Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pancreatology ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38871559

RESUMO

OBJECTIVES: This study aimed to evaluate the clinical impact of preoperative endoscopic ultrasound-guided tissue acquisition (EUS-TA) on the prognosis and incidence of positive peritoneal lavage cytology (PLC) during laparotomy or staging laparoscopy in patients with resectable (R) or borderline resectable (BR) pancreatic ductal adenocarcinoma (PDAC). METHODS: We retrospectively collected data from patients diagnosed with body and tail PDAC with/without EUS-TA at our hospital from January 2006 to December 2021. RESULTS: To examine the effect of EUS-TA on prognosis, 153 patients (122 in the EUS-TA group, 31 in the non-EUS-TA group) were analyzed. There was no significant difference in overall survival between the EUS-TA and non-EUS-TA groups after PDAC resection (P = 0.777). In univariate and multivariate analysis, preoperative EUS-TA was not identified as an independent factor related to overall survival after pancreatectomy [hazard ratio 0.96, 95 % confidence interval (CI) 0.54-1.70, P = 0.897]. Next, to examine the direct influence of EUS-TA on the results of PLC, 114 patients (83 in the EUS-TA group and 31 in the non-EUS-TA group) were analyzed. Preoperative EUS-TA was not statistically associated with positive PLC (odds ratio 0.73, 95 % CI 0.25-2.20, P = 0.583). After propensity score matching, overall survival and positive PLC were the same in both groups. CONCLUSIONS: EUS-TA had no negative impact on postoperative survival and PLC-positive rates in R/BR PDAC.

2.
Gastrointest Endosc ; 99(1): 61-72.e8, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37598864

RESUMO

BACKGROUND AND AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) for malignant distal biliary obstruction (MDBO) may be accompanied by several types of adverse events. The present study analyzed the adverse events occurring after SEMS placement for MDBO. METHODS: The present study retrospectively investigated the incidence and types of adverse events in patients who underwent SEMS placement for MDBO between April 2018 and March 2021 at 26 hospitals. Risk factors for acute pancreatitis, cholecystitis, and recurrent biliary obstruction (RBO) were evaluated by univariate and multivariate analyses. RESULTS: Of the 1425 patients implanted with SEMSs for MDBO, 228 (16.0%) and 393 (27.6%) experienced early adverse events and RBO, respectively. Pancreatic duct without tumor involvement (P = .023), intact papilla (P = .025), and SEMS placement across the papilla (P = .037) were independent risk factors for acute pancreatitis. Tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis (P < .001). Use of fully and partially covered SEMSs was an independent risk factor for food impaction and/or sludge. Use of fully covered SEMSs was an independent risk factor for stent migration. Use of uncovered SEMSs and laser-cut SEMSs was an independent risk factor for tumor ingrowth. CONCLUSIONS: Pancreatic duct without tumor involvement, intact papilla, and SEMS placement across the papilla were independent risk factors for acute pancreatitis, and tumor involvement in the orifice of the cystic duct was an independent risk factor for cholecystitis. The risk factors for food impaction and/or sludge, stent migration, and tumor ingrowth differed among types of SEMSs.


Assuntos
Neoplasias dos Ductos Biliares , Colecistite , Colestase , Pancreatite , Stents Metálicos Autoexpansíveis , Humanos , Estudos Retrospectivos , Doença Aguda , Esgotos , Pancreatite/etiologia , Pancreatite/complicações , Stents Metálicos Autoexpansíveis/efeitos adversos , Stents/efeitos adversos , Neoplasias dos Ductos Biliares/complicações , Colestase/etiologia , Colestase/cirurgia , Colecistite/etiologia , Colecistite/cirurgia
3.
Gastrointest Endosc ; 99(2): 193-203.e5, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37709151

RESUMO

BACKGROUND AND AIMS: We compared ERCP using a balloon-assisted endoscope (BE-ERCP) with EUS-guided antegrade treatment (EUS-AG) for removal of common bile duct (CBD) stones in patients with Roux-en-Y (R-Y) gastrectomy. METHODS: Consecutive patients who had previous R-Y gastrectomy undergoing BE-ERCP or EUS-AG for CBD stones in 16 centers were retrospectively analyzed. RESULTS: BE-ERCP and EUS-AG were performed in 588 and 59 patients, respectively. Baseline characteristics were similar, except for CBD diameter and angle. The technical success rate was 83.7% versus 83.1% (P = .956), complete stone removal rate was 78.1% versus 67.8% (P = .102), and early adverse event rate was 10.2% versus 18.6% (P = .076) in BE-ERCP and EUS-AG, respectively. The mean number of endoscopic sessions was smaller in BE-ERCP (1.5 ± .8 vs 1.9 ± 1.0 sessions, P = .01), whereas the median total treatment time was longer (90 vs 61.5 minutes, P = .001). Among patients with biliary access, the complete stone removal rate was significantly higher in BE-ERCP (93.3% vs 81.6%, P = .009). Negative predictive factors were CBD diameter ≥15 mm (odds ratio [OR], .41) and an angle of CBD <90 degrees (OR, .39) in BE-ERCP and a stone size ≥10 mm (OR, .07) and an angle of CBD <90 degrees (OR, .07) in EUS-AG. The 1-year recurrence rate was 8.3% in both groups. CONCLUSIONS: Effectiveness and safety of BE-ERCP and EUS-AG were comparable in CBD stone removal for patients after R-Y gastrectomy, but complete stone removal after technical success was superior in BE-ERCP.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Cálculos Biliares , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Retrospectivos , Cálculos Biliares/diagnóstico por imagem , Cálculos Biliares/cirurgia , Gastrectomia , Ducto Colédoco , Endoscópios , Resultado do Tratamento
4.
Dig Endosc ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38845085

RESUMO

The consensus-based TOKYO criteria were proposed as a standardized reporting system for endoscopic transpapillary biliary drainage. The primary objective was to address issues arising from the inconsistent reporting of stent outcomes across studies, which has complicated the comparability and interpretation of study results. However, the original TOKYO criteria were not readily applicable to recent modalities of endoscopic biliary drainage such as biliary drainage based on endoscopic ultrasound or device-assisted endoscopy. There are increasing opportunities for managing hilar biliary obstruction and benign biliary strictures through endoscopic drainage. Biliary ablation has been introduced to manage benign and malignant biliary strictures. In addition, the prolonged survival times of cancer patients have increased the importance of evaluating overall outcomes during the period requiring endoscopic biliary drainage rather than solely focusing on the patency of the initial stent. Recognizing these unmet needs, a committee has been established within the Japan Gastroenterological Endoscopy Society to revise the TOKYO criteria for current clinical practice. The revised criteria propose not only common reporting items for endoscopic biliary drainage overall, but also items specific to various conditions and interventions. The term "stent-demanding time" has been defined to encompass the entire duration of endoscopic biliary drainage, during which the overall stent-related outcomes are evaluated. The revised TOKYO criteria 2024 are expected to facilitate the design and reporting of clinical studies, providing a goal-oriented approach to the evaluation of endoscopic biliary drainage.

5.
Surg Today ; 53(9): 1100-1104, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36790475

RESUMO

Due to the worldwide travel restrictions caused by the 2019 coronavirus disease pandemic, many universities and students lost opportunities to engage in international exchange over the past 2 years. Teleconferencing systems have thus been developed to compensate for severe travel restrictions. Kansai Medical University in Japan and Vilnius University in Lithuania have a collaborative research and academic relationship. The two universities have been conducting an online joint international surgery lecture series for the medical students of both universities. Fifteen lectures were given from October 2021 to May 2022. The lectures focused on gastrointestinal surgery, gastroenterology, radiology, pathology, genetics, laboratory medicine, and organ transplantation. A survey of the attendees indicated that they were generally interested in the content and satisfied with attending this lecture series. Our efforts were successful in providing Japanese and Lithuanian medical students with the opportunity to engage in international exchange through lectures held in each other's countries.


Assuntos
Estudantes de Medicina , Humanos , Inquéritos e Questionários , Universidades , Japão
6.
Gastrointest Endosc ; 96(1): 57-66.e2, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35151711

RESUMO

BACKGROUND AND AIMS: This large multicenter randomized controlled trial compared the diagnostic yields of 22-gauge standard and 22-gauge Franseen needles for EUS-guided tissue acquisition (EUS-TA) of solid pancreatic lesions. METHODS: Consecutive patients with solid pancreatic lesions were prospectively randomized to EUS-TA using standard or Franseen needles. Samples obtained with the first needle pass and with second and subsequent passes were evaluated separately. The primary endpoint was the rate of accuracy for diagnosis of malignancy. Other endpoints were technical success rate, sample cellularity, adverse events, diagnostic accuracy in patient subgroups, and the diagnostic accuracy and numbers of second and subsequent needle passes. RESULTS: Of 523 patients undergoing EUS-TA, 260 were randomized to using standard 22-gauge needles and 263 to 22-gauge Franseen needles. The technical success rate in each group was 99.6%, with similar adverse event rates in the standard (1.5%) and Franseen (.8%) needle groups. First-pass EUS-TA using the Franseen needle resulted in significantly greater diagnostic accuracy (84.0% vs 71.2%, P < .001) and sensitivity (82.4% vs 66.7%, P < .001) than first-pass EUS-TA using a standard needle and also resulted in superior diagnostic accuracy in patients requiring immunostaining. Second and subsequent EUS-TA using Franseen needles showed significantly greater accuracy (94.7% vs 90.0%, P = .049) and sensitivity (94.0% vs 88.6%, P = .047) and required fewer needle passes (1.81 vs 2.03, P = .008) than using standard needles. CONCLUSIONS: EUS-TA with the Franseen needle is superior to EUS-TA with a standard needle with respect to diagnostic accuracy per pass, particularly in patients who require immunostaining, and number of passes when using macroscopic on-site evaluation. (Clinical trial registration numbers: UMIN000030634 and jRCTs052180062.).


Assuntos
Agulhas , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia , Humanos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia
7.
Dig Endosc ; 34(6): 1166-1175, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35122323

RESUMO

OBJECTIVES: Three subcategories of high-risk flat and depressed lesions (FDLs), laterally spreading tumors non-granular type (LST-NG), depressed lesions, and large sessile serrated lesions (SSLs), are highly attributable to post-colonoscopy colorectal cancer (CRC). Efficient and organized educational programs on detecting high-risk FDLs are lacking. We aimed to explore whether a web-based educational intervention with training on FIND clues (fold deformation, intensive stool/mucus attachment, no vessel visibility, and demarcated reddish area) may improve the ability to detect high-risk FDLs. METHODS: This was an international web-based randomized control trial that enrolled non-expert endoscopists in 13 Asian countries. The participants were randomized into either education or non-education group. All participants took the pre-test and post-test to read 60 endoscopic images (40 high-risk FDLs, five polypoid, 15 no lesions) and answered whether there was a lesion. Only the education group received a self-education program (video and training questions and answers) between the tests. The primary outcome was a detection rate of high-risk FDLs. RESULTS: In total, 284 participants were randomized. After excluding non-responders, the final data analyses were based on 139 participants in the education group and 130 in the non-education group. The detection rate of high-risk FDLs in the education group significantly improved by 14.7% (66.6-81.3%) compared with -0.8% (70.8-70.0%) in the non-education group. Similarly, the detection rate of LST-NG, depressed lesions, and large SSLs significantly increased only in the education group by 12.7%, 12.0%, and 21.6%, respectively. CONCLUSION: Short self-education focusing on detecting high-risk FDLs was effective for Asian non-expert endoscopists. (UMIN000042348).


Assuntos
Colonoscopia , Neoplasias Colorretais , Ásia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Humanos , Internet
8.
Dig Endosc ; 33(6): 912-923, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32981141

RESUMO

Endoscopic retrograde cholangiopancreatography (ERCP) is an endoscopic modality established for diagnosis and treatment of pancreaticobiliary diseases. However ERCP in patients with surgically altered anatomy (SAA) has been difficult, and more invasive therapies have been primarily selected. The development of balloon assisted endoscopes (BAEs) innovatively facilitated ERCP in such patients. Recent advances of BAEs and other devices greatly contributed to increasing success of ERCP using BAEs (BAE-ERCP). Furthermore, interventions using Endoscopic Ultrasound (EUS-intervention) have been reported to be useful for pancreaticobiliary diseases in patients with SAA, which provide more options for endoscopic therapies and are also expected as a rescue therapy for difficult cases of BAE-ERCP. In order to thoroughly complete endoscopic treatment for pancreaticobiliary diseases with SAA, it is important to standardize the BAE-ERCP procedures based on the features of respective endoscopes and to establish a strategy for endoscopic treatment which includes analysis of BAE-ERCP difficult cases and selection of cases for rescue therapy. In addition, it is essential to be acquainted with the characteristics of possible adverse events of the procedure and to be able to deal with them for safe accomplishment of endoscopic treatment.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Endoscópios , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Endossonografia , Gastrectomia , Humanos , Complicações Pós-Operatórias
9.
Dig Endosc ; 33(1): 21-53, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33124106

RESUMO

Sedation in gastroenterological endoscopy has become an important medical option in routine clinical care. Here, the Japan Gastroenterological Endoscopy Society and the Japanese Society of Anesthesiologists together provide the revised "Guidelines for sedation in gastroenterological endoscopy" as a second edition to address on-site clinical questions and issues raised for safe examination and treatment using sedated endoscopy. Twenty clinical questions were determined and the strength of recommendation and evidence quality (strength) were expressed according to the "MINDS Manual for Guideline Development 2017." We were able to release up-to-date statements related to clinical questions and current issues relevant to sedation in gastroenterological endoscopy (henceforth, "endoscopy"). There are few reports from Japan in this field (e.g., meta-analyses), and many aspects have been based only on a specialist consensus. In the current scenario, benzodiazepine drugs primarily used for sedation during gastroenterological endoscopy are not approved by national health insurance in Japan, and investigations regarding expense-related disadvantages have not been conducted. Furthermore, including the perspective of beneficiaries (i.e., patients and citizens) during the creation of clinical guidelines should be considered. These guidelines are standardized based on up-to-date evidence quality (strength) and supports on-site clinical decision-making by patients and medical staff. Therefore, these guidelines need to be flexible with regard to the wishes, age, complications, and social conditions of the patient, as well as the conditions of the facility and discretion of the physician.


Assuntos
Gastroenterologia , Sedação Consciente , Endoscopia Gastrointestinal , Humanos , Japão
10.
Pancreatology ; 20(4): 596-601, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32371200

RESUMO

OBJECTIVES: It is important for diagnosing early chronic pancreatitis (CP), which may be improved by therapeutic intervention. We aimed to examine the pancreatic ductal changes on magnetic resonance cholangiopancreatography (MRCP) in patients with early CP defined by the Japanese Diagnostic Criteria. METHODS: This retrospective study included patients suspected early CP and performed both endoscopic ultrasonography (EUS) and MRCP from January 2010 to August 2018. We assessed the diameter of the main pancreatic duct (MPD) and the number of irregularly dilated duct branches using MRCP imaging in early CP. RESULTS: We enrolled 165 patients and 25 patients (15%) fulfilled the diagnostic criteria for early CP. Irregular dilatation of ≥ 3 duct branches on MRCP was more often observed in early CP compared to non-early CP (P = 0.004), although MPD diameter was comparable (2.06 mm in early CP vs. 1.96 in non-early CP, P = 0.698). The sensitivity and specificity were 45% and 74%, respectively. The prevalence of positive MRCP findings in patients with ≥ 2 positive EUS findings was higher than that in patients with 1 positive EUS finding (P = 0.08) and in patients without an EUS finding (P < 0.001). There was no difference in the average diameter of MPD. CONCLUSION: Patients with early CP often exhibit alteration in duct branches and not in MPD in addition to parenchymal alteration. Both pancreatic parenchyma and duct branches might need to be evaluated by EUS and MRCP.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Pancreatite Crônica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Endossonografia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Pâncreas/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
11.
J Gastroenterol Hepatol ; 35(8): 1387-1396, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32103516

RESUMO

BACKGROUND AND AIM: Endoscopic retrograde cholangiopancreatography (ERCP) using balloon-assisted endoscope such as double-balloon endoscope is even effective for patients with surgically altered anatomy. Yet comprehensive studies on complications of ERCP using balloon-assisted endoscope have not been made. We analyzed the characteristics and the causes of complications of ERCP using double-balloon endoscope (DB-ERCP) procedures and aimed to suggest effective managements. METHODS: A total of 1576 procedures of DB-ERCP in 714 patients with surgically altered gastrointestinal anatomy in our hospital were evaluated retrospectively using a statistic analysis. RESULTS: The overall complication occurrence rate was 5.8%. By type of complications are perforation 3.2%, mucosal laceration 0.5%, hemorrhage 1.0%, pancreatitis 0.6%, respiratory disorder 0.4%, and others 0.2%. By type of surgical reconstruction methods were Roux-en-Y reconstruction with choledocho-jejunal anastomosis 4.2%, Roux-en-Y reconstruction without choledocho-jejunal anastomosis 6.7%, pancreaticoduodenectomy 4.5%, pylorus preserving pancreaticoduodenectomy 4.2%, Billroth II gastrectomy (B-II) 11.6%, and other reconstruction method (others) 7.4%. The contributing factors calculated by a multivariate analysis were B-II (odds ratio: 1.864, 95% confidence interval: 1.001-3.471, P = 0.050) and the presence of naïve papilla (odds ratio: 3.268, 95% confidence interval: 1.426-7.490, P = 0.005). CONCLUSIONS: DB-ERCP is a safe method with a total complication rate of 5.8% that could be considered within an acceptable range. The most common complication was the injury of the digestive tract such as perforation. Affecting risk factors for complications were B-II and the presence of naïve papilla. DB-ERCP procedures should be performed carefully of these factors.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Endoscópios Gastrointestinais/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Feminino , Gastroenterostomia , Humanos , Perfuração Intestinal/epidemiologia , Perfuração Intestinal/etiologia , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Fatores de Risco , Segurança
12.
Sensors (Basel) ; 20(12)2020 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-32586048

RESUMO

Surface plasmon polaritons (SPPs) can be generated in graphene at frequencies in the mid-infrared to terahertz range, which is not possible using conventional plasmonic materials such as noble metals. Moreover, the lifetime and confinement volume of such SPPs are much longer and smaller, respectively, than those in metals. For these reasons, graphene plasmonics has potential applications in novel plasmonic sensors and various concepts have been proposed. This review paper examines the potential of such graphene plasmonics with regard to the development of novel high-performance sensors. The theoretical background is summarized and the intrinsic nature of graphene plasmons, interactions between graphene and SPPs induced by metallic nanostructures and the electrical control of SPPs by adjusting the Fermi level of graphene are discussed. Subsequently, the development of optical sensors, biological sensors and important components such as absorbers/emitters and reconfigurable optical mirrors for use in new sensor systems are reviewed. Finally, future challenges related to the fabrication of graphene-based devices as well as various advanced optical devices incorporating other two-dimensional materials are examined. This review is intended to assist researchers in both industry and academia in the design and development of novel sensors based on graphene plasmonics.

13.
Opt Lett ; 44(10): 2598-2601, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-31090741

RESUMO

Low dark current, high-responsivity middle-wavelength infrared (IR) graphene photodetectors using photo-gating amplification of injected photo-carriers are demonstrated. A graphene/p-indium antimonide (InSb) heterojunction and graphene/insulator region were formed. The injected photo-carriers from InSb to graphene were amplified by photo-gating induced in the graphene/tetraethyl orthosilicate (TEOS) region, resulting in the high responsivity and low dark current performance. A responsivity of 14.9 A/W and an ON/OFF ratio of 2.66×104 were achieved. The photoresponse is shown to be determined by the cross-sectional area between the graphene and the TEOS-SiO2, in which the injected photo-carriers into graphene were modulated and amplified by the photo-gating effect. Our results indicate that high-performance IR photodetectors based on the developed graphene photodetectors can be realized.

16.
Gut ; 67(11): 1950-1957, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-28970290

RESUMO

OBJECTIVE: To investigate the success rate of cold snare polypectomy (CSP) for complete resection of 4-9 mm colorectal adenomatous polyps compared with that of hot snare polypectomy (HSP). DESIGN: A prospective, multicentre, randomised controlled, parallel, non-inferiority trial conducted in 12 Japanese endoscopy units. Endoscopically diagnosed sessile adenomatous polyps, 4-9 mm in size, were randomly assigned to the CSP or HSP group. After complete removal of the polyp using the allocated technique, biopsy specimens from the resection margin after polypectomy were obtained. The primary endpoint was the complete resection rate, defined as no evidence of adenomatous tissue in the biopsied specimens, among all pathologically confirmed adenomatous polyps. RESULTS: A total of 796 eligible polyps were detected in 538 of 912 patients screened for eligibility between September 2015 and August 2016. The complete resection rate for CSP was 98.2% compared with 97.4% for HSP. The non-inferiority of CSP for complete resection compared with HSP was confirmed by the +0.8% (90% CI -1.0 to 2.7) complete resection rate (non-inferiority p<0.0001). Postoperative bleeding requiring endoscopic haemostasis occurred only in the HSP group (0.5%, 2 of 402 polyps). CONCLUSIONS: The complete resection rate for CSP is not inferior to that for HSP. CSP can be one of the standard techniques for 4-9 mm colorectal polyps. (Study registration: UMIN000018328).


Assuntos
Pólipos Adenomatosos/cirurgia , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Eletrocoagulação/métodos , Adulto , Idoso , Colo/patologia , Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Eletrocoagulação/efeitos adversos , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
18.
Opt Express ; 26(5): 5665-5674, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29529768

RESUMO

Metal-insulator-metal-based plasmonic metamaterial absorbers (MIM-PMAs) generate strong localized surface plasmon resonance (LSPR) on their surfaces. Therefore, MIM-PMAs are expected to enhance the absorption of graphene coated on their surfaces. Graphene-coated MIM-PMAs (GMIM-PMAs) were developed and their optical properties were investigated both experimentally and numerically at infrared wavelengths. Significant modification of the absorption of GMIM-PMAs was achieved only in the main LSPR wavelength region, where the insulator is lossless. The enhancement of the absorption of graphene could be maximized by the optimization of the insulator thickness of the MIM-PMAs. The results obtained here are expected to contribute to the development of high-responsivity graphene-based photodetectors and optoelectronic devices.

19.
Gastrointest Endosc ; 88(5): 854-864, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29908178

RESUMO

BACKGROUND AND AIMS: Although colonoscopy is the criterion standard for detection of colorectal adenomas, some adenomas are missed. Full-spectrum endoscopy (FUSE) allows for observation with a 330-degree angle of view, which is expected to decrease the miss rate. However, no consensus has been reached regarding the superiority of FUSE over standard forward-viewing colonoscopy (SFVC) for detection of adenomas; we therefore compared new-generation FUSE and SFVC regarding colorectal adenoma miss rate (AMR) in this, the first reported randomized control trial using new-generation FUSE. METHODS: We enrolled individuals aged 40 to 75 years who had been referred for screening, surveillance, fecal occult blood test positivity, or symptoms in a prospective randomized trial of tandem colonoscopy in 8 institutions. Patients were randomly assigned (1:1) via computer-generated stratified randomization. Neither the endoscopists nor patients were blinded to the allocation. The primary endpoint was AMR per patient (AMR-PP). RESULTS: We enrolled 345 patients and included 319 in the per-protocol analyses. AMR-PP was significantly lower with FUSE (11.7%; 95% confidence interval [CI], 8.0%-15.4%) than with SFVC (22.9%; 95% CI, 17.5%-28.3%; P < .001). AMR-PP for lesions ≤5 mm in size was significantly lower with FUSE (10.4%; 95% CI, 6.5%-14.3%) than with SFVC (20.0%; 95% CI, 14.4%-25.6%; P = .0057). Furthermore, AMR-PP in the ascending colon was significantly lower with FUSE (4.3%; 95% CI, 1.4%-7.2%) than with SFVC (10.6%; 95% CI, 6.1%-15.1%; P = .0212). CONCLUSIONS: FUSE is superior to SFVC regarding both AMR-PP and AMR; additionally, AMR-PP is both significantly lower with FUSE than SFVC for lesions ≤5 mm in size and in the ascending colon. (Clinical trial registration number: UMIN000020448.).


Assuntos
Adenoma/diagnóstico , Colonoscópios , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Adenoma/patologia , Idoso , Neoplasias Colorretais/patologia , Intervalos de Confiança , Desenho de Equipamento , Reações Falso-Negativas , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA