Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 555(7698): 657-661, 2018 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-29562238

RESUMO

Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.


Assuntos
Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Movimento , Dispositivos Eletrônicos Vestíveis , Adulto , Ingestão de Líquidos/fisiologia , Feminino , Cabeça/fisiologia , Humanos , Campos Magnéticos , Esportes/fisiologia
2.
Ann Vasc Surg ; 109: 458-465, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39096955

RESUMO

BACKGROUND: Deep hypothermic circulatory arrest (DHCA) in patients undergoing descending thoracic (DTAA) or thoracoabdominal aortic aneurysm (TAAA) repair is associated with increased morbidity and mortality. We present our outcomes after open DTAA and TAAA repair with and without DHCA. METHODS: From 1999 to 2022, 81 (38.8%) patients undergoing DTAA or TAAA repair required DHCA because proximal cross-clamping was not feasible or aneurysmal pathology extended into the arch and 128 (61.2%) patients required only distal bypass. Because of intrinsic pathological differences in patients requiring DHCA, confidence intervals (CIs) were used to compare groups in lieu of formal hypothesis tests. RESULTS: DHCA patients had more chronic dissections (64.2% vs. 43.8%, 95% CI for difference: 6-35%) and higher body mass indices (29.5 ± 6.8 vs. 27.2 ± 6.6, CI: 26-421%). More non-DHCA patients had medial degeneration (9.9% vs. 31.3%, CI: -33 to -7%). There were 10 (12.4%) in-hospital deaths for the DHCA and 10 (7.8%) for the non-DHCA group (CI: -5 to 14%). Survival at 10 years was 52.6% (CI: 42.1-65.7%) for the non-DHCA group and 48.3% (CI: 40.3-57.9%) for the DHCA group. The only meaningful differences in postoperative outcomes were intensive care unit (5.5 days vs. 6 days, CI: 12-410%) and hospital stay (19 days vs. 12 days, CI: 74-470%), which were longer in the DHCA group. CONCLUSIONS: Despite longer intensive care unit and hospital length of stays, selective use of DHCA is safe and effective with comparable morbidity and mortality to non-DHCA in open DTAA and TAAA repair.

3.
J Oncol Pharm Pract ; : 10781552241265280, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39091073

RESUMO

INTRODUCTION: The treatment of cancer is associated with high risk for toxicity and high cost. Strategies to enhance the value, quality, and safety of cancer care are often managed independently of one another. Oncology stewardship is a potential framework to unify these efforts and enhance outcomes. This landscape survey establishes baseline information on oncology stewardship in the United States. METHODS: The Hematology/Oncology Pharmacy Association (HOPA) distributed a 38-item survey composed of demographic, institutional, clinical decision-making, support staff, metrics, and technology sections to 675 HOPA members between 9 September 2022 and 9 October 2022. RESULTS: Most organizations (78%) have adopted general pharmacy stewardship practices; however, only 31% reported having established a formalized oncology stewardship team. More than 70% of respondents reported implementation of biosimilars, formulary management, and dose rounding as oncology stewardship initiatives in both inpatient and outpatient settings. Frequently cited barriers to oncology stewardship included lack of clinical pharmacist availability (74%), lack of oncology stewardship training (62%), lack of physician/provider buy-in (32%), and lack of cost-saving metrics (33%). Only 6.6% of survey respondents reported their organization had defined "value in oncology." Lack of a formalized stewardship program was most often cited (77%) as the rationale for not defining value. CONCLUSIONS: Less than one-third of respondents have established oncology stewardship programs; however, most are providing oncology stewardship practices. This manuscript serves as a call to action for stakeholders to work together to formalize oncology stewardship programs that optimize value, quality, and safety for patients with cancer.

4.
Perfusion ; : 2676591241278616, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39185741

RESUMO

Sternal reentry for repair of aortic pseudoaneurysms poses a unique technical challenge to prevent exsanguination. Initiation of peripheral cardiopulmonary bypass and deep hypothermic circulatory arrest prior to reentry are the cornerstones of a successful surgical approach. Adjunctive bilateral antegrade cerebral perfusion increases safe arrest time and reduces neurologic morbidity. Herein, we describe our safe reentry technique for aortic pseudoaneurysm repair in two patients.

5.
Neuroimage ; 271: 120024, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36918138

RESUMO

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.


Assuntos
Encéfalo , Magnetoencefalografia , Humanos , Criança , Magnetoencefalografia/métodos , Encéfalo/fisiologia , Campos Magnéticos , Razão Sinal-Ruído
6.
Neuroimage ; 274: 120157, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37149237

RESUMO

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.


Assuntos
Magnetoencefalografia , Dispositivos Eletrônicos Vestíveis , Humanos , Magnetoencefalografia/métodos , Movimento , Campos Magnéticos , Fenômenos Eletromagnéticos , Encéfalo/fisiologia
7.
Sensors (Basel) ; 23(12)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37420622

RESUMO

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction. However, present technologies are limited, either by poor performance (low spatial/temporal precision) or an unnatural scanning environment (claustrophobic scanners, with interactions via video). Here, we describe hyperscanning using wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs). We demonstrate our approach by simultaneously measuring brain activity in two subjects undertaking two separate tasks-an interactive touching task and a ball game. Despite large and unpredictable subject motion, sensorimotor brain activity was delineated clearly, and the correlation of the envelope of neuronal oscillations between the two subjects was demonstrated. Our results show that unlike existing modalities, OPM-MEG combines high-fidelity data acquisition and a naturalistic setting and thus presents significant potential to investigate neural correlates of social interaction.


Assuntos
Magnetoencefalografia , Dispositivos Eletrônicos Vestíveis , Humanos , Magnetoencefalografia/métodos , Neuroimagem Funcional , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia
8.
J Pharm Technol ; 39(6): 281-285, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37974597

RESUMO

Background: Pharmacist order verification is a critical step in ensuring medication safety for patients. While the second pharmacist verification (SPV) before dispensing anticancer therapies has been a longstanding practice, its continued necessity in the context of modern electronic health systems lacks robust evidence. Objective: This study aimed to assess the frequency of interventions performed by a second pharmacist to determine the ongoing effectiveness of the SPV process. Methods: This retrospective chart review was conducted at the Mayo Clinic, encompassing all anticancer therapy orders that necessitated an SPV. The study period extended from January 1, 2019, to June 30, 2021, and included inpatient and outpatient anticancer orders. The quantification and reporting of alterations made to discrete order fields subsequent to initial pharmacist verification of clinical significance were performed, utilizing the total number of anticancer therapy orders as the denominator. Results: Approximately 300 000 anticancer therapy orders were screened for inclusion criteria and 2.6% (N = 7634) of orders were modified on the SPV. Most changes were in the categories of rate (N = 1962), order start time (N = 1219), and pharmacy communication note (N = 777). Dosing changes greater than 10% accounted for 0.03% (N = 99) of the orders, with 10 anticancer therapies responsible for more than 50% of these changes. Conclusion and relevance: This study represents the largest report on the impact of SPV in a modern era. Our results suggest the SPV may be valuable for a small proportion of chemotherapy orders but raises questions about the necessity for broad application of this practice.

9.
Neuroimage ; 252: 119027, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35217205

RESUMO

Optically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements. Here we demonstrate use of a triaxial OPM formulation, able to characterise the full 3D neuromagnetic field vector. We show that this novel sensor is able to characterise magnetic fields with high accuracy and sensitivity that matches conventional (dual-axis) OPMs. We show practicality via measurement of biomagnetic fields from both the heart and the brain. Using simulations, we demonstrate how triaxial measurement offers improved cortical coverage, especially in infants. Finally, we introduce a new 3D-printed child-friendly OPM-helmet and demonstrate feasibility of triaxial measurement in a five-year-old. In sum, the data presented demonstrate that triaxial OPMs offer a significant improvement over dual-axis variants and are likely to become the sensor of choice for future MEG systems, particularly for deployment in paediatric populations.


Assuntos
Magnetoencefalografia , Magnetometria , Encéfalo , Pré-Escolar , Desenho de Equipamento , Estudos de Viabilidade , Humanos
10.
Neuroimage ; 253: 119084, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35278706

RESUMO

Magnetoencephalography (MEG) has been revolutionised by optically pumped magnetometers (OPMs). "OPM-MEG" offers higher sensitivity, better spatial resolution, and lower cost than conventional instrumentation based on superconducting quantum interference devices (SQUIDs). Moreover, because OPMs are small, lightweight, and portable they offer the possibility of lifespan compliance and (with control of background field) motion robustness, dramatically expanding the range of MEG applications. However, OPM-MEG remains nascent technology; it places stringent requirements on magnetic shielding, and whilst a number of viable systems exist, most are custom made and there have been no cross-site investigations showing the reliability of data. In this paper, we undertake the first cross-site OPM-MEG comparison, using near identical commercial systems scanning the same participant. The two sites are deliberately contrasting, with different magnetic environments: a "green field" campus university site with an OPM-optimised shielded room (low interference) and a city centre hospital site with a "standard" (non-optimised) MSR (higher interference). We show that despite a 20-fold difference in background field, and a 30-fold difference in low frequency interference, using dynamic field control and software-based suppression of interference we can generate comparable noise floors at both sites. In human data recorded during a visuo-motor task and a face processing paradigm, we were able to generate similar data, with source localisation showing that brain regions could be pinpointed with just ∼10 mm spatial discrepancy and temporal correlations of > 80%. Overall, our study demonstrates that, with appropriate field control, OPM-MEG systems can be sited even in city centre hospital locations. The methods presented pave the way for wider deployment of OPM-MEG.


Assuntos
Encéfalo , Magnetoencefalografia , Desenho de Equipamento , Humanos , Fenômenos Magnéticos , Magnetoencefalografia/métodos , Reprodutibilidade dos Testes
11.
Phys Rev Lett ; 128(16): 163602, 2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-35522487

RESUMO

We demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with ^{87}Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/sqrt[Hz] with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth's field.

12.
Ann Pharmacother ; : 10600280211073322, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35135362

RESUMO

OBJECTIVE: To review the new indication of cyclin-dependent kinase (CDK4/6) inhibitor abemaciclib for the adjuvant treatment of hormone receptor positive (HR+), human epidermal growth factor receptor 2 negative (HER2-), axillary lymph node (LN) positive early breast cancer (EBC) at high risk of recurrence and a Ki-67 ≥20%. DATA SOURCES: A literature search was performed through PubMed, ClinicalTrials.gov, and Food and Drug Administration (FDA) website (February 1, 2018, to December 23, 2021) to identify relevant information. STUDY SELECTION AND DATA EXTRACTION: Human and animal studies related to pharmacology, pharmacokinetics, efficacy, and safety of abemaciclib were identified. DATA SYNTHESIS: Addition of abemaciclib to standard of care endocrine therapy (ET) for patients with high-risk clinicopathologic features and Ki-67 ≥20% demonstrated 30% reduction in the risk of developing invasive disease and distant recurrence. At 15.5 months, abemaciclib + ET demonstrated a significant improvement in invasive disease-free survival (IDFS) vs ET alone (hazard ratio [HR], 0.75; 95% confidence interval [CI], 0.60-0.93, P = 0.01). At 27 months, IDFS benefit was maintained (HR, 0.70; 95% CI, 0.59-0.82, P < 0.0001). Diarrhea occurred in more than 80% of patients in the abemaciclib arm. RELEVANCE TO PATIENT CARE AND CLINICAL PRACTICE: This review describes the clinical applicability of adjuvant abemaciclib for patients with HR+, HER2- EBC at high risk for recurrence. CONCLUSION: Adjuvant abemaciclib significantly reduces the risk for early development of invasive disease and distant recurrence in patients with HR+, HER2- node positive EBC. Longer follow-up is needed to determine the impact of adjuvant abemaciclib on late disease recurrence and survival outcomes.

13.
Occup Environ Med ; 79(10): 713-716, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35927001

RESUMO

OBJECTIVES: To compare the impact of occupational exposures to SARS-CoV-2 positive patients and SARS-CoV-2 positive coworkers, by comparing the frequency of occupational exposure incidents and the rate of healthcare personnel (HCP) who developed a positive PCR test for SARS-COV-2 after occupational exposure to the two different types of infectious individuals. METHODS: A retrospective analysis of all confirmed higher risk occupational exposure incidents that occurred in HCP from 20 March 2020 to 31 December 2020 at a large multisite US academic medical centre. Comparisons between groups for source type were performed using unpaired Student's t-test for continuous variables and the χ2 test for categorical variables, regression analysis was conducted to assess the associations between source type and risk of positive COVID-19 test after occupational exposure. RESULTS: In total, 2253 confirmed medium or high-risk occupational exposures occurred during the study period. 57% were exposures from coworker sources. Each source individual exposed a mean of 2.6 (95% CI 2.3 to 2.9) HCP; during postexposure surveillance, 4.5% of exposed HCP tested positive within 14 days. A coworker source on average exposed 2.2 (95% CI 2.01 to 2.4) other HCP and infected 0.14 (95% CI 0.1 to 0.17) HCP, while patient sources exposed a mean of 3.4 (95% CI 2.6 to 4.2) HCP but only infected 0.07 (95% CI 0.04 to 0.11) HCP. The multivariate analysis demonstrated that exposure to a coworker source carried a higher risk of testing positive compared with exposure to a patient source (OR 3.22; 95% CI 1.72 to 6.04). CONCLUSION: Occupational exposures to coworker sources were not only more frequent but also associated with triple the risk of developing COVID-19 infection, compared with exposures to patient sources.


Assuntos
COVID-19 , COVID-19/epidemiologia , Atenção à Saúde , Pessoal de Saúde , Humanos , Estudos Retrospectivos , SARS-CoV-2
14.
J Card Surg ; 37(12): 5509-5512, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36259754

RESUMO

Acute type A aortic dissection with malperfusion syndrome is associated with high mortality. Despite having no consensus-based guidelines, we believe the "endovascular-first" approach should be undertaken. This report describes the successful management of iliofemoral and visceral malperfusion syndrome with endovascular revascularization followed by delayed proximal aortic repair after acute type A aortic dissection.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Vasculares , Síndrome , Resultado do Tratamento , Doença Aguda , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos
15.
J Emerg Med ; 63(3): 389-398, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36096961

RESUMO

BACKGROUND: D-dimer testing rules out deep vein thrombosis (DVT) and pulmonary embolism (PE) in low-risk emergency department (ED) patients. Most research has measured fibrin-equivalent units (FEUs), however, many laboratories measure D-dimer units (DDUs). OBJECTIVE: Our aim was to determine whether either DDU measurements or FEU measurements can rule out DVT/PE using traditional or age-related cutoff values. METHODS: We performed a de-identified multicenter retrospective evaluation of D-dimer in nonpregnant adult ED patients to evaluate for DVT/PE. DDUs were multiplied by 2 to determine equivalent FEUs prior to analysis. Sensitivity measurements for D-dimer were calculated for FEUs, DDUs, combined FEU/DDUs, and multiple age-adjusted values. RESULTS: We identified 47,088 ED patients with a D-dimer laboratory value (27,307 FEUs/19,781 DDUs) and 1623 DVT/PEs. The median combined FEU/DDU D-dimer was 400 ng/mL FEUs (interquartile range [IQR] 300-900 ng/mL FEUs) for patients without a DVT/PE vs 2530 ng/mL FEU (IQR 1094-6000 ng/mL FEUs) with a DVT/PE (p < 0.001), overall sensitivity of 87.3% (95% confidence interval [CI] 87.0-87.6%) and negative predictive value of 99.3% (95% CI 99.2-99.4%). Individually, FEUs performed better than DDUs, with sensitivities of 88.0% (95% CI 85.8-89.9%) and 86.1% (95% CI 83.1-88.7%), respectively; however, this difference was not statistically significant. Combined age-adjusted performance had a sensitivity of 90.3% (95% CI 88.3-92.0%); however, a new DDU-only age-adjusted criteria had the highest sensitivity of 91.1% (95% CI 87.9-93.6%). CONCLUSIONS: Our undifferentiated D-dimer measurements had a slightly lower sensitivity to rule out DVT/PE than reported previously. Our data support using either DDU or FEU measurements for all ages or when using various age-adjusted criteria to rule out DVT/PE.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio , Embolia Pulmonar , Trombose Venosa , Adulto , Humanos , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Valor Preditivo dos Testes , Embolia Pulmonar/diagnóstico , Estudos Retrospectivos , Trombose Venosa/diagnóstico , Sensibilidade e Especificidade
16.
Neuroimage ; 236: 118025, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33838266

RESUMO

The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a "wearable" scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of 'OPM-MEG', one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance.


Assuntos
Córtex Cerebral/fisiologia , Fenômenos Magnéticos , Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Modelos Teóricos , Adulto , Artefatos , Simulação por Computador , Desenho de Equipamento , Humanos , Campos Magnéticos , Masculino
17.
Neuroimage ; 230: 117815, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33524584

RESUMO

Optically-pumped magnetometers (OPMs) offer the potential for a step change in magnetoencephalography (MEG) enabling wearable systems that provide improved data quality, accommodate any subject group, allow data capture during movement and potentially reduce cost. However, OPM-MEG is a nascent technology and, to realise its potential, it must be shown to facilitate key neuroscientific measurements, such as the characterisation of brain networks. Networks, and the connectivities that underlie them, have become a core area of neuroscientific investigation, and their importance is underscored by many demonstrations of their disruption in brain disorders. Consequently, a demonstration of network measurements using OPM-MEG would be a significant step forward. Here, we aimed to show that a wearable 50-channel OPM-MEG system enables characterisation of the electrophysiological connectome. To this end, we measured connectivity in the resting state and during a visuo-motor task, using both OPM-MEG and a state-of-the-art 275-channel cryogenic MEG device. Our results show that resting-state connectome matrices from OPM and cryogenic systems exhibit a high degree of similarity, with correlation values >70%. In addition, in task data, similar differences in connectivity between individuals (scanned multiple times) were observed in cryogenic and OPM-MEG data, again demonstrating the fidelity of the OPM-MEG device. This is the first demonstration of network connectivity measured using OPM-MEG, and results add weight to the argument that OPMs will ultimately supersede cryogenic sensors for MEG measurement.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Magnetoencefalografia/métodos , Magnetometria/métodos , Desempenho Psicomotor/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Feminino , Humanos , Magnetoencefalografia/instrumentação , Magnetometria/instrumentação , Masculino , Adulto Jovem
18.
Neuroimage ; 241: 118401, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34273527

RESUMO

Optically-pumped magnetometers (OPMs) are highly sensitive, compact magnetic field sensors, which offer a viable alternative to cryogenic sensors (superconducting quantum interference devices - SQUIDs) for magnetoencephalography (MEG). With the promise of a wearable system that offers lifespan compliance, enables movement during scanning, and provides higher quality data, OPMs could drive a step change in MEG instrumentation. However, this potential can only be realised if background magnetic fields are appropriately controlled, via a combination of optimised passive magnetic screening (i.e. enclosing the system in layers of high-permeability materials), and electromagnetic coils to further null the remnant magnetic field. In this work, we show that even in an OPM-optimised passive shield with extremely low (<2 nT) remnant magnetic field, head movement generates significant artefacts in MEG data that manifest as low-frequency interference. To counter this effect we introduce a magnetic field mapping technique, in which the participant moves their head to sample the background magnetic field using a wearable sensor array; resulting data are compared to a model to derive coefficients representing three uniform magnetic field components and five magnetic field gradient components inside the passive shield. We show that this technique accurately reconstructs the magnitude of known magnetic fields. Moreover, by feeding the obtained coefficients into a bi-planar electromagnetic coil system, we were able to reduce the uniform magnetic field experienced by the array from a magnitude of 1.3±0.3 nT to 0.29±0.07 nT. Most importantly, we show that this field compensation generates a five-fold reduction in motion artefact at 0‒2 Hz, in a visual steady-state evoked response experiment using 6 Hz stimulation. We suggest that this technique could be used in future OPM-MEG experiments to improve the quality of data, especially in paradigms seeking to measure low-frequency oscillations, or in experiments where head movement is encouraged.


Assuntos
Encéfalo/fisiologia , Potenciais Evocados Visuais/fisiologia , Movimentos da Cabeça/fisiologia , Campos Magnéticos , Magnetoencefalografia/métodos , Dispositivos Eletrônicos Vestíveis , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Dispositivos de Proteção da Cabeça , Humanos , Magnetoencefalografia/instrumentação , Magnetometria/instrumentação , Magnetometria/métodos
19.
Neuroimage ; 225: 117443, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33059052

RESUMO

Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth. We found that simulated hippocampal sources gave rise to dipolar field patterns with one scalp surface field extremum at the temporal lobe and a corresponding maximum or minimum at the roof of the mouth. We then constructed a fitted dental mould to accommodate an Optically Pumped Magnetometer (OPM). We collected data using a previously validated hippocampal-dependant task to test the empirical utility of a mouth-based sensor, with an accompanying array of left and right temporal lobe OPMs. We found that the mouth sensor showed the greatest task-related theta power change. We found that this sensor had a mild effect on the reconstructed power in the hippocampus (~10% change) but that coherence images between the mouth sensor and reconstructed source images showed a global maximum in the right hippocampus. We conclude that augmenting a scalp-based MEG array with sensors in the mouth shows unique promise for both basic scientists and clinicians interested in interrogating the hippocampus.


Assuntos
Hipocampo/diagnóstico por imagem , Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Neuroimagem Funcional , Hipocampo/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Boca , Palato Duro
20.
J Card Surg ; 36(3): 886-893, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33442874

RESUMO

BACKGROUND: Minimally invasive cardiac surgery may reduce surgical trauma, diminish postoperative pain and improve quality of life (QOL). The aim of this study is to assess pain, hospital anxiety and depression scale (HADS), and QOL in patients undergoing minimally invasive aortic surgery. METHODS: This is a prospective, single-center cohort study of 24 consecutive patients undergoing upper ministernotomy aortic valve, aortic root, and concomitant aortic valve and ascending aorta replacement. Visual analog scale (VAS) pain scores and HADS and Short-Form-36 (SF-36) questionnaires were evaluated at preoperative baseline, during hospitalization, and at 1 and 3 months postoperatively. RESULTS: At discharge, the average VAS pain score was significantly lower than postoperative Day 1 (2.7 ± 0.4 vs. 6.5 ± 0.4; p ≤ .001). By 1 month, the pain scores were not significantly different from baseline (1.7 ± 0.4 vs. 1.0 ± 0.4; p = 1.000), and by 3 months, pain scores returned to baseline (1.0 ± 0.4; p = 1.000). HADS scores show that compared with preoperative baseline, average anxiety scores decreased by 1 month (3.1 ± 0.7 vs. 4.3 ± 0.6; p = 1.000) and decreased significantly by 3 months (1.8 ± 0.7 vs. 4.3 ± 0.6; p = .012). Additionally, depression scores were unchanged at 1 month (3.0 ± 0.4 vs. 3.1. ± 0.4; p = 1.000) and decreased by 3 months (1.3 ± 0.5 vs. 3.0 ± 0.4; p = .060). SF-36 scores revealed no changes in scores in 7 of 8 domains at 1 month and a significant increase in "physical functioning," "energy," and "general health" domains compared to preoperative baseline at 3 months. CONCLUSIONS: Following minimally invasive aortic surgery, VAS pain scores, HADS and scores in 7 of 8 SF-36 domains returned to preoperative baseline or improved compared to preoperative baseline at 1 month. At 3 months, scores in 3 of 8 SF-36 domains significantly improved compared to preoperative baseline. Larger studies are necessary for further investigation.


Assuntos
Depressão , Qualidade de Vida , Ansiedade/epidemiologia , Ansiedade/etiologia , Aorta , Estudos de Coortes , Depressão/epidemiologia , Depressão/etiologia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Dor , Medição da Dor , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA