Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037296

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Desenho de Prótese
2.
Am Heart J ; 247: 112-122, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35149038

RESUMO

BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Implante de Prótese de Valva Cardíaca , Embolia Intracraniana , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Encéfalo/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 100(7): 1291-1299, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36378678

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is independently associated with increased morbidity and mortality. Percutaneous transcatheter approaches may offer an alternative for patients not amenable to surgery. METHODS: TriCLASP is a prospective, single-arm, multicenter European post-market clinical follow-up study (NCT04614402) to evaluate the safety and performance of the PASCAL system (Edwards Lifesciences) in patients with severe or greater TR. At 30 days, a composite of major adverse events (MAEs) adjudicated by a clinical events committee, echocardiographic parameters adjudicated by core laboratory, and clinical, functional, and quality-of-life measures were evaluated. RESULTS: Mean age of the 74 enrolled patients was 80.3 years, with 58.1% female, 90.5% systemic hypertension, and 77.0% in New York Heart Association (NYHA) class III/IV. Mean Society for Thoracic Surgeons score (MV repair) was 9.0%. TR severity was significantly reduced at discharge (p < 0.001) and sustained at 30 days (p < 0.001), and 90.0% of patients achieved ≤moderate TR. The composite MAE rate at 30 days was 3.0%, including 4 events in 2 patients: cardiovascular mortality 1.5%, stroke 1.5%, renal complications requiring unplanned dialysis or renal replacement therapy 1.5%, and severe bleeding 1.5%. There were no nonelective tricuspid valve reinterventions, major access site and vascular complications, major cardiac structural complications, or device embolizations. NYHA class I/II was achieved in 55.8%, 6-minute walk distance improved by 38.2 m (p < 0.001), and Kansas City cardiomyopathy questionnaire scores improved by 13.4 points (p < 0.001). CONCLUSION: Experience with the PASCAL transcatheter valve repair system in a European post-market setting confirms favorable safety and effectiveness at 30 days. TR significantly reduced, and clinical, functional, and quality-of-life outcomes significantly improved. This study is ongoing. Clinical Trial Registration: The study is ongoing and registered on ClinicalTrials.gov as NCT04614402. The current analysis is an interim report.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Índice de Gravidade de Doença
4.
Thorac Cardiovasc Surg ; 69(5): 428-436, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32114689

RESUMO

BACKGROUND: We herein aimed for analysis of influence of mitral annular calcification (MAC) and mitral stenosis (MS) on outcomes in transcatheter aortic valve implantation (TAVI). METHODS: Between 11/2009 and 06/2017, 1,058 patients underwent TAVI in the presence of concomitant MAC or MS at our center. Subgroups were built and multivariate logistic regression, COX regression, Kaplan-Meier survival analyses, and receiver operating characteristics method were performed. RESULTS: Thirty-day mortality was 7.5% (79/1,058) with highest mortality in patients severe MS (MAC: 3.4% vs. mild MS: 5.9% vs. moderate MS: 15.0% vs. severe MS: 72.7%; p < 0.001). Moderate-to-severe MS (odds ratio [OR]: 7.75, confidence interval [CI]: 3.94-16.26, p < 0.001), impaired left ventricular ejection fraction (OR: 1.38, CI: 1.10-1.72, p < 0.01), and coronary artery disease (OR: 1.36, CI: 1.11-1.67, p < 0.01) were predictive of 30-day survival. Left ventricular systolic/end-diastolic pressure drop of <59.5 mm Hg / <19.5 mm Hg was associated with increased mortality. CONCLUSIONS: TAVI in the presence of MAC and mild MS is associated with acceptable acute outcomes but should be considered high-risk procedures in patients with moderate and especially those with severe MS. Our results suggest adverse hemodynamics after TAVI with concomitant MS, which may be caused by underfilling of the left ventricle leading to low-cardiac output.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Calcinose/fisiopatologia , Hemodinâmica , Estenose da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Am Heart J ; 225: 138-148, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32502877

RESUMO

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/classificação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico
7.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31230081

RESUMO

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Assuntos
Embolia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Embolia/epidemiologia , Embolia/etiologia , Embolia/mortalidade , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
8.
Eur Heart J ; 40(5): 441-451, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30357365

RESUMO

Aims: We sought to evaluate the outcomes of transcatheter mitral valve replacement (TMVR) for patients with degenerated bioprostheses [valve-in-valve (ViV)], failed annuloplasty rings [valve-in-ring (ViR)], and severe mitral annular calcification [valve-in-mitral annular calcification (ViMAC)]. Methods and results: From the TMVR multicentre registry, procedural and clinical outcomes of ViV, ViR, and ViMAC were compared according to Mitral Valve Academic Research Consortium (MVARC) criteria. A total of 521 patients with mean Society of Thoracic Surgeons score of 9.0 ± 7.0% underwent TMVR (322 patients with ViV, 141 with ViR, and 58 with ViMAC). Trans-septal access and the Sapien valves were used in 39.5% and 90.0%, respectively. Overall technical success was excellent at 87.1%. However, left ventricular outflow tract obstruction occurred more frequently after ViMAC compared with ViR and ViV (39.7% vs. 5.0% vs. 2.2%; P < 0.001), whereas second valve implantation was more frequent in ViR compared with ViMAC and ViV (12.1% vs. 5.2% vs. 2.5%; P < 0.001). Accordingly, technical success rate was higher after ViV compared with ViR and ViMAC (94.4% vs. 80.9% vs. 62.1%; P < 0.001). Compared with ViMAC and ViV groups, ViR group had more frequent post-procedural mitral regurgitation ≥moderate (18.4% vs. 13.8% vs. 5.6%; P < 0.001) and subsequent paravalvular leak closure (7.8% vs. 0.0% vs. 2.2%; P = 0.006). All-cause mortality was higher after ViMAC compared with ViR and ViV at 30 days (34.5% vs. 9.9% vs. 6.2%; log-rank P < 0.001) and 1 year (62.8% vs. 30.6% vs. 14.0%; log-rank P < 0.001). On multivariable analysis, patients with failed annuloplasty rings and severe MAC were at increased risk of mortality after TMVR [ViR vs. ViV, hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.27-3.12; P = 0.003; ViMAC vs. ViV, HR 5.29, 95% CI 3.29-8.51; P < 0.001]. Conclusion: The TMVR provided excellent outcomes for patients with degenerated bioprostheses despite high surgical risk. However, ViR and ViMAC were associated with higher rates of adverse events and mid-term mortality compared with ViV.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Calcinose/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Anuloplastia da Valva Mitral/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
9.
Ann Vasc Surg ; 56: 350.e9-350.e13, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30342211

RESUMO

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) with self-expanding endograft is increasingly used as a viable treatment option for adult aortic coarctation (AC). METHODS: We hereby reported a 55-year-old gentleman with late presentation of AC, treated by a novel strategy with thoracic endograft and in situ laser fenestration for left subclavian artery (LSA) revascularization. RESULTS: AC was incidentally discovered during coronary angiogram as an investigation for his angina pectoris. TEVAR with self-expanding endograft was chosen because preoperative computer tomography scan showed ectatic thoracic aorta and stenosis just distal to the LSA. The patient was planned for a timely second-stage aortic valve replacement and coronary artery bypass grafting using left internal mammary artery shortly after TEVAR, which required a patent LSA. The procedure was arranged semiurgently. A 34-mm thoracic tube endograft was placed across the coarctation with proximal landing distal to the left common carotid artery. In situ fenestration was created by laser catheter through retrograde left brachial access. The fenestration was then enlarged by balloon dilatation and bridged to the left subclavian origin with a 16-mm balloon-expandable covered stent. CONCLUSIONS: TEVAR with in situ fenestration for LSA is a reliable choice for adult AC. The technique added to the armamentarium of treatment options.


Assuntos
Angioplastia com Balão/instrumentação , Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Terapia a Laser , Stents , Artéria Subclávia/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 89(1): E44-E52, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27142257

RESUMO

BACKGROUND: Anemia is linked to impaired outcome in patients with cardiovascular diseases. We sought to characterize the impact of baseline anemia on mid-term outcome after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: Data of 1201 consecutive TAVI patients were retrospectively analyzed. Baseline anemia was defined according to the WHO (hemoglobin <12g/dl [female], <13g/dl [male]). It was prevalent in 59.0% of patients and associated with a higher preoperative risk (STS-PROM 7.8 ± 5.7 vs. 6.2 ± 4.1%, P < 0.001). Survival was similar at 30 days (90.5 vs. 91.2%, P = 0.626) but NYHA functional capacity was impaired in patients with baseline anemia (classes III/IV: 20.6 vs. 15.6%, P = 0.006). Low baseline hemoglobin (OR 0.85, CI 0.73-0.98, P = 0.025), blood transfusion (OR 2.42, CI 1.38-4.28, P = 0.002), and bleeding complications (OR 2.21, CI 1.27-3.81, P = 0.005) were in addition associated with acute kidney injury after TAVI. Three-year survival was reduced (49.6 vs. 64.9%, P = 0.002) and baseline anemia was linked to increased mid-term mortality (HR 1.43, CI 1.13-1.82, P = 0.003), however its effect was surpassed by the adverse impact of periprocedural complications. CONCLUSIONS: Baseline anemia was associated with increased morbidity and mortality after TAVI. Preprocedural hemoglobin levels need to be assessed for risk stratification and blood conservation management seems essential. As a potentially modifiable target, the role of pretreatment of anemia prior to TAVI remains to be determined. © 2016 Wiley Periodicals, Inc.


Assuntos
Anemia/complicações , Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Anemia/sangue , Anemia/diagnóstico , Anemia/mortalidade , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Biomarcadores/sangue , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemoglobinas/metabolismo , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 90(7): 1167-1174, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28296065

RESUMO

OBJECTIVES: The aim of this study was to evaluate safety, feasibility, and efficacy of transaxillary TAVI using a novel self-expandable transcatheter heart valve (THV) via a direct percutaneous technique. METHODS: The analysis comprises 12 consecutive patients with severe aortic stenosis treated with the ACURATE Neo™ THV (Symetis) by direct percutaneous transaxillary access. RESULTS: Patients presented with a mean age of 79.9 ± 6.2 years and high calculated surgical risk (logEuroSCORE I: 19.55 ± 15.00%; STS PROM score: 5.42 ± 3.25%). Transaxillary TAVI was performed in 11/12 via the left and in 1/12 via the right-sided axillary artery. Device success was achieved in all patients (12/12). Mortality rate at 30 days was 0% (0/12). No major and one minor access site complication (1/12) occurred. No major or life-threatening access site-related bleeding resulted. None of the patients suffered from postprocedural stroke/transient ischemic attack. There was no need for a permanent pacemaker. Mean effective orifice area post implantation was 2.1 ± 0.29 cm2 and mean aortic gradient 6.2 ± 1.5 mm Hg. In none of the patients, greater than moderate aortic regurgitation or paravalvular leakage was detected at discharge (0/12). CONCLUSIONS: Our study suggests that the implantation of the second-generation self-expandable ACURATE Neo™ via a transaxillary access is technically feasible and safe and yields excellent short-term clinical results. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Artéria Axilar , Cateterismo Periférico/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Artéria Axilar/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Bases de Dados Factuais , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Falha de Prótese , Punções , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
Eur Heart J ; 36(47): 3370-9, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26314688

RESUMO

BACKGROUND: The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. AIM: To compare the efficacy of a Prostar XL- vs. Perclose ProGlide-based vascular closure strategy. METHODS: The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL- (Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. RESULTS: Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). CONCLUSIONS: Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular/efeitos adversos , Doenças Vasculares/etiologia , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Cardiologia/normas , Competência Clínica/normas , Constrição Patológica/etiologia , Feminino , Artéria Femoral , Humanos , Curva de Aprendizado , Masculino , Infarto do Miocárdio/etiologia , Hemorragia Pós-Operatória/etiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação
13.
Catheter Cardiovasc Interv ; 86(7): 1280-6, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26389782

RESUMO

INTRODUCTION: Implantation of transcatheter heart valves (THV) into degenerated surgical valves is an emerging therapy for selected high-risk patients. Although, CE mark of most THV is limited for native aortic valvular stenosis, transcatheter valve implantation into degenerated bioprostheses, even in mitral position is very intriguing. METHODS AND RESULTS: After placement of a cerebral protection device (Claret Sentinel®), three consecutive patients (age, 79.0 ± 6.1; log EuroSCORE I: 33.3 ± 9.2%) with a degenerated mitral bioprosthesis were treated by transapical implantation of the Lotus® valve (Boston Scientific Inc.). In addition, a SwanGanz catheter was introduced in the pulmonary artery for hemodynamic assessments all patients. Procedural success was 100%. Valve implantation was performed without rapid ventricular pacing. Resheating was performed in two patients due to suboptimal initial positioning. Invasive online hemodynamics revealed stable blood pressure in all patients. After Lotus® valve implantation, valvular mitral regurgitation was completely eliminated in all patients. One patient had a mild paravalvular leak of the surgical bioprosthesis, which was present before implantation. Invasive right and left heart hemodynamics showed an immediate improvement after Lotus® valve implantation. Mean mitral surface area (2.1 ± 0.2 cm(2) ) and mean gradient (3.7 ± 2.1 mm Hg) demonstrated satisfactory results. All patients were immediately extubated and discharged from the hospital without any adverse event. CONCLUSIONS: This study demonstrates for the first time the feasibility of transapical Lotus® Valve implantation in degenerated mitral bioprostheses. The controlled mechanical Lotus® valve expansion with remarkably stable hemodynamics throughout the procedure offers a new and valuable treatment option.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo de Swan-Ganz , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Retratamento , Resultado do Tratamento
14.
J Invasive Cardiol ; 2024 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-38935444

RESUMO

Objectives: Atrioventricular (AV) conduction disturbances are still common following transcatheter aortic valve replacement (TAVR). The study evaluates the feasibility and clinical effect of self-expanding (SE)-TAVR employing an optimized cusp-overlay technique (COT) at 1 year in a German all-comers population. Methods: We analyzed 1-year clinical outcomes in patients who received a SE valve employing the optimized COT. Consecutive patients who underwent SE-TAVR (EvolutR, EvolutPRO) after introduction of the COT as the default implantation technique in 2020 were included (n = 101). Consecutive TAVR patients from the same operators using the conventional implantation technique (CIT) served as the control group (n = 116). Results: The COT was successfully performed in more than 80% of the patients in the COT group. (81.2%, n = 82/101). At discharge, no difference regarding AV block of at least II (CIT 19.47% vs COT 21%; P = .86) and permanent pacemaker (PPM) implantation (CIT 17.5% vs COT 19%; P = .73) was observed between the cohorts. New left bundle branch block (LBBB) was significantly less frequent in the COT group (CIT 40.71% vs COT 26%; P = .029). Paravalvular leakage (PVL) greater than I° was reduced in the COT cohort (CIT 8.62% vs COT 0.99%; P = .012). There was no significant difference in mortality (CIT 18.27% vs COT 13.83%; P = .44), stroke (CIT 9.62% vs COT 15.96%; P = .16) or cardiovascular rehospitalization after 1 year (CIT 25.96% vs 24.47%; P = .92) between the groups. Conclusions: Implementation of COT-TAVR was feasible and safe, and it resulted in an improvement of TAVR outcomes regarding PVL greater than I° and new onset LBBB. However, with respect to PPM, no difference was observed 1-year post-TAVR.

15.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37524838

RESUMO

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Resultado do Tratamento
16.
Struct Heart ; 8(4): 100322, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39100583

RESUMO

Background: Transcatheter mitral valve replacement (TMVR) represents a novel treatment option for patients with mitral regurgitation (MR), but little is known about the hemodynamic impact of MR elimination following TMVR. We sought to investigate the hemodynamic impact of TMVR on left ventricular (LV) and right ventricular (RV) function using noninvasive pressure-volume loops. Methods: All consecutive patients undergoing TMVR with dedicated devices between May 2016 and August 2022 were enrolled. The end-diastolic and end-systolic pressure-volume relationships were estimated from 26 patients using single-beat echocardiographic measurements at baseline and after TMVR at discharge. RV function was assessed by RV-pulmonary artery (PA) coupling and RV fractional area change. One-year follow-up was available for 19 patients. The prognostic impact of calculated end-diastolic volume at an end-diastolic pressure of 20 mmHg (VPed20) reduction was assessed by Cox regression. Results: A total of 26 patients (77.0 years [interquartile range 73.9-80.1], N = 17 [65.4%] male) with successful TMVR were included (secondary MR [N = 21, 80.8%]; median LV ejection fraction was 37.0% [interquartile range 30.7-50.7]). At discharge, a decrease in VPed20 (p < 0.001) indicating leftward shift of end-diastolic pressure-volume relationship, and an increase of the end-systolic elastance slope (p = 0.007) were observed after TMVR. No changes were observed for RV-PA coupling (p = 0.19) and RV fractional area change (p = 0.22). At 1-year follow-up, LV contractility (end-systolic elastance) and RV-PA coupling remained stable. Vped20 reduction at discharge was significantly associated with 1-year all-cause mortality or heart failure hospitalization (hazard ratio 0.16, 95% CI 0.04-0.71, p = 0.016). Conclusions: Noninvasive assessment of pressure-volume loops demonstrated early LV reverse remodeling and improved LV contractility, while RV performance was preserved. These results indicate the potential prognostic impact of complete MR elimination after TMVR.

17.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771899

RESUMO

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Ecocardiografia Doppler , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Tomografia Computadorizada Multidetectores/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Estudos Retrospectivos , Idoso , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Calcinose/mortalidade , Ecocardiografia Doppler/métodos , Idoso de 80 Anos ou mais , Prognóstico , Curva ROC , Hemodinâmica , Pessoa de Meia-Idade , Fatores de Risco
18.
Clin Res Cardiol ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466346

RESUMO

BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.

19.
J Clin Med ; 13(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38592323

RESUMO

(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.

20.
JACC Cardiovasc Interv ; 17(13): 1559-1573, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986655

RESUMO

BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Idoso , Resultado do Tratamento , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Risco , Fatores de Tempo , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA