Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int Biomech ; 8(1): 42-53, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34351832

RESUMO

The location of the instantaneous helical axis (IHA) and the impact of the facet joints (FJ) on the kinematics in the thoracic spine remain inconclusive. This study aimed to examine the IHA in the functional spinal unit (FSU) T4-5 during axial rotation in intact conditions and after bilateral facetectomy. Four human T4-5 FSUs were examined with an established 6D measuring apparatus in intact conditions and after bilateral facetectomy. The IHA's parameters migration, location, and direction in the horizontal plane were calculated. Defined preloads in different positions were applied. Under the intact conditions, the IHA migrated about 4 mm and from one to the contralateral side according to the applied preload. The location of the IHA was observed in the anterior part of the spinal canal. After bilateral facetectomy, the location of the IHA shifted ventrally about 10 mm compared to the intact conditions. Under intact conditions, the direction of the IHA was minimally dorsally reclined. After bilateral facetectomy, the IHA was significantly more ventrally inclined. The study determined the location of the IHA under intact conditions at the anterior part of the spinal canal. The IHA of the FSU T4-5 is substantially influenced by the guidance of the FJs.


Assuntos
Substituição Total de Disco , Articulação Zigapofisária , Fenômenos Biomecânicos , Humanos , Rotação , Coluna Vertebral , Articulação Zigapofisária/cirurgia
2.
J Biomech ; 100: 109608, 2020 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-31926589

RESUMO

Total disc arthroplasty (TDA) increases the risk of adjacent segment disease (ASD). Kinematic analyses are necessary to compare the intact condition (IC) with alterations after TDA to develop better prostheses. A well-established 6D measuring apparatus (resolution < 2.4 µm; 400 positions/cycle) was used. Kinematics of the flexion and extension of 8 human cervical spine segments (cFSU) C3/C4 and C5/C6 (67.9 ± 13.2 y) were analyzed in the IC and after TDA (Bryan® Cervical Disc [B-TDA], Prestige LP® Cervical Disc [P-TDA]). The migration of the instantaneous helical axis (IHA) and the stiffness of the segments were calculated. Analyses demonstrated a stretched U-curved IHA migration in the sagittal plane. The IHA positions were significantly more cranial in cFSU C5/C6 than in C3/C4 in IC and after either TDA (IC: p < 0.001; B-TDA: p = 0.001; P-TDA: p = 0.045). In cFSU C3/C4 IHA positions shifted anteriocranially after either TDA (p < 0.001). In cFSU C5/C6, the IHA positions were significantly more anterocranial after B-TDA than in IC and after P-TDA (anterior: p < 0.001; cranial: p = 0.005). After B-TDA, the IHA migration path length was significantly longer in cFSU C3/C4 than in C5/C6 (p = 0.007) and longer than in IC in both cFSU (C3/C4: p = 0.047; C5/C6: p < 0.001). Stiffness was increased after both TDA. Various kinematic alterations were observed after both TDA. Increased translation and IHA position shifting after both TDA might indicate abnormal strain and a derogated benefit of TDA. These results imply the most abnormal strain after B-TDA. The lower cFSU might be more susceptible to alterations after TDA than the upper cFSU.


Assuntos
Vértebras Cervicais/fisiologia , Fenômenos Mecânicos , Substituição Total de Disco , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Próteses e Implantes
3.
Clin Biomech (Bristol, Avon) ; 73: 130-139, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31982810

RESUMO

BACKGROUND: Information about kinematics in different functional spinal units before and after total disc arthroplasties is necessary to improve prostheses and determine indications. There is little information about the nonstationary instantaneous helical axis of rotation under lateral bending in the cervical spine before and after total disc arthroplasty. METHODS: Kinematic analyses were performed with an established measuring apparatus on 8 human functional spinal units (C3/C4, C5/C6) under intact conditions and after total disc arthroplasty with two different types of prostheses: Bryan and Prestige. The instantaneous helical axis, migration, and stiffness of the segments were calculated. FINDINGS: The instantaneous helical axis direction was always inclined ventrally. Ventral inclination was significantly higher in segment C3/C4 than in segment C5/C6 under all conditions (p < 0.001). Both types of arthroplasties significantly increased ventral inclination compared to intact conditions. In both segments, the path length of the instantaneous helical axis' migration was significantly longer after total disc arthroplasty with Bryan (p = 0.001) and shorter after Prestige (p < 0.001) prostheses than under intact conditions. After both types of arthroplasties, the migration path length was significantly longer and the stiffness was significantly lower in segment C3/C4 than in segment C5/C6. INTERPRETATION: Both types of arthroplasties changed the kinematics of both segments during lateral bending. Altered instantaneous helical axis migration, greater ventral inclination and less stiffness after both arthroplasties indicate unphysiological motion. Both arthroplasties had greater impact on segment C3/C4 than on segment C5/C6 in terms of hypermobility. Increased translational motion after total disc arthroplasty with a Bryan prosthesis might be caused by the prosthetic design.


Assuntos
Vértebras Cervicais , Fenômenos Mecânicos , Substituição Total de Disco , Fenômenos Biomecânicos , Vértebras Cervicais/fisiologia , Humanos , Disco Intervertebral/fisiologia , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação
4.
J Biomech ; 37(4): 583-92, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14996572

RESUMO

The biomechanical properties of the lumbar spine have long been studied. However, despite its enormous importance, basic functional and morphological properties have been not well understood and require further experimental analysis since data concerning the spatial instantaneous segmental motions are hardly available. This study describes the theoretical background and the technical properties of an innovative method for tracking the instantaneous 3D motion of human spinal segments in vitro at high spatial resolution. This new acquisition system allows to scrutinise closely the location and alignment of the segmental instantaneous helical axis (IHA) and the respective screw pitch as functions of the absolute rotational angle. The required precision of the measuring device was attained (a) by six highly resolving linear inductive displacement sensors in a special spatially configuration (3-2-1), (b) by a method to apply torque and force independently of each other without counteraction, and (c) by suppression of vibrations. The validity and reliability of the experimental set-up and the numerical method of data analysis were tested by subjects of known mechanical properties. In vitro experiments with a human lumbar segment (L3/L4, autopsy material) demonstrated that (a) the IHA migrated during axial rotation from one segmental articulatio zygapophysialis to the other joint, (b) the IHA tilted medial-laterally, and (c) the pitch of the screw altered linearly as a function of the rotational angle. This phenomenon is traced back to the guidance of the articluationes zygapophysiales. The validation of the method allows to map segments of the entire vertebral column. The results can be used as benchmarks for future models of the human spine.


Assuntos
Vértebras Lombares/fisiologia , Rotação , Fenômenos Biomecânicos/instrumentação , Calibragem , Desenho de Equipamento , Humanos , Disco Intervertebral/fisiologia , Modelos Biológicos , Fatores de Tempo , Torque , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA