Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Transl Stroke Res ; 11(2): 204-213, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31444692

RESUMO

Peripheral sensory stimulation augments post-stroke upper extremity rehabilitation outcomes. Most sensory stimulations interfere with natural hand tasks and the stimulation duration is limited. We developed TheraBracelet, low-level random-frequency vibration applied via a wristwatch, to enable stimulation during hand tasks and potentially extend stimulation durations. To determine safety of prolonged exposure to TheraBracelet. Single-site double-blind crossover randomized controlled trial. Chronic stroke survivors were instructed to wear a device on the affected wrist for > 8 h/day everyday for 2 months while coming to the laboratory weekly for evaluations, with a 2-week break between each month. The device applied vibration at 60% and 1% of the sensory threshold for the real and sham month, respectively. The order of the real and sham months was randomized/balanced. Adverse events (AEs) were assessed weekly, including worsening of hand sensation, dexterity, grip strength, pain, or spasticity and occurrence of skin irritation or swelling. Device-related AE rates were compared between the real and sham month. Twenty-five participants completed the study. Six participants (24%) experienced mild AEs involving worsened sensory scores that may be related to the intervention with reasonable possibility. Two experienced them in the real stimulation month only, 3 in the sham month only, and 1 in both months. Therefore, less participants experienced device-related AEs in the real than sham month. Daily stimulation using the device for a month is safe for chronic stroke survivors. Future studies examining the efficacy of pairing TheraBracelet with therapy for increasing neurorehabilitation outcomes are a logical next step. Trial registration: NCT03318341.


Assuntos
Reabilitação do Acidente Vascular Cerebral/métodos , Dispositivos Eletrônicos Vestíveis , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Física/instrumentação , Estimulação Física/métodos , Segurança , Reabilitação do Acidente Vascular Cerebral/efeitos adversos , Resultado do Tratamento , Vibração , Dispositivos Eletrônicos Vestíveis/efeitos adversos , Punho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA