Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neurosurg Focus ; 51(2): E11, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34333483

RESUMO

OBJECTIVE: Augmented reality (AR) has the potential to improve the accuracy and efficiency of instrumentation placement in spinal fusion surgery, increasing patient safety and outcomes, optimizing ergonomics in the surgical suite, and ultimately lowering procedural costs. The authors sought to describe the use of a commercial prototype Spine AR platform (SpineAR) that provides a commercial AR head-mounted display (ARHMD) user interface for navigation-guided spine surgery incorporating real-time navigation images from intraoperative imaging with a 3D-reconstructed model in the surgeon's field of view, and to assess screw placement accuracy via this method. METHODS: Pedicle screw placement accuracy was assessed and compared with literature-reported data of the freehand (FH) technique. Accuracy with SpineAR was also compared between participants of varying spine surgical experience. Eleven operators without prior experience with AR-assisted pedicle screw placement took part in the study: 5 attending neurosurgeons and 6 trainees (1 neurosurgical fellow, 1 senior orthopedic resident, 3 neurosurgical residents, and 1 medical student). Commercially available 3D-printed lumbar spine models were utilized as surrogates of human anatomy. Among the operators, a total of 192 screws were instrumented bilaterally from L2-5 using SpineAR in 24 lumbar spine models. All but one trainee also inserted 8 screws using the FH method. In addition to accuracy scoring using the Gertzbein-Robbins grading scale, axial trajectory was assessed, and user feedback on experience with SpineAR was collected. RESULTS: Based on the Gertzbein-Robbins grading scale, the overall screw placement accuracy using SpineAR among all users was 98.4% (192 screws). Accuracy for attendings and trainees was 99.1% (112 screws) and 97.5% (80 screws), respectively. Accuracy rates were higher compared with literature-reported lumbar screw placement accuracy using FH for attendings (99.1% vs 94.32%; p = 0.0212) and all users (98.4% vs 94.32%; p = 0.0099). The percentage of total inserted screws with a minimum of 5° medial angulation was 100%. No differences were observed between attendings and trainees or between the two methods. User feedback on SpineAR was generally positive. CONCLUSIONS: Screw placement was feasible and accurate using SpineAR, an ARHMD platform with real-time navigation guidance that provided a favorable surgeon-user experience.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X
2.
BMJ Case Rep ; 17(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589239

RESUMO

A woman in her late 50s with a left frontal lobe convexity meningioma underwent an elective endovascular embolisation of the left middle meningeal artery and distal branches of the left superficial temporal artery prior to surgical resection of the tumour. On postoperative day 46, she developed scalp necrosis, leading to poor wound healing requiring wound debridement and a complex plastic surgery reconstruction with a rotational flap. Endovascular embolisation of vascular tumours prior to surgical resection does not come without risks. The lack of consistency in the literature regarding indication, technique and outcomes makes it difficult to define the exact role of preoperative meningioma embolisation.


Assuntos
Neoplasias Meníngeas , Meningioma , Feminino , Humanos , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/cirurgia , Meningioma/diagnóstico por imagem , Meningioma/cirurgia , Necrose/etiologia , Couro Cabeludo/cirurgia , Artérias Temporais/diagnóstico por imagem , Artérias Temporais/cirurgia , Pessoa de Meia-Idade
3.
Pediatr Neurosurg ; 49(2): 99-104, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24434861

RESUMO

Sturge-Weber syndrome (SWS) is a neurocutaneous disorder comprised typically of a facial nevus, leptomeningeal angioma with calcifications, and seizures. SWS without a port-wine stain is a rare variant with only 30 cases reported in the literature. Here, a case of an 8-year-old girl with no cutaneous abnormalities presenting with medically intractable epilepsy and MRI and CT findings consistent with SWS is described. The patient underwent multistage surgery with subdural electrode monitoring before and after resection of the epileptogenic focus, with complete excision of the lesion and postoperative resolution of her seizures. This is the first reported case of three-stage surgery for localized resection of the seizure focus for SWS.


Assuntos
Neoplasias Meníngeas/diagnóstico , Neoplasias Meníngeas/cirurgia , Mancha Vinho do Porto , Síndrome de Sturge-Weber/diagnóstico , Síndrome de Sturge-Weber/cirurgia , Criança , Feminino , Humanos
4.
J Neurosurg Case Lessons ; 1(23): CASE21114, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-36046517

RESUMO

BACKGROUND: Virtual reality (VR) offers an interactive environment for visualizing the intimate three-dimensional (3D) relationship between a patient's pathology and surrounding anatomy. The authors present a model for using personalized VR technology, applied across the neurosurgical treatment continuum from the initial consultation to preoperative surgical planning, then to intraoperative navigation, and finally to postoperative visits, for various tumor and vascular pathologies. OBSERVATIONS: Five adult patients undergoing procedures for spinal cord cavernoma, clinoidal meningioma, anaplastic oligodendroglioma, giant aneurysm, and arteriovenous malformation were included. For each case, 360-degree VR (360°VR) environments developed using Surgical Theater were used for patient consultation, preoperative planning, and/or intraoperative 3D navigation. The custom 360°VR model was rendered from the patient's preoperative imaging. For two cases, the plan changed after reviewing the patient's 360°VR model from one based on conventional Digital Imaging and Communications in Medicine imaging. LESSONS: Live 360° visualization with Surgical Theater in conjunction with surgical navigation helped validate the decisions made intraoperatively. The 360°VR models provided visualization to better understand the lesion's 3D anatomy, as well as to plan and execute the safest patient-specific approach, rather than a less detailed, more standardized one. In all cases, preoperative planning using the patient's 360°VR model had a significant impact on the surgical approach.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA