Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38818846

RESUMO

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas
2.
Cardiol Young ; 34(4): 782-787, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37828640

RESUMO

INTRODUCTION: Cardiac arrhythmias are a major concern in patients with CHD. The purpose of this study was to evaluate the long-term outcomes in patients with CHD submitted to catheter ablation. MATERIALS AND METHODS: Observational retrospective study of patients with CHD referred for catheter ablation from January 2016 to December 2021 in a tertiary referral centre. Acute procedural endpoints and long-term outcomes were assessed. RESULTS: A total of 44 ablation procedures were performed in 36 CHD patients (55% male, mean age 43 ±3 years). Fifty-four arrhythmias were ablated: 23 cavotricuspid isthmus atrial flutters, 10 atrial re-entrant tachycardias, eight focal atrial tachycardias, eight atrial fibrillations, three atrioventricular re-entrant tachycardias, and two ventricular tachycardias. During a median follow-up time of 37 months (interquartile range 12-51), freedom from arrhythmia recurrence was achieved in 93%, with 1.2 procedures per patient (18% with anti-arrhythmic drugs). There were no adverse events related to catheter ablation. No predictors of recurrence were identified. CONCLUSION: In patients with CHD, catheter ablation presents a high mid-term efficacy while maintaining a safe profile.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Cardiopatias Congênitas/cirurgia , Fibrilação Atrial/etiologia , Taquicardia Supraventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia Ventricular/etiologia , Resultado do Tratamento
3.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37345859

RESUMO

AIMS: Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS: Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION: In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Razão de Chances , Veias Pulmonares/cirurgia , Software
4.
BMC Cardiovasc Disord ; 23(1): 609, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087189

RESUMO

BACKGROUND: There is a lack of evidence regarding contemporary implantable cardioverter-defibrillator (ICD) battery longevity. Our aim was to assess battery longevity in ICDs in a real-world setting. METHODS: Retrospective cross-sectional single center study of a prospectively collected database of consecutive patients who underwent ICD implantation from January 2010 to December 2015. Clinical data and battery longevity of all manufacturers were collected. RESULTS: A total of 351 patients (84.6% males, mean age of 61 ± 12 years) were included in the study (292 VVI; 6 VDD; 53 DDD). All manufacturers (Abbott, Biotronik, Boston, Medtronic and Microport) were equally represented in the study (p = 0.110). Median battery longevity was 10.8 years (11 years for VVI and 8.5 for DDD). After a follow-up time of 5 years, 98% of VVI and DDD were still in service (vs. industry-projected longevity of 98%). During this time, 89 patients (25.4%) underwent device replacement - 69 patients (77.5%) due to battery depletion, 6 patients due to infection, 3 patients due to dysfunction and 13 patients due to upgrade to CRT-D. Patients with Medtronic or Biotronik ICDs had a greater probability of being replaced earlier due to battery depletion (Biotronik HR 6.87, 95% CI 2.54-18.58, p < 0.001; Medtronic HR 6.08, 95% CI 2.45-15.06 p < 0.001). CONCLUSIONS: VVI and DDD ICD battery longevity matched industry-projected longevity after 5 years of follow-up. Medtronic and Biotronik ICDs appeared to have an earlier battery depletion. Further randomized studies are required to ensure optimal care.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Falha de Equipamento , Estudos Retrospectivos , Estudos Prospectivos , Estudos Transversais , Desenho de Equipamento , Estimativa de Kaplan-Meier , Fatores de Tempo , Remoção de Dispositivo
5.
J Cardiovasc Electrophysiol ; 33(8): 1725-1733, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637604

RESUMO

PURPOSE: Since the widespread availability of contact-force sensing catheters, the need for a waiting period after pulmonary vein isolation (PVI) has not been reassessed. We aim to evaluate whether a waiting period is still necessary after PVI guided by the ablation Index (AI). METHODS: Prospective, multicenter, randomized study of consecutive patients referred for paroxysmal atrial fibrillation (AF) ablation from May 2019 to February 2020. Patients were randomized in a 1:1 ratio to PVI with versus without a waiting period of 20 min. Acute pulmonary vein (PV) reconnection after adenosine challenge was the primary endpoint. A per-protocol analysis was designed to determine whether a strategy of dismissing the waiting period after PVI was noninferior to waiting for 20 min for identifying acute PV reconnection. PVI was guided by tailored AI values and an interlesion distance ≤6 mm. RESULTS: During the enrollment period, 167 patients (56% males, mean age of 57 ± 14 years) fulfilled the study inclusion criteria - 84 patients (308 PV) in the waiting period group (Group A) and 83 patients (314 PV) in the group without a waiting period (Group B). Acute PV reconnection was identified in 3.8% (95% confidence interval [CI], 1.7%-5.9%) of PVs in the study group B compared to 2.9% (95% CI, 1.0%-4.8%) of PVs in the Group A (p = .002 for non-inferiority). At 1-year follow-up, there was no significant difference in arrhythmia recurrence between groups (9.5% in Group A vs. 9.6% in Group B, hazard ratio: 1.03 [95% CI, 0.39-2.73], p = .98). CONCLUSION: In paroxysmal AF patients submitted to ablation, a tailored PVI guided by the AI rendered a 20-min waiting period unnecessary.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Software , Resultado do Tratamento
6.
BMC Cancer ; 22(1): 732, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35790916

RESUMO

BACKGROUND: The survival of patients with lung cancer has substantially increased in the last decade by about 15%. This increase is, basically, due to targeted therapies available for advanced stages and the emergence of immunotherapy itself. This work aims to study the situation of biomarker testing in Spain. PATIENTS AND METHODS: The Thoracic Tumours Registry (TTR) is an observational, prospective, registry-based study that included patients diagnosed with lung cancer and other thoracic tumours, from September 2016 to 2020. This TTR study was sponsored by the Spanish Lung Cancer Group (GECP) Foundation, an independent, scientific, multidisciplinary oncology society that coordinates more than 550 experts and 182 hospitals across the Spanish territory. RESULTS: Nine thousand two hundred thirty-nine patients diagnosed with stage IV non-small cell lung cancer (NSCLC) between 2106 and 2020 were analysed. 7,467 (80.8%) were non-squamous and 1,772 (19.2%) were squamous. Tumour marker testing was performed in 85.0% of patients with non-squamous tumours vs 56.3% in those with squamous tumours (p-value < 0.001). The global testing of EGFR, ALK, and ROS1 was 78.9, 64.7, 35.6% respectively, in non-squamous histology. PDL1 was determined globally in the same period (46.9%), although if we focus on the last 3 years it exceeds 85%. There has been a significant increase in the last few years of all determinations and there are even close to 10% of molecular determinations that do not yet have targeted drug approval but will have it in the near future. 4,115 cases had a positive result (44.5%) for either EGFR, ALK, KRAS, BRAF, ROS1, or high PDL1. CONCLUSIONS: Despite the lack of a national project and standard protocol in Spain that regulates the determination of biomarkers, the situation is similar to other European countries. Given the growing number of different determinations and their high positivity, national strategies are urgently needed to implement next-generation sequencing (NGS) in an integrated and cost-effective way in lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Biomarcadores Tumorais/análise , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/epidemiologia , Carcinoma Pulmonar de Células não Pequenas/terapia , Demografia , Receptores ErbB/genética , Receptores ErbB/uso terapêutico , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/terapia , Estudos Prospectivos , Proteínas Tirosina Quinases , Proteínas Proto-Oncogênicas , Receptores Proteína Tirosina Quinases , Espanha/epidemiologia
7.
J Cardiovasc Pharmacol ; 79(1): e87-e93, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34775425

RESUMO

ABSTRACT: Digoxin (DG) use in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm remains controversial. We aimed to assess the prognostic effect of DG in patients in sinus rhythm submitted to cardiac resynchronization therapy (CRT). Retrospective study including 297 consecutive patients in sinus rhythm, with advanced HFrEF submitted to CRT. Patients were divided into 2 groups: with DG and without DG (NDG). During a mean follow-up of 4.9 ± 3.4 years, we evaluated the effect of DG on the composite end point defined as cardiovascular hospitalization, progression to heart transplantation, and all-cause mortality. Previous to CRT, 104 patients (35%) chronically underwent DG and 193 patients (65%) underwent NDG treatment. The 2 groups did not differ significantly regarding HF functional class, HF etiology, QRS, and baseline left ventricular ejection fraction. The proportion of responders to CRT was similar in both groups (54% in DG vs. 56% in NDG; P = 0.78). During the long-term follow-up period, the primary end point occurred in a higher proportion in DG patients (67 vs. 48%; P = 0.002). After adjustment for potential confounders, DG use remained as an independent predictor of the composite end point of CV hospitalization, heart transplantation, and all-cause mortality [hazards ratio = 1.58; confidence interval, 95 (1.01-2.46); P = 0.045]. In conclusion, in patients in sinus rhythm with HFrEF submitted to CRT, DG use was associated with CV hospitalization, progression to heart transplant, and all-cause mortality.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiotônicos/uso terapêutico , Digoxina/uso terapêutico , Insuficiência Cardíaca/cirurgia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiotônicos/efeitos adversos , Causas de Morte , Digoxina/efeitos adversos , Progressão da Doença , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Curr Oncol Rep ; 24(2): 135-149, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35061192

RESUMO

PURPOSE OF REVIEW: Circadian rhythms impose daily rhythms a remarkable variety of metabolic and physiological functions, such as cell proliferation, inflammation, and DNA damage response. Accumulating epidemiological and genetic evidence indicates that circadian rhythms' disruption may be linked to cancer. The integration of circadian biology into cancer research may offer new options for increasing cancer treatment effectiveness and would encompass the prevention, diagnosis, and treatment of this disease. RECENT FINDINGS: In recent years, there has been a significant development and use of multi-modal sensors to monitor physical activity, sleep, and circadian rhythms, allowing, for the very first time, scaling accurate sleep monitoring to epidemiological research linking sleep patterns to disease, and wellness applications providing new potential applications. This review highlights the role of circadian clock in tumorigenesis, cancer hallmarks and introduces the state-of-the-art in sleep-monitoring technologies, discussing the eventual application of insights in clinical settings and cancer research.


Assuntos
Relógios Circadianos , Neoplasias , Carcinogênese , Relógios Circadianos/genética , Ritmo Circadiano/genética , Humanos , Sono
10.
Liver Int ; 35(4): 1162-71, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24814243

RESUMO

BACKGROUND & AIMS: Liver regeneration is a multistage process that unfolds gradually, with different mediators acting at different stages of regeneration. Calcium (Ca(2+) ) signalling is essential for liver regeneration. In hepatocytes, Ca(2+) signalling results from the activation of inositol 1,4,5-trisphosphate receptors (InsP3 R) of which two of the three known isoforms are expressed (InsP3 R-I and InsP3 R-II). Here, we investigated the role of the InsP3 R-I-dependent Ca(2+) signals in hepatic proliferation during liver regeneration. METHODS: Partial hepatectomy (HX) in combination with knockdown of InsP3 R-I (AdsiRNA-I) was used to evaluate the role of InsP3 R-I on liver regeneration and hepatocyte proliferation, as assessed by liver to body mass ratio, PCNA expression, immunoblots and measurements of intracellular Ca(2+) signalling. RESULTS: AdsiRNA-I efficiently infected the liver as demonstrated by the expression of ß-galactosidase throughout the liver lobules. Moreover, this construct selectively and efficiently reduced the expression of InsP3 R-I, as evaluated by immunoblots. Expression of AdsiRNA-I in liver decreased peak Ca(2+) amplitude induced by vasopressin in isolated hepatocytes 2 days after HX. Reduced InsP3 R-I expression prior to HX also delayed liver regeneration, as measured by liver to body weight ratio, and reduced hepatocyte proliferation, as evaluated by PCNA staining, at the same time point. At later stages of regeneration, control hepatocytes showed a decreased expression of InsP3 R, as well as reduced InsP3 R-mediated Ca(2+) signalling, events that did not affect liver growth. CONCLUSION: Together, these results show that InsP3 R-I-dependent Ca(2+) signalling is an early triggering pathway required for liver regeneration.


Assuntos
Sinalização do Cálcio , Receptores de Inositol 1,4,5-Trifosfato/metabolismo , Regeneração Hepática , Fígado/metabolismo , Animais , Biomarcadores/metabolismo , Células CHO , Proliferação de Células , Cricetulus , Células HEK293 , Hepatectomia/métodos , Humanos , Receptores de Inositol 1,4,5-Trifosfato/genética , Fígado/fisiopatologia , Fígado/cirurgia , Masculino , Tamanho do Órgão , Antígeno Nuclear de Célula em Proliferação/metabolismo , Interferência de RNA , Ratos Sprague-Dawley , Fatores de Tempo , Transfecção
12.
Cell Commun Signal ; 12: 78, 2014 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-25539979

RESUMO

BACKGROUND: Succinate is an intermediate of the citric acid cycle as well as an extracellular circulating molecule, whose receptor, G protein-coupled receptor-91 (GPR91), was recently identified and characterized in several tissues, including heart. Because some pathological conditions such as ischemia increase succinate blood levels, we investigated the role of this metabolite during a heart ischemic event, using human and rodent models. RESULTS: We found that succinate causes cardiac hypertrophy in a GPR91 dependent manner. GPR91 activation triggers the phosphorylation of extracellular signal-regulated kinase 1/2 (ERK1/2), the expression of calcium/calmodulin dependent protein kinase IIδ (CaMKIIδ) and the translocation of histone deacetylase 5 (HDAC5) into the cytoplasm, which are hypertrophic-signaling events. Furthermore, we found that serum levels of succinate are increased in patients with cardiac hypertrophy associated with acute and chronic ischemic diseases. CONCLUSIONS: These results show for the first time that succinate plays an important role in cardiomyocyte hypertrophy through GPR91 activation, and extend our understanding of how ischemia can induce hypertrophic cardiomyopathy.


Assuntos
Cardiopatias/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Ácido Succínico/metabolismo , Adulto , Animais , Animais Recém-Nascidos , Pressão Sanguínea/efeitos dos fármacos , Cálcio/metabolismo , Proteína Quinase Tipo 2 Dependente de Cálcio-Calmodulina/metabolismo , Cardiopatias/patologia , Histona Desacetilases/metabolismo , Humanos , Cirrose Hepática/metabolismo , Camundongos Knockout , Pessoa de Meia-Idade , Quinases de Proteína Quinase Ativadas por Mitógeno/metabolismo , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Ratos Wistar , Ácido Succínico/sangue
13.
Rev Port Cardiol ; 2024 May 01.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38701967

RESUMO

INTRODUCTION AND OBJECTIVES: Atrial fibrillation (AF) and heart failure (HF) often coexist. AF catheter ablation improves left ventricular ejection fraction (LVEF), but its impact varies between patients. We aimed to identify predictors of LVEF improvement in HF patients with impaired LVEF undergoing AF ablation. METHODS: We conducted a retrospective single-center study in HF patients with LVEF <50% undergoing AF catheter ablation between May 2016 and May 2022. The primary endpoint was the LVEF recovery rate ('responders'). Secondary endpoints were one-year safety and effectiveness. We also aimed to validate a prediction model for LVEF recovery. RESULTS: The study included 100 patients (79% male, median age 60 years, 70% with probable tachycardia-induced cardiomyopathy [TIC], mean LVEF 37%, 29% with paroxysmal AF). After a median follow-up of 12 months after catheter ablation, LVEF improved significantly (36±10% vs. 53±10%, p<0.001), with an 82% responder rate. A suspected diagnosis of TIC (OR 4.916 [95% CI 1.166-20.732], p=0.030), shorter QRS duration (OR 0.969 [95% CI 0.945-0.994], p=0.015), and smaller left ventricle (OR 0.893 [95% CI 0.799-0.999], p=0.049) were independently associated with LVEF improvement. Freedom from any documented atrial arrhythmia was 86% (64% under antiarrhythmic drugs), and the rate of adverse events was 2%. The prediction model had a good discriminative performance (AUC 0.814 [95% CI 0.681-0.947]). CONCLUSION: In AF patients with HF and impaired LVEF, suspected TIC, shorter QRS duration, and smaller LV diameter were associated with LVEF recovery following AF catheter ablation.

14.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38695471

RESUMO

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Assuntos
Fibrilação Atrial , Biomarcadores , Ablação por Cateter , Recidiva , Tireotropina , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/sangue , Biomarcadores/sangue , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Tireotropina/sangue , Peptídeo Natriurético Encefálico/sangue , Valor Preditivo dos Testes , Proteína C-Reativa/análise , Resultado do Tratamento , Tiroxina/sangue , Fatores de Risco , Troponina I/sangue
15.
Rev Port Cardiol ; 42(8): 683-691, 2023 08.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36958571

RESUMO

INTRODUCTION AND OBJECTIVES: There has been increasing interest in pacing methods that provide physiological stimulation, such as His bundle pacing (HBP) or left bundle branch area pacing (LBBAP). Our goal was to assess the feasibility and safety of these techniques. METHODS: Prospective observational single-center study evaluating 46 patients with indication for a pacemaker that attempted HBP or LBBAP from July 2020 to November 2021. Procedural endpoints and pacing parameters were assessed and compared at implantation and three-month follow-up. RESULTS: Overall acute procedural success was achieved in 96% of the cases. Successful HBP was achieved in 91% of the patients and all patients for LBBAP. During implantation, HBP patients presented a higher capture threshold (0.80 [0.55-1.53] V vs. 0.70 [0.40-0.90] V, p=0.08) and lower R-wave amplitude (4.0 [2.9-6.2] mV vs. 7.8 [5.5-10.5] mV, p=0.001) compared to LBBAP patients. There was no difference between groups, either acutely or at 3-months, regarding paced QRS duration (125±22 ms vs. 133±16 ms, p=0.08; 118±16 ms vs. 124±14 ms, p=0.19). Although procedural time was similar with both techniques (95 [75-139] min vs. 95 [74-116] min, p=0.79), fluoroscopy time was significantly reduced during LBBAP (8.1 [5.3-13.4] min vs. 4.1 [3.1-11.3] min, p=0.05). At 3 months of follow-up, the pacing threshold remained with a stable profile in HBP as in LBBAP (1.25 [0.75-2.00] V, p=0.09 and 0.60 [0.50-0.80] V, p=0.78), respectively. The need for re-intervention occurred in 3 (6.5%) HBP cases during follow-up. CONCLUSION: This first national study demonstrates the feasibility and safety of the HBP and LBBAP in patients with pacemaker indication.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Estudos de Viabilidade , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
16.
Front Oncol ; 13: 1074337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910629

RESUMO

Background: Current prognosis in oncology is reduced to the tumour stage and performance status, leaving out many other factors that may impact the patient´s management. Prognostic stratification of early stage non-small-cell lung cancer (NSCLC) patients with poor prognosis after surgery is of considerable clinical relevance. The objective of this study was to identify clinical factors associated with long-term overall survival in a real-life cohort of patients with stage I-II NSCLC and develop a prognostic model that identifies features associated with poor prognosis and stratifies patients by risk. Methods: This is a cohort study including 505 patients, diagnosed with stage I-II NSCLC, who underwent curative surgical procedures at a tertiary hospital in Madrid, Spain. Results: Median OS (in months) was 63.7 (95% CI, 58.7-68.7) for the whole cohort, 62.4 in patients submitted to surgery and 65 in patients submitted to surgery and adjuvant treatment. The univariate analysis estimated that a female diagnosed with NSCLC has a 0.967 (95% CI 0.936 - 0.999) probability of survival one year after diagnosis and a 0.784 (95% CI 0.712 - 0.863) five years after diagnosis. For males, these probabilities drop to 0.904 (95% CI 0.875 - 0.934) and 0.613 (95% CI 0.566 - 0.665), respectively. Multivariable analysis shows that sex, age at diagnosis, type of treatment, ECOG-PS, and stage are statistically significant variables (p<0.10). According to the Cox regression model, age over 50, ECOG-PS 1 or 2, and stage ll are risk factors for survival (HR>1) while adjuvant chemotherapy is a good prognostic variable (HR<1). The prognostic model identified a high-risk profile defined by males over 71 years old, former smokers, treated with surgery, ECOG-PS 2. Conclusions: The results of the present study found that, overall, adjuvant chemotherapy was associated with the best long-term OS in patients with resected NSCLC. Age, stage and ECOG-PS were also significant factors to take into account when making decisions regarding adjuvant therapy.

17.
Int J Cardiol ; 370: 209-214, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36228764

RESUMO

AIMS: To compare the two different ablation strategies, both guided by the Ablation Index (AI), in the setting of atrial fibrillation (AF) ablation: high-power short-duration (HPSD) ablation using 40 W on the posterior wall and 50 W elsewhere versus low-power long-duration (LPLD) using 25 W posteriorly and 35 W elsewhere. METHODS: Prospective, multicenter nonrandomized, noninferiority study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. Ablation was guided by the AI (≥500 for anterior segments, ≥450 for the roof and inferior segments and 400 posteriorly) and an interlesion distance (ILD) ≤ 6 mm. Patients were separated into two groups: HPSD vs LPLD. Acute reconnection (after adenosine trial) and 2-year outcomes were assessed. RESULTS: 160 patients (61% males, median age of 62 [IQR 51-69] years), fulfilled the study inclusion criteria - 80 patients (316 pulmonary veins [PV]) in the HPSD group and 80 patients (314 PV) in the LPLD. The probability of acute PV reconnection was similar between both groups: 2.2% in HPSD, 95%CI 0.6% to 3.8% vs. 3.4% in LPLD, 95%CI 1.4% to 5.4%; p < 0.001 for noninferiority. Median PV ablation time (20 min vs 30 min, p < 0.01) and procedure duration (80 min vs 100 min, p < 0.001) were shorter in the HPSD group. After a median follow-up of 26 months, arrhythmia recurrence was similar between groups (17.5% in HPSD group vs. 18.8% in LPLD group, p = 0.79). CONCLUSIONS: In paroxysmal AF patients treated with the Ablation Index, a HPSD strategy is noninferior to the more standard LPLD ablation, while allowing for quicker procedures with shorter ablation times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
18.
Int J Cardiol ; 383: 33-39, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37116756

RESUMO

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation. METHODS: Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed. RESULTS: During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003). CONCLUSIONS: The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Estudos Prospectivos , Catéteres , Software , Fatores de Tempo , Ablação por Cateter/métodos , Resultado do Tratamento
19.
Insects ; 14(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37103181

RESUMO

Maize grains represent a significant contribution for assuring food safety all over the globe. Sitophilus zeamais (Motschulsky) (Coleoptera: Curculionidae), also known as the maize weevil, is one of the most destructive pests in stored maize, causing qualitative and quantitative losses. To control S. zeamais populations in maize storage sites, synthetical chemical insecticides are applied. However, these are often used wastefully, have environmental implications, and can induce the development of resistant populations. In this work, the insecticidal and grain protecting efficacy of an innovative macro-capsule delivery device, loaded with essential oils from Clove bud and Pennyroyal, as well as their combined solutions, was tested against naturally S. zeamais-infested maize grains. The blend of both compounds incorporated in a controlled release device reduced losses by more than 45% over a long storage period of twenty weeks, diminishing the survivability of maize weevils by over 90%. The usage of the blend at a concentration of 370 µL⋅Lair-1 with an antioxidant showed the best results, however, by halving the concentration (185 µL⋅Lair-1), a significant control of S. zeamais populations was still achieved.

20.
J Interv Card Electrophysiol ; 63(2): 431-440, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34278545

RESUMO

PURPOSE: The purpose of the study was to investigate the usefulness of the extended early meets late (EEML) feature of the HD Coloring software for confirmation of bidirectional block along an ablation line. METHODS: A single-center prospective observational study of consecutive patients with atypical atrial flutter or persistent atrial fibrillation submitted to catheter ablation including linear lesions from January 2019 to June 2020, with confirmation of bidirectional block across ablation lines assessed with the feature EEML and a multipolar catheter was conducted. Patients were divided into two groups - those with versus those without bidirectional block - and different EEML thresholds were analyzed to assess which one had the better sensitivity and specificity to predict block. RESULTS: During the 24-month enrollment period, a total of 94 patients were included (50% males, mean age of 64 ± 10 years, 60% with structural heart disease) - 55 patients with versus 39 patients without confirmed a bidirectional block. Activation maps were performed during atrial pacing, with a median number of 1340 (interquartile range 1135-2060) points acquired in 11 ± 3 min, and a mean mapped cycle length of 287 ± 51 ms. The EEML feature was highly useful in detecting bidirectional block along ablation lines, with a 25% threshold value showing the highest discriminative performance (area under the curve of 0.93), 95% sensitivity and 92% specificity in predicting block. CONCLUSIONS: The EEML feature of the HD Coloring software is a useful addition to the CARTO mapping system for assessment of block across an ablation line. The threshold value of 25% is the most accurate.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Feminino , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA