Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 42(12): 2172-2174, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34711553

RESUMO

Most unruptured intracranial aneurysms can be adequately characterized using 1.5T and 3T MR imaging. Findings in a subgroup of patients can remain unclear due to difficulties in distinguishing aneurysms from vascular anatomic variants. We retrospectively analyzed clinical data from 30 patients with suspected incidental aneurysms on 3T MR imaging who underwent 7T MR imaging. In all 30 cases, the differentiation of an aneurysm versus a vascular variant could be achieved. In 20 cases (66%), the initial suspected diagnosis was revised. Our findings suggest that 7T MR imaging provides a clarification tool for the group of patients with suspected unruptured intracranial aneurysms and diagnostic ambiguity after standard 3T MR imaging.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
2.
AJNR Am J Neuroradiol ; 27(6): 1357-61, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16775297

RESUMO

BACKGROUND: Recent studies have focused on mechanical thrombectomy as a means to reduce the time required for revascularization and increase the revascularization rate in acute stroke. To date no systematic evaluation has been made of the different mechanical devices in this novel and fast-developing field of endovascular interventions. To facilitate such evaluations, we developed a specific in vivo model for mechanical thrombectomy that allows visualization of dislocation or fragmentation of the thrombus during angiographic manipulation. METHODS: Angiography and embolization with a preformed thrombus was performed in 8 swine. The thrombus was generated by mixing 25 IU bovine thrombin and 10 mL autologous blood. For visualization during angiography, 1 g barium sulfate was added. RESULTS: The preformed thrombus exhibited mechanical stability, reproducibility, and high radiographic absorption, providing excellent visibility during angiography. The setting allowed selective embolization of targeted vessels without thrombus fragmentation. Despite the application of barium sulfate no local or systemic reaction occurred. Histologic evaluation revealed no intimal damage caused by the thrombus or contrast agent washout. CONCLUSION: The model presented here allows selective and reliable thromboembolization of vessels that reproduce the anatomic and hemodynamic situation in acute cerebrovascular stroke. It permits visualization of the thrombus during angiography and intervention, providing unique insight into the behavior of both thrombus and device, which is potentially useful in the development and evaluation of mechanical clot retrieval in acute cerebrovascular stroke.


Assuntos
Modelos Animais de Doenças , Trombose Intracraniana/cirurgia , Acidente Vascular Cerebral/cirurgia , Trombectomia , Doença Aguda , Angiografia , Animais , Angiografia Cerebral , Trombose Intracraniana/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Suínos
3.
J Cereb Blood Flow Metab ; 21(3): 276-84, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11295882

RESUMO

Blood-brain ratios (BBR) of phenylalanine (Phe) were determined by quantitative in vivo 1H magnetic resonance spectroscopy (1H-MRS) in 17 adult patients with early-treated phenylketonuria who were randomly selected from a sample of 75 adults. Measurements were performed in all patients during steady-state conditions. The BBR showed a unimodal distribution with a mean of 4.0 (range 3.3 to 4.5). Blood-brain ratios were comparable for subgroups of patients with genotypes classified as severe, moderate, or mild and for patients on different types of diets. Brain Phe concentrations showed a strong linear correlation with blood Phe values (r = 0.93, P < 0.001). There were no saturation effects for blood Phe values up to 1.8 mmol/L, and a local regression analysis did not confirm increasing BBR for increasing blood Phe values. The intellectual outcome (Wechsler Adult Intelligence Scale) was correlated with long-term dietary control (r = -0.65, P < 0.05), fluctuation of blood Phe values during treatment (r = -0.60, P < 0.05), and concurrent blood and brain Phe concentration. The severity of white matter changes visible on magnetic resonance images (MRI) was increased with high blood and brain Phe concentrations but failed to reach statistical significance. No correlation was found between BBR values, intelligence quotient, and MRI grade. Based on the assumption that BBR show intraindividual stability, the current data do not support the hypothesis that blood-brain barrier transport of Phe is a key explanatory factor for outcome variability in the vast majority of "typical" patients with phenylketonuria.


Assuntos
Barreira Hematoencefálica , Fenilalanina/metabolismo , Fenilcetonúrias/sangue , Adolescente , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Feminino , Genótipo , Humanos , Inteligência , Modelos Lineares , Espectroscopia de Ressonância Magnética , Masculino , Fenilcetonúrias/diagnóstico , Prótons , Índice de Gravidade de Doença
4.
J Magn Reson ; 137(2): 350-7, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10089169

RESUMO

1H MR spectra of human muscles were recorded before, during, and after fatiguing exercise. In contrast to expectations, it was found that the spectral contributions of creatine/phosphocreatine (Cr/PCr) were subject to change as a function of exercise. In particular, the dipolar-coupled methylene protons of Cr/PCr were found to be reduced in intensity in proportion to the co-registered PCr levels. Recovery after exercise and behavior under ischemic conditions provide further evidence to suggest that the contributions of the CH2 protons of Cr/PCr to 1H MR spectra of human muscle in vivo reflect PCr rather than Cr levels. Variation of experimental parameters showed that this effect is not due to a trivial change in relaxation times. At present it can only be speculated about why the Cr resonances have reduced NMR visibility. If temporary binding to macromolecules should be involved, the free Cr concentration-important for equilibrium calculations of the creatine kinase reaction-might be different from what was previously assumed.


Assuntos
Creatina/metabolismo , Espectroscopia de Ressonância Magnética , Músculo Esquelético/metabolismo , Fosfocreatina/metabolismo , Esforço Físico , Adulto , Interpretação Estatística de Dados , Humanos , Ligação de Hidrogênio , Masculino , Pessoa de Meia-Idade , Fibras Musculares Esqueléticas/metabolismo , Prótons
5.
J Magn Reson ; 149(2): 245-50, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11318624

RESUMO

There is a need for absolute quantitation methods in (31)P magnetic resonance spectroscopy, because none of the phosphorous-containing metabolites is necessarily constant in pathology. Here, a method for absolute quantitation of in vivo (31)P MR spectra that provides reproducible metabolite contents in institutional or standard units is described. It relies on the reciprocity principle, i.e., the proportionality between the B(1) field map and the map of reception strength for a coil with identical relative current distributions in receive and transmit mode. Cerebral tissue contents of (31)P metabolites were determined in a predominantly white matter-containing location in healthy subjects. The results are in good agreement with the literature and the interexamination coefficient of variance is better than that in most previous studies. A gender difference found for some of the (31)P metabolites may be explained by different voxel composition.


Assuntos
Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Fósforo/análise , Trifosfato de Adenosina/metabolismo , Adulto , Feminino , Humanos , Masculino , Modelos Biológicos , NAD/metabolismo , Fosfatos/metabolismo , Fosfocreatina/metabolismo , Fosfolipídeos/metabolismo , Reprodutibilidade dos Testes , Fatores Sexuais
6.
Med Sci Sports Exerc ; 31(12): 1770-7, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10613427

RESUMO

PURPOSE: Our purpose was to study effects of creatine (Cr) supplementation on muscle metabolites noninvasively by means of magnetic resonance spectroscopy (MRS) before and after supplementation with Cr or placebo. METHODS: 1H-MRS was used in a comprehensive, double-blind, cross-over study in 10 volunteers to measure Cr in m. tibialis anterior and m. rectus femoris at rest. PCr/ATP was observed in m. quadriceps femoris by 31P-MRS at rest and after exercise. RESULTS: A significant increase in total Cr was observed with Cr intake in m. tibialis anterior (+9.6 +/- 1.7%, P = 0.001) and in m. rectus femoris (+18.0 +/- 1.8%, P < 0.001). PCr/ATP showed a significant increase (+23.9 +/- 2.3%, P < 0.001) in m. quadriceps femoris at rest with Cr supplementation. Post-Cr supplementation recovery rates from exercise were significantly lower (k = 0.029 s(-1), P < 0.01) compared with postplacebo consumption (k = 0.034 s(-1)) and presupplementation (k = 0.037 s(-1)). However, higher levels of PCr/ATP at rest compensate for this reduction of the recovery rate after Cr supplementation. The increase of PCr/ATP determined by 31P-MRS correlates with the increase of Cr observed by 1H-MRS (r = 0.824, P < 0.001). CONCLUSION: Noninvasive observation of Cr and PCr after Cr supplementation shows an increase in a muscle specific manner. Higher preexercise levels of PCr/ATP at rest compensate for significantly slower recovery rates of PCr/ATP after Cr supplementation.


Assuntos
Creatina/administração & dosagem , Músculos/metabolismo , Esportes , Trifosfato de Adenosina/metabolismo , Adulto , Creatina/farmacologia , Estudos Cross-Over , Método Duplo-Cego , Humanos , Imageamento por Ressonância Magnética , Masculino , Músculo Esquelético/metabolismo , Fosfocreatina/metabolismo
7.
Magn Reson Imaging ; 13(1): 159-67, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7898275

RESUMO

This paper reports the results of multicentre studies aimed at designing, constructing, and evaluating prototype test objects for performance assessment in small-bore MRS systems, by utilizing the test protocols already proposed by the EEC COMAC-BME Concerted Action for clinical MRS equipment. Three classes of test objects were considered: (1) a multicompartment test object for 31P MRS measurements performed with slice-selective sequences; (2) a two-compartment test object for volume-selection 1H MRS; and (3) two-compartment test objects for assessing the performance of experimental systems using ISIS as volume localization sequence in 31P MRS. The results suggested the interest of adopting some of these prototypes for improving the comparison of spectroscopy data obtained from different sites, for providing useful means of quality assurance in experimental MRS, and facilitating the validation of new localization sequences.


Assuntos
Espectroscopia de Ressonância Magnética , Controle de Qualidade
8.
Magn Reson Imaging ; 16(9): 1113-25, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9839995

RESUMO

The difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes. Results of a European multi-centre trial show that this approach is suited for assessment of MRSI localization performance.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Animais , Protocolos Clínicos , Interpretação Estatística de Dados , Europa (Continente) , Humanos
9.
Ther Umsch ; 60(9): 569-83, 2003 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-14579626

RESUMO

Interventional neuroradiological techniques are described, which are used for revascularisation of the intra-extracranial vessels in acute stroke. The results are based on our experience gained during the endovascular treatment of more than 300 patients suffering from acute stroke during the last years. Indication, procedures and results of intraarterial thrombolysis, thrombo-aspiration, percutaneous transluminal angioplasty, and implantation of stents in cases of occlusion or pseudoocclusion of brain supplying vessels are discussed. Furthermore first experiences with new techniques from other centers are presented, e.g., thrombolysis by ultrasound (sonothrombolysis), by angiojet aspiration, and laser evaporation of the thromboembolic occlusion of intra- and extracranial blood vessels.


Assuntos
Acidente Vascular Cerebral/terapia , Doença Aguda , Adulto , Idoso , Angiografia , Animais , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/diagnóstico por imagem , Angiografia Cerebral , Revascularização Cerebral , Ensaios Clínicos Controlados como Assunto , Feminino , Fibrinolíticos/administração & dosagem , Fibrinolíticos/uso terapêutico , Seguimentos , Humanos , Hipotermia Induzida , Embolia Intracraniana/terapia , Trombose Intracraniana/terapia , Terapia a Laser , Imageamento por Ressonância Magnética , Masculino , Metanálise como Assunto , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Placebos , Ativadores de Plasminogênio/administração & dosagem , Ativadores de Plasminogênio/uso terapêutico , Prognóstico , Radiologia Intervencionista , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Terapia Trombolítica , Fatores de Tempo , Tomografia Computadorizada por Raios X , Terapia por Ultrassom , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Ativador de Plasminogênio Tipo Uroquinase/uso terapêutico
10.
Clin Neuroradiol ; 24(1): 23-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24482000

RESUMO

PURPOSE: Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS: We compared weighted volume CT dose index (CTDI(vol)) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS: CTDI(Vol) of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS: The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.


Assuntos
Encefalopatias/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
AJNR Am J Neuroradiol ; 31(5): 972-8, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20019112

RESUMO

BACKGROUND AND PURPOSE: Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. MATERIALS AND METHODS: The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. RESULTS: Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. CONCLUSIONS: In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.


Assuntos
Modelos Animais de Doenças , Trombose Intracraniana/diagnóstico , Trombose Intracraniana/cirurgia , Trombectomia/instrumentação , Animais , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Suínos , Resultado do Tratamento
13.
AJNR Am J Neuroradiol ; 30(4): 693-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19213823

RESUMO

BACKGROUND AND PURPOSE: Nonconvulsive status epilepticus (NCSE) is associated with a mortality rate of up to 18%, therefore requiring prompt diagnosis and treatment. Our aim was to evaluate the diagnostic value of perfusion CT (PCT) in the differential diagnosis of NCSE versus postictal states in patients presenting with persistent altered mental states after a preceding epileptic seizure. We hypothesized that regional cortical hyperperfusion can be measured by PCT in patients with NCSE, whereas it is not present in postictal states. MATERIALS AND METHODS: Nineteen patients with persistent altered mental status after a preceding epileptic seizure underwent PCT and electroencephalography (EEG). Patients were stratified as presenting with NCSE (n = 9) or a postictal state (n = 10) on the basis of clinical history and EEG data. Quantitative and visual analysis of the perfusion maps was performed. RESULTS: Patients during NCSE had significantly increased regional cerebral blood flow (P > .0001), increased regional cerebral blood volume (P > .001), and decreased (P > .001) mean transit time compared with the postictal state. Regional cortical hyperperfusion was depicted in 7/9 of patients with NCSE by ad hoc analysis of parametric perfusion maps during emergency conditions but was not a feature of postictal states. The areas of hyperperfusion were concordant with transient clinical symptoms and EEG topography in all cases. CONCLUSIONS: Visual analysis of perfusion maps detected regional hyperperfusion in NCSE with a sensitivity of 78%. The broad availability and short processing time of PCT in an emergency situation is a benefit compared with EEG. Consequently, the use of PCT in epilepsy may accelerate the diagnosis of NCSE. PCT may qualify as a complementary diagnostic tool to EEG in patients with persistent altered mental state after a preceding seizure.


Assuntos
Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/diagnóstico por imagem , Circulação Cerebrovascular , Estado Epiléptico/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Diagnóstico Diferencial , Eletroencefalografia , Serviços Médicos de Emergência , Epilepsia Generalizada/diagnóstico por imagem , Epilepsia Generalizada/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estudos Retrospectivos , Estado Epiléptico/fisiopatologia
14.
AJNR Am J Neuroradiol ; 29(2): 247-52, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17974616

RESUMO

BACKGROUND AND PURPOSE: Although mechanical thrombectomy (MT) has an encouragingly high recanalization rate in treating stroke, it is associated with severe complications of which the underlying factors have yet to be identified. Because MT is a mechanical approach, the mechanical properties of the thrombus might be crucial for its success. The present study assesses the effect of thrombus length on the in vivo effectiveness and complication rate of MT. MATERIALS AND METHODS: Angiography and embolization of 21 cranial vessels with radiopaque whole-blood thrombi 10, 20, and 40 mm in length (7 occlusions each) were performed in 7 swine. MT was carried out using a distal snarelike device (BCR Roadsaver) with proximal balloon occlusion. A total of 61 retrievals were attempted. RESULTS: In the group of 10-mm occlusions, 77.8% of the attempts achieved complete recanalisation. For longer occlusions, the success rates decreased significantly to 20% of attempts for 20-mm occlusions (odds ratio [OR], 14; 95% confidence interval [CI], 2.2-89.2) and 11.1% for 40-mm occlusions (OR, 28; 95% CI, 3.9-202.2; P < .005). The low success rates were largely due to complications associated with thrombus compaction during retrieval. Similarly, the rate of thromboembolic events increased from 0% in 10-mm occlusions to 14.8% in 40-mm occlusions. CONCLUSIONS: MT using a distal device proved to be a fast, effective, and safe procedure for recanalizing short (10-mm) occlusions in the animal model. However, occlusion length emerged as a crucial determinant for MT with a significant decrease in recanalization success per attempt and increased complication rates. These findings suggest limitations of MT in the clinical application.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Medição de Risco/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Animais , Isquemia Encefálica/complicações , Embolização Terapêutica/métodos , Prognóstico , Radiografia , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Suínos , Trombectomia/efeitos adversos , Trombectomia/instrumentação , Trombectomia/métodos , Resultado do Tratamento
15.
Magn Reson Med ; 39(6): 899-911, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9621913

RESUMO

An iterative nonlinear least-squares fitting algorithm in the frequency domain using time domain models for quantification of complex frequency domain MR spectra is presented. The algorithm allows incorporation of prior knowledge and has both the advantage of time-domain fitting with respect to handling the problem of missing data points and truncated data sets and of frequency-domain fitting with respect to multiple frequency-selective fitting. The described algorithm can handle, in addition to Lorentzian and Gaussian lineshapes, Voigt and nonanalytic lineshapes. The program allows the user the design of his own fitting strategy to optimize the probability of reaching the global least-squares minimum. The application of the fitting program is illustrated with examples from in vivo 1H-, 31P-, and 13C-MR spectroscopy.


Assuntos
Inteligência Artificial , Metabolismo Energético/fisiologia , Sistemas Inteligentes , Processamento de Imagem Assistida por Computador/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Imagens de Fantasmas , Algoritmos , Animais , Fenômenos Biofísicos , Biofísica , Simulação por Computador , Sistemas Computacionais , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/instrumentação , Modelos Estatísticos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/fisiologia , Valores de Referência , Suínos , Função Ventricular
16.
Magn Reson Med ; 37(4): 484-93, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9094069

RESUMO

Intra-myocellular lipids (IMCL) are stored in droplets in the cytoplasm of muscle cells and are an energy storage form readily accessed during long-term exercise. 1H-MR spectroscopy methods are presented for noninvasive determination of IMCL in human muscle. This is based on (a) the separation of two resonances in the lipid-CH2-region, with the one assigned to IMCL being independent of muscle orientation relative to the magnetic field and (b) the fact that IMCL resonances scale along with signal amplitudes of metabolites in the muscle cell (e.g., creatine) when voxel size is increased, while lipid signals of bulk fat show a disproportionate growth. Inter-individual and intra-individual reproducibility studies indicate that the error of the method is about 6% and that IMCL levels differ significantly between identical muscles in different subjects, as well as intra-individually when measured at 1 week intervals. IMCL determinations in a single subject before and after strenuous exercise indicate that lipid stores recover with a t1/2 of about 1 day.


Assuntos
Lipídeos/análise , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/química , Adulto , Exercício Físico/fisiologia , Feminino , Humanos , Perna (Membro) , Imageamento por Ressonância Magnética , Masculino , Prótons , Reprodutibilidade dos Testes
17.
Magn Reson Med ; 46(5): 855-63, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11675635

RESUMO

Short-echo-time magnetic resonance spectra of human brain contain broad contributions from macromolecules. As they are a priori of unknown shape and intensity, they pose a problem if one wants to quantitate the overlying spectral features from low-molecular-weight metabolites. On the other hand, the macromolecular contributions may provide relevant clinical information themselves, if properly evaluated. Several methods, based on T(1), T(2), or spectral shape, have previously been suggested to suppress or edit the macromolecule contributions. Here, a method is presented based on a series of saturation recovery scans and that allows for simultaneous recording of the macromolecular baseline and the fully relaxed metabolite spectrum. In comparison to an inversion recovery technique aimed at nulling signals from long-T(1) components, the saturation recovery method is less susceptible to T(1) differences inherent in signals from different metabolites or introduced by pathology. The saturation recovery method was used to quantitate the macromolecular baseline in white and/or gray matter locations of the human brain in 40 subjects. It was found that the content and composition of MR visible macromolecules depends on cerebral location, as well as the age of the investigated subject, while no gender dependence could be found.


Assuntos
Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Adulto , Química Encefálica , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Substâncias Macromoleculares , Masculino , Pessoa de Meia-Idade
18.
Proc Nutr Soc ; 58(4): 841-50, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10817151

RESUMO

Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are being increasingly used for investigations of human muscle physiology. While MRI reveals the morphology of muscles in great detail (e.g. for the determination of muscle volumes), MRS provides information on the chemical composition of the tissue. Depending on the observed nucleus, MRS allows the monitoring of high-energy phosphates (31P MRS), glycogen (13C MRS), or intramyocellular lipids (1H MRS), to give only a few examples. The observation of intramyocellular lipids (IMCL) by means of 1H MRS is non-invasive and, therefore, can be repeated many times and with a high temporal resolution. MRS has the potential to replace the biopsy for the monitoring of IMCL levels; however, the biopsy still has the advantage that other methods such as those used in molecular biology can be applied to the sample. The present study describes variations in the IMCL levels (expressed in mmol/kg wet weight and ml/100 ml) in three different muscles before and after (0, 1, 2, and 5 d) marathon runs for a well-trained individual who followed two different recovery protocols varying mainly in the diet. It was shown that the repletion of IMCL levels is strongly dependent on the diet post exercise. The monitoring of IMCL levels by means of 1H MRS is extremely promising, but several methodological limitations and pitfalls need to be considered, and these are addressed in the present review.


Assuntos
Lipídeos/análise , Espectroscopia de Ressonância Magnética , Músculo Esquelético/química , Dieta , Exercício Físico/fisiologia , Humanos , Líquido Intracelular/química , Líquido Intracelular/metabolismo , Cinética , Metabolismo dos Lipídeos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Músculo Esquelético/ultraestrutura , Corrida
19.
MAGMA ; 11(3): 114-21, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11154952

RESUMO

The rate of glycogen resynthesis in human skeletal muscle after glycogen-depleting exercise is known to depend on carbohydrate intake and is reported to reach a plateau after an adequate amount of carbohydrate (CHO) consumption. Efforts to maximize the rate of glycogen storage by changing the type and form of CHO, as well as by adding proteins or lipids have yielded inconsistent results. The objective of this study was to assess whether isocaloric addition of proteins and arginine to a CHO diet in the first 4 h after an endurance exercise would increase the rate of glycogen synthesis. The CHO solution, given twice at a 2 h interval according to earlier optimized protocols, contained 1.7 g CHO/kg(body weieght) The effects of this solution were compared to those of an isocaloric solution containing 1.2 g CHO/kg(body weight) plus 0.5 g protein/kg(body weight) (including 5 g arginine). Glycogen was measured in quadriceps muscle in vivo with natural abundance 13C-magnetic resonance spectroscopy before exercise and twice after exercise, before and at the end of a 4-h period following the intake of one of the solutions. Eight subjects took part in a randomized cross-over trial separated by at least 1 week. Glycogen synthesis was found to be significantly increased with both regimes compared to a zero-caloric placebo diet, but no significant difference in glycogen resynthesis was found between the CHO-only diet and the one supplemented by proteins and arginine. It is estimated that significance would have been reached for an increase of 34%, while the effectively measured synthesis rates only differed by 5%.


Assuntos
Exercício Físico/fisiologia , Glicogênio/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Fenômenos Fisiológicos da Nutrição , Adulto , Arginina/administração & dosagem , Bebidas , Glicemia/metabolismo , Isótopos de Carbono , Carboidratos da Dieta/administração & dosagem , Proteínas Alimentares/administração & dosagem , Glicogênio/biossíntese , Humanos , Insulina/sangue , Masculino
20.
Magn Reson Med ; 41(4): 715-21, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10332846

RESUMO

A generally applicable method for almost complete suppression of signal artifacts on electrophysiological signals caused by B0-gradient switching (gradient noise) is presented. The method is demonstrated for electrocardiograms (ECGs) but can also be used for other electrophysiological signals. It takes advantage of the fact that under certain conditions, the effect of switching the B0-field gradient upon an electrophysiological signal can be modeled as a linear time-invariant system and fully characterized by pulse response functions. It is shown how the system's pulse response functions of the X, Y, and Z gradients can be determined and how gradient noise can be eliminated efficiently. The elimination of gradient noise by the proposed method causes in the current arrangement a constant delay of 128 msec, which is acceptable for patient monitoring and magnetic resonance sequence triggering.


Assuntos
Eletrocardiografia , Imageamento por Ressonância Magnética , Artefatos , Eletroencefalografia , Eletrofisiologia , Humanos , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA