and qualitative aortic motion artifacts using a 5-point Likert scale (1=absence of motion artifacts; 5=severe motion artifact) was graded by 2 readers at multiple thoracic locations. Signal-to-noise and contrast-to-noise ratios were generated as quantitative indices of image quality. RESULTS: Motion artifacts degrading interpretation and limiting diagnosis of aortic injuries were present in 45% (442/976) of the assessed regions on DSHP. TR-Opt algorithm eliminated motion artifacts in 85% of the motion-degraded areas (375/442), leaving persistent motion artifacts in only 15% (67/442). Motion artifacts were most improved at the interventricular septum (1±1 vs. 3±1), aortic valve (2±1 vs. 4±1.5), and ascending aorta (1±1 vs. 3±2, P<0.005). Mean aorta noise (NAo) was 41.7% higher in the DSHP-TR-Opt images (26.5 vs. 18.7 HU, P<0.0001). CONCLUSIONS: Temporal resolution optimized reconstruction is a raw data-based CT postprocessing technique that can be used to remove the majority of thoracic aortic motion artifacts that commonly degrade interpretation when imaging blunt thoracic trauma patients.


Assuntos
Aorta Torácica/diagnóstico por imagem , Movimento , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Traumatismos Torácicos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ferimentos não Penetrantes/diagnóstico por imagem , Adolescente , Adulto , Idoso , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
10.
Abdom Radiol (NY) ; 44(1): 355-361, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29980828

RESUMO

PURPOSE: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). METHODS: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1-5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen's κ test. RESULTS: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). CONCLUSIONS: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Invest Radiol ; 53(2): 63-69, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28915161

RESUMO

PURPOSE: The aim of this study was to determine whether dual-energy computed tomography (DECT) imaging is superior to conventional noncontrast computed tomography (CT) imaging for the detection of acute ischemic stroke. MATERIALS AND METHODS: This was a retrospective, single-center study of 40 patients who presented to the emergency department (ED) of a major, acute care, teaching center with signs and symptoms of acute stroke. Only those patients who presented to the ED within 4 hours of symptom onset were included in this study. All 40 patients received a noncontrast DECT of the head at the time of presentation. Each patient also received standard noncontrast CT of the head 24 hours after their initial presentation to the ED. "Brain edema" images were then reconstructed using 3-material decomposition with parameters adjusted to suppress gray/white matter contrast while preserving edema and increasing its conspicuity. The initial unenhanced, mixed images, brain edema, and 24-hour follow-up true noncontrast (TNC) images were reviewed and assigned Alberta Stroke Program Early CT scores. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. RESULTS: Of the 40 patients, 28 (70%) were diagnosed with an acute infarction. Brain edema reconstructions were better able to predict end infarction volume, with Alberta Stroke Program Early CT scores similar to the 24-hour follow-up TNC CT (7.75 vs 7.7; P > 0.05), whereas the mixed images routinely underestimated the extent of infarction (8.975 vs 7.7; P < 0.001). Initial TNC images had a sensitivity, specificity, PPV, and NPV of 80% (95% confidence interval [CI], 51.9%-95.7%), 72.7% (95% CI, 39%-94%), 80% (95% CI, 51.9%-95.7%), and 72.73% (95% CI, 51.91%-95.67%), respectively. The DECT brain edema images provided a sensitivity, specificity, PPV, and NPV of 93.33% (95% CI, 68.05%-99.83%), 100% (95% CI, 71.51%-100%), 100% (95% CI, 76.84%-100%), and 91.67% (95% CI, 61.52%-99.79%), respectively. There was very good interrater reliability across all 3 imaging techniques. CONCLUSION: Brain edema reconstructions are able to more accurately detect edema and end-infarct volume as compared with initial TNC images. This provides a better assessment of the degree and extent of infarction and may serve to better guide therapy in the future.


Assuntos
Edema Encefálico/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Edema Encefálico/complicações , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/complicações
12.
Abdom Radiol (NY) ; 42(4): 1132-1140, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28008455

RESUMO

PURPOSE: To evaluate the capacity of perfusion CT imaging to distinguish between complete and incomplete responders after neoadjuvant chemoradiation therapy for rectal carcinoma, with particular attention to segmentation technique. MATERIALS AND METHODS: 17 patients were evaluated in this prospective IRB-approved study. For each patient, a perfusion CT acquisition was obtained prior to the initiation of chemoradiation, at 1-2 weeks after the start of chemoradiation, and at 12 weeks after the start of chemoradiation therapy. From each dataset, three perfusion parameters were measured, each in two different ways: a region of interest incorporating only "hot spots" of greatest enhancement and whole-tumor measurements. RESULTS: In univariate analysis, blood volume and permeability differed significantly between responders and non-responders. In logistic regression analysis evaluating predictors of the "complete response" outcome, only two predictors were retained as statistically significant: peak hot spot blood volume 1-2 weeks into therapy (OR 10.25, p = 0.0026) and hot spot permeability decline at 12 weeks after the initiation of therapy (OR 5.62, p = 0.03). The overall likelihood ratio test for this model supported the conclusion that hot spot blood volume and hot spot permeability decline were significant predictors of the complete pathologic response outcome (p < 0.0001). CONCLUSION: In this pilot study, peak tumor blood volume and decline in tumor permeability, when measured in "hot spots" of greatest enhancement, were strong predictors of complete therapeutic response in rectal cancer after neoadjuvant therapy.


Assuntos
Quimiorradioterapia , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Neoplasias Retais/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estudos Prospectivos , Resultado do Tratamento , Carga Tumoral
13.
Neuroradiol J ; 28(2): 112-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25923677

RESUMO

UNLABELLED: Bevacizumab (BEV) is increasingly used to treat recurrent glioblastoma (GBM) with some reported improvement in neurocognitive function despite potential neurotoxicities. We examined the effects of BEV on cerebral blood flow (CBF) within recurrent GBM tumor and in the contralateral middle cerebral artery (MCA) territory.Post-chemoradiation patients with histologically confirmed GBM were treated with BEV and underwent routine, serial tumor imaging with additional pseudocontinuous arterial spin labeling (pcASL) following informed consent. Circular regions-of-interest were placed on pcASL images directly over the recurrent tumor and in the contralateral MCA territory. CBF changes before and during BEV treatment were evaluated in tumor and normal tissue. Linear mixed models were used to assess statistical significance.Fifty-three pcASL studies in 18 patients were acquired. Evaluation yielded lower mean tumoral CBF during BEV treatment compared with pre-treatment (45 ± 27 vs. 65 ± 27 ml/100 g/min, p = 0.002), and in the contralateral MCA territory during, compared with pre-BEV treatment (35 ± 8.4 vs. 41 ± 8.4 ml/100 g/min, p = 0.03). The decrease in mean CBF tended to be greater in the tumoral region than in the contralateral MCA, though the difference did not reach statistical significance (31% vs. 13%; p = 0.082). CONCLUSIONS: BEV administration results in statistically significant global CBF decrease with a potentially preferential decrease in tumor perfusion compared with normal brain tissue.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/fisiopatologia , Circulação Cerebrovascular/efeitos dos fármacos , Glioblastoma/tratamento farmacológico , Glioblastoma/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/uso terapêutico , Bevacizumab , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Neoplasias Encefálicas/patologia , Feminino , Glioblastoma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
14.
J Cereb Blood Flow Metab ; 33(5): 732-43, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23462570

RESUMO

The purpose of this study was to estimate magnetic resonance imaging-based brain perfusion parameters from combined multiecho spin-echo and gradient-echo acquisitions, to correct them for T1₋, T2₋, and T2₋*-related contrast agent (CA) extravasation effects, and to simultaneously determine vascular permeability. Perfusion data were acquired using a combined multiecho spin- and gradient-echo (SAGE) echo-planar imaging sequence, which was corrected for CA extravasation effects using pharmacokinetic modeling. The presented method was validated in simulations and brain tumor patients, and compared with uncorrected single-echo and multiecho data. In the presence of CA extravasation, uncorrected single-echo data resulted in underestimated CA concentrations, leading to underestimated single-echo cerebral blood volume (CBV) and mean transit time (MTT). In contrast, uncorrected multiecho data resulted in overestimations of CA concentrations, CBV, and MTT. The correction of CA extravasation effects resulted in CBV and MTT estimates that were more consistent with the underlying tissue characteristics. Spin-echo perfusion data showed reduced large-vessel blooming effects, facilitating better distinction between increased CBV due to active tumor progression and elevated CBV due to the presence of cortical vessels in tumor proximity. Furthermore, extracted permeability parameters were in good agreement with elevated T1-weighted postcontrast signal values.


Assuntos
Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/patologia , Encéfalo/irrigação sanguínea , Encéfalo/patologia , Meios de Contraste , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/patologia , Encéfalo/metabolismo , Neoplasias Encefálicas/metabolismo , Permeabilidade Capilar , Circulação Cerebrovascular , Meios de Contraste/farmacocinética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA