Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Endovasc Ther ; 20(6): 770-81, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24325693

RESUMO

PURPOSE: To evaluate the safety and effectiveness of the optical coherence tomography-guided Ocelot catheter to cross femoropopliteal chronic total occlusions (CTOs). METHODS: The CONNECT II study was a prospective, multicenter, non-randomized single-arm study of the safety and effectiveness of the Ocelot catheter in CTO crossing. Key inclusion criteria were a 99% to 100% stenosed femoropopliteal segment, lesion length between 1 and 30 cm, and resistance to guidewire crossing. The main exclusion criterion was a severely calcified target vessel. The primary safety endpoint was 30-day major adverse events (MAE), while the primary effectiveness endpoint was successful CTO crossing (i.e., guidewire placement in the distal true lumen) with the Ocelot catheter. Endpoint analysis was based on pre-specified objective performance criteria. Between February and June 2012, 100 patients (55 men; mean age 69 years) were enrolled. Most of the CTOs (94%) were in the superficial femoral artery (SFA); mean lesion length was 16.6±9.3 cm. RESULTS: Through 30 days, 2 patients experienced MAE (significant perforations) related to the Ocelot catheter. The Ocelot catheter successfully crossed 97% of target CTOs either alone (72%), in conjunction with an assist device (18%), or in conjunction with a re-entry device (7%). Both primary safety and effectiveness endpoints were met. CONCLUSION: The Ocelot catheter with optical coherence tomography guidance offers physicians a reliable option for crossing femoral and popliteal chronic total occlusions with low MAE rates.


Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Doença Crônica , Competência Clínica , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Estados Unidos
2.
JACC Cardiovasc Interv ; 9(13): 1338-46, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27388820

RESUMO

OBJECTIVES: The aim of this study was to prospectively study and confirm the safety and efficacy of the Tryton Side Branch Stent in the treatment of coronary artery bifurcations involving large side branches (SBs). BACKGROUND: The TRYTON Pivotal randomized controlled trial (RCT) was designed to compare the Tryton stent with standard provisional SB stenting in large vessels. The trial inadvertently enrolled patients with too small SBs (<2.25 mm). The overall trial did not meet its primary endpoint, because of an increased rate of periprocedural myocardial infarction in the Tryton stent arm. A post hoc analysis restricted to the intended population showed that the trial would have met its endpoint if only patients with SBs ≥2.25 mm in diameter (by core laboratory quantitative coronary angiography) had been enrolled. METHODS: The Tryton Confirmatory Study was a prospective, single-arm extension of the TRYTON Pivotal RCT that enrolled an additional 133 patients treated with the Tryton Side Branch Stent. It was designed to confirm the results of the post hoc analysis and emphasized the inclusion of appropriately sized SBs. The primary endpoint was noninferiority with regard to periprocedural myocardial infarction (creatine kinase myocardial band 3 times the upper limit of normal) compared with a performance goal based on the TRYTON Pivotal RCT. RESULTS: Among the 133 enrolled patients, 132 (99.2%) had SBs ≥2.25 mm. Baseline clinical and angiographic parameters were similar in this study and the RCT. Periprocedural myocardial infarction occurred in 10.5% of patients, which was numerically lower than the provisional group in the TRYTON Pivotal RCT (11.9%). The 95% confidence bounds did not extend beyond the pre-defined performance goal of 17.9%, meeting the noninferiority primary endpoint. CONCLUSIONS: The Tryton Confirmatory Study, in conjunction with the post hoc analysis of the intended population in the TRYTON Pivotal RCT, supports the safety and efficacy of the Tryton Side Branch Stent for treatment of bifurcation lesions involving large SBs.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Vasos Coronários , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Biomarcadores/sangue , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Creatina Quinase Forma MB/sangue , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
3.
EuroIntervention ; 9(7): 854-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23838387

RESUMO

AIMS: The aim of the study was to determine the safety, efficacy and feasibility of a new chronic total occlusion (CTO) device using optical coherence tomography (OCT) technology, the Ocelot catheter (Avinger, Inc., Redwood City, CA, USA), for crossing of SFA CTOs following guidewire failure. METHODS AND RESULTS: Prospective, multicentre, market preference testing. Thirty-three patients with confirmed CTO (99-100% stenosis by visual estimate) of their superficial femoral artery (SFA) were treated between September 28, 2011, and December 9, 2011, at three European centres. Ocelot crossed 94% (31/33) of CTOs, allowing guidewire placement in the distal true lumen. All (100%) lesions were treated without any major adverse safety events. Procedural time and contrast dose were significantly reduced (p<0.0001) when compared with a similar, non-OCT-guided CTO crossing device (Wildcat catheter; Avinger, Inc.). Overall physician feedback on the catheter performance was positive with an 87% average rating of excellent or good across seven categories. Performance ratings of Ocelot's OCT imaging guidance were consistently positive with an 86% average rating of excellent or good across five OCT categories. CONCLUSIONS: The Ocelot catheter combines advanced CTO crossing technology with real-time OCT guidance. When compared with a similar non-OCT-guided catheter, crossing efficacy and safety profile improved. Total procedure time and contrast volumes were significantly reduced. The Ocelot is a safe, efficient and effective tool for crossing CTOs.


Assuntos
Desenho de Equipamento , Resultado do Tratamento , Animais , Doença Crônica , Felidae , Artéria Femoral/diagnóstico por imagem , Humanos , Estudos Prospectivos , Radiografia
6.
Catheter Cardiovasc Interv ; 58(2): 194-8, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12552543

RESUMO

This study describes a new approach to crossing coronary chronic total occlusions using controlled blunt microdissection and its successful application to coronary angioplasty in three patients. After guidewire techniques failed to cross the occlusions, the blunt intraluminal microdissection catheter was deployed. Actuation of a hinged jaw on the catheter distal assembly created a channel for the guidewire through the diseased segment, in the true lumen (a right coronary and a left circumflex artery) and subintimally (a circumflex artery), to allow angioplasty and stenting. Coronary circulation improved from TIMI grade 0 to 3. Angina was relieved in all three cases. Subsequent angiography for two cases, 2 and 19 months after PTCA, respectively, showed restored flow and patent stented regions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Doença das Coronárias/terapia , Doença Crônica , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Dissecação/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA