Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374848

RESUMO

OBJECTIVES: We report our single-center experience of mid-term to long-term retrieval and reimplantation of a tines-based leadless pacemaker (Micra transcatheter pacing system; TPS). BACKGROUNDS: The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favorable in specific scenarios. METHODS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. RESULTS: After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 minutes, and fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSIONS: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.

2.
J Cardiovasc Electrophysiol ; 27 Suppl 1: S29-37, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26969220

RESUMO

INTRODUCTION: Catheter ablation is an effective treatment of scar-related ventricular tachycardia (VT), but the overall complexity of the procedure has precluded its widespread use. Remote magnetic navigation (RMN) has been shown to facilitate cardiac mapping and ablation of VT in a retrospective series. STOP-VT is the first multicenter, prospective, single-arm and single-procedure study evaluating RMN-based mapping and ablation of post-infarction VT. METHODS: Patients with documented VT and prior MI, in whom an ICD was implanted either for primary or secondary prevention, were recruited from four EU and US centers. Either a transseptal (48 patients) or transaortic (5 patients) approach was employed to gain access for ventricular endocardial mapping/ablation during VT (entrainment mapping, activation mapping) and/or substrate mapping in sinus rhythm (elimination of fractionated/late potentials, variable extent of substrate modification) with RMN and irrigated RF ablation. The primary endpoints were as follows: (i) non-inducibility of the target VT or any other sustained VT; (ii) elimination of sustained VT/VF during ICD follow-up of up to 12 months. RESULTS: The cohort included 53 consecutive patients (median age 67 years, 49 men, median LVEF 31%). One hemodynamically unstable patient was excluded at the onset of mapping. Inducibility of sustained VT was achieved an average of 2.2 times per patient (1-8), with mean tachycardia cycle length (TCL) 374 milliseconds (179-510). Mean total procedure and fluoroscopy times were 223 minutes and 8.7 minutes, respectively; mean cumulative fluoroscopy time during mapping and ablation was 0.95 minutes; maximum power averaged 42.3 W with nominal saline 30 cc/min irrigation; mean cumulative RF time was 38 minutes. Non-inducibility of the target VT was achieved in 49/52 patients (94.2%) and non-inducibility of any VT was achieved in 38/52 patients (73.1%). A combination of RMN and manual ablation was performed in two patients, rendering one non-inducible. During the 12-month ICD follow-up period, freedom from any sustained VT/VF was observed in 30 patients (62%), of which 19 (63%) were off antiarrhythmic medications. Five patients expired during follow-up: one presented with a VT storm, but for the others, death was not related to VT/VF (MI-cardiogenic shock, pulmonary embolism, bronchogenic carcinoma, end stage heart failure). No procedural complications were reported. CONCLUSIONS: This first prospective, single-procedure, multicenter study indicates that remote magnetic navigation is a safe and effective method for catheter ablation of post-infarction VT.


Assuntos
Ablação por Cateter/métodos , Internacionalidade , Fenômenos Magnéticos , Procedimentos Cirúrgicos Robóticos/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Circulation ; 129(14): 1466-71, 2014 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-24664277

RESUMO

BACKGROUND: Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. METHODS AND RESULTS: The primary safety end point was freedom from complications at 90 days. Secondary performance end points included implant success rate, implant time, and measures of device performance (pacing/sensing thresholds and rate-responsive performance). The mean age of the patient cohort (n=33) was 77±8 years, and 67% of the patients were male (n=22/33). The most common indication for cardiac pacing was permanent atrial fibrillation with atrioventricular block (n=22, 67%). The implant success rate was 97% (n=32). Five patients (15%) required the use of >1 leadless cardiac pacemaker during the procedure. One patient developed right ventricular perforation and cardiac tamponade during the implant procedure, and eventually died as the result of a stroke. The overall complication-free rate was 94% (31/33). After 3 months of follow-up, the measures of pacing performance (sensing, impedance, and pacing threshold) either improved or were stable within the accepted range. CONCLUSIONS: In a prospective nonrandomized study, a completely self-contained, single-chamber leadless cardiac pacemaker has shown to be safe and feasible. The absence of a transvenous lead and subcutaneous pulse generator could represent a paradigm shift in cardiac pacing. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT01700244.


Assuntos
Arritmias Cardíacas/terapia , Desenho de Equipamento , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 26(5): 493-500, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25644659

RESUMO

INTRODUCTION: Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS AND RESULTS: PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at ∼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up. CONCLUSIONS: The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , República Tcheca , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Esofagoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados não Aleatórios como Assunto , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Resultado do Tratamento
6.
Europace ; 16(12): 1746-51, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25031237

RESUMO

AIMS: Durable isolation of the pulmonary veins (PVs) remains the cornerstone of treatment for paroxysmal atrial fibrillation (PAF) and is also used in the treatment of some patients with persistent atrial fibrillation. Visually guided laser ablation (VGLA) has been proven to be safe and effective as a treatment for atrial fibrillation (AF). It has shown high levels of durable PV isolation (PVI), even in the hands of less experienced users. This paper presents the long-term clinical outcomes of all patients treated with VGLA over the course of 4 years in the world's most experienced centre: from early product feasibility work treating only PAF patients to our work using the commercially available product, when we also treated persistent AF patients. METHODS AND RESULTS: One hundred and ninety-four patients (63 females, mean age 61 years) with either a history of drug-refractory PAF (time since initial diagnosis: 60.73 months) or persistent AF (time since initial diagnosis: 62.75 months) were treated in our laboratory with VGLA between 7 January 2009 and 17 May 2013. Follow-up of all patients was consistent with our standard clinical practice with a 7-day Holter being performed at the first clinical visit between 4 and 6 months and, for most patients, again at 12 months post-procedure. Twelve lead electrocardiograms were performed at all clinical visits. Recurrence of AF is defined as any documented AF episode >30 s. Acute procedural results show that 692 veins were acutely isolated with a mean procedure and fluoroscopy time of 226 and 20.4 min, respectively. One hundred and seventy (158 PAF and 12 persistent AF) patients reached 1 year of follow-up, 130 (82.3%) patients remained free of AF in the PAF group, and 9 (75%) in the persistent group. Eighty-seven PAF patients have now reached 24 months follow-up and 66 (75.9%) remain free of AF. Fifty-four PAF patients have reached 36 months follow-up with 41 (75.9%) remaining free of AF. Thirty-two PAF patients have reached 48 months follow-up and 24 (75%) remain free of AF. The peri-procedural complications we encountered were phrenic nerve injury in four patients (2.06%), tamponade or pericardial effusion in one patient (0.51%), stroke or transient ischaemic attack in one patient (0.514%), and vascular injury in six patients (3.09%). We experienced no cases of PV stenosis or atrio-oesophageal fistula. CONCLUSION: Our single-centre experience using VGLA over 4 years shows that it can be used safely and effectively in normal clinical practice and gives high levels of acute PVI accompanied by good clinical outcomes, even after long-term follow-up.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/métodos , Endoscopia/métodos , Terapia a Laser/métodos , Complicações Pós-Operatórias/prevenção & controle , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Endoscopia/efeitos adversos , Feminino , Humanos , Terapia a Laser/efeitos adversos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/efeitos adversos , Resultado do Tratamento
7.
J Interv Card Electrophysiol ; 67(1): 53-60, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36805921

RESUMO

BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Terapia a Laser/métodos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
8.
JACC Clin Electrophysiol ; 9(4): 481-493, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36752473

RESUMO

BACKGROUND: During atrial fibrillation ablations using thermal energy, the treatment effect is attributed to not just pulmonary vein isolation (PVI), but also to modulation of the autonomic nervous system by ablation of cardiac ganglionated plexi (GP). OBJECTIVES: This study sought to assess the impact of pulsed field ablation (PFA) on the GP in patients undergoing PVI. METHODS: In the retrospective phase, heart rate was assessed pre- versus post-PVI using PFA, cryoballoon ablation, or radiofrequency ablation. In the prospective phase, a pentaspline PFA catheter was used in a protocol: 1) pre-PFA, high-frequency stimulation (HFS) identified GP sites by vagal effects; 2) PVI was performed assessing for repetitive vagal effects over each set of PF applications; 3) mapping defined PVI extent to identify those GP in the ablation zone; and 4) repeat HFS at GP sites to assess for persistence of vagal effects. RESULTS: Between baseline and 3 months, heart rates in the retrospective radiofrequency ablation (n = 40), cryoballoon (n = 40), and PFA (n = 40) cohorts increased by 8.9 ± 11.4, 11.1 ± 9.4, and -0.1 ± 9.2 beats/min, respectively (P= 0.01 PFA vs radiofrequency ablation; P= 0.01 PFA vs cryoballoon ablation). In the prospective phase, pre-PFA HFS in 20 additional patients identified 65 GP sites. During PFA, vagal effects were noted in 45% of first PF applications, persisting through all applications in 83%. HFS post-PFA reproduced vagal effects in 29 of 38 sites (76%) in low-voltage tissue. CONCLUSIONS: PFA has minimal effect on GP. Unlike with thermal ablation, the mechanism by which PFA treats atrial fibrillation is mediated solely by durable PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Nervo Vago/cirurgia
9.
J Interv Card Electrophysiol ; 64(2): 375-381, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34089431

RESUMO

BACKGROUND AND PURPOSE: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. METHODS: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. RESULTS: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). CONCLUSION: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. TRIAL REGISTRATION: Registered on the site ClinicalTrials.gov January 2016 with identifier: NCT02821351.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento
11.
JACC Clin Electrophysiol ; 7(5): 614-627, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33933412

RESUMO

OBJECTIVES: This study sought to determine whether durable pulmonary vein isolation (PVI) using pulsed field ablation (PFA) translates to freedom from atrial fibrillation recurrence without an increase in adverse events. BACKGROUND: PFA is a nonthermal ablative modality that, in preclinical studies, is able to preferentially ablate myocardial tissue with minimal effect on surrounding tissues. Herein, we present 1-year clinical outcomes of PFA. METHODS: In 3 multicenter studies (IMPULSE [A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation], PEFCAT [A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation], and PEFCAT II [Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation]), paroxysmal atrial fibrillation patients underwent PVI using a basket or flower PFA catheter. Invasive remapping was performed at ∼2 to 3 months, and reconnected PVs were reisolated with PFA or radiofrequency ablation. After a 90-day blanking period, arrhythmia recurrence was assessed over 1-year follow-up. RESULTS: In 121 patients, acute PVI was achieved in 100% of PVs with PFA alone. PV remapping, performed in 110 patients at 93.0 ± 30.1 days, demonstrated durable PVI in 84.8% of PVs (64.5% of patients), and 96.0% of PVs (84.1% of patients) treated with the optimized biphasic energy PFA waveform. Primary adverse events occurred in 2.5% of patients (2 pericardial effusions or tamponade, 1 hematoma); in addition, there was 1 transient ischemic attack. The 1-year Kaplan-Meier estimates for freedom from any atrial arrhythmia for the entire cohort and for the optimized biphasic energy PFA waveform cohort were 78.5 ± 3.8% and 84.5 ± 5.4%, respectively. CONCLUSIONS: PVI with a "single-shot" PFA catheter results in excellent PVI durability and acceptable safety with a low 1-year rate of atrial arrhythmia recurrence. These data mitigate concern that the nonthermal ablative mechanism of PFA might mask undiscovered compromises to clinical success. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation, NCT03700385; A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation, NCT03714178; PEFCAT II Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation [PEFCAT II], NCT04170608).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Humanos , Veias Pulmonares/cirurgia , Recidiva
12.
N Engl J Med ; 357(26): 2657-65, 2007 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-18160685

RESUMO

BACKGROUND: For patients who have a ventricular tachyarrhythmic event, implantable cardioverter-defibrillators (ICDs) are a mainstay of therapy to prevent sudden death. However, ICD shocks are painful, can result in clinical depression, and do not offer complete protection against death from arrhythmia. We designed this randomized trial to examine whether prophylactic radiofrequency catheter ablation of arrhythmogenic ventricular tissue would reduce the incidence of ICD therapy. METHODS: Eligible patients with a history of a myocardial infarction underwent defibrillator implantation for spontaneous ventricular tachycardia or fibrillation. The patients did not receive antiarrhythmic drugs. Patients were randomly assigned to defibrillator implantation alone or defibrillator implantation with adjunctive catheter ablation (64 patients in each group). Ablation was performed with the use of a substrate-based approach in which the myocardial scar is mapped and ablated while the heart remains predominantly in sinus rhythm. The primary end point was survival free from any appropriate ICD therapy. RESULTS: The mortality rate 30 days after ablation was zero, and there were no significant changes in ventricular function or functional class during the mean (+/-SD) follow-up period of 22.5+/-5.5 months. Twenty-one patients assigned to defibrillator implantation alone (33%) and eight patients assigned to defibrillator implantation plus ablation (12%) received appropriate ICD therapy (antitachycardia pacing or shocks) (hazard ratio in the ablation group, 0.35; 95% confidence interval, 0.15 to 0.78, P=0.007). Among these patients, 20 in the control group (31%) and 6 in the ablation group (9%) received shocks (P=0.003). Mortality was not increased in the group assigned to ablation as compared with the control group (9% vs. 17%, P=0.29). CONCLUSIONS: In this randomized trial, prophylactic substrate-based catheter ablation reduced the incidence of ICD therapy in patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death. (Current Controlled Trials number, ISRCTN62488166 [controlled-trials.com].).


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/complicações , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/etiologia
13.
J Int Med Res ; 48(5): 300060520923495, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32420781

RESUMO

His bundle pacing is a relatively new method of cardiac pacing. This method is used in patients with atrioventricular block to prevent heart failure associated with right ventricular pacing, and in patients with bundle branch block and cardiomyopathy. We report a patient with cardiomyopathy and left bundle branch block with failure of cardiac resynchronization therapy. Permanent His bundle pacing was associated with clinical improvement and improvement of parameters of cardiac function.


Assuntos
Fascículo Atrioventricular/fisiologia , Bloqueio de Ramo/cirurgia , Cateterismo Cardíaco/instrumentação , Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Dilatada/cirurgia , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Cateterismo Cardíaco/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia , Eletrodos Implantados , Feminino , Humanos , Marca-Passo Artificial , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
14.
JACC Clin Electrophysiol ; 6(14): 1744-1751, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357570

RESUMO

OBJECTIVES: The authors report their single-center experience with the retrieval and replacement of long-term implanted leadless cardiac pacemakers (LPs) and the factors contributing to success. BACKGROUND: LPs are a clinically effective and safe alternative to standard transvenous pacemakers for single-chamber ventricular pacing. However, the feasibility of retrieving and replacing long-term implanted LPs is not well known. METHODS: A total of 34 patients with implanted Nanostim LPs (mean implantation duration 1,570 ± 479 days) subsequently underwent retrieval. On the basis of fluoroscopic imaging, the cohort was divided into 2 groups: those with remarkable swinging movement (SM) of the LP docking button (n = 25) and those without SM (n = 9). RESULTS: The overall LP retrieval success rate was 85% (n = 29). New leadless devices were implanted in 27 patients immediately after LP retrieval. No procedure-related adverse events occurred. The rate of successful LP retrieval was significantly higher in the SM group (25 of 25 [100%]) than in the no-SM group (4 of 9 [44%]) (p < 0.001), and fluoroscopy time during the retrieval procedure was shorter in the SM group (12.7 ± 8.6 min) than in the no-SM group (45.6 ± 19 min) (p < 0.001). CONCLUSIONS: This study demonstrated the feasibility and safety of retrieval of long-term implanted LPs after a mean duration of 4 years. Retrieval was most successful in patients whose docking buttons exhibited significant SM.


Assuntos
Marca-Passo Artificial , Desenho de Equipamento , Fluoroscopia , Humanos , Marca-Passo Artificial/efeitos adversos , Próteses e Implantes
15.
JACC Case Rep ; 2(14): 2249-2252, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34317150

RESUMO

This is the first report of the management of a patient with cardiac resynchronization therapy using leadless biventricular pacing. Successful retrieval of a 4-year-old Micra transcatheter pacing system (TPS) and reimplantation of a new Micra TPS prevented device-to-device interactions from multiple pacing devices in the right ventricle. (Level of Difficulty: Advanced.).

17.
J Am Coll Cardiol ; 74(3): 315-326, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31085321

RESUMO

BACKGROUND: Catheter ablation of atrial fibrillation using thermal energies such as radiofrequency or cryothermy is associated with indiscriminate tissue destruction. During pulsed field ablation (PFA), subsecond electric fields create microscopic pores in cell membranes-a process called electroporation. Among cell types, cardiomyocytes have among the lowest thresholds to these fields, potentially permitting preferential myocardial ablation. OBJECTIVES: The purpose of these 2 trials was to determine whether PFA allows durable pulmonary vein (PV) isolation without damage to collateral structures. METHODS: Two trials were conducted to assess the safety and effectiveness of catheter-based PFA in paroxysmal atrial fibrillation. Ablation was performed using proprietary bipolar PFA waveforms: either monophasic with general anesthesia and paralytics to minimize muscle contraction, or biphasic with sedation because there was minimal muscular stimulation. No esophageal protection strategy was used. Invasive electrophysiological mapping was repeated after 3 months to assess the durability of PV isolation. RESULTS: In 81 patients, all PVs were acutely isolated by monophasic (n = 15) or biphasic (n = 66) PFA with ≤3 min elapsed delivery/patient, skin-to-skin procedure time of 92.2 ± 27.4 min, and fluoroscopy time of 13.1 ± 7.6 min. With successive waveform refinement, durability at 3 months improved from 18% to 100% of patients with all PVs isolated. Beyond 1 procedure-related pericardial tamponade, there were no additional primary adverse events over the 120-day median follow-up, including: stroke, phrenic nerve injury, PV stenosis, and esophageal injury. The 12-month Kaplan-Meier estimate of freedom from arrhythmia was 87.4 ± 5.6%. CONCLUSIONS: In first-in-human trials, PFA preferentially affected myocardial tissue, allowing facile ultra-rapid PV isolation with excellent durability and chronic safety. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation; NCT03700385; and PEFCAT: A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation; NCT03714178).


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 4(8): 987-995, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30139499

RESUMO

OBJECTIVES: The authors report the first acute clinical experience of atrial fibrillation ablation with PEF-both epicardial box lesions during cardiac surgery, and catheter-based PV isolation. BACKGROUND: Standard energy sources rely on time-dependent conductive heating/cooling and ablate all tissue types indiscriminately. Pulsed electric field (PEF) energy ablates nonthermally by creating nanoscale pores in cell membranes. Potential advantages for atrial fibrillation ablation include: 1) cardiomyocytes have among the lowest sensitivity of any tissue to PEF-allowing tissue selectivity, thereby minimizing ablation of nontarget collateral tissue; 2) PEF is delivered rapidly over a few seconds; and 3) the absence of coagulative necrosis obviates the risk of pulmonary vein (PV) stenosis. METHODS: PEF ablation was performed using a custom over-the-wire endocardial catheter for percutaneous transseptal PV isolation, and a linear catheter for encircling the PVs and posterior left atrium during concomitant cardiac surgery. Endocardial voltage maps were created pre- and post-ablation. Continuous and categorical data are summarized and presented as mean ± SD and frequencies. RESULTS: At 2 centers, 22 patients underwent ablation under general anesthesia: 15 endocardial and 7 epicardial. Catheter PV isolation was successful in all 57 PVs in 15 patients (100%) using 3.26 ± 0.5 lesions/PV: procedure time 67 ± 10.5 min, catheter time (PEF catheter entry to exit) 19 ± 2.5 min, total PEF energy delivery time <60 s/patient, and fluoroscopy time 12 ± 4.0 min. Surgical box lesions were successful in 6 of 7 patients (86%) using 2 lesions/patient. The catheter time for epicardial ablation was 50.7 ± 19.5 min. There were no complications. CONCLUSIONS: These data usher in a new era of tissue-specific, ultrarapid ablation of atrial fibrillation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletroporação/métodos , Idoso , Endocárdio/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Pericárdio/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia
20.
Heart Rhythm ; 15(9): 1387-1393, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29709576

RESUMO

BACKGROUND: The recent introduction of leadless pacemakers (PMs) was aimed to eliminate transvenous lead- and pocket-related complications. While the initial results with the leadless PMs seem promising, the nonrandomized nature, limited implant experience of operators, and short follow-up period of these studies preclude a simple comparison to transvenous PMs. OBJECTIVES: The objective of this study was to provide a balanced comparison of leadless and transvenous single-chamber PM therapies through a propensity score-matched analysis. METHODS: Leadless patients from 3 experienced leadless implant centers were propensity score-matched to VVI-R patients from a contemporary prospective multicenter transvenous PM registry. The primary outcome was device-related complications that required invasive intervention during mid-term follow-up. Separate analyses including and excluding PM advisory-related complications were performed. RESULTS: A total of 635 patients were match-eligible (leadless: n = 254; transvenous: n = 381), of whom 440 patients (median age 78 years; interquartile range 70-84 years; 61% men) were successfully matched (leadless: n = 220 vs transvenous: n = 220). The complication rate at 800 days of follow-up was 0.9% (95% confidence interval [CI] 0%-2.2%) in the leadless group vs 4.7% (95% CI 1.8%-7.6%) in the transvenous group when excluding PM advisory-related complications (P = .02). When including these PM advisory-related complications, the complication rate at 800 days increased to 10.9% (95% CI 4.8%-16.5%) in the leadless group vs 4.7% (95% CI 1.8%-7.6%) in the transvenous group (P = .063). CONCLUSION: This study reveals favorable complication rates for leadless compared to transvenous single-chamber pacing therapy at mid-term follow-up in a propensity score-matched cohort. When including PM advisory-related complications, this advantage is no longer observed.


Assuntos
Arritmias Cardíacas/terapia , Cateterismo Venoso Central/métodos , Marca-Passo Artificial , Pontuação de Propensão , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA