RESUMO
OBJECTIVE: The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS: Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS: In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION: CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS: ⢠In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. ⢠Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. ⢠For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.
Assuntos
Calcinose , Doença da Artéria Coronariana , Calcinose/diagnóstico por imagem , Cálcio , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodosRESUMO
OBJECTIVE: The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. METHODS: Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. RESULTS: CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. CONCLUSION: CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. KEY POINTS: ⢠Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. ⢠In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. ⢠Volumes scores were more accurately determined with spectral photon-counting CT.
Assuntos
Cálcio , Doença da Artéria Coronariana , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVES: To compare the spectral performance of dual-energy CT (DECT) platforms using task-based image quality assessment based on phantom data. MATERIALS AND METHODS: Two CT phantoms were scanned on four DECT platforms: fast kV-switching CT (KVSCT), split filter CT (SFCT), dual-source CT (DSCT), and dual-layer CT (DLCT). Acquisitions on each phantom were performed using classical parameters of abdomen-pelvic examination and a CTDIvol at 10 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated from 40 to 140 keV of virtual monoenergetic images. A detectability index (d') was computed to model the detection task of two contrast-enhanced lesions as function of keV. RESULTS: The noise magnitude decreased from 40 to 70 keV for all DECT platforms, and the highest noise magnitude values were found for KVSCT and SFCT and the lowest for DSCT and DLCT. The average NPS spatial frequency shifted towards lower frequencies as the energy level increased for all DECT platforms, smoothing the image texture. TTF values decreased with the increase of keV deteriorating the spatial resolution. For both simulated lesions, higher detectability (d' value) was obtained at 40 keV for DLCT, DSCT, and SFCT but at 70 keV for KVSCT. The detectability of both simulated lesions was highest for DLCT and DSCT. CONCLUSION: Highest detectability was found for DLCT for the lowest energy levels. The task-based image quality assessment used for the first time for DECT acquisitions showed the benefit of using low keV for the detection of contrast-enhanced lesions. KEY POINTS: ⢠Detectability of both simulated contrast-enhanced lesions was higher for dual-layer CT for the lowest energy levels. ⢠The image noise increased and the image texture changed for the lowest energy levels. ⢠The detectability of both simulated contrast-enhanced lesions was highest at 40 keV for all dual-energy CT platforms except for fast kV-switching platform.
Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Razão Sinal-RuídoRESUMO
Intracranial aneurysm is a pathology related to the deterioration of the arterial wall. This work is an essential part of a large-scale project aimed at providing clinicians with a non-invasive patient-specific decision support tool to facilitate the rupture risk assessment. It will lean on the link between the aneurysm shape clinically observed and a database derived from the in vivo mechanical characterization of aneurysms. To supply this database, a deformation device prototype of the arterial wall was developed. Its use coupled with medical imaging (spectral photon-counting computed tomography providing a spatial resolution down to 250 µm) is used to determine the in vivo mechanical properties of the wall based on the inverse analysis of the quantification of the wall deformation observed experimentally. This study presents the in vivo application of this original procedure to an animal model of aneurysm. The mechanical properties of the aneurysm wall identified were consistent with the literature, and the errors between the numerical and experimental results were less than 10%. Based on these parameters, this study allows the assessment of the aneurysm stress state for a known solicitation and points towards the definition of a rupture criterion.
RESUMO
Multiple cystic lung diseases comprise a wide range of various diseases, some of them of genetic origin. Lymphangioleiomyomatosis (LAM) is a disease occurring almost exclusively in women, sporadically or in association with tuberous sclerosis complex (TSC). Patients with LAM present with lymphatic complications, renal angiomyolipomas and cystic lung disease responsible for spontaneous pneumothoraces and progressive respiratory insufficiency. TSC and LAM have been ascribed to mutations in TSC1 or TSC2 genes. Patients with TSC are variably affected by cutaneous, cognitive and neuropsychiatric manifestations, epilepsy, cerebral and renal tumors, usually of benign nature. Birt-Hogg-Dubé syndrome is caused by mutations in FLCN encoding folliculin. This syndrome includes lung cysts of basal predominance, cutaneous fibrofolliculomas and various renal tumors. The main complications are spontaneous pneumothoraces and renal tumors requiring systematic screening. The mammalian target of rapamycin (mTOR) pathway is involved in the pathophysiology of TSC, sporadic LAM and Birt-Hogg-Dubé syndrome. MTOR inhibitors are used in LAM and in TSC while Birt-Hogg-Dubé syndrome does not progress towards chronic respiratory failure. Future challenges in these often under-recognized diseases include the need to reduce the delay to diagnosis, and to develop potentially curative treatments. In France, physicians can seek help from the network of reference centers for the diagnosis and management of rare pulmonary diseases.
Assuntos
Síndrome de Birt-Hogg-Dubé , Cistos , Neoplasias Renais , Pneumopatias , Linfangioleiomiomatose , Pneumotórax , Adulto , Humanos , Feminino , Síndrome de Birt-Hogg-Dubé/complicações , Síndrome de Birt-Hogg-Dubé/diagnóstico , Síndrome de Birt-Hogg-Dubé/genética , Pneumopatias/etiologia , Pneumopatias/genética , Linfangioleiomiomatose/diagnóstico , Linfangioleiomiomatose/genética , Linfangioleiomiomatose/terapia , Pneumotórax/etiologia , Pneumotórax/genéticaRESUMO
BACKGROUND: Since the previous French guidelines were published in 2017, substantial additional knowledge about idiopathic pulmonary fibrosis has accumulated. METHODS: Under the auspices of the French-speaking Learned Society of Pulmonology and at the initiative of the coordinating reference center, practical guidelines for treatment of rare pulmonary diseases have been established. They were elaborated by groups of writers, reviewers and coordinators with the help of the OrphaLung network, as well as pulmonologists with varying practice modalities, radiologists, pathologists, a general practitioner, a head nurse, and a patients' association. The method was developed according to rules entitled "Good clinical practice" in the overall framework of the "Guidelines for clinical practice" of the official French health authority (HAS), taking into account the results of an online vote using a Likert scale. RESULTS: After analysis of the literature, 54 recommendations were formulated, improved, and validated by the working groups. The recommendations covered a wide-ranging aspects of the disease and its treatment: epidemiology, diagnostic modalities, quality criteria and interpretation of chest CT, indication and modalities of lung biopsy, etiologic workup, approach to familial disease entailing indications and modalities of genetic testing, evaluation of possible functional impairments and prognosis, indications for and use of antifibrotic therapy, lung transplantation, symptom management, comorbidities and complications, treatment of chronic respiratory failure, diagnosis and management of acute exacerbations of fibrosis. CONCLUSION: These evidence-based guidelines are aimed at guiding the diagnosis and the management in clinical practice of idiopathic pulmonary fibrosis.
Assuntos
Fibrose Pulmonar Idiopática , Transplante de Pulmão , Pneumologia , Biópsia , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/epidemiologia , Fibrose Pulmonar Idiopática/terapia , Pulmão/patologiaRESUMO
BACKGROUND: Since the previous French guidelines were published in 2017, substantial additional knowledge about idiopathic pulmonary fibrosis has accumulated. METHODS: Under the auspices of the French-speaking Learned Society of Pulmonology and at the initiative of the coordinating reference center, practical guidelines for treatment of rare pulmonary diseases have been established. They were elaborated by groups of writers, reviewers and coordinators with the help of the OrphaLung network, as well as pulmonologists with varying practice modalities, radiologists, pathologists, a general practitioner, a head nurse, and a patients' association. The method was developed according to rules entitled "Good clinical practice" in the overall framework of the "Guidelines for clinical practice" of the official French health authority (HAS), taking into account the results of an online vote using a Likert scale. RESULTS: After analysis of the literature, 54 recommendations were formulated, improved, and validated by the working groups. The recommendations covered a wide-ranging aspects of the disease and its treatment: epidemiology, diagnostic modalities, quality criteria and interpretation of chest CT, indication and modalities of lung biopsy, etiologic workup, approach to familial disease entailing indications and modalities of genetic testing, evaluation of possible functional impairments and prognosis, indications for and use of antifibrotic therapy, lung transplantation, symptom management, comorbidities and complications, treatment of chronic respiratory failure, diagnosis and management of acute exacerbations of fibrosis. CONCLUSION: These evidence-based guidelines are aimed at guiding the diagnosis and the management in clinical practice of idiopathic pulmonary fibrosis.
Assuntos
Fibrose Pulmonar Idiopática , Transplante de Pulmão , Pneumologia , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/epidemiologia , Fibrose Pulmonar Idiopática/terapia , Pulmão/patologia , PneumologistasRESUMO
PURPOSE: To compare the quantitative and qualitative lung perfusion data acquired with dual energy CT (DECT) to that acquired with a large field-of-view cadmium-zinc-telluride camera single-photon emission CT coupled to a CT system (SPECT-CT). MATERIALS AND METHODS: A total of 53 patients who underwent both dual-layer DECT angiography and perfusion SPECT-CT for pulmonary hypertension or pre-operative lobar resection surgery were retrospectively included. There were 30 men and 23 women with a mean age of 65.4±17.5 (SD)years (range: 18-88years). Relative lobar perfusion was calculated by dividing the amount (of radiotracer or iodinated contrast agent) per lobe by the total amount in both lungs. Linear regression, Bland-Altman analysis, and Pearson's correlation coefficient were also calculated. Kappa test was used to test agreements in morphology and severity of perfusion defects assessed on SPECT-CT and on DECT iodine maps with a one-month interval. Wilcoxon rank sum test was used to compare the sharpness of perfusion defects and radiation dose among modalities. RESULTS: Strong correlations for relative lobar perfusion using linear regression analysis and Pearson's correlation coefficient (r=0.93) were found. Bland-Altman analysis revealed a -0.10 bias, with limits of agreement between [-6.01; 5.81]. With respect to SPECT- CT as standard of reference, the sensitivity, specificity, PPV, NPV, accuracy for lobar perfusion defects were 89.4% (95% CI: 82.6-93.4%), 96.5% (95% CI: 92.1-98.5%), 95.6% (95% CI: 90.9-97.8%), 91.4% (95% CI: 85.6-94.9%) and 93.0% (95% CI: 87.6-96.1%) respectively. High level of agreement was found for morphology and severity of perfusion defects between modalities (Kappa=0.84 and 0.86 respectively) and on DECT images among readers (Kappa=0.94 and 0.89 respectively). A significantly sharper delineation of perfusion defects was found on DECT images (P<0.0001) using a significantly lower equivalent dose of 4.1±2.3 (SD) mSv (range: 1.9-11.85mSv) compared to an equivalent dose of 5.3±1.1 (SD) mSv (range: 2.8-7.3mSv) for SPECT-CT, corresponding to a 21.2% dose reduction (P=0.0004). CONCLUSION: DECT imaging shows strong quantitative correlations and qualitative agreements with SPECT-CT for the evaluation of lung perfusion.
Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Adolescente , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Adulto JovemRESUMO
PURPOSE: To determine the lowest suitable dose level for the detection of pulmonary arteriovenous malformation (PAVM) using a task-based image quality assessment. MATERIAL AND METHODS: A phantom was scanned using the standard chest protocol (STD) and 4 other ultra-low dose protocols (ULD) using various kVp. Raw data were reconstructed using level 5 of the hybrid iterative reconstruction algorithm (iDose4) for the STD protocol, and level 6 of iDose4 and levels 1 to 3 of model-based iterative reconstruction (IMR) for the ULD protocols. Both quantitative criteria and qualitative analysis were used to compare protocols. Noise-power-spectrum and Task-based transfer function were computed using imQuest software. The detectability-index (d') was computed for the detection of PAVM. A subjective analysis was performed by 2 chest radiologists to validate the image-quality obtained on the anthropomorphic phantom for all protocols. RESULTS: Similar d' values were found for ULD-140 using iDose4 6 compared to STD protocol. Greater d' values were found for all ULD protocols using IMR compared to STD. Subjective image quality was rated as acceptable to excellent for ULD-140 and ULD-120 for all reconstruction types, for ULD-100 and ULD-80 using IMR2, and for ULD-100 using IMR1. Image smoothing was poor for IMR3 for ULD-100 and ULD-80. Finally, the ULD-80 protocol reconstructed with IMR2 was chosen for the detection of PAVM. With this protocol, the dose (CTDIvol of 0.3mGy) was reduced by 91% compared with the STD protocol. CONCLUSION: A dose level as low as 0.3mGy reconstructed with IMR2 provides an image quality suitable for the detection of PAVM.
Assuntos
Malformações Arteriovenosas , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Malformações Arteriovenosas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: This work presents our contribution to a data challenge organized by the French Radiology Society during the Journées Francophones de Radiologie in October 2018. This challenge consisted in classifying MR images of the knee with respect to the presence of tears in the knee menisci, on meniscal tear location, and meniscal tear orientation. MATERIALS AND METHODS: We trained a mask region-based convolutional neural network (R-CNN) to explicitly localize normal and torn menisci, made it more robust with ensemble aggregation, and cascaded it into a shallow ConvNet to classify the orientation of the tear. RESULTS: Our approach predicted accurately tears in the database provided for the challenge. This strategy yielded a weighted AUC score of 0.906 for all three tasks, ranking first in this challenge. CONCLUSION: The extension of the database or the use of 3D data could contribute to further improve the performances especially for non-typical cases of extensively damaged menisci or multiple tears.
Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Lesões do Menisco Tibial/diagnóstico por imagem , Conjuntos de Dados como Assunto , HumanosRESUMO
PURPOSE: This work presents our contribution to one of the data challenges organized by the French Radiology Society during the Journées Francophones de Radiologie. This challenge consisted in segmenting the kidney cortex from coronal computed tomography (CT) images, cropped around the cortex. MATERIALS AND METHODS: We chose to train an ensemble of fully-convolutional networks and to aggregate their prediction at test time to perform the segmentation. An image database was made available in 3 batches. A first training batch of 250 images with segmentation masks was provided by the challenge organizers one month before the conference. An additional training batch of 247 pairs was shared when the conference began. Participants were ranked using a Dice score. RESULTS: The segmentation results of our algorithm match the renal cortex with a good precision. Our strategy yielded a Dice score of 0.867, ranking us first in the data challenge. CONCLUSION: The proposed solution provides robust and accurate automatic segmentations of the renal cortex in CT images although the precision of the provided reference segmentations seemed to set a low upper bound on the numerical performance. However, this process should be applied in 3D to quantify the renal cortex volume, which would require a marked labelling effort to train the networks.
Assuntos
Inteligência Artificial , Córtex Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Conjuntos de Dados como Assunto , HumanosRESUMO
PURPOSE: The goal of this data challenge was to create a structured dynamic with the following objectives: (1) teach radiologists the new rules of General Data Protection Regulation (GDPR), while building a large multicentric prospective database of ultrasound, computed tomography (CT) and MRI patient images; (2) build a network including radiologists, researchers, start-ups, large companies, and students from engineering schools, and; (3) provide all French stakeholders working together during 5 data challenges with a secured framework, offering a realistic picture of the benefits and concerns in October 2018. MATERIALS AND METHODS: Relevant clinical questions were chosen by the Société Francaise de Radiologie. The challenge was designed to respect all French ethical and data protection constraints. Multidisciplinary teams with at least one radiologist, one engineering student, and a company and/or research lab were gathered using different networks, and clinical databases were created accordingly. RESULTS: Five challenges were launched: detection of meniscal tears on MRI, segmentation of renal cortex on CT, detection and characterization of liver lesions on ultrasound, detection of breast lesions on MRI, and characterization of thyroid cartilage lesions on CT. A total of 5,170 images within 4 months were provided for the challenge by 46 radiology services. Twenty-six multidisciplinary teams with 181 contestants worked for one month on the challenges. Three challenges, meniscal tears, renal cortex, and liver lesions, resulted in an accuracy>90%. The fourth challenge (breast) reached 82% and the lastone (thyroid) 70%. CONCLUSION: Theses five challenges were able to gather a large community of radiologists, engineers, researchers, and companies in a very short period of time. The accurate results of three of the five modalities suggest that artificial intelligence is a promising tool in these radiology modalities.
Assuntos
Inteligência Artificial , Conjuntos de Dados como Assunto , Neoplasias da Mama/diagnóstico por imagem , Comunicação , Segurança Computacional , Humanos , Relações Interprofissionais , Córtex Renal/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Invasividade Neoplásica/diagnóstico por imagem , Cartilagem Tireóidea/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Lesões do Menisco Tibial/diagnóstico por imagem , Tomografia Computadorizada por Raios X , UltrassonografiaRESUMO
PURPOSE: To evaluate the radiation dose reduction, image quality and diagnostic confidence with thoraco-abdominopelvic computed tomography (TACT) using a new organ based dose modulation system (liver dose right index [Liver DRI]), compared to TACT using a standard automatic exposure control adjusting mA according to attenuation. METHODS: A total of 37 patients who had two TACT examinations on 2 different CT scanners, one using standard automatic exposure control (combination of a DoseRight automatic current selection and Z modulation) and one using Liver DRI were included. There were 19 men and 18 women with a mean age of 67.6±11.7 (SD) years (range: 36-85 years) For each patient, volume CT dose index (CTDIvol), size-specific dose estimates (SSDE) and signal-to-noise ratio (SNR) were evaluated at each anatomic level (lung, breast, liver and pelvis area) for each protocol. Two radiologists assessed independently image quality, artifacts and diagnostic confidence. RESULTS: The radiation dose decreased significantly using Liver DRI compared to standard automatic exposure control on the total scan length, lung, breast and pelvis area, with a significant CTDIvol reduction of 27% (P=0.0001), 23% (P=0.0002), 24% (P=0.0002) and 31% (P=0.0001), respectively; and a significant SSDE reduction of 23% (P=0.0001), 28% (P=0.0001), 23% (P=0.0002) and 29% (P=0.0001), respectively. No significant SNR reductions were observed in all measured tissues at the level of the aortic arch, celiac trunk and iliac bifurcation, except in the muscle (P=0.0013) and fat tissue (P=0.0052) at the level of the ureteral meatus. No significant differences were noted between both protocols in overall image quality, artifacts and diagnostic confidence with an excellent inter observer agreement between radiologists (Kappa values of 0.83, 0.85 and 0.88, respectively). CONCLUSION: Liver DRI organ based dose modulation technique allows significant dose reduction compared to standard automatic exposure control while preserving diagnostic image quality in all thoraco-abdominopelvic areas.
Assuntos
Abdome/diagnóstico por imagem , Fígado/diagnóstico por imagem , Pelve/diagnóstico por imagem , Doses de Radiação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Estudos RetrospectivosRESUMO
OBJECTIVES: To compare the diagnostic performance of "triple rule out" CT angiography (TRO-CTA) at 100kVp using sinogram affirmed iterative reconstruction (SAFIRE) with TRO-CTA at 120kVp using filtered back projection (FBP) in patients with acute chest pain. METHODS: Consecutive non-prepared patients from a single radiological emergency department, referred for acute chest pain evaluation with TRO-CTA, were randomly assigned to two different TRO-CTA protocols. Fifty patients (66% men; mean age, 66.6±19.0 [SD] years [range: 24-97years]) had TRO-CTA at 120kVp with FBP and 97 patients (67% men; mean age, 62.8±17.9 [SD] years [range: 24-93years]) had TRO-CTA at 100kVp with SAFIRE. Two radiologists reviewed the TRO-CTA images for pathologic findings and degree of diagnostic confidence. Image noise, vessel attenuation value, signal-to-noise and contrast-to-noise ratios in five main thoracic arteries were measured for objective and subjective analysis. RESULTS: A total of 147 patients (98 men, 49 women; mean age, 64.7±18.4 [SD] [range, 24-97years) were included with good diagnostic confidence and equivalent pathological findings between the two TRO-CTA protocols. Objective and subjective analysis were identical between protocols and radiologists, except for vessel attenuation in the ascending aorta (P=0.02) and image noise in the pulmonary trunk (P=0.04). The effective radiation dose decreased significantly by 34% in the low dose TRO-CTA using SAFIRE protocol (5.7±2.7 vs 8.6±6.1mSv; P=4.7×10-6). CONCLUSIONS: Low dose TRO-CTA protocol using SAFIRE allows a high confidence diagnostic level with the benefit of a 34% radiation dose decrease compared with a standard TRO-CTA protocol using FBP.
Assuntos
Angiografia por Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Emergências , Serviço Hospitalar de Emergência , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Doses de RadiaçãoAssuntos
Pneumopatias/diagnóstico , Pulmão/diagnóstico por imagem , Sarcoidose Pulmonar/diagnóstico , Doenças Assintomáticas , Diagnóstico Diferencial , Humanos , Pulmão/patologia , Pneumopatias/patologia , Masculino , Fenótipo , Radiografia Torácica , Sarcoidose Pulmonar/diagnóstico por imagem , Sarcoidose Pulmonar/patologia , Adulto JovemRESUMO
In a patient with a mechanical prosthetic aortic valve admitted for transient amnesia, transcranial duplex Doppler and B-mode sonography visualized the transit of microemboli along the main cerebral arteries. Gaseous microemboli resulting from a cavitation phenomenon at valve closure were seen as high-intensity transient signals (HITS). To our knowledge, this is the first report of microemboli flow visualized in B-mode.