Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Arterioscler Thromb Vasc Biol ; 43(3): 399-409, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36633008

RESUMO

For over 25 years, our group has used regenerative medicine strategies to develop improved biomaterials for use in congenital heart surgery. Among other applications, we developed a tissue-engineered vascular graft (TEVG) by seeding tubular biodegradable polymeric scaffolds with autologous bone marrow-derived mononuclear cells. Results of our first-in-human study demonstrated feasibility as the TEVG transformed into a living vascular graft having an ability to grow, making it the first engineered graft with growth potential. Yet, outcomes of this first Food and Drug Administration-approved clinical trial evaluating safety revealed a prohibitively high incidence of early TEVG stenosis, preventing the widespread use of this promising technology. Mechanistic studies in mouse models provided important insight into the development of stenosis and enabled advanced computational models. Computational simulations suggested both a novel inflammation-driven, mechano-mediated process of in vivo TEVG development and an unexpected natural history, including spontaneous reversal of the stenosis. Based on these in vivo and in silico discoveries, we have been able to rationally design strategies for inhibiting TEVG stenosis that have been validated in preclinical large animal studies and translated to the clinic via a new Food and Drug Administration-approved clinical trial. This progress would not have been possible without the multidisciplinary approach, ranging from small to large animal models and computational simulations. This same process is expected to lead to further advances in scaffold design, and thus next generation TEVGs.


Assuntos
Implante de Prótese Vascular , Engenharia Tecidual , Animais , Camundongos , Humanos , Engenharia Tecidual/métodos , Prótese Vascular , Constrição Patológica , Alicerces Teciduais
2.
Pediatr Cardiol ; 44(5): 973-995, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37149833

RESUMO

Patch augmentation of the right ventricular outflow tract (RVOT) and pulmonary artery (PA) arterioplasty are relatively common procedures in the surgical treatment of patients with congenital heart disease. To date, several patch materials have been applied with no agreed upon clinical standard. Each patch type has unique performance characteristics, cost, and availability. There are limited data describing the various advantages and disadvantages of different patch materials. We performed a review of studies describing the clinical performance of various RVOT and PA patch materials and found a limited but growing body of literature. Short-term clinical performance has been reported for a multitude of patch types, but comparisons are limited by inconsistent study design and scarce histologic data. Standard clinical criteria for assessment of patch efficacy and criteria for intervention need to be applied across patch types. The field is progressing with improvements in outcomes due to newer patch technologies focused on reducing antigenicity and promoting neotissue formation which may have the ability to grow, remodel, and repair.


Assuntos
Cardiopatias Congênitas , Tetralogia de Fallot , Obstrução do Fluxo Ventricular Externo , Humanos , Artéria Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Ventrículos do Coração/cirurgia , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Resultado do Tratamento , Tetralogia de Fallot/cirurgia
3.
Pediatr Cardiol ; 43(5): 986-994, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34981140

RESUMO

To date, there has been limited investigation of bioabsorbable atrial septal defect (ASD) or patent foramen ovale (PFO) closure devices using clinically relevant large animal models. The purpose of this study is to explore the function and safety of a bioabsorbable ASD occluder (BAO) system for PFO and/or secundum ASD transcatheter closure. Using a sheep model, the intra-atrial septum was evaluated by intracardiac echo (ICE). If a PFO was not present, atrial communication was created via transseptal puncture. Device implantation across the intra-atrial communication was performed with fluoroscopic and ICE guidance. Our 1st generation device consisted of a main structure of thin Poly(L-lactide-co-epsilon-caprolactone) (PLCL) fibers, and an internal Poly glycolic acid (PGA) fabric. Four procedures validated procedure feasibility. Subsequently, device design was modified for improved transcatheter delivery. The 2nd generation device has a two-layered structure and was implanted in six sheep. Results showed procedural success in 9/10 (90%) animals. With deployment, the 1st generation device did not reform into its original disk shape and did not conform nicely along the atrial septum. The 2nd generation device was implanted in six animals, 3 out of 6 survived out to 1 year. At 1 year post implantation, ICE confirmed no residual shunting. By necropsy, biomaterials had partially degraded, and histology of explanted samples revealed significant device endothelialization and biomaterial replacement with a collagen layer. Our results demonstrate that our modified 2nd generation BAO can be deployed via minimally invasive percutaneous transcatheter techniques. The BAO partially degrades over 1 year and is replaced by host native tissues. Future studies are needed prior to clinical trials.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Implantes Absorvíveis , Animais , Cateterismo Cardíaco/métodos , Seguimentos , Forame Oval Patente/cirurgia , Átrios do Coração , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Ovinos , Resultado do Tratamento
4.
J Magn Reson Imaging ; 51(6): 1641-1658, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31329332

RESUMO

3D printing (3DP) applications for clinical evaluation, preoperative planning, patient and trainee education, and simulation has increased in the past decade. Most of the applications are found in cardiovascular, head and neck, orthopedic, neurological, urological, and oncological surgical cases. This review has three parts. The first part discusses the technical pathway to realizing a physical model, 3DP considerations in pediatric MRI image acquisition, data and resolution requirements, and related structural segmentation and postprocessing steps needed to generalize both virtual and physical models. Standard practices and processing software used in these processes will be assessed. The second part discusses complementary examples in pediatric applications, including cases from cardiology, neuroradiology, neurology, and neurosurgery, head and neck, orthopedics, pelvic and urological applications, oncological applications, and fetal imaging. The third part explores other 3D printing applications and considerations such as using 3DP to develop tissue-specific phantoms and devices for testing in the MR environment, to educate patients and their families, to train clinicians and students, and facility requirements for building a 3DP program. Level of Evidence: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2020;51:1641-1658.


Assuntos
Cardiologia , Impressão Tridimensional , Criança , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Software
5.
Pediatr Cardiol ; 41(8): 1539-1547, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33161457

RESUMO

Children born with single ventricle physiology who undergo Fontan palliation face a diverse set of long-term complications. However, patient follow-up has in large part been limited to single institutional experiences without uniform application of diagnostic modalities to screen for relevant outcomes. Additionally, the use of different graft materials and variable surgical technique as part of the Fontan procedure has further complicated the evaluation of single ventricle patients. The purpose of this review is to define the changes in the Fontan pathway specific to the graft material used and its relationship to patient outcomes. As a means of introduction, we briefly review the historical evolution of the Fontan procedure with a focus on the intent behind design changes and incorporation of different biomaterials. We further delineate changes to the Fontan pathway which include the development of stenosis, differential growth, thrombosis, and calcification. Ultimately, the recognition of the changes noted within the Fontan pathway need to be assessed relative to their impact on patient hemodynamics, functional capacity, and Fontan-associated comorbidities.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/anormalidades , Criança , Pré-Escolar , Constrição Patológica/etiologia , Feminino , Seguimentos , Técnica de Fontan/efeitos adversos , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Masculino , Polietilenotereftalatos/uso terapêutico , Politetrafluoretileno/uso terapêutico , Trombose/etiologia
6.
FASEB J ; : fj201800458, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29906242

RESUMO

We previously developed a tissue-engineered vascular graft (TEVG) made by seeding autologous cells onto a biodegradable tubular scaffold, in an attempt to create a living vascular graft with growth potential for use in children undergoing congenital heart surgery. Results of our clinical trial showed that the TEVG possesses growth capacity but that its widespread clinical use is not yet advisable due to the high incidence of TEVG stenosis. In animal models, TEVG stenosis is caused by increased monocytic cell recruitment and its classic ("M1") activation. Here, we report on the source and regulation of these monocytes. TEVGs were implanted in wild-type, CCR2 knockout ( Ccr2-/-), splenectomized, and spleen graft recipient mice. We found that bone marrow-derived Ly6C+hi monocytes released from sequestration by the spleen are the source of mononuclear cells infiltrating the TEVG during the acute phase of neovessel formation. Furthermore, short-term administration of losartan (0.6 g/L, 2 wk), an angiotensin II type 1 receptor antagonist, significantly reduced the macrophage populations (Ly6C+/-/F480+) in the scaffolds and improved long-term patency in TEVGs. Notably, the combined effect of bone marrow-derived mononuclear cell seeding with short-term losartan treatment completely prevented the development of TEVG stenosis. Our results provide support for pharmacologic treatment with losartan as a strategy to modulate monocyte infiltration into the grafts and thus prevent TEVG stenosis.-Ruiz-Rosado, J. D. D., Lee, Y.-U., Mahler, N., Yi, T., Robledo-Avila, F., Martinez-Saucedo, D., Lee, A. Y., Shoji, T., Heuer, E., Yates, A. R., Pober, J. S., Shinoka, T., Partida-Sanchez, S., Breuer, C. K. Angiotensin II receptor I blockade prevents stenosis of tissue engineered vascular grafts.

7.
J Vasc Surg ; 66(1): 243-250, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27687327

RESUMO

OBJECTIVE: Bioresorbable vascular grafts are biologically active grafts that are entirely reconstituted by host-derived cells through an inflammation-mediated degradation process. Calcification is a detrimental condition that can severely affect graft performance. Therefore, prevention of calcification is of great importance to the success of bioresorbable arterial vascular grafts. The objective of this study was to test whether fast-degrading (FD) bioresorbable arterial grafts with high cellular infiltration will inhibit calcification of grafts. METHODS: We created two versions of bioresorbable arterial vascular grafts, slow-degrading (SD) grafts and FD grafts. Both grafts had the same inner layer composed of a 50:50 poly(l-lactic-co-ε-caprolactone) copolymer scaffold. However, the outer layer of SD grafts was composed of poly(l-lactic acid) nanofiber, whereas the outer layer of FD grafts was composed of a combination of poly(l-lactic acid) and polyglycolic acid nanofiber. Both grafts were implanted in 8- to 10-week-old female mice (n = 15 in the SD group, n = 10 in the FD group) as infrarenal aortic interposition conduits. Animals were observed for 8 weeks. RESULTS: von Kossa staining showed calcification in 7 of 12 grafts in the SD group but zero in the FD group (P < .01, χ2 test). The cell number in the outer layer of FD grafts was significantly higher than in the SD grafts (SD, 0.87 ± 0.65 × 103/mm2; FD, 2.65 ± 1.91 × 103/mm2; P = .02). CONCLUSIONS: The FD bioresorbable arterial vascular graft with high cellular infiltration into the scaffold inhibited calcification of grafts.


Assuntos
Implantes Absorvíveis , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Calcificação Vascular/prevenção & controle , Animais , Aorta Abdominal/patologia , Implante de Prótese Vascular/efeitos adversos , Células Endoteliais/patologia , Feminino , Regulação da Expressão Gênica , Ácido Láctico/química , Camundongos Endogâmicos C57BL , Músculo Liso Vascular/patologia , Miócitos de Músculo Liso/patologia , Nanofibras , Osteogênese/genética , Poliésteres/química , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Desenho de Prótese , Fatores de Tempo , Calcificação Vascular/genética , Calcificação Vascular/metabolismo , Calcificação Vascular/patologia
8.
FASEB J ; 30(7): 2627-36, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27059717

RESUMO

Stenosis is a critical problem in the long-term efficacy of tissue-engineered vascular grafts (TEVGs). We previously showed that host monocyte infiltration and activation within the graft drives stenosis and that TGF-ß receptor 1 (TGF-ßR1) inhibition can prevent it, but the latter effect was attributed primarily to inhibition of mesenchymal cell expansion. In this study, we assessed the effects of TGF-ßR1 inhibition on the host monocytes. Biodegradable TEVGs were implanted as inferior vena cava interposition conduits in 2 groups of C57BL/6 mice (n = 25/group): unseeded grafts and unseeded grafts with TGF-ßR1 inhibitor systemic treatment for the first 2 wk. The TGF-ßR1 inhibitor treatment effectively improved TEVG patency at 6 mo compared to the untreated control group (91.7 vs. 48%, P < 0.001), which is associated with a reduction in classic activation of mononuclear phagocytes. Consistent with these findings, the addition of rTGF-ß to LPS/IFN-γ-stimulated monocytes enhanced secretion of inflammatory cytokines TNF-α, IL-12, and IL-6; this effect was blocked by TGF-ßR1 inhibition (P < 0.0001). These findings suggest that the TGF-ß signaling pathway contributes to TEVG stenosis by inducing classic activation of host monocytes. Furthermore, blocking monocyte activation by TGF-ßR1 inhibition provides a viable strategy for preventing TEVG stenosis while maintaining neotissue formation.-Lee, Y.-U., de Dios Ruiz-Rosado, J., Mahler, N., Best, C. A., Tara, S., Yi, T., Shoji, T., Sugiura, T., Lee, A. Y., Robledo-Avila, F., Hibino, N., Pober, J. S., Shinoka, T., Partida-Sanchez, S., Breuer, C. K. TGF-ß receptor 1 inhibition prevents stenosis of tissue-engineered vascular grafts by reducing host mononuclear phagocyte activation.


Assuntos
Leucócitos Mononucleares/fisiologia , Receptores de Fatores de Crescimento Transformadores beta/metabolismo , Animais , Prótese Vascular , Constrição Patológica , Citocinas/genética , Citocinas/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Receptores de Fatores de Crescimento Transformadores beta/genética , Engenharia Tecidual , Alicerces Teciduais
9.
FASEB J ; 29(6): 2431-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25713026

RESUMO

The first clinical trial of tissue-engineered vascular grafts (TEVGs) identified stenosis as the primary cause of graft failure. In this study, we aimed to elucidate the role of the host immune response in the development of stenosis using a murine model of TEVG implantation. We found that the C.B-17 wild-type (WT) mouse (control) undergoes a dramatic stenotic response, which is nearly completely abolished in the immunodeficient SCID/beige (bg) variant. SCID mice, which lack an adaptive immune system due to the absence of T and B lymphocytes, experienced rates of stenosis comparable to WT controls (average luminal diameter, WT: 0.071 ± 0.035 mm, SCID: 0.137 ± 0.032 mm, SCID/bg: 0.804 ± 0.039 mm; P < 0.001). The bg mutation is characterized by NK cell and platelet dysfunction, and systemic treatment of WT mice with either NK cell-neutralizing (anti-NK 1.1 antibody) or antiplatelet (aspirin/Plavix [clopidogrel bisulfate]; Asp/Pla) therapy achieved nearly half the patency observed in the SCID/bg mouse (NK Ab: 0.356 ± 0.151 mm, Asp/Pla: 0.452 ± 0.130 mm). Scaffold implantation elicited a blunted immune response in SCID/bg mice, as demonstrated by macrophage number and mRNA expression of proinflammatory cytokines in TEVG explants. Implicating the initial innate immune response as a critical factor in graft stenosis may provide a strategy for prognosis and therapy of second-generation TEVGs.


Assuntos
Imunidade Adaptativa/imunologia , Implante de Prótese Vascular/normas , Prótese Vascular/normas , Imunidade Inata/imunologia , Animais , Antígenos de Diferenciação/genética , Antígenos de Diferenciação/imunologia , Antígenos de Diferenciação/metabolismo , Linfócitos B/imunologia , Linfócitos B/metabolismo , Plaquetas/imunologia , Plaquetas/metabolismo , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Constrição Patológica/etiologia , Constrição Patológica/imunologia , Citocinas/genética , Citocinas/imunologia , Feminino , Expressão Gênica/imunologia , Sistema Imunitário/citologia , Sistema Imunitário/imunologia , Sistema Imunitário/metabolismo , Imuno-Histoquímica , Mediadores da Inflamação/imunologia , Mediadores da Inflamação/metabolismo , Células Matadoras Naturais/imunologia , Células Matadoras Naturais/metabolismo , Macrófagos/imunologia , Macrófagos/metabolismo , Camundongos , Camundongos SCID , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Linfócitos T/imunologia , Linfócitos T/metabolismo
10.
Arterioscler Thromb Vasc Biol ; 35(9): 2003-10, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26183618

RESUMO

OBJECTIVE: Despite successful translation of bioresorbable vascular grafts for the repair of congenital heart disease, stenosis remains the primary cause of graft failure. In this study, we investigated the efficacy of long-term treatment with the antiplatelet drugs, aspirin and cilostazol, in preventing stenosis and evaluated the effect of these drugs on the acute phase of inflammation and tissue remodeling. APPROACH AND RESULTS: C57BL/6 mice were fed a drug-mixed diet of aspirin, cilostazol, or normal chow during the course of follow-up. Bioresorbable vascular grafts, composed of poly(glycolic acid) mesh sealed with poly(l-lactide-co-ε-caprolactone), were implanted as inferior vena cava interposition conduits and followed up for 2 weeks (n=10 per group) or 24 weeks (n=15 per group). Both aspirin and cilostazol suppressed platelet activation and attachment onto the grafts. On explant at 24 weeks, well-organized neotissue had developed, and cilostazol treatment resulted in 100% graft patency followed by the aspirin (67%) and no-treatment (60%) groups (P<0.05). Wall thickness and smooth muscle cell proliferation in the neotissue of the cilostazol group were decreased when compared with that of the no-treatment group at 24 weeks. In addition, cilostazol was shown to have an anti-inflammatory effect on neotissue at 2 weeks by regulating the recruitment and activation of monocytes. CONCLUSIONS: Cilostazol prevents stenosis of bioresorbable vascular graft in a mouse inferior vena cava implantation model up to 24 weeks and is accompanied by reduction of smooth muscle cell proliferation and acute inflammation.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Oclusão de Enxerto Vascular/prevenção & controle , Insuficiência Cardíaca/cirurgia , Tetrazóis/farmacologia , Remodelação Vascular/efeitos dos fármacos , Veia Cava Inferior/cirurgia , Animais , Aspirina/farmacologia , Proliferação de Células , Cilostazol , Modelos Animais de Doenças , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/patologia , Insuficiência Cardíaca/patologia , Imuno-Histoquímica , Camundongos , Camundongos Endogâmicos C57BL , Inibidores da Agregação Plaquetária/farmacologia , Falha de Prótese , Resultado do Tratamento
11.
J Vasc Surg ; 62(3): 734-43, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24745941

RESUMO

OBJECTIVE: Autologous grafts are used to repair atherosclerotic cardiovascular diseases; however, many patients lack suitable donor graft tissue. Recently, tissue engineering techniques have emerged to make biologically active blood vessels. We applied this technique to produce arterial grafts using established biodegradable materials without cell seeding. The grafts were evaluated in vivo for vessel remodeling during 12 months. METHODS: Poly(L-lactide-co-ε-caprolactone) scaffolds reinforced by poly(lactic acid) (PLA) fiber were prepared as arterial grafts. Twenty-eight cell-free grafts were implanted as infrarenal aortic interposition grafts in 8-week-old female SCID/Bg mice. Serial ultrasound and micro computed tomography angiography were used to monitor grafts after implantation. Five grafts were harvested for histologic assessments and reverse transcription-quantitative polymerase chain reaction analysis at time points ranging from 4 months to 1 year after implantation. RESULTS: Micro computed tomography indicated that most implanted mice displayed aneurysmal changes (three of five mice at 4 months, four of five mice at 8 months, and two of five mice at 12 months). Histologic assessments demonstrated extensive tissue remodeling leading to the development of well-circumscribed neovessels with an endothelial inner lining, a neointima containing smooth muscle cells and elastin, and a collagen-rich extracellular matrix. There were a few observed calcified deposits, located around residual PLA fibers at 12 months after implantation. Macrophage infiltration into the scaffold, as evaluated by F4/80 immunohistochemical staining, remained after 12 months and was focused mostly around residual PLA fibers. Reverse transcription-quantitative polymerase chain reaction analysis revealed that gene expression of Itgam, a marker for macrophages, and of matrix metalloproteinase 9 was higher than in native aorta during the course of 12 months, indicating prolonged inflammation (Itgam at 8 months: 11.75 ± 0.99 vs native aorta, P < .01; matrix metalloproteinase 9 at 4 months: 4.35 ± 3.05 vs native aorta, P < .05). CONCLUSIONS: In this study, we demonstrated well-organized neotissue of cell-free biodegradable arterial grafts. Although most grafts experienced aneurysmal change, such findings provide insight into the process of tissue-engineered vascular graft remodeling and should allow informed rational design of the next generation of arterial grafts.


Assuntos
Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Engenharia Tecidual/métodos , Remodelação Vascular , Animais , Aorta/diagnóstico por imagem , Aorta/metabolismo , Aorta/patologia , Aorta/fisiopatologia , Aortografia/métodos , Feminino , Regulação da Expressão Gênica , Ácido Láctico/química , Camundongos SCID , Poliésteres/química , Polímeros/química , Desenho de Prótese , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fatores de Tempo , Ultrassonografia Doppler , Grau de Desobstrução Vascular , Microtomografia por Raio-X
12.
Pediatr Cardiol ; 36(8): 1748-53, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26187515

RESUMO

The influence of posttransplant lymphoproliferative disorder (PTLD) on long-term survival in children after heart transplantation (HTx) is not well studied. The United Network for Organ Sharing database was queried from 1987 to 2013 for data on PTLD in relation to induction immunosuppression and recipient Epstein-Barr virus status in children (<18 years of age) who underwent HTx. Of 6818 first-time pediatric heart transplants, 5169 had follow-up data on posttransplant malignancy, with 360 being diagnosed with PTLD. Univariate Cox analysis identified diminished survival after PTLD onset using a time-varying measure of PTLD (HR 2.208; 95 % CI 1.812, 2.689; p < 0.001), although Kaplan-Meier survival functions found no difference in survival between the group ever diagnosed with PTLD and the non-PTLD reference group (log-rank test: χ 1 (2)  = 0.02; p = 0.928). A multivariate Cox model found a greater mortality hazard associated with the development of PTLD after adjusting for recipient EBV seronegativity and other covariates (HR 3.024; 95 % CI 1.902, 4.808; p < 0.001). Induction immunosuppression at time of HTx did not significantly influence posttransplant mortality. The development of PTLD adversely influenced long-term survival in children after HTx after adjusting for confounding variables.


Assuntos
Infecções por Vírus Epstein-Barr/epidemiologia , Transplante de Coração/mortalidade , Transtornos Linfoproliferativos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Adolescente , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Herpesvirus Humano 4 , Humanos , Lactente , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Fatores de Risco , Taxa de Sobrevida , Estados Unidos
13.
Circ J ; 78(1): 12-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24334558

RESUMO

The development of vascular bioengineering has led to a variety of novel treatment strategies for patients with cardiovascular disease. Notably, combining biodegradable scaffolds with autologous cell seeding to create tissue-engineered vascular grafts (TEVG) allows for in situ formation of organized neovascular tissue and we have demonstrated the clinical viability of this technique in patients with congenital heart defects. The role of the scaffold is to provide a temporary 3-dimensional structure for cells, but applying TEVG strategy to the arterial system requires scaffolds that can also endure arterial pressure. Both biodegradable synthetic polymers and extracellular matrix-based natural materials can be used to generate arterial scaffolds that satisfy these requirements. Furthermore, the role of specific cell types in tissue remodeling is crucial and as a result many different cell sources, from matured somatic cells to stem cells, are now used in a variety of arterial TEVG techniques. However, despite great progress in the field over the past decade, clinical effectiveness of small-diameter arterial TEVG (<6mm) has remained elusive. To achieve successful translation of this complex multidisciplinary technology to the clinic, active participation of biologists, engineers, and clinicians is required.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Cardiopatias Congênitas/terapia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Cardiopatias Congênitas/fisiopatologia , Humanos , Engenharia Tecidual/tendências
14.
Acta Biomater ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838904

RESUMO

Macrophages are the primary cell type orchestrating bioresorbable vascular graft (BVG) remodeling and infiltrate from three sources: the adjacent native vessel, circulating blood, and transmural migration from outer surface of the graft. To elucidate the kinetics of macrophage infiltration into the BVG, we fabricated two different bilayer arterial BVGs consisting of a macroporous sponge layer and a microporous electrospun (ES) layer. The Outer ES graft was designed to reduce transmural cell infiltration from the outer surface and the Inner ES graft was designed to reduce cell infiltration from the circulation. These BVGs were implanted in mice as infrarenal abdominal aorta grafts and extracted at 1, 4, and 8 weeks (n = 5, 10, and 10 per group, respectively) for evaluation. Cell migration into BVGs was higher in the Inner ES graft than in the Outer ES graft. For Inner ES grafts, the majority of macrophage largely expressed a pro-inflammatory M1 phenotype but gradually changed to tissue-remodeling M2 macrophages. In contrast, in Outer ES grafts macrophages primarily maintained an M1 phenotype. The luminal surface endothelialized faster in the Inner ES graft; however, the smooth muscle cell layer was thicker in the Outer ES graft. Collagen fibers were more abundant and matured faster in the Inner ES graft than that in the Outer ES graft. In conclusion, compared to macrophages infiltrating from the circulating blood, transmural macrophages from outside promote the acute inflammatory-mediated response for vascular remodeling and subsequent collagen deposition within BVGs. STATEMENT OF SIGNIFICANCE: To elucidate the kinetics of macrophage infiltration into the bioresorbable vascular graft (BVG), two different bilayer arterial BVGs were implanted in mice as infrarenal abdominal aorta grafts. Cell migration into BVGs was higher in the inner electrospun graft which cells mainly infiltrate from outer surface than in the outer electrospun graft which cells mainly infiltrate from the circulating blood. In the inner electrospun grafts, the majority of macrophages changed from the M1 phenotype to the M2 phenotype, however, outer electrospun grafts maintained the M1 phenotype. Collagen fibers matured faster in the Inner electrospun graft. Compared to macrophages infiltrating from the circulating blood, transmural macrophages from outside promote the acute inflammatory-mediated response for vascular remodeling and subsequent collagen deposition within BVGs.

15.
Nat Commun ; 15(1): 2187, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467617

RESUMO

Advancements in congenital heart surgery have heightened the importance of durable biomaterials for adult survivors. Dystrophic calcification poses a significant risk to the long-term viability of prosthetic biomaterials in these procedures. Herein, we describe the natural history of calcification in the most frequently used vascular conduits, expanded polytetrafluoroethylene grafts. Through a retrospective clinical study and an ovine model, we compare the degree of calcification between tissue-engineered vascular grafts and polytetrafluoroethylene grafts. Results indicate superior durability in tissue-engineered vascular grafts, displaying reduced late-term calcification in both clinical studies (p < 0.001) and animal models (p < 0.0001). Further assessments of graft compliance reveal that tissue-engineered vascular grafts maintain greater compliance (p < 0.0001) and distensibility (p < 0.001) than polytetrafluoroethylene grafts. These properties improve graft hemodynamic performance, as validated through computational fluid dynamics simulations. We demonstrate the promise of tissue engineered vascular grafts, remaining compliant and distensible while resisting long-term calcification, to enhance the long-term success of congenital heart surgeries.


Assuntos
Prótese Vascular , Calcinose , Ovinos , Animais , Estudos Retrospectivos , Calcinose/cirurgia , Materiais Biocompatíveis , Politetrafluoretileno
16.
J Am Heart Assoc ; 13(4): e031823, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38353265

RESUMO

BACKGROUND: Perfusion deficits contribute to symptom severity, morbidity, and death in peripheral artery disease (PAD); however, no standard method for quantifying absolute measures of skeletal muscle perfusion exists. This study sought to preclinically test and clinically translate a positron emission tomography (PET) imaging approach using an atherosclerosis-targeted radionuclide, fluorine-18-sodium fluoride (18F-NaF), to quantify absolute perfusion in PAD. METHODS AND RESULTS: Eight Yorkshire pigs underwent unilateral femoral artery ligation and dynamic 18F-NaF PET/computed tomography imaging on the day of and 2 weeks after occlusion. Following 2-week imaging, calf muscles were harvested to quantify microvascular density. PET methodology was validated with microspheres in 4 additional pig studies and translated to patients with PAD (n=39) to quantify differences in calf perfusion across clinical symptoms/stages and perfusion responses in a case of revascularization. Associations between PET perfusion, ankle-brachial index, toe-brachial index, and toe pressure were assessed in relation to symptoms. 18F-NaF PET/computed tomography quantified significant deficits in calf perfusion in pigs following arterial occlusion and perfusion recovery 2 weeks after occlusion that coincided with increased muscle microvascular density. Additional studies confirmed that PET-derived perfusion measures agreed with microsphere-derived perfusion measures. Translation of imaging methods demonstrated significant decreases in calf perfusion with increasing severity of PAD and quantified perfusion responses to revascularization. Perfusion measures were also significantly associated with symptom severity, whereas traditional hemodynamic measures were not. CONCLUSIONS: 18F-NaF PET imaging quantifies perfusion deficits that correspond to clinical stages of PAD and represents a novel perfusion imaging strategy that could be partnered with atherosclerosis-targeted 18F-NaF PET imaging using a single radioisotope injection. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03622359.


Assuntos
Músculo Esquelético , Doença Arterial Periférica , Animais , Humanos , Músculo Esquelético/diagnóstico por imagem , Perfusão , Doença Arterial Periférica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio , Suínos
17.
Proc Natl Acad Sci U S A ; 107(10): 4669-74, 2010 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-20207947

RESUMO

Biodegradable scaffolds seeded with bone marrow mononuclear cells (BMCs) are the earliest tissue-engineered vascular grafts (TEVGs) to be used clinically. These TEVGs transform into living blood vessels in vivo, with an endothelial cell (EC) lining invested by smooth muscle cells (SMCs); however, the process by which this occurs is unclear. To test if the seeded BMCs differentiate into the mature vascular cells of the neovessel, we implanted an immunodeficient mouse recipient with human BMC (hBMC)-seeded scaffolds. As in humans, TEVGs implanted in a mouse host as venous interposition grafts gradually transformed into living blood vessels over a 6-month time course. Seeded hBMCs, however, were no longer detectable within a few days of implantation. Instead, scaffolds were initially repopulated by mouse monocytes and subsequently repopulated by mouse SMCs and ECs. Seeded BMCs secreted significant amounts of monocyte chemoattractant protein-1 and increased early monocyte recruitment. These findings suggest TEVGs transform into functional neovessels via an inflammatory process of vascular remodeling.


Assuntos
Implante de Prótese Vascular/métodos , Prótese Vascular , Vasos Sanguíneos/fisiopatologia , Engenharia Tecidual/métodos , Animais , Vasos Sanguíneos/metabolismo , Vasos Sanguíneos/patologia , Células da Medula Óssea/citologia , Células da Medula Óssea/metabolismo , Células da Medula Óssea/ultraestrutura , Técnicas de Cultura de Células , Diferenciação Celular , Células Cultivadas , Quimiocina CCL2/metabolismo , Humanos , Imuno-Histoquímica , Inflamação/fisiopatologia , Camundongos , Camundongos SCID , Microscopia Eletrônica de Varredura , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Alicerces Teciduais , Transplante Heterólogo
18.
Bioengineering (Basel) ; 10(2)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36829730

RESUMO

As the number of arteriosclerotic diseases continues to increase, much improvement is still needed with treatments for cardiovascular diseases. This is mainly due to the limitations of currently existing treatment options, including the limited number of donor organs available or the long-term durability of the artificial organs. Therefore, tissue engineering has attracted significant attention as a tissue regeneration therapy in this area. Porous scaffolds are one of the effective methods for tissue engineering. However, it could be better, and its effectiveness varies depending on the tissue application. This paper will address the challenges presented by various materials and their combinations. We will also describe some of the latest methods for tissue engineering.

19.
Biomolecules ; 13(2)2023 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-36830649

RESUMO

Hydrogels are being investigated for their application in inducing the regeneration of various tissues, and suitable conditions for each tissue are becoming more apparent. Conditions such as the mechanical properties, degradation period, degradation mechanism, and cell affinity can be tailored by changing the molecular structure, especially in the case of polymers. Furthermore, many high-functional hydrogels with drug delivery systems (DDSs), in which drugs or bioactive substances are contained in controlled hydrogels, have been reported. This review focuses on the molecular design and function of biopolymer-based hydrogels and introduces recent developments in functional hydrogels for clinical applications.


Assuntos
Materiais Biocompatíveis , Engenharia Tecidual , Materiais Biocompatíveis/química , Hidrogéis/química , Biopolímeros , Sistemas de Liberação de Medicamentos
20.
Biomimetics (Basel) ; 8(1)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36975360

RESUMO

Inducing tissue regeneration in many skin defects, such as large traumatic wounds, burns, other physicochemical wounds, bedsores, and chronic diabetic ulcers, has become an important clinical issue in recent years. Cultured cell sheets and scaffolds containing growth factors are already in use but have yet to restore normal skin tissue structure and function. Many tissue engineering materials that focus on the regeneration process of living tissues have been developed for the more versatile and rapid initiation of treatment. Since the discovery that cells recognize the chemical-physical properties of their surrounding environment, there has been a great deal of work on mimicking the composition of the extracellular matrix (ECM) and its three-dimensional network structure. Approaches have used ECM constituent proteins as well as morphological processing methods, such as fiber sheets, sponges, and meshes. This review summarizes material design strategies in tissue engineering fields, ranging from the morphology of existing dressings and ECM structures to cellular-level microstructure mimicry, and explores directions for future approaches to precision skin tissue regeneration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA