Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 149(12): 3335-3345, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38695841

RESUMO

In this study, a microfluidic-based system utilizing colorimetric loop-mediated isothermal amplification (LAMP) is introduced for the quantitative analysis of nucleic acid targets. This system offers a user-friendly and cost-effective platform for the multiplexed genetic diagnosis of various infectious diseases across multiple samples. It includes time-lapse imaging equipment for capturing images of the microfluidic device during the LAMP assay and a hue-based quantitative analysis software to analyze the LAMP reaction, streamlining diagnostic procedures. An electric pipette was used to simplify the loading of samples and LAMP reagents into the device, allowing easy operation even by untrained individuals. The hue-based analysis software employs efficient image processing and post-processing techniques to calculate DNA amplification curves based on color changes in multiple reaction chambers. This software automates several tasks, such as identifying reaction chamber areas from time-lapse images, quantifying color information within each chamber, correcting baselines of DNA amplification curves, fitting experimental data to theoretical curves, and determining the threshold time for each curve. To validate the developed system, conventional off-chip LAMP assays were conducted with a 25 µL reaction mixture in 0.2 mL polymerase chain reaction (PCR) tubes using a real-time turbidimeter. The results indicated that the threshold time obtained using the colorimetric LAMP assay in the developed system is comparable to that obtained with real-time turbidity measurements in PCR tubes, demonstrating the system's capability for quantitative analysis of target nucleic acids, including those from human herpesviruses.


Assuntos
Colorimetria , Dispositivos Lab-On-A-Chip , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Humanos , Colorimetria/métodos , Colorimetria/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , DNA Viral/análise , DNA Viral/genética , Viroses/diagnóstico , Limite de Detecção
2.
Chem Pharm Bull (Tokyo) ; 71(1): 15-18, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36596507

RESUMO

Prolidase is the only enzyme capable of cleaving imidodipeptides containing C-terminal proline (Pro) or hydroxyproline and plays a crucial role in several physiological processes such as wound healing and cell proliferation. Here, we developed a new method to determine prolidase activity. This method is based on a novel fluorescence (FL) reaction selective for N-terminal glycine (Gly)-containing peptides using 3,4-dihydroxyphenylacetic acid (3,4-DHPAA). The 3,4-DHPAA can selectively react with Gly-Pro, the substrate for prolidase, and the prolidase activity is measured by monitoring the decrease in FL intensities. The prolidase activities in fibroblasts and HeLa cells were successfully measured by the proposed method. Compared with classical Chinard's method, our method does not require any caustic acids, pre-incubation to activate the enzyme, and heating for reaction with the detection reagent. The proposed method enables facile and specific measurement for biogenic prolidase activity.


Assuntos
Dipeptidases , Peptídeos , Humanos , Células HeLa , Prolina
3.
Sensors (Basel) ; 23(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36904710

RESUMO

Orotate phosphoribosyltransferase (OPRT) exists as a bifunctional enzyme, uridine 5'-monophosphate synthase, in mammalian cells and plays an important role in pyrimidine biosynthesis. Measuring OPRT activity has been considered important for understanding biological events and development of molecular-targeting drugs. In this study, we demonstrate a novel fluorescence method for measuring OPRT activity in living cells. The technique utilizes 4-trifluoromethylbenzamidoxime (4-TFMBAO) as a fluorogenic reagent, which produces selective fluorescence for orotic acid. To perform the OPRT reaction, orotic acid was added to HeLa cell lysate, and a portion of the enzyme reaction mixture was heated at 80 °C for 4 min in the presence of 4-TFMBAO under basic conditions. The resulting fluorescence was measured using a spectrofluorometer, which reflects the consumption of orotic acid by the OPRT. After optimization of the reaction conditions, the OPRT activity was successfully determined in 15 min of enzyme reaction time without further procedures such as purification of OPRT or deproteination for the analysis. The activity obtained was compatible with the value measured by the radiometric method with [3H]-5-FU as the substrate. The present method provides a reliable and facile measurement of OPRT activity and could be useful for a variety of research fields targeting pyrimidine metabolism.


Assuntos
Orotato Fosforribosiltransferase , Ácido Orótico , Humanos , Células HeLa , Orotato Fosforribosiltransferase/metabolismo , Pirimidinas
4.
Chem Pharm Bull (Tokyo) ; 70(10): 726-730, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35896347

RESUMO

Several psoralen-conjugated oligonucleotides (Ps-Oligos) have been developed as photo-crosslinkable oligonucleotides targeting DNA or RNA. To avoid potential off-target effects, it is important to investigate the selective photo-crosslinking reactivity of Ps-Oligos to DNA or RNA. However, the selectivity of these Ps-Oligos has not been reported in detail thus far. In this study, we evaluated the photo-crosslinking properties of two Ps-Oligos, 5'-Ps-Oligo and a novel Ps-Oligo containing 2'-O-{[(4,5',8-trimethylpsoralen)-4'-ylmethoxy]ethylaminocarbonyl}adenosine (APs2-Oligo). Notably, 5'-Ps-Oligo preferentially crosslinked with DNA, whereas APs2-Oligo preferentially crosslinked with RNA. These results demonstrate the interesting crosslinking properties of Ps-Oligos, which will provide useful information for the molecular design of novel Ps-Oligos in future studies.


Assuntos
Adenosina , Trioxsaleno , DNA , Marcação de Genes , Oligonucleotídeos Antissenso , RNA , Raios Ultravioleta
5.
Sensors (Basel) ; 22(7)2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35408109

RESUMO

Membrane permeabilization stimulated by high-voltage electric pulses has been used to deliver cell-impermeable exogenous molecules. The electric field effect on the cells depends on various experimental parameters, such as electric field strength, the number of electric pulses, and the electroporation medium. In this study, we show the influence of the electroporation medium on membrane permeabilization stimulated by electrical short-circuiting via an aqueous droplet in dielectric oil, a novel methodology developed by our previous investigations. We investigated the membrane permeabilization by three methods, influx of calcium ions, uptake of nucleic acid-binding fluorophores (YO-PRO-1), and calcein leakage. We demonstrated that the external medium conductivity had a significant impact on the cells in all described experiments. The short-circuiting using a low-conductivity electroporation medium enhanced the formation of both transient and irreversible membrane pores. We also found that clathrin-mediated endocytosis contributed to YO-PRO-1 uptake when a cell culture medium was used as an electroporation medium.


Assuntos
Eletricidade , Eletroporação , Permeabilidade da Membrana Celular , Meios de Cultura , Condutividade Elétrica , Eletroporação/métodos , Água
6.
Chem Pharm Bull (Tokyo) ; 69(8): 768-772, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34334520

RESUMO

A facile and reliable fluorescence method for the quantification of urinary uracil concentration is proposed herein. The assay utilizes a specific fluorescence (FL) derivatization reaction for uracil using 3-methylbenzamidoxime as a fluorogenic reagent. Although the presence of urine inhibited the FL reaction, 10 µL of urine was sufficient for the detection of urinary uracil. The uracil derivative was successfully separated from other fluorescent impurities using simple reversed-phase LC with FL detection. Urinary uracil concentrations from 16 people were compared with the concentrations obtained by the traditional column-switching liquid chromatographic analysis with UV detection. The FL derivative of uracil appeared as a single peak in the chromatograms of all samples. However, several samples showed an additional peak overlapping the uracil peak when using the column-switching method because of UV-active impurities. These results indicated that that the present method is not affected by interfering substances in urine and affords a precise determination of urinary uracil. We expect the proposed method to be applicable for diagnosing dihydropyrimidine dehydrogenase deficiency in 5-fluorouracil chemotherapy.


Assuntos
Benzamidinas/química , Fluorescência , Corantes Fluorescentes/química , Uracila/urina , Cromatografia Líquida de Alta Pressão , Humanos , Estrutura Molecular
7.
Chem Pharm Bull (Tokyo) ; 67(8): 772-774, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31105105

RESUMO

A series of chemiluminescent compounds containing a hydrazide group as a nucleophilic functional group has been synthesized. The syntheses were started from chemiluminescent luminol and isoluminol. The linker moiety was easily introduced onto non-nucleophilic exocyclic amino groups of luminol and isoluminol by gentle heating with cyclic acid anhydrides such as glutaric anhydride. The resulting carboxy group was converted to hydrazide by a simple condensation reaction using carbodiimide. Although majority of the synthesized compounds did not emit strong light, a sufficient chemiluminescence intensity was obtained from luminol-amido-C2-hydrazide (L2H) comprising of luminol scaffold with a dimethylene linker. The ability of L2H to form a covalent bond with a macromolecule was further investigated by incubation with oxidized horseradish peroxidase. The analysis on matrix assisted laser desorption/ionization-time of flight (MALDI-TOF) MS revealed that the coupling efficiency of L2H was similar to that of commercially available labelling reagent having a hydrazide group. These results suggested that L2H, the luminol hydrazide containing a dimethylene linker, could be useful for the labelling of macromolecules in the sensitive bioassay such as chemiluminescence immunoassay.


Assuntos
Hidrazinas/química , Medições Luminescentes , Luminol/química , Luminol/síntese química , Substâncias Macromoleculares/síntese química , Substâncias Macromoleculares/química , Modelos Moleculares , Estrutura Molecular
8.
Biomed Microdevices ; 17(2): 41, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25749639

RESUMO

Parallel manipulation of single cells is important for reconstructing in vivo cellular microenvironments and studying cell functions. To manipulate single cells and reconstruct their environments, development of a versatile manipulation tool is necessary. In this study, we developed an array of hollow probes using microelectromechanical systems fabrication technology and demonstrated the manipulation of single cells. We conducted a cell aspiration experiment with a glass pipette and modeled a cell using a standard linear solid model, which provided information for designing hollow stepped probes for minimally invasive single-cell manipulation. We etched a silicon wafer on both sides and formed through holes with stepped structures. The inner diameters of the holes were reduced by SiO2 deposition of plasma-enhanced chemical vapor deposition to trap cells on the tips. This fabrication process makes it possible to control the wall thickness, inner diameter, and outer diameter of the probes. With the fabricated probes, single cells were manipulated and placed in microwells at a single-cell level in a parallel manner. We studied the capture, release, and survival rates of cells at different suction and release pressures and found that the cell trapping rate was directly proportional to the suction pressure, whereas the release rate and viability decreased with increasing the suction pressure. The proposed manipulation system makes it possible to place cells in a well array and observe the adherence, spreading, culture, and death of the cells. This system has potential as a tool for massively parallel manipulation and for three-dimensional hetero cellular assays.


Assuntos
Engenharia Biomédica/métodos , Análise de Célula Única/instrumentação , Sobrevivência Celular , Desenho de Equipamento , Células HeLa , Humanos , Dióxido de Silício/química , Análise de Célula Única/métodos
9.
J Fluoresc ; 25(4): 1005-11, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26026930

RESUMO

Orotic acid is an intermediate in the synthesis pathway of uridine-5'-monophosphate, and increases in body fluids of patients suffering from hereditary disorders such as orotic aciduria and hyperammonemia. In this study, we developed a spectrofluorometric method with or without high-performance liquid chromatography for the selective and sensitive quantification of orotic acid in human biological specimens, using 4-trifluoromethylbenzamidoxime (4-TFMBAO) as a fluorogenic reagent. This reagent provided intensive fluorescence for only orotic acid amongst 62 compounds including structurally related bio-substances such as nucleic acid bases, nucleosides, nucleotides, amino acids, vitamins, bilirubin, uric acid, urea, creatine, creatinine and sugars. Under optimized reaction conditions, orotic acid was reacted with 4-TFMBAO, K3[Fe(CN)6] and K2CO3 in an aqueous solution. The fluorescence produced from the orotic acid derivative was measured at an excitation of 340 nm and an emission of 460 nm. A concentration of 1.2 µM orotic acid per 1.0 mM creatinine in normal urine and 0.64 nmol orotic acid per 5.0 × 10(5) HeLa cells were determined by this method. The present method permitted the facile quantification of orotic acid in healthy human urine and cultured HeLa cells by spectrofluorometry and/or high-performance liquid chromatography.


Assuntos
Benzamidinas/química , Cromatografia Líquida de Alta Pressão/métodos , Hidrocarbonetos Fluorados/química , Ácido Orótico/análise , Espectrometria de Fluorescência/métodos , Urinálise/métodos , Adulto , Células HeLa , Humanos , Indicadores e Reagentes , Masculino
10.
RSC Adv ; 14(20): 13827-13836, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38681832

RESUMO

In this study, we established the control and design theory of an autonomously driven dispenser at a steady rotation speed and proposed a dispenser-integrated multiplex enzyme-linked immunosorbent assay (ELISA) device. In establishing the theory of the dispenser, we estimated the flow rate in the dispenser and the applied pressure onto the passive valves, so that the suitable burst pressure of the valves and flow rate could be designed. The dispenser-integrated multiplex ELISA device has the potential to perform flow control for executing an ELISA of 6 samples/standards per chip or 18 samples/standards per compact disk by just steadily rotating a chip. In the immunoassay evaluation of the device using mouse IgG detection, it was confirmed that the device could assay 5 µL of several standards in just 30 min without nonspecific reactions, and although this system has a high limit of detection (LOD, 63.4-164 pg mL-1) it is equal to that of manual assay with a titer plate. The device can be fabricated by transferring the microchannel pattern from a mold without complex assembly or alignment, and it can control the liquid operation by just steadily rotating. Thus, the device system developed will contribute to reducing the cost of fabricating chips and control equipment for ELISA systems. Consequently, a compact, portable, and low-cost ELISA system for point-of-care testing is expected to be realized.

11.
RSC Adv ; 14(31): 22606-22617, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39021458

RESUMO

This study proposes a sequential liquid dispensing method using a centrifugal microfluidic device operating at a constant rotational speed for the multiplexed genetic detection of nucleic acid targets across multiple samples in a single operation. A pair of passive valves integrated into each microchamber enabled the liquid to fill towards the center of rotation against the centrifugal force, facilitating the complete removal of air inside the microchamber. Liquid manipulation can be achievable without any surface coating of the device by exploiting the inherent hydrophobicity of the polymer. Furthermore, design guidelines for the optimization of microfluidic devices are clarified. Consequently, our proposed method allows direct liquid dispensing into the reaction chambers without cross-contamination while simultaneously metering the sample/reagent volume for the colorimetric loop-mediated isothermal amplification (LAMP) reaction. In addition, we demonstrated the simultaneous detection of four foodborne pathogens (Salmonella spp., Vibrio parahaemolyticus, Campylobacter spp., and norovirus genogroup II (GII)) across four samples in a centrifugal microfluidic device within 60 min. Furthermore, the device exhibited high quantitation (R 2 > 0.98) of the DNA concentration in the sample. Our proposed method enables a more compact design by eliminating the need for metering chambers and offers a point-of-care testing platform with high simplicity as it operates at a constant rotational speed.

12.
Anal Biochem ; 433(2): 79-85, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23098702

RESUMO

Caspases are the key regulatory factors of apoptosis and are also found to be involved in inflammatory cytokinesis. Sensitive and selective determination of caspases has significant importance in evaluation of apoptosis, disease diagnosis, and drug development. Here, we developed an assay method for the determination of caspase activity. This method is based on a novel fluorescence (FL) reaction selective for N-terminal Ser-containing peptides. FL derivatization of peptides requires heating in the presence of catechol, HEPES buffer (pH 7.5), and sodium periodate. Under optimized conditions, the reaction showed a unique sequence preference for N-terminal Ser-containing peptides, and a lower detection limit (signal/noise [S/N] = 3) of approximately 0.1 µM was obtained for SKTS and SSNSF. Acetylated substrates were enzymatically cleaved to produce N-terminal Ser-containing peptides, which were selectively converted to FL compounds. The enzyme activities were simultaneously determined as low as 2 U (4.3 nM) caspase-3 and 2.5 U (3.3 nM) caspase-8 by high-performance liquid chromatography (HPLC) with FL detection. The proposed assay method does not require any labeled substrates and can be applied to evaluate cell-based apoptosis and also to study apoptosis inhibitors or inducers.


Assuntos
Caspase 3/química , Caspase 8/química , Fluorescência , Peptídeos/química , Serina/química , Humanos , Peptídeos/síntese química , Sensibilidade e Especificidade
13.
J Fluoresc ; 23(5): 853-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23615929

RESUMO

Diimine ligand (DL) 1 significantly exhibited the fluorescence quenching upon binding to guanine. Changing at the para-substituent of the phenyl ring from the hydroxyl to bromo groups reversely enhanced the fluorescence in the presence of guanine. The reverse in the fluorescence selectivity indicated the profound effect of the substituent at the para-position of the phenyl ring. The simple synthesis of DL 1 and DL 2 with good selectivity for guanine offers these DLs as promising compounds for chemosensors of other guanine derivatives.


Assuntos
Fluorescência , Corantes Fluorescentes/química , Guanina/química , Iminas/química , Ligantes , Estrutura Molecular , Espectrometria de Fluorescência
14.
PLoS One ; 18(5): e0285444, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37146039

RESUMO

We investigated gene electrotransfer using electrical short-circuiting via a cell suspension droplet in dielectric oil. An aqueous droplet of a few microliters placed between a pair of electrodes can be deformed by an intense DC electric field depending on the electric field intensity. When a droplet containing suspended cells and plasmid DNA elongates during deformation and connects the electrodes, the resulting short circuit can cause successful gene electrotransfection into various mammalian cells. We also investigated the influence of the electroporation medium on membrane permeabilization and the mechanisms of gene electrotransfection using short-circuiting via an aqueous droplet. One aim of this study was to investigate the influence of the conductivity of electroporation medium on gene electrotransfer stimulated by short-circuiting. It was found that low-conductivity medium with plasmid DNA resulted in a significant decrease in cell viability compared to the high-conductivity medium with plasmid DNA. Therefore, we demonstrated the influence of exogenous DNA on membrane damage stimulated by droplet electroporation using a low-conductivity medium. Thus, electrical stimulation with the combination of plasmid DNA and the low-conductivity medium resulted in tremendous membrane damage. Linearized plasmid DNA stimulated more significant membrane damage than circular DNA. However, the size of linear DNA did not influence the efflux of small intracellular molecules.


Assuntos
DNA , Eletroporação , Animais , Eletroporação/métodos , Membrana Celular , Condutividade Elétrica , DNA/genética , Plasmídeos/genética , Mamíferos/genética
15.
Micromachines (Basel) ; 14(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37374759

RESUMO

A new generation of nanoscale photosensitizer agents has improved photothermal capabilities, which has increased the impact of photothermal treatments (PTTs) in cancer therapy. Gold nanostars (GNS) are promising for more efficient and less invasive PTTs than gold nanoparticles. However, the combination of GNS and visible pulsed lasers remains unexplored. This article reports the use of a 532 nm nanosecond pulse laser and polyvinylpyrrolidone (PVP)-capped GNS to kill cancer cells with location-specific exposure. Biocompatible GNS were synthesized via a simple method and were characterized under FESEM, UV-visible spectroscopy, XRD analysis, and particle size analysis. GNS were incubated over a layer of cancer cells that were grown in a glass Petri dish. A nanosecond pulsed laser was irradiated on the cell layer, and cell death was verified via propidium iodide (PI) staining. We assessed the effectiveness of single-pulse spot irradiation and multiple-pulse laser scanning irradiation in inducing cell death. Since the site of cell killing can be accurately chosen with a nanosecond pulse laser, this technique will help minimize damage to the cells around the target cells.

16.
Nucleic Acids Res ; 38(19): 6737-45, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20554855

RESUMO

The incorporation of the bicyclic cytosine analogue 7,8-dihydropyrido[2,3-d]pyrimidin-2-one (X) into DNA duplexes results in a significant enhancement of their stability (3-4 K per modification). To establish the effects of X on the local hydrogen-bonding and base stacking interactions and the overall DNA conformation, and to obtain insights into the correlation between the structure and stability of X-containing DNA duplexes, the crystal structures of [d(CGCGAATT-X-GCG)](2) and [d(CGCGAAT-X-CGCG)](2) have been determined at 1.9-2.9 Å resolutions. In all of the structures, the analogue X base pairs with the purine bases on the opposite strands through Watson-Crick and/or wobble type hydrogen bonds. The additional ring of the X base is stacked on the thymine bases at the 5'-side and overall exhibits greatly enhanced stacking interactions suggesting that this is a major contribution to duplex stabilization.


Assuntos
Citosina/análogos & derivados , DNA/química , Modelos Moleculares , Pareamento de Bases , Cristalografia por Raios X , Citosina/química , Corantes Fluorescentes/química , Interações Hidrofóbicas e Hidrofílicas , Conformação de Ácido Nucleico
17.
Micromachines (Basel) ; 13(9)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36144009

RESUMO

Micromixers are one of the critical components in microfluidic devices. They significantly affect the efficiency and sensitivity of microfluidics-based lab-on-a-chip systems. This study introduces an efficient micromixer with a simple geometrical feature that enables easy incorporation in a microchannel network without compromising the original design of microfluidic devices. The study proposes a newly designed planar passive micromixer, termed a planar asymmetric contraction-and-expansion (P-ACE) micromixer, with asymmetric vertical obstacle structures. Numerical simulation and experimental investigation revealed that the optimally designed P-ACE micromixer exhibited a high mixing efficiency of 80% or more within a microchannel length of 10 mm over a wide range of Reynolds numbers (0.13 ≤ Re ≤ 13), eventually attaining approximately 90% mixing efficiency within a 20 mm microchannel length. The highly asymmetric geometric features of the P-ACE micromixers enhance mixing because of their synergistic effects. The flow velocities and directions of the two fluids change differently while alternately crossing the longitudinal centerline of the microchannel, with the obstacle structures asymmetrically arranged on both sidewalls of the rectangular microchannel. This flow behavior increases the interfacial contact area between the two fluids, thus promoting effective mixing in the P-ACE micromixer. Further, the pressure drops in the P-ACE micromixers were experimentally investigated and compared with those in a serpentine micromixer with a perfectly symmetric mixing unit.

18.
Sci Rep ; 12(1): 12852, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35896785

RESUMO

The identification of accidental allergen contamination in processed foods is crucial for risk management strategies in the food processing industry to effectively prevent food allergy incidents. Here, we propose a newly designed passive stop valve with high pressure resistance performance termed an "air plug-in valve" to further improve microfluidic devices for the detection of target nucleic acids. By implementing the air plug-in valve as a permanent stop valve, a maximal allowable flow rate of 70 µL/min could be achieved for sequential liquid dispensing into an array of 10 microchambers, which is 14 times higher than that achieved with the previous valve arrangement using single-faced stop valves. Additionally, we demonstrate the simultaneous detection of multiple food allergens (wheat, buckwheat, and peanut) based on the colorimetric loop-mediated isothermal amplification assay using our diagnostic device with 10 microchambers compactly arranged in a 20-mm-diameter circle. After running the assays at 60 °C for 60 min, any combination of the three types of food allergens and tea plant, which were used as positive and negative control samples, respectively, yielded correct test results, without any cross-contamination among the microchambers. Thus, our diagnostic device will provide a rapid and easy sample-to-answer platform for ensuring food safety and security.


Assuntos
Hipersensibilidade Alimentar , Dispositivos Lab-On-A-Chip , Alérgenos/genética , Arachis/genética , Hipersensibilidade Alimentar/diagnóstico , Microfluídica
19.
Sci Rep ; 12(1): 18343, 2022 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-36316380

RESUMO

Single-cell analysis has been widely used in various biomedical engineering applications, ranging from cancer diagnostics, and immune response monitoring to drug screening. Single-cell isolation is fundamental for observing single-cell activities and an automatic finding method of accurate and reliable cell detection with few possible human errors is also essential. This paper reports trapping single cells into photo patternable hydrogel microwell arrays and isolating them. Additionally, we present an object detection-based DL algorithm that detects single cells in microwell arrays and predicts the presence of cells in resource-limited environments at the highest possible mAP (mean average precision) of 0.989 with an average inference time of 0.06 s. This algorithm leads to the enhancement of the high-throughput single-cell analysis, establishing high detection precision and reduced experimentation time.


Assuntos
Aprendizado Profundo , Hidrogéis , Humanos
20.
Anal Biochem ; 413(1): 50-4, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21300019

RESUMO

Telomere DNA is related to cell aging and cancer genesis because the telomeric region of DNA sequences at chromosome ends are shortened with cell divisions. Therefore, a sensitive and specific detection method is required for the telomere DNA. Here we propose a chemiluminescence (CL)-based method for the sensitive detection of telomere DNA in human cells. In this study, the telomere DNA was amplified by polymerase chain reaction (PCR) using special forward and reverse primers labeled with fluorescein-5-isothiocyanate (FITC) at the 5' end, and then the FITC-containing PCR products were detected by CL reaction with 3,4,5-trimethoxyphenylglyoxal (TMPG) after electrophoresis followed by Southern blot onto a nylon membrane. The TMPG reagent specifically reacted with guanine moiety in DNA at room temperature and provided CL intensities. The CL intensities from the PCR products could be enhanced approximately 10-fold using FITC-labeled primers as compared with those using nonlabeled primers. The detection limit of the PCR products with the proposed method was 0.3 ng on the membrane. The developed CL method could quantitatively determine the telomere DNA in a small number of human cells (∼350) and gave approximately 10 times higher sensitivity than a conventional fluorescence-based method.


Assuntos
Primers do DNA/química , DNA/análise , Fluoresceína-5-Isotiocianato/química , Medições Luminescentes/métodos , Telômero/química , Sequência de Bases , Células Cultivadas , Humanos , Mucosa Bucal/citologia , Reação em Cadeia da Polimerase/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA