Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Nucleic Acids Res ; 44(2): e10, 2016 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-26358811

RESUMO

In this paper, we asked if it is possible to identify the best primers and reaction conditions based on improvements in reaction speed when optimizing isothermal reactions. We used digital single-molecule, real-time analyses of both speed and efficiency of isothermal amplification reactions, which revealed that improvements in the speed of isothermal amplification reactions did not always correlate with improvements in digital efficiency (the fraction of molecules that amplify) or with analytical sensitivity. However, we observed that the speeds of amplification for single-molecule (in a digital device) and multi-molecule (e.g. in a PCR well plate) formats always correlated for the same conditions. Also, digital efficiency correlated with the analytical sensitivity of the same reaction performed in a multi-molecule format. Our finding was supported experimentally with examples of primer design, the use or exclusion of loop primers in different combinations, and the use of different enzyme mixtures in one-step reverse-transcription loop-mediated amplification (RT-LAMP). Our results show that measuring the digital efficiency of amplification of single-template molecules allows quick, reliable comparisons of the analytical sensitivity of reactions under any two tested conditions, independent of the speeds of the isothermal amplification reactions.


Assuntos
Primers do DNA/química , RNA Viral/química , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Regiões 5' não Traduzidas/genética , Primers do DNA/síntese química , Hepacivirus/química , Hepacivirus/genética , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Sensibilidade e Especificidade , Fatores de Tempo
2.
Angew Chem Int Ed Engl ; 53(31): 8088-8092, 2014 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-24889060

RESUMO

We experimentally monitored, at the single-molecule level, the competition among reverse transcription, exponential amplification (RT-LAMP), and linear degradation (restriction enzymes) starting with hepatitis C viral RNA molecules. We found significant heterogeneity in the rate of single-molecule amplification; introduction of the restriction enzymes affected both the rate and the "fate" (the binary outcome) of single-molecule amplification. While end-point digital measurements were primarily sensitive to changes in fate, the bulk real-time kinetic measurements were dominated by the rate of amplification of the earliest molecules, and were not sensitive to fate of the rest of the molecules. We show how this competition of reactions can be used for rapid HCV genotyping with either digital or bulk readout. This work advances our understanding of single-molecule dynamics in reaction networks and may help bring genotyping capabilities out of clinical labs and into limited-resource settings.


Assuntos
Genótipo , Hepacivirus/genética , RNA Viral/genética
3.
Anal Chem ; 85(22): 11129-36, 2013 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-24199852

RESUMO

Quantitative bioanalytical measurements are commonly performed in a kinetic format and are known to not be robust to perturbation that affects the kinetics itself or the measurement of kinetics. We hypothesized that the same measurements performed in a "digital" (single-molecule) format would show increased robustness to such perturbations. Here, we investigated the robustness of an amplification reaction (reverse-transcription loop-mediated amplification, RT-LAMP) in the context of fluctuations in temperature and time when this reaction is used for quantitative measurements of HIV-1 RNA molecules under limited-resource settings (LRS). The digital format that counts molecules using dRT-LAMP chemistry detected a 2-fold change in concentration of HIV-1 RNA despite a 6 °C temperature variation (p-value = 6.7 × 10(-7)), whereas the traditional kinetic (real-time) format did not (p-value = 0.25). Digital analysis was also robust to a 20 min change in reaction time, to poor imaging conditions obtained with a consumer cell-phone camera, and to automated cloud-based processing of these images (R(2) = 0.9997 vs true counts over a 100-fold dynamic range). Fluorescent output of multiplexed PCR amplification could also be imaged with the cell phone camera using flash as the excitation source. Many nonlinear amplification schemes based on organic, inorganic, and biochemical reactions have been developed, but their robustness is not well understood. This work implies that these chemistries may be significantly more robust in the digital, rather than kinetic, format. It also calls for theoretical studies to predict robustness of these chemistries and, more generally, to design robust reaction architectures. The SlipChip that we used here and other digital microfluidic technologies already exist to enable testing of these predictions. Such work may lead to identification or creation of robust amplification chemistries that enable rapid and precise quantitative molecular measurements under LRS. Furthermore, it may provide more general principles describing robustness of chemical and biological networks in digital formats.


Assuntos
Telefone Celular , HIV-1/genética , Microfluídica/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , HIV-1/isolamento & purificação , Humanos , Cinética , RNA Viral/genética , Temperatura
4.
Rapid Commun Mass Spectrom ; 26(1): 78-82, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22271471

RESUMO

A low-cost mass spectrometer attachment for thermogravimetric analysis has been constructed from readily available commercial instruments and components. The benefits of this set-up include excellent mass-flow repeatability, simple design, and significantly lower adoption cost as opposed to ready-built commercial solutions. The inclusion of an open source software package allows semi-automated, highly simplified data analysis. The results from the instrument show excellent sensitivity for small volumes of evolved gas, as well as highly reproducible signal strengths. The GUI-based software package provides data analysis in a way that is very intuitive and that can be easily modified to work with a broad range of TG instruments.

5.
Nat Biotechnol ; 40(1): 64-73, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34426703

RESUMO

Although three-dimensional (3D) genome organization is central to many aspects of nuclear function, it has been difficult to measure at the single-cell level. To address this, we developed 'single-cell split-pool recognition of interactions by tag extension' (scSPRITE). scSPRITE uses split-and-pool barcoding to tag DNA fragments in the same nucleus and their 3D spatial arrangement. Because scSPRITE measures multiway DNA contacts, it generates higher-resolution maps within an individual cell than can be achieved by proximity ligation. We applied scSPRITE to thousands of mouse embryonic stem cells and detected known genome structures, including chromosome territories, active and inactive compartments, and topologically associating domains (TADs) as well as long-range inter-chromosomal structures organized around various nuclear bodies. We observe that these structures exhibit different levels of heterogeneity across the population, with TADs representing dynamic units of genome organization across cells. We expect that scSPRITE will be a critical tool for studying genome structure within heterogeneous populations.


Assuntos
Núcleo Celular , Genoma , Animais , Núcleo Celular/genética , Cromatina , DNA/genética , Genoma/genética , Camundongos , Células-Tronco Embrionárias Murinas
6.
Lab Chip ; 19(19): 3200-3211, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31441477

RESUMO

We have developed a multistep microfluidic device that expands the current SlipChip capabilities by enabling multiple steps of droplet merging and multiplexing. Harnessing the interfacial energy between carrier and sample phases, this manually operated device accurately meters nanoliter volumes of reagents and transfers them into on-device reaction wells. Judiciously shaped microfeatures and surface-energy traps merge droplets in a parallel fashion. Wells can be tuned for different volumetric capacities and reagent types, including for pre-spotted reagents that allow for unique identification of original well contents even after their contents are pooled. We demonstrate the functionality of the multistep SlipChip by performing RNA transcript barcoding on-device for synthetic spiked-in standards and for biologically derived samples. This technology is a good candidate for a wide range of biological applications that require multiplexing of multistep reactions in nanoliter volumes, including single-cell analyses.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Nanotecnologia , Análise de Célula Única , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Nanotecnologia/instrumentação , RNA/genética
7.
PLoS One ; 11(10): e0163060, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27760148

RESUMO

Nucleic acid amplification tests that are coupled with a digital readout enable the absolute quantification of single molecules, even at ultralow concentrations. Digital methods are robust, versatile and compatible with many amplification chemistries including isothermal amplification, making them particularly invaluable to assays that require sensitive detection, such as the quantification of viral load in occult infections or detection of sparse amounts of DNA from forensic samples. A number of microfluidic platforms are being developed for carrying out digital amplification. However, the mechanistic investigation and optimization of digital assays has been limited by the lack of real-time kinetic information about which factors affect the digital efficiency and analytical sensitivity of a reaction. Commercially available instruments that are capable of tracking digital reactions in real-time are restricted to only a small number of device types and sample-preparation strategies. Thus, most researchers who wish to develop, study, or optimize digital assays rely on the rate of the amplification reaction when performed in a bulk experiment, which is now recognized as an unreliable predictor of digital efficiency. To expand our ability to study how digital reactions proceed in real-time and enable us to optimize both the digital efficiency and analytical sensitivity of digital assays, we built a custom large-format digital real-time amplification instrument that can accommodate a wide variety of devices, amplification chemistries and sample-handling conditions. Herein, we validate this instrument, we provide detailed schematics that will enable others to build their own custom instruments, and we include a complete custom software suite to collect and analyze the data retrieved from the instrument. We believe assay optimizations enabled by this instrument will improve the current limits of nucleic acid detection and quantification, improving our fundamental understanding of single-molecule reactions and providing advancements in practical applications such as medical diagnostics, forensics and environmental sampling.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Desenho de Equipamento , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Software , Temperatura , Fatores de Tempo
8.
ACS Nano ; 10(3): 3102-13, 2016 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-26900709

RESUMO

Digital single-molecule technologies are expanding diagnostic capabilities, enabling the ultrasensitive quantification of targets, such as viral load in HIV and hepatitis C infections, by directly counting single molecules. Replacing fluorescent readout with a robust visual readout that can be captured by any unmodified cell phone camera will facilitate the global distribution of diagnostic tests, including in limited-resource settings where the need is greatest. This paper describes a methodology for developing a visual readout system for digital single-molecule amplification of RNA and DNA by (i) selecting colorimetric amplification-indicator dyes that are compatible with the spectral sensitivity of standard mobile phones, and (ii) identifying an optimal ratiometric image-process for a selected dye to achieve a readout that is robust to lighting conditions and camera hardware and provides unambiguous quantitative results, even for colorblind users. We also include an analysis of the limitations of this methodology, and provide a microfluidic approach that can be applied to expand dynamic range and improve reaction performance, allowing ultrasensitive, quantitative measurements at volumes as low as 5 nL. We validate this methodology using SlipChip-based digital single-molecule isothermal amplification with λDNA as a model and hepatitis C viral RNA as a clinically relevant target. The innovative combination of isothermal amplification chemistry in the presence of a judiciously chosen indicator dye and ratiometric image processing with SlipChip technology allowed the sequence-specific visual readout of single nucleic acid molecules in nanoliter volumes with an unmodified cell phone camera. When paired with devices that integrate sample preparation and nucleic acid amplification, this hardware-agnostic approach will increase the affordability and the distribution of quantitative diagnostic and environmental tests.


Assuntos
Telefone Celular , DNA/análise , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , RNA/análise , Bacteriófago lambda/isolamento & purificação , Colorimetria/instrumentação , Corantes/análise , DNA Viral/análise , Desenho de Equipamento , Hepacivirus/isolamento & purificação , Hepatite C/virologia , Humanos , RNA Viral/análise , Tamanho da Amostra
9.
Lab Chip ; 14(24): 4616-28, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25231706

RESUMO

Equipment-free pumping is a challenging problem and an active area of research in microfluidics, with applications for both laboratory and limited-resource settings. This paper describes the pumping lid method, a strategy to achieve equipment-free pumping by controlled generation of pressure. Pressure was generated using portable, lightweight, and disposable parts that can be integrated with existing microfluidic devices to simplify workflow and eliminate the need for pumping equipment. The development of this method was enabled by multi-material 3D printing, which allows fast prototyping, including composite parts that combine materials with different mechanical properties (e.g. both rigid and elastic materials in the same part). The first type of pumping lid we describe was used to produce predictable positive or negative pressures via controlled compression or expansion of gases. A model was developed to describe the pressures and flow rates generated with this approach and it was validated experimentally. Pressures were pre-programmed by the geometry of the parts and could be tuned further even while the experiment was in progress. Using multiple lids or a composite lid with different inlets enabled several solutions to be pumped independently in a single device. The second type of pumping lid, which relied on vapor-liquid equilibrium to generate pressure, was designed, modeled, and experimentally characterized. The pumping lid method was validated by controlling flow in different types of microfluidic applications, including the production of droplets, control of laminar flow profiles, and loading of SlipChip devices. We believe that applying the pumping lid methodology to existing microfluidic devices will enhance their use as portable diagnostic tools in limited resource settings as well as accelerate adoption of microfluidics in laboratories.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Impressão Tridimensional , Técnicas Analíticas Microfluídicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA