RESUMO
Patients with cirrhosis have abnormal coagulation indices such as a high international normalized ratio and low platelet count, but these do not correlate well with periprocedural bleeding risk. We sought to develop a consensus among the multiple stakeholders in cirrhosis care to inform process measures that can help improve the quality of the periprocedural management of coagulopathy in cirrhosis. We identified candidate process measures for periprocedural coagulopathy management in multiple contexts relating to the performance of paracentesis and upper endoscopy. An 11-member panel with content expertise was convened. It included nominees from professional societies for interventional radiology, transfusion medicine, and anesthesia as well as representatives from hematology, emergency medicine, transplant surgery, and community practice. Each measure was evaluated for agreement using a modified Delphi approach (3 rounds of rating) to define the final set of measures. Out of 286 possible measures, 33 measures made the final set. International normalized ratio testing was not required for diagnostic or therapeutic paracentesis as well as diagnostic endoscopy. Plasma transfusion should be avoided for all paracenteses and diagnostic endoscopy. No consensus was achieved for these items in therapeutic intent or emergent endoscopy. The risks of prophylactic platelet transfusions exceed their benefits for outpatient diagnostic paracentesis and diagnostic endosopies. For the other procedures examined, the risks outweigh benefits when platelet count is >20,000/mm 3 . It is uncertain whether risks outweigh benefits below 20,000/mm 3 in other contexts. No consensus was achieved on whether it was permissible to continue or stop systemic anticoagulation. Continuous aspirin was permissible for each procedure. Clopidogrel was permissible for diagnostic and therapeutic paracentesis and diagnostic endoscopy. We found many areas of consensus that may serve as a foundation for a common set of practice metrics for the periprocedural management of coagulopathy in cirrhosis.
Assuntos
Transtornos da Coagulação Sanguínea , Técnica Delphi , Cirrose Hepática , Paracentese , Humanos , Paracentese/métodos , Cirrose Hepática/complicações , Transtornos da Coagulação Sanguínea/etiologia , Transtornos da Coagulação Sanguínea/diagnóstico , Consenso , Coeficiente Internacional NormatizadoRESUMO
PURPOSE: To characterize the response and survival outcomes of yttrium-90 (90Y) transarterial radioembolization (TARE) for unresectable, liver-dominant metastases from primary neoplasms other than colorectal carcinoma. MATERIALS AND METHODS: This study included 1,474 patients enrolled in the Radiation-Emitting Society of Interventional Radiology (SIR)-Spheres in Nonresectable Liver Tumor registry who received resin 90Y-TARE as part of their oncologic management for unresectable primary or secondary liver tumors (NCT02685631). Of these patients, 33% (481/1,474) were treated for liver metastases of noncolorectal origin (m-non-CRC) compared with 34% (497/1,474) treated for metastatic colorectal cancer (mCRC) and 34% (496/1,474) treated for hepatocellular carcinoma. Treatment response and cancer survival probabilities were computed and compared for each primary cancer type. The Kaplan-Meier method and log-rank test were used to compare survival outcomes. RESULTS: Radiological responses were observed in 12 unique cancer types, mostly heavily pretreated malignancies refractory to multiple lines of systemic therapies. The overall use of resin 90Y-TARE in m-non-CRC resulted in better treatment outcomes in terms of duration of response, progression-free survival, time to progression, and overall survival (P = .04, P = .02, P = .01, and P = .04, respectively). Analyses of cancer cell types revealed that metastatic neuroendocrine tumor, sarcoma, and ovarian, renal, prostate, and breast cancers were associated with superior treatment outcomes, whereas worse treatment outcomes were observed in metastatic lung, gastric, pancreatic, and esophageal cancers. CONCLUSIONS: Real-world data demonstrate the use of resin 90Y-TARE in m-non-CRC refractory to standard chemotherapy. For some cell types, this expanded use achieved superior treatment outcomes relative to the reference standard of mCRC, suggesting the need for inquiry into broadened indications for 90Y-TARE.
Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Compostos Radiofarmacêuticos , Sistema de Registros , Radioisótopos de Ítrio , Humanos , Radioisótopos de Ítrio/administração & dosagem , Masculino , Feminino , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/efeitos adversos , Fatores de Tempo , Intervalo Livre de Progressão , Resultado do Tratamento , Adulto , Estados Unidos , Neoplasias/patologia , Neoplasias/radioterapia , Neoplasias/mortalidade , Idoso de 80 Anos ou mais , Fatores de RiscoRESUMO
Quality improvement (QI) initiatives have benefited patients as well as the broader practice of medicine. Large-scale QI has been facilitated by multi-institutional data registries, many of which were formed out of national or international medical society initiatives. With broad participation, QI registries have provided benefits that include but are not limited to establishing treatment guidelines, facilitating research related to uncommon procedures and conditions, and demonstrating the fiscal and clinical value of procedures for both medical providers and health systems. Because of the benefits offered by these databases, Society of Interventional Radiology (SIR) and SIR Foundation have committed to the development of an interventional radiology (IR) clinical data registry known as VIRTEX. A large IR database with participation from a multitude of practice environments has the potential to have a significant positive impact on the specialty through data-driven advances in patient safety and outcomes, clinical research, and reimbursement. This article reviews the current landscape of societal QI programs, presents a vision for a large-scale IR clinical data registry supported by SIR, and discusses the anticipated results that such a framework can produce.
Assuntos
Melhoria de Qualidade , Radiologia Intervencionista , Humanos , Sistema de Registros , Sociedades Médicas , Bases de Dados FactuaisRESUMO
PURPOSE: To assess the use of opioid analgesics and/or antiemetic drugs for pain and nausea following selective chemoembolization with doxorubicin-based conventional (c)-transarterial chemoembolization versus drug-eluting embolic (DEE)-transarterial chemoembolization for hepatocellular carcinoma (HCC). MATERIALS AND METHODS: From October 2014 to 2016, 283 patients underwent 393 selective chemoembolization procedures including 188 patients (48%) who underwent c-transarterial chemoembolization and 205 (52%) who underwent DEE-transarterial chemoembolization. Medical records for all patients were retrospectively reviewed. Administration of postprocedural opioid and/or antiemetic agents were collated. Time of administration was stratified as phase 1 recovery (0-6 hours) and observation (6-24 hours). Logistic regression model was used to investigate the relationship of transarterial chemoembolization type and use of intravenous and/or oral analgesic and antiemetic medications while controlling for other clinical variables. RESULTS: More patients treated with DEE-transarterial chemoembolization required intravenous analgesia in the observation (6-24 hours) phase (18.5%) than those treated with c-transarterial chemoembolization (10.6%; P = .033). Similar results were noted for oral analgesic agents (50.2% vs. 31.4%, respectively; P < .001) and antiemetics (17.1% vs. 7.5%, respectively; P = .006) during the observation period. Multivariate regression models identified DEE-transarterial chemoembolization as an independent predictor for oral analgesia (odds ratio [OR], 1.84; P = .011), for intravenous and oral analgesia in opioid-naïve patients (OR, 2.46; P = .029) and for antiemetics (OR, 2.56; P = .011). CONCLUSIONS: Compared to c-transarterial chemoembolization, DEE-transarterial chemoembolization required greater amounts of opioid analgesic and antiemetic agents 6-24 hours after the procedure. Surgical data indicate that a persistent opioid habit can develop even after minor surgeries, therefore, caution should be exercised, and a regimen of nonopiate pain medications should be considered to reduce postprocedural pain after transarterial chemoembolization.
Assuntos
Analgésicos Opioides/administração & dosagem , Carcinoma Hepatocelular/tratamento farmacológico , Quimioembolização Terapêutica , Neoplasias Hepáticas/tratamento farmacológico , Dor/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/efeitos adversos , Antieméticos/administração & dosagem , Antieméticos/efeitos adversos , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Náusea/induzido quimicamente , Náusea/prevenção & controle , Dor/diagnóstico , Dor/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Vômito/induzido quimicamente , Vômito/prevenção & controleRESUMO
PURPOSE: To generate 3-dimensional (3D) printed ultrasound (US)-compatible vascular models (3DPVAM) and test them for noninferiority in training medical students in femoral artery access. MATERIALS AND METHODS: A 3DPVAM of normal femoral artery (FA) anatomy was developed from an anonymized computerized tomography (CT) examination. Students were randomized to a 3DPVAM or a commercial model (CM) simulation experience (SE) for US-guided FA access. Students completed a pre-SE questionnaire ranking their self-confidence in accessing the artery on a 5-point Likert scale. A standardized SE was administered by interventional radiology faculty or trainees. Students completed a post-SE questionnaire ranking comfort with FA access on a Likert scale. Student questionnaire results from the 3DPVAM group were compared with those from the CM group by using chi-square, Wilcoxon signed-rank, and noninferiority analyses. RESULTS: Twenty-six and twenty-three students were randomized to 3DPVAM and commercial model training, respectively. A total of 76.9% of 3DPVAM trainees and 82.6% of CM trainees did not feel confident performing FA access prior to the SE. In both groups, training increased student confidence by 2 Likert points (3DPVAM: P < 0.001; CM P < 0.001). The confidence increase in 3DPVAM trainees was noninferior to that in CM trainees (P < 0.001). CONCLUSIONS: Generation of a custom-made 3DPVAM is feasible, producing comparable subjective training outcomes to those of CM. Custom-made 3D-printed training models, including incorporation of more complex anatomical configurations, could be used to instruct medical students in procedural skills.
Assuntos
Cateterismo Periférico/métodos , Educação de Graduação em Medicina/métodos , Artéria Femoral/diagnóstico por imagem , Modelos Anatômicos , Modelos Cardiovasculares , Impressão Tridimensional , Radiografia Intervencionista/métodos , Radiologia Intervencionista/educação , Estudantes de Medicina , Competência Clínica , Angiografia por Tomografia Computadorizada , Currículo , Humanos , PunçõesRESUMO
PURPOSE: To assess adoption and survey-based satisfaction rates following deployment of standardized interventional radiology (IR) procedure reports across multiple institutions. MATERIALS AND METHODS: Standardized reporting templates for 5 common interventional procedures (central venous access, inferior vena cava [IVC] filter insertion, IVC filter removal, uterine artery embolization, and vertebral augmentation) were distributed to 20 IR practices in a prospective quality-improvement study. Participating sites edited the reports according to institutional preferences and deployed them for a 1-year pilot study concluding in July 2015. Study compliance was measured by sampling 20 reports of each procedure type at each institution, and surveys of interventionalists and referring physicians were performed. Modifications to the standardized reporting templates at each site were analyzed. RESULTS: Ten institutions deployed the standardized reports, with 8 achieving deployment of 3-12 months. The mean report usage rate was 57%. Each site modified the original reports, with 26% mean reduction in length, 18% mean reduction in wordiness, and 60% mean reduction in the number of forced fill-in fields requiring user input. Linear-regression analysis revealed that reduced number of forced fill-in fields correlated significantly with increased usage rate (R2 = 0.444; P = .05). Surveys revealed high satisfaction rates among referring physicians but lower satisfaction rates among interventional radiologists. CONCLUSIONS: Standardized report adoption rates increased when reports were simplified by reducing the number of forced fill-in fields. Referring physicians preferred the standardized reports, whereas interventional radiologists preferred standard narrative reports.
Assuntos
Documentação/normas , Controle de Formulários e Registros/normas , Prontuários Médicos/normas , Padrões de Prática Médica/normas , Radiografia Intervencionista/normas , Cateterismo Venoso Central/normas , Remoção de Dispositivo/normas , Documentação/métodos , Feminino , Fidelidade a Diretrizes/normas , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Projetos Piloto , Guias de Prática Clínica como Assunto/normas , Estudos Prospectivos , Implantação de Prótese/instrumentação , Implantação de Prótese/normas , Melhoria de Qualidade/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Radiografia Intervencionista/métodos , Estados Unidos , Embolização da Artéria Uterina/normas , Filtros de Veia Cava , Vertebroplastia/normasRESUMO
PURPOSE: To review the safety of hepatic radioembolization (RE) in patients with high (≥ 10%) hepatopulmonary shunt fraction (HPSF) using various prophylactic techniques. MATERIALS AND METHODS: A review was conducted of 409 patients who underwent technetium 99m-labeled macroaggregated albumin scintigraphy before planned RE. Estimated pulmonary absorbed radiation doses based on scintigraphy and hepatic administered activity were calculated. Outcomes from dose reductions and adjunctive catheter-based prophylactic techniques used to reduce lung exposure were assessed. RESULTS: There were 80 patients with HPSF ≥ 10% who received RE treatment (41 resin microspheres for metastases, 39 glass microspheres for hepatocellular carcinoma). Resin microspheres were used in 17 patients according to consensus guideline-recommended dose reduction; 38 patients received no dose reduction because the expected lung dose was < 30 Gy. Prophylactic techniques were used in 25 patients (with expected lung dose ≤ 74 Gy), including hepatic vein balloon occlusion, variceal embolization, or bland arterial embolization before, during, or after RE delivery. Repeated scintigraphy after prophylactic techniques to reduce HPSF in seven patients demonstrated a median change of -40% (range, +32 to -69%). Delayed pneumonitis developed in two patients, possibly related to radiation recall after chemoembolization. Response was lower in patients treated with resin spheres with dose reduction, with an objective response rate of 13% and disease control rate of 47% compared with 56% and 94%, respectively, without dose reduction (P = .023, P = .006). CONCLUSIONS: Dose reduction recommendations for HPSF may compromise efficacy. Excessive shunting can be reduced by prophylactic catheter-based techniques, which may improve the safety of performing RE in patients with high HPSF.
Assuntos
Síndrome Hepatopulmonar/epidemiologia , Síndrome Hepatopulmonar/prevenção & controle , Neoplasias Hepáticas/epidemiologia , Neoplasias Hepáticas/prevenção & controle , Lesões por Radiação/epidemiologia , Lesões por Radiação/prevenção & controle , California/epidemiologia , Comorbidade , Extravasamento de Materiais Terapêuticos e Diagnósticos/epidemiologia , Extravasamento de Materiais Terapêuticos e Diagnósticos/prevenção & controle , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/uso terapêuticoRESUMO
Cutaneous complications can result from nontarget deposition during transcatheter arterial chemoembolization or radioembolization. Liver tumors may receive blood supply from parasitized extrahepatic arteries (EHAs) that also perfuse skin or from hepatic arteries located near the origin of the falciform artery (FA), which perfuses the anterior abdominal wall. To vasoconstrict cutaneous vasculature and prevent nontarget deposition, ice packs were topically applied to at-risk skin in nine chemoembolization treatments performed via 14 parasitized EHAs, seven chemoembolization treatments near the FA origin, and five radioembolization treatments in cases in which the FA could not be prophylactically coil-embolized. No postprocedural cutaneous complications were encountered.
Assuntos
Quimioembolização Terapêutica/efeitos adversos , Crioterapia/métodos , Embolização Terapêutica/efeitos adversos , Gelo , Neoplasias Hepáticas/terapia , Dermatopatias/prevenção & controle , Pele , Vasoconstrição , Adulto , Idoso , Embolização Terapêutica/métodos , Feminino , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiodermite/etiologia , Radiodermite/fisiopatologia , Radiodermite/prevenção & controle , Radioterapia/efeitos adversos , Estudos Retrospectivos , Pele/irrigação sanguínea , Pele/efeitos dos fármacos , Pele/efeitos da radiação , Dermatopatias/diagnóstico por imagem , Dermatopatias/etiologia , Dermatopatias/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
Purpose: We aim to evaluate the performance of radiomic biopsy (RB), best-fit bounding box (BB), and a deep-learning-based segmentation method called no-new-U-Net (nnU-Net), compared to the standard full manual (FM) segmentation method for predicting benign and malignant lung nodules using a computed tomography (CT) radiomic machine learning model. Materials and Methods: A total of 188 CT scans of lung nodules from 2 institutions were used for our study. One radiologist identified and delineated all 188 lung nodules, whereas a second radiologist segmented a subset (n=20) of these nodules. Both radiologists employed FM and RB segmentation methods. BB segmentations were generated computationally from the FM segmentations. The nnU-Net, a deep-learning-based segmentation method, performed automatic nodule detection and segmentation. The time radiologists took to perform segmentations was recorded. Radiomic features were extracted from each segmentation method, and models to predict benign and malignant lung nodules were developed. The Kruskal-Wallis and DeLong tests were used to compare segmentation times and areas under the curve (AUC), respectively. Results: For the delineation of the FM, RB, and BB segmentations, the two radiologists required a median time (IQR) of 113 (54 to 251.5), 21 (9.25 to 38), and 16 (12 to 64.25) s, respectively (p=0.04). In dataset 1, the mean AUC (95% CI) of the FM, RB, BB, and nnU-Net model were 0.964 (0.96 to 0.968), 0.985 (0.983 to 0.987), 0.961 (0.956 to 0.965), and 0.878 (0.869 to 0.888). In dataset 2, the mean AUC (95% CI) of the FM, RB, BB, and nnU-Net model were 0.717 (0.705 to 0.729), 0.919 (0.913 to 0.924), 0.699 (0.687 to 0.711), and 0.644 (0.632 to 0.657). Conclusion: Radiomic biopsy-based models outperformed FM and BB models in prediction of benign and malignant lung nodules in two independent datasets while deep-learning segmentation-based models performed similarly to FM and BB. RB could be a more efficient segmentation method, but further validation is needed.
RESUMO
Purpose To determine the variance and correlation with tumor viability of fluorine 18 (18F) fluoromisonidazole (FMISO) uptake in hepatocellular carcinoma (HCC) prior to and after embolization treatment. Materials and Methods In this single-arm, single-center, prospective pilot study between September 2016 and March 2017, participants with at least one tumor measuring 1.5 cm or larger with imaging or histologic findings diagnostic for HCC were enrolled (five men; mean age, 68 years; age range, 61-76 years). Participants underwent 18F-FMISO PET/CT before and after bland embolization of HCC. A tumor-to-liver ratio (TLR) was calculated by using standardized uptake values of tumor and liver. The difference in mean TLR before and after treatment was compared by using a Wilcoxon rank sum test, and correlation between TLR and tumor viability was assessed by using the Spearman rank correlation coefficient. Results Four participants with five tumors were included in the final analysis. The median tumor diameter was 3.2 cm (IQR, 3.0-3.9 cm). The median TLR before treatment was 0.97 (IQR, 0.88-0.98), with a variance of 0.02, and the median TLR after treatment was 0.85 (IQR, 0.79-1), with a variance of 0.01; both findings indicate a narrow range of 18F-FMISO uptake in HCC. The Spearman rank correlation coefficient was 0.87, indicating a high correlation between change in TLR and nonviable tumor. Conclusion Although there was a correlation between change in TLR and response to treatment, the low signal-to-noise ratio of 18F-FMISO in the liver limited its use in HCC. Keywords: Molecular Imaging-Clinical Translation, Embolization, Abdomen/Gastrointestinal, Liver Clinical trial registration no. NCT02695628 © RSNA, 2022.
Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Flúor , Humanos , Hipóxia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Misonidazol/análogos & derivados , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos RadiofarmacêuticosRESUMO
PURPOSE: During transcatheter hepatic therapy, the cystic artery feeding the gallbladder may inadvertently be exposed to tumor therapy. Localization of the cystic artery may help prevent exposure. The objective of this study was to compare the application of a vessel tracking system software based on three-dimensional (3D) angiography versus standard two-dimensional (2D) angiography for identifying the cystic artery and its origin. MATERIALS AND METHODS: A software system that can rapidly localize the cystic artery from a 3D common hepatic angiogram was applied in 25 patients and was compared with manual localization of the cystic artery with conventional 2D digital subtraction common hepatic angiograms. RESULTS: With the vessel tracking software prototype, 28 cystic arteries were retrogradely tracked in 25 of 25 cases. The origin sites were correctly located by the software in 27 of 28 cystic arteries, with one mistracked as a result of streak artifact. By contrast, on standard 2D hepatic angiography, the cystic artery was deemed visible with certainty in 12 of 25 cases (P < .001). The vessel tracking system revealed a 56% prevalence of extraanatomic distribution by the cystic artery, with the most common supply going to segment 5 liver parenchyma. CONCLUSIONS: The 3D vessel rapid tracking system has advantages over conventional 2D hepatic angiography in revealing the cystic artery and its origin site. It is also an important tool to identify the complete distribution of the cystic artery without superselective angiography. Supply to adjacent hepatic parenchyma or tumor by the cystic artery is not insignificant and should be considered during hepatic therapies.
Assuntos
Angiografia Digital , Angiografia/métodos , Vesícula Biliar/irrigação sanguínea , Artéria Hepática/diagnóstico por imagem , Imageamento Tridimensional , Neoplasias Hepáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Artefatos , Quimioembolização Terapêutica/efeitos adversos , Distribuição de Qui-Quadrado , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/tratamento farmacológico , Valor Preditivo dos Testes , Estudos Retrospectivos , SoftwareRESUMO
OBJECTIVE: Arterially directed therapies for hepatocellular carcinoma are used for patients who are not candidates for surgery or ablation and for those who need a bridge or down-staging to liver transplantation. These therapies seem to prolong the overall survival when compared with supportive care. CONCLUSION: Chemoembolization, particle embolization, drug-eluting beads, and radioembolization have been used for locoregional control. This review discusses patient selection, techniques, safety, clinical outcomes, and imaging findings related to these therapies.
Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Estadiamento de Neoplasias/métodos , Artérias , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica , Diagnóstico por Imagem , Sistemas de Liberação de Medicamentos , Embolização Terapêutica/efeitos adversos , Humanos , Neoplasias Hepáticas/patologia , Microesferas , Seleção de PacientesRESUMO
Hepatic arterial embolization (HAE) is a treatment used in the management of primary and some metastatic hepatic tumors. Complications of HAE are similar to those seen in other treatments, particularly transcatheter arterial chemoembolization (TACE), but without the possibility for chemotherapy related side effects. Particle reflux into the cystic artery is generally clinically occult but gallbladder ischemia severe enough to require cholecystostomy tube placement can occur. The authors discuss the case of a patient who underwent HAE and subsequently required a cholecystostomy tube due to development of acute cholecystitis.
RESUMO
PURPOSE: Small-cell lung cancer (SCLC) is the deadliest form of lung cancer, partly because of its short doubling time. Delays in imaging identification and diagnosis of nodules create a risk for stage migration. The purpose of our study was to determine if a machine learning radiomics model can detect SCLC on computed tomography (CT) among all nodules at least 1 cm in size. MATERIALS AND METHODS: Computed tomography scans from a single institution were selected and resampled to 1 × 1 × 1 mm. Studies were divided into SCLC and other scans comprising benign, adenocarcinoma, and squamous cell carcinoma that were segregated into group A (noncontrast scans) and group B (contrast-enhanced scans). Four machine learning classification models, support vector classifier, random forest (RF), XGBoost, and logistic regression, were used to generate radiomic models using 59 quantitative first-order and texture Imaging Biomarker Standardization Initiative compliant PyRadiomics features, which were found to be robust between two segmenters with minimum Redundancy Maximum Relevance feature selection within each leave-one-out-cross-validation to avoid overfitting. The performance was evaluated using a receiver operating characteristic curve. A final model was created using the RF classifier and aggregate minimum Redundancy Maximum Relevance to determine feature importance. RESULTS: A total of 103 studies were included in the analysis. The area under the receiver operating characteristic curve for RF, support vector classifier, XGBoost, and logistic regression was 0.81, 0.77, 0.84, and 0.84 in group A, and 0.88, 0.87, 0.85, and 0.81 in group B, respectively. Nine radiomic features in group A and 14 radiomic features in group B were predictive of SCLC. Six radiomic features overlapped between groups A and B. CONCLUSION: A machine learning radiomics model may help differentiate SCLC from other lung lesions.
Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Aprendizado de Máquina , Curva ROC , Estudos RetrospectivosRESUMO
BACKGROUND: Stenting of the iliofemoral vein may be an effective treatment to improve post-thrombotic symptoms. Iliofemoral vein stents have requirements different from those of lower extremity artery stents, and there is a paucity of literature regarding the biomechanical motion of the iliofemoral vein. METHODS: In a novel cadaveric model, stents were bilaterally inserted into the veins in the iliofemoral region. The veins were pressurized and underwent computed tomography angiography at various hip angle positions. In addition, 21 patients with iliofemoral vein disease had supine computed tomography angiography before and after stenting. The stents and vasculature were reconstructed into three-dimensional geometric models to quantify stent deformations and the interaction between the iliofemoral vein, inguinal ligament, and pubis bone due to hip flexion-extension. RESULTS: In the cadavers, from supine to 30 to 45 degrees and 50 to 75 degrees of hip flexion, iliofemoral vein stents became less compressed (4.5% minor diameter expansion), and the inguinal ligament was separated from the iliofemoral veins by 1 to 3 cm in all hip positions. In the patients, the pubis compressed 47% of femoral veins; 78% were within 3 mm of the pubis. There was also evidence of contrast-enhanced flow disruption at the superior ramus. CONCLUSIONS: The cadaver and clinical evidence shows that contrary to widely accepted dogma, the common femoral vein is not compressed by the inguinal ligament during hip flexion but rather by the superior ramus of the pubis during hip extension, which may have an impact on future stent design and influence deep venous thrombosis treatment strategies.
Assuntos
Procedimentos Endovasculares/instrumentação , Veia Femoral/diagnóstico por imagem , Articulação do Quadril/fisiologia , Stents , Trombose Venosa/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Flebografia , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Adulto JovemRESUMO
Moyamoya syndrome and cerebral aneurysm formation are rare cerebrovascular manifestations of Alagille syndrome. Although previously reported in isolation, occurrence of these complications in a single patient has not been described. We report clinical and imaging features of synchronous moyamoya syndrome and ruptured cerebral aneurysm in a patient with Alagille syndrome.
Assuntos
Síndrome de Alagille/complicações , Aneurisma Roto/complicações , Doença de Moyamoya/complicações , Adulto , Síndrome de Alagille/diagnóstico , Aneurisma Roto/diagnóstico , Angiografia Cerebral/métodos , Feminino , Humanos , Doença de Moyamoya/diagnóstico , Microtomografia por Raio-X/métodosRESUMO
PURPOSE: The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. METHODS: The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. RESULTS: Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. CONCLUSION: Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.
Assuntos
Biópsia com Agulha de Grande Calibre/estatística & dados numéricos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Animais , Biópsia/métodos , Biópsia com Agulha de Grande Calibre/instrumentação , Feminino , Humanos , Rim/patologia , Fígado/patologia , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Modelos Animais , Músculo Esquelético/patologia , Agulhas , Reprodutibilidade dos Testes , SuínosRESUMO
Transjugular intrahepatic portosystemic shunt (TIPS) creation is a widely adopted treatment for complications of portal hypertension, including variceal hemorrhage and refractory ascites. The creation of a TIPS requires establishing a pathway from the portal vein to a hepatic vein or inferior vena cava through hepatic parenchyma, using a stent or stent graft to sustain patency of this pathway. Because it is a technically challenging procedure and patients may be critically ill with severe comorbidities, the risk of procedural complications and mortality is substantial. This article discusses known complications of the TIPS procedure and ways to minimize their occurrence.